Filtry
wszystkich: 562
Wyniki wyszukiwania dla: CHEMICAL SENSOR
-
The effects of gas exposure on the graphene/AlGaN/GaN heterostructure under UV irradiation
PublikacjaThis work demonstrates a graphene/AlGaN/GaN sensing device with two-dimensional electron gas (2DEG) toward nitrogen dioxide (NO2), tetrahydrofuran, and acetone detection under UV light irradiation. We propose combining measurements of the DC characteristics with a fluctuation-enhanced sensing method to provide insight into the gas detection mechanisms in the synergistic structure of highly stable GaN and gas-sensitive graphene....
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublikacjaProperties of sensor based on Nasicon with two round shaped platinum electrodes are investigated. Influence of different chlorine concentrations on the sensor response is presented. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Influence of operation temperature instability on gas sensor performance
PublikacjaGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublikacjaIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
An optimized system for sensor ontology meta-matching using swarm intelligent algorithm
PublikacjaIt is beneficial to annotate sensor data with distinct sensor ontologies in order to facilitate interoperability among different sensor systems. However, for this interoperability to be possible, comparable sensor ontologies are required since it is essential to make meaningful links between relevant sensor data. Swarm Intelligent Algorithms (SIAs), namely the Beetle Swarm Optimisation Algorithm (BSO), present a possible answer...
-
Hydrogen sulphide electrocatalytic gas sensor
PublikacjaIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
Gas sensors based on conducting polymers-recent developments
PublikacjaThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublikacjaIn this work amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode will be presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been investigated.
-
Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties
PublikacjaIn this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublikacjatIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
A Microwave Sensor with Operating Band Selection to Detect Rotation and Proximity in the Rapid Prototyping Industry
PublikacjaThis paper presents a novel sensor for detecting and measuring angular rotation and proximity, intended for rapid prototyping machines. The sensor is based on a complementary split-ring resonator (CSRR) driven by a conductor-backed coplanar waveguide. The sensor has a planar topology, which makes it simple and cost-effective to produce and accurate in measuring both physical quantities. The sensor has two components, a rotor, and...
-
Tailoring properties of indium tin oxide thin films for their work in both electrochemical and optical label-free sensing systems
PublikacjaThis work is devoted to the identification properties of indium tin oxide (ITO) thin films responsible for their possible application in combined optical and electrochemical label-free sensing systems offering enhanced functionalities. Since any post-processing would make it difficult to identify direct relation between deposition parameters and properties of the ITO films, especially when deposition on temperature-sensitive substrates...
-
Polypyrrole based gas sensor for ammonia detection
PublikacjaThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
On a design of a torque sensor for the iCub humanoid robot
PublikacjaThe paper presents the evaluation process of a first version of the one axis torque sensor designed for the iCub humanoid robot. Newly designed strain gauges equipped sensor was found to show a significant readouts hysteresis, therefore several tests were run to define the reason of the hysteresis. Some of the design issues met while testing the new sensor are discussed including the screws connection and relative rigidity of the...
-
Spectroscopic wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
Enhanced Eye-Tracking Data: a Dual Sensor System for Smart Glasses Applications
PublikacjaA technique for the acquisition of an increased number of pupil positions, using a combined sensor consisting of a low-rate camera and a high-rate optical sensor, is presented in this paper. The additional data are provided by the optical movement-detection sensor mounted in close proximity to the eyeball. This proposed solution enables a significant increase in the number of registered fixation points and saccades and can be used...
-
A Compact and Lightweight Microwave Tilt Sensor Based on an SRR-Loaded Microstrip Line
PublikacjaIn this paper, the symmetry property of split ring resonators (SRRs) is exploited to develop a tilt sensor. The sensor is composed of an SRR-loaded microstrip line operating at microwave frequencies. It is shown that the depth of notch in the reflection characteristic of the microstrip is a function of the tilt angle of the SRR. Thus, it can be used for sensing inclination. The sensor benefits from very compact size and light weight....
-
Design and Experimental Validation of a Metamaterial-Based Sensor for Microwave Imaging in Breast, Lung, and Brain Cancer Detection
PublikacjaThis study proposes an innovative geometry of a microstrip sensor for high-resolution microwave imaging (MWI). The main intended application of the sensor is early detection of breast, lung, and brain cancer. The proposed design consists of a microstrip patch antenna fed by a coplanar waveguide with a metamaterial layer-based lens implemented on the back side, and an artificial magnetic conductor (AMC) realized on as a separate...
-
A Highly Sensitive Planar Microwave Sensor for Detecting Direction and Angle of Rotation
PublikacjaThis article presents a technique based on a modified complementary split-ring resonator (CSRR) to detect angular displacement and direction of rotation with high resolution and sensitivity over a wide dynamic range. The proposed microwave planar sensor takes advantage of the asymmetry of the sensor geometry and measures the angle of rotation in terms of the change in the relative phase of the reflection coefficients. The sensor...
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublikacjaThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
Electrocatalytic Gas Sensor with Reference Layer
PublikacjaThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
A method of measuring RLC components for microcontroller systems
PublikacjaA new method of measuring RLC components for microcontroller systems dedicated to compact smart impedance sensors based on a direct sensor-microcontroller interface is presented. In the method this direct interface composed of a reference resistor connected in series with the tested sensor impedance is stimulated by a square wave generated by the microcontroller, and then its voltage response is sampled by an internal ADC of the...
-
Interactions using passive optical proximity detector
PublikacjaIn this paper we evaluated the possible application of a passive, optical sensor as an interface for human-smart glasses interactions. The designed proximity sensor is composed of set of photodiodes and the appropriate hardware and software components. First, experiments were performed for the estimations of such parameters as distance to an object, its width and velocity. Achieved results were satisfactory. Therefore, next, a...
-
Impact of temperature on optical sensing in biology based on investigation of SARS‐CoV ‐2
PublikacjaIn this paper, we present an investigation of the influence of the temperature on the sensing of biological samples. We used biofunctionalized microsphere-based fiber-optic sensor to detect immunoglobulin G attached to the sensor head at temperatures relevant in biological research: 5°C, 25°C, and 55°C. The construction of the sensor allowed us to perform measurements in the small amount of solution. The results of our experiment...
-
Investigation of the temperature modulation parameters on semiconductor gas sensor response
PublikacjaIn this work we present the results of the investigation of the sensing properties of semiconductor gas sensors with a sinusoidally modulated temperature in the presence of synthetic air (SA) and three volatile air pollutants, i.e. NH3, NO2 and SO2. The measurements were performed for different average sensor heater temperatures and the amplitude of the modulation signal. In addition, the extraction of features from the sensor...
-
SAMPLE-AND-HOLDING METHOD FOR GAS SENSING APPLIED FOR RESISTANCE GAS SENSORS
PublikacjaThe DC resistance of a Taguchi gas sensor is influenced by the ambient gas. To improve the selectivity and sensitivity of a sensor the fluctuation enhanced sensing (FES) was used. The paper proposes a novel methodology of utilizing FES technique that sample composition of an ambient atmosphere and hold it for further processing (sample-and-holding technique). The method uses the heated gas sensor to sample an ambient atmosphere...
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublikacjaA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Wireless multimodal localization sensor for industrial applications
PublikacjaThis paper presents the concept and design of a wireless multimodal localization sensor for hybrid localization systems combining vision-based, radio-based and inertial techniques in order to alleviate problems in harsh and complex industrial environments. It supports two radio technologies, 868 MHz UHF RFID and 2.4 GHz WSN, for positioning purposes and communications. The sensor includes LED light transmitters for vision-based...
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublikacjaThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublikacjaIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Semi complex navigation with an active optical gesture sensor
PublikacjaThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
ZnO ALD-Coated Microsphere-Based Sensors for Temperature Measurements
PublikacjaIn this paper, the application of a microsphere-based fiber-optic sensor with a 200 nm zinc oxide (ZnO) coating, deposited by the Atomic Layer Deposition (ALD) method, for temperature measurements between 100 and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor head in real-time, which allows for higher accuracy during...
-
Utilization of a Non-Linear Error Function in a Positioning Algorithm for Distance Measurement Systems Designed for Indoor Environments
PublikacjaA new positioning algorithm for distance measurement systems is outlined herein. This algorithm utilizes a non-linear error function which allows us to improve the positioning accuracy in highly difficult indoor environments. The non-linear error function also allows us to adjust the performance of the algorithm to the particular environmental conditions. The well-known positioning algorithms have limitations, mentioned by their...
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublikacjaIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublikacjaIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Spectroscopic and wireless sensor of hematocrit level
PublikacjaAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.
-
Techniques of acquiring additional features of the responses of individual gas sensors
PublikacjaGas sensors usually exhibit lack of selectivity, require fre quent calibration, exhibit drift of the response and a lot of factors, such as humidity or ambient temperature, influen ce their performance. Different approaches can be used to overcome this shortcomings. Building arrays of different sensors and usage of pattern recognition methods to analyze responses of elements...
-
Methodology for assessing end-user requirements in the Ella4Life project: elders’ perspectives about self-monitoring
PublikacjaThe purpose of this paper is to explore elders’ perspectives about self-monitoring and using specially developed sensor technology for measuring health indicators. The qualitative research method is focus-groups with guidelines that were designed for understanding elder’s requirements about monitoring health indicators. We present them two devices: the first sensor is a device for monitoring of cardiac action potential fixed into...
-
Fluctuation enhanced gas sensing using UV irradiated Au-nanoparticle-decorated WO3-nanowire films
PublikacjaWO3 nanowires (WO3-NWs) decorated with gold nanoparticles (AuNPs) were utilized in resistive gas sensor devices to detect ethanol by use of fluctuation enhanced sensing (FES). The experimental system records both DC resistance and fluctuations of the sensing film. Our data verify that the sensitivity and selectivity of the gas sensor are improved by applying FES when the sensor is stimulated with a combination of UV light and heating....
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublikacjaA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
Qualitative and Quantitative Analysis of Selected Tonic Waters by Potentiometric Taste Sensor With All-Solid-State Electrodes
PublikacjaTaste sensor with five all-solid-state electrodes (ASSE) III (third version) was used for qualitative and quantitative analysis of selected tonic waters (J.Gasco, Kinley, Jurajski, Jurajski with citrus flavor, Carrefour, Schweppes Indian Tonic, and Schweppes Bitter Lemon). The results obtained by this taste sensor analyzed with principal component analysis, agglomerative hierarchical clustering methods show that this sensor can...
-
QUASI-DISTRIBUTED NETWORK OF LOW-COHERENCE FIBER-OPTIC FABRY-PÉROT SENSORS WITH CAVITY LENGTH-BASED ADDRESSING
PublikacjaDistributed measurement often relies on sensor networks. In this paper, we present the construction of low coherent fiber-optic Fabry-Pérot sensors connected into a quasi-distributed network. We discuss the mechanism of spectrum modulation in this type of sensor and the constraints of assembly of such sensors in the network. Particular attention was paid to separate the signals from individual sensors, which can be achieved by...
-
Towards Contactless, Hand Gestures-Based Control of Devices
PublikacjaGesture-based intuitive interactions with electronic devices can be an important part of smart home systems. In this paper, we adapt the contactless linear gesture sensor for the navigation of smart lighting system. Set of handled gestures allow to propose two methods of active light source selection, continuous dimming, and turning on and off based on discrete gestures. The average gesture recognition accuracy was 97.58% in the...
-
Microwave Alignment and Displacement Sensors in Groove Gap Waveguide Technology
PublikacjaThis paper is aimed at presenting highly sensitive microwave displacement and alignment sensors. With this goal, the method of realizing mechanically tunable cavity resonators in groove gap waveguides technology is presented. The resonance frequency of the cavity is then used for displacement sensing. It is also demonstrated that the symmetry properties of a pair of groove gap waveguide cavities can be used to improve the robustness...
-
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
PublikacjaThis article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane...
-
On Rapid Design Optimization and Calibration of Microwave Sensors Based on Equivalent Complementary Resonators for High Sensitivity and Low Fabrication Tolerance
PublikacjaThis paper presents the design, optimization, and calibration of multivariable resonators for mi-crowave dielectric sensors. An optimization technique for circular complementary split ring reso-nator (CC-SRR) and square complementary split ring resonator (SC-SRR) is presented to achieve the required transmission response in a precise manner. The optimized resonators are manufac-tured using a standard photolithographic technique...
-
Optical-Fiber Microsphere-Based Temperature Sensors with ZnO ALD Coating—Comparative Study
PublikacjaThis study presents the microsphere-based fiber-optic sensor with the ZnO Atomic Layer Deposition coating thickness of 100 nm and 200 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range from 100 °C to 300 °C, with a 10 °C step. The interferometric signal was used to monitor the integrity of the microsphere and its attachment to the connecting fiber. For the sensor...
-
Identification of the mechanical properties of the skin by electromechanical impedance analysis of resonant piezoelectric actuator
PublikacjaThis paper is devoted to the analysis and verification of developed piezoelectric sensor/actuator for measuring the mechanical properties of soft tissues, especially human skin. The key element of the measurement structure is an electromechanical system that uses both the reverse piezoelectric effect (vibration generation – stimulation of the tissues in the appropriate frequency range) and direct piezoelectric effect (system response...
-
Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement
PublikacjaDoppler sensors are commonly used for movement detection and speed measurement. However, electromagnetic interference and imperfections in sensor construction result in degradation of the signal to noise ratio. As a result, detection of signals reflected from moving objects becomes problematic. The paper proposes an algorithm for reduction of distortions and noise in the signal received from a simple, dual-channel type of a Doppler...
-
Novel MNZ-type microwave sensor for testing magnetodielectric materials
PublikacjaA novel microwave sensor with the mu-near-zero (MNZ) property is proposed for testing magnetodielectric material at 4.5 GHz. The sensor has a double-layer design consisting of a microstrip line and a metal strip with vias on layers 1 and 2, respectively. The proposed sensor can detect a unit change in relative permittivity and relative permeability with a difference in the operating frequency of 45 MHz and 78 MHz, respectively....