Filtry
wszystkich: 6018
-
Katalog
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: BONE PIEZOELECTRIC PROPERTIES
-
Corrosion degradation of spacers – examination of changes in bone cement coating.
PublikacjaSpacer is a special implant used at the time of infection after endoprosthetic surgery. It consists of a metal core and bone cement coating with an antibiotic. In the human body spacers are exposed to degradation processes. This paper looks at the effect of corrosion on spacers. Electrochemical corrosion tests were performer on titanium pins with bone cement coating in two solutions: Ringer’s solution and artificial...
-
Assembling and testing of quasi-static hybrid piezoelectric motor based on electroactive lubrication principle
PublikacjaThe presented paper concerns a novel concept of hybrid piezoelectric motor based on electroactive lubrication principle. Its structure is combined of quasi-static and resonance piezoelectric actuators, synchronizing their work to generate the rotary movement. The hybrid motor topology is compared to the existing piezoelectric motors, regarding its field of applications in embedded systems with very high security requirements. The...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublikacjaResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
The Optical Coherence Tomography and Raman Spectroscopy for Sensing of the Bone Demineralization Process
PublikacjaThe presented research was intended to seek new optical methods to investigate the demineralization process of bones. Optical examination of the bone condition could facilitate clinical trials and improve the safety of patients. The authors used a set of complementary methods: polarization-sensitive optical coherence tomography (PS-OCT) and Raman spectroscopy. Chicken bone samples were used in this research. To stimulate in laboratory...
-
ANALYSIS OF BONE WEDGE DIMENSIONS SELECTION METHODS IN HIGH TIBIAL OSTEOTOMY
PublikacjaThe article presents the analysis of methods for selecting dimensions of bone wedge for high tibial osteotomy. The existing methods are described along with the procedure. In the following paragraphs, deficiencies in the selection of bone wedge dimensions and global trends in this field have been demonstrated. Based on the numerical analysis, the problem appearing in the wrong choice of bone wedge imensions was illustrated.
-
Antibacterial evaluation of bioactive modifiers of bone cements: antibiotics, nanometals and chitosan
PublikacjaModern biomaterials in addition to their basic tasks, can serve as carriers of active substance. The release of a bioactive particles allows to locally fight infection or its prevent it. Bone cements additionally to their basic applications in orthopedic surgery can also serve to deliver locally active substances. Currently, only antibiotics are routinely used as modifiers for bone cements. Bioactive bone cements constitute...
-
Design Evolution of the Ultrasonic Piezoelectric Motor Using Three Rotating Mode Actuators
PublikacjaThe development process and experimental investigation of the multicell piezoelectric motor is presented in this paper. The proposed design consists of three individual cells integrated into the stator, double rotor, and a preload system. Those elements are combined into a symmetrical structure of the motor. The two new prototypes have been designed, simulated and tested. Finite element numerical analysis is carried out to obtain...
-
Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaAbstrakt artykułu pt. ''Nanotubular Ti Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity''. The paper describes techniques to improve the bioactivity of titanium and ehnahnce the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotubular oxide layer.
-
Design of a continuous intra-oral distraction device for mandibular bone
PublikacjaIn this paper we present example of a specific device used for distraction osteogenesis. Distraction osteogenesis (also called callus distraction, collotasis or osteodistraction) is a surgical process for reconstructing bone deformities or lengthening bones.
-
Comment on permeability conditions in finite element simulation of bone fracture healing
PublikacjaThe most popular model of the bone healing considers the fracture callus as poroelastic medium. As such it requires an assumption of the callus’ external permeability. In this work a systematic study of the influence of the permeability of the callus boundary on the simulated bone healing progress is performed. The results show, that these conditions starts to play significant role with the decrease of the callus size. Typically...
-
Improving Output Performance of the Ultrasonic Multicell Piezoelectric Motor by Development the Multi-Rotor Structure
PublikacjaIn recent years, many researches have been carried out on piezoelectric multi-rotor structures. This paper describes the analysis, development and experimental process of an ultrasonic multi-cell piezoelectric motor using a multi-rotor structure. In this design, three independent cells have been integrated into a mechatronic system. Analytical model and finite element method are used for modal and dynamic analysis of the proposed...
-
Young’s modulus distribution in the FEM models of bone tissue
PublikacjaThis paper presents how differences of Young’s modulus in adjacent finite elements typical for organic materials such as bone tissue, influence stress calculating. Emphasizing high computational cost of variable Young’s modulus in parts of the model, where the number of finite elements has been raised, the authors wants to prove that new model of finite element which has variable Young’s modulus in its volume needs to be created....
-
Nanotubular Titanium Oxide Layers for Enhancement of Bone-Implant Bonding and Bioactivity
PublikacjaThe present paper describes the techniques to improve the bioactivity of titanium and enhance the bone-implant bonding ability by the electrochemical anodization to fabricate titania nanotube arrays (TiO2).
-
Experiments and numerical modeling of meat and bone meal pyrolysis in a rotary kiln
PublikacjaThe paper presents aspects of modelling the pyrolysis of meat and bone meal (MBM) in a rotary kiln. The pyrolysis of MBM produces a solid fraction which can be used as a fuel, a liquid fraction with potential chemical applications and a low heating value gas. The meat and bone meal pyrolysis was carried out at the temperature of 900 oC. Main features of experiments and numerical model of the pyrolysis were described. The model...
-
Design and Experiments of a Piezoelectric Motor Using Three Rotating Mode Actuators
PublikacjaThis paper represents a numerical and experimental investigation of the multicell piezoelectric motor. The proposed design consists of three individual cells that are integrated into the stator, double rotor, and a preload system combined into a symmetrical structure of the motor. Each of the cells is characterized by a traveling wave and rotating mode motor. A finite element numerical analysis is carried out to obtain optimal...
-
Amplitude-distance spectroscopy in semi-contact mode
Dane BadawczeSince it was invented by Binnig et al. in 1986, atomic force microscopy (AFM) plays a key role in science and technology at the nanoscale. AFM is a microscopic technique that visualizes the surface topography using the attractive and repulsive forces of interaction between several atoms (in theory) of a blade attached to the end of the probe lever and...
-
The Effect of Surface Modification of Ti13Zr13Nb Alloy on Adhesion of Antibiotic and Nanosilver-Loaded Bone Cement Coatings Dedicated for Application as Spacers
PublikacjaSpacers, in terms of instruments used in revision surgery for the local treatment of postoperative infection, are usually made of metal rod covered by antibiotic-loaded bone cement. One of the main limitations of this temporary implant is the debonding effect of metal–bone cement interface, leading to aseptic loosening. Material selection, as well as surface treatment, should be evaluated in order to minimize the risk of fraction...
-
[NCh, IMa] Properties of novel materials
Kursy Online{mlang pl} Dyscyplina: nauki chemiczne, inżynieria materiałowa Zajęcia fakultatywne Prowadzący: prof. dr hab. inż. T. Klimczuk, WFTiMS Liczba godzin: 15 Forma zajęć: wykład {mlang} {mlang en} Discipline: chemical sciences, materials engineering facultative course Academic teacher: prof. dr hab. inż. T. Klimczuk, WFTiMS Total hours of training:15 teaching hours Course type: lecture {mlang}
-
Implant system for treatment of the orbital floor defects of blowout fractures in the maxillofacial region using polypropylene yarn and bioactive bone cement
PublikacjaFractures in the craniofacial region are a serious problem in terms of treatment. The most reasonable solution is the use of individual implants dedicated to a specific patient. The aim of this study was to develop the implant system specifically for treatment of the orbital floor defects of blowout fractures of maxillofacial region, using polypropylene yarn and bone cement. Three types of bone cement were used to fix the polypropylene...
-
INTERNATIONAL JOURNAL OF FOOD PROPERTIES
Czasopisma -
Digestive system, femur and tibia bone characteristics of Dworka and Pekin ducks
PublikacjaThe aim of this study was to determine traits of the digestive system and femur and tibia bone ofDworka and Pekin ducks. A study was conducted on 24 Dworka duck (breeding strain D11) carcassesand 24 Pekin duck (conservative strain P9) carcasses, 12 male carcasses and 12 female carcassesfrom each strain. The lengths of the intestinal segments were tape measured. The diameters of theintestinal segments and leg bone dimensions...
-
Digestive system, femur and tibia bone characteristics of Dworka and Pekin ducks
PublikacjaThe aim of this study was to determine traits of the digestive system and femur and tibia bone ofDworka and Pekin ducks. A study was conducted on 24 Dworka duck (breeding strain D11) carcassesand 24 Pekin duck (conservative strain P9) carcasses, 12 male carcasses and 12 female carcassesfrom each strain. The lengths of the intestinal segments were tape measured. The diameters of theintestinal segments and leg bone dimensions...
-
Digestive system, femur and tibia bone characteristics of Dworka and Pekin ducks
PublikacjaThe aim of this study was to determine traits of the digestive system and femur and tibia bone ofDworka and Pekin ducks. A study was conducted on 24 Dworka duck (breeding strain D11) carcassesand 24 Pekin duck (conservative strain P9) carcasses, 12 male carcasses and 12 female carcassesfrom each strain. The lengths of the intestinal segments were tape measured. The diameters of theintestinal segments and leg bone dimensions...
-
Bone Research
Czasopisma -
Bone Reports
Czasopisma -
Ferroelectric LTCC tape for piezoelectric applications
PublikacjaOpisano opracowanie surowej taśmy LTCC do zastosowań piezoelektrycznych. Wybór bazuje na modyfikowanej lantanem kompozycji cyrkoniano-tytanioołowiu (PLZT). Opisano proces produkcji taśmy, wykonanie próbek ceramicznych z użyciem tej taśmy, zastosowane metody pomiarowe oraz dielektryczne i piezoelektryczne parametry wyprodukowanych próbek.
-
Modelling of Mechanical Behaviour of High-Frequency Piezoelectric Actuators Using Bouc-Wen Model
PublikacjaThe paper presents the application of a modified, symmetrical Bouc-Wen model to simulate a mechanical behaviour of high-frequency piezoelectric actuators (PAs). In order to identify parameters of the model, a two-step algorithm was utilized. In the first stage, the mechanical parameters were identified by taking into account their bilinear variability and using a square input voltage waveform. In the second step, the hysteresis...
-
Experimental and numerical studies on the mechanical response of a piezoelectric nanocomposite-based functionally graded materials
PublikacjaThis work presents an experimental study of piezoelectric structures reinforced by graphene platelets, based on the concept of the functionally graded materials (FGMs). The assumed model is a rectangular beam/plate and the composition is due to the Halpin-Tsai rule. The model is also simulated in the Abaqus software which is the first time that such a structure has been modelled in an FEM package. In addition, a mathematical model...
-
Electro-thermal buckling of elastically supported double-layered piezoelectric nanoplates affected by an external electric voltage
PublikacjaPurpose Thermal buckling of double-layered piezoelectric nanoplates has been analyzed by applying an external electric voltage on the nanoplates. The paper aims to discuss this issue. Design/methodology/approach Double-layered nanoplates are connected to each other by considering linear van der Waals forces. Nanoplates are placed on a polymer matrix. A comprehensive thermal stress function is used for investigating thermal buckling....
-
Cost-Effective and Sufficiently Precise Integration Method Adapted to the FEM Calculations of Bone Tissue
PublikacjaThe technique of Young’s modulus variation in the finite element is not spread in biomechanics. Our future goal is to adapt this technique to bone tissue strength calculations. The aim of this paper is to present the necessary studies of the element’s integration method that takes into account changes in material properties. For research purposes, a virtual sample with the size and distribution of mechanical properties similar...
-
Nonlinear finite element modeling of vibration control of plane rod-type structural members with integrated piezoelectric patches
PublikacjaThis paper addresses modeling and finite element analysis of the transient large-amplitude vibration response of thin rod-type structures (e.g., plane curved beams, arches, ring shells) and its control by integrated piezoelectric layers. A geometrically nonlinear finite beam element for the analysis of piezolaminated structures is developed that is based on the Bernoulli hypothesis and the assumptions of small strains and finite...
-
Injectable bone cement based on magnesium potassium phosphate and cross-linked alginate hydrogel designed for minimally invasive orthopedic procedures
PublikacjaBone cement based on magnesium phosphate has extremely favorable properties for its application as a bioactive bone substitute. However, further improvement is still expected due to difficult injectability and high brittleness. This paper reported the preparation of novel biocomposite cement, classified as dual-setting, obtained through ceramic hydration reaction and polymer cross-linking. Cement was composed of magnesium potassium...
-
Composite materials - fabrication, properties and prospects of application
Kursy Online -
Electro-mechanical shear buckling of piezoelectric nanoplate using modified couple stress theory based on simplified first order shear deformation theory
PublikacjaThis paper studies the electro-mechanical shear buckling analysis of piezoelectric nanoplate using modified couple stress theory with various boundary conditions.In order to be taken electric effects into account, an external electric voltage is applied on the piezoelectric nanoplate. The simplified first order shear deformation theory (S-FSDT) has been employed and the governing differential equations have been obtained using...
-
Cu-HKUST-1 and Hydroxyapatite–The Interface of Two Worlds toward the Design of Functional Materials Dedicated to Bone Tissue Regeneration
PublikacjaA novel composite based on biocompatible hydroxyapatite (HA) nanoparticles and Cu-HKUST-1 (Cu-HKUST-1@HA) has been prepared following a layer-by-layer strategy. Cu-HKUST-1 was carefully selected from a group of four Cu-based metal−organic frameworks as the material with the most promising antimicrobial activity. The formation of a colloidal Cu- HKUST-1 layer on HA nanoparticles was confirmed by various techniques, e.g., infrared...
-
The cement-bone bond is weaker than cement-cement bond in cement-in-cement revision arthroplasty. A comparative biomechanical study
PublikacjaThis study compares the strength of the native bone-cement bond and the old-new cement bond under cyclic loading, using third generation cementing technique, rasping and contamination of the surface of the old cement with biological tissue. The possible advantages of additional drilling of the cement surface is also taken into account. Femoral heads from 21 patients who underwent a total hip arthroplasty performed for hip arthritis...
-
Destruction of AFM probes during normal operation
Dane BadawczeThe quality of the images obtained with the use of an atomic force microscope is determined by the state of the blade interacting with the tested material. Image artifacts can be generated by various reasons, such as oxidation, contamination or an error in blade fabrication, but also appear as a result of the repeated scanning process and inevitable...
-
Thermal utilization of meat and bone meals. Performance analysis in terms of drying process, pyrolysis and kinetics of volatiles combustion
PublikacjaA development of technology of thermal utilization requires a thorough knowledge of the physicochemical properties, as well as kinetics of combustion of volatiles and char. Due to waste management regulations the meat and bone meal (MBM) is regarded as biofuel constituting one of the alternatives to fossil fuels in the energy market. MBM is a heterogeneous material that may consist of several different fractions. The extensive...
-
A facile approach to fabricate load-bearing porous polymer scaffolds for bone tissue engineering
PublikacjaBiodegradable porous scaffolds with oriented interconnected pores and high mechanical are load-bearing biomaterials for bone tissue engineering. Herein, we report a simple, non-toxic, and cost-effective method to fabricate high-strength porous biodegradable scaffolds, composed of a polymer matrix of polycaprolactone (PCL) and water-soluble poly (ethylene oxide) (PEO) as a sacrificial material by integrating annealing treatment,...
-
Daily oligofructose-enriched inulin intake impacts bone turnover markers but not the cytokine profile in pediatric patients with celiac disease on a gluten-free diet: Results of a randomised, placebo-controlled pilot study
Publikacja -
The Staged Combustion of Meat-and-Bone Meal:The Characteristics of Conversion Sub-processes and Large-Scale Process Outputs
Publikacjat Organic waste has been playing an increasingly important role in the energy market as those that may support the economies in pursuing towards decarbonization by increasing the share of renewables in the overall energy balance. In this group of alternative fuels, meat-and-bone meals being a post-production waste of the steadily developing meat industry, constitute a considerable proportion. Though they are rich in minerals, their...
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublikacjaRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
The SPM Scanner Head Based on Piezoelectric Unimorph Disc
Publikacja -
LTCC compatible PLZT thick-films for piezoelectric devices.
PublikacjaOpisano proces produkcji grubych warstw PLZT oraz pomiary ich dielektrycznych i piezoelektrycznych parametrów. Temperatura obróbki termicznej (850 stopni C) czyni te warstwy kompatybilnymi z technologią LTCC.
-
Aneurysmal bone cyst - Female, 14 - Tissue image [4270730007811401]
Dane BadawczeThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Aneurysmal bone cyst - Female, 14 - Tissue image [4270730007816471]
Dane BadawczeThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Aneurysmal bone cyst - Female, 14 - Tissue image [4270730007811321]
Dane BadawczeThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Aneurysmal bone cyst - Female, 14 - Tissue image [427073000781271]
Dane BadawczeThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Aneurysmal bone cyst - Female, 14 - Tissue image [4270730007816701]
Dane BadawczeThis is the histopathological image of BONES, JOINTS AND ARTICULAR CARTILAGE OF LIMBS tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Ultrasonic wave propagation and digital image correlation measurements of steel bars under 3-point bending
Dane BadawczeThe DataSet contains the results of the mechanical behaviour of a bar under a 3-point bending test. The bar was made of steel and had a cross-section of 5.96 × 5.96 mm2 and a length of 200 mm. The three-point bending test was performed using a Zwick/Roell Z10 universal testing machine (UTM), with a distance between supports of 12 cm. The parameters...