Wyniki wyszukiwania dla: PULS
-
The concept of a new two-stage fuse for high power pulse forming
PublikacjaThis manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...
-
Effects of laser pulse duration in two-photon vision threshold measurements
PublikacjaPulsed near-infrared (NIR) light sources can be successfully applied for both imaging and functional testing of the human eye, as published recently1. These two groups of applications have different requirements. For imaging applications, the most preferable is invisible scanning beam while efficiently visible stimulating beam is preferable for functional testing applications. The functional testing of human eye using NIR laser...
-
Sonar Pulse Detection Using Chirp Rate Estimation and CFAR Algorithms
PublikacjaThis paper presents a new approach to sonar pulse detection. The method uses chirp rate estimators and algorithms for the adaptive threshold, commonly used in radiolocation. The proposed approach allows detection of pulses of unknown parameters, which may be used in passive hydrolocation or jamming detection in underwater communication. Such an analysis is possible thanks to a new kind of imaging, which presents signal energy in...
-
A Meta-Analysis of Pulse Arrival Time Based Blood Pressure Estimation
PublikacjaThe paper presents a preliminary meta-analysis of the sample correlation between pulse arrival time (PAT) and blood pressure (BP). The aim of the study was to verify sample correlation coefficient between PAT and BP using an affine model BP = a · P AT + b for systolic and diastolic blood pressure. The databases included in the search were the IEEE Xplore Digital Library, Springer Link and Google Scholar. Only papers from 2005 to...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublikacjaNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Current divider-based nanosecond high current pulse measuring systems
PublikacjaThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Evaluation of Facial Pulse Signals Using Deep Neural Net Models
PublikacjaThe reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...
-
Effect of nitrogen doping on TiOxNythin film formation at reactive high-power pulsed magnetron sputtering
Publikacja -
Alternative Local Melting-Solidification of Suspended Nanoparticles for Heterostructure Formation Enabled by Pulsed Laser Irradiation
Publikacja -
Influence of Acute Jugular Vein Compression on the Cerebral Blood Flow Velocity, Pial Artery Pulsation and Width of Subarachnoid Space in Humans
PublikacjaCelem pracy jest zaprezentowanie wyników badań dotyczących oceny wpływu silnego obustronnego zwężenia żył szyjnych na amplitudę pulsacji i zmiany szerokości przestrzeni podpajęczynówkowej, prędkość przepływu mózgowego krwi, obwodowe ciśnienie krwi oraz możliwe relacje między wymienionymi parametrami.
-
Effect of Maximal Apnoea Easy-Going and Struggle Phases on Subarachnoid Width and Pial Artery Pulsation in Elite Breath-Hold Divers
PublikacjaPurpose: The aim of the study was to assess changes in subarachnoid space width (sas-TQ), the marker of intracranial pressure (ICP), pial artery pulsation (cc-TQ) and cardiac contribution to blood pressure (BP), cerebral blood flow velocity (CBFV) and cc-TQ oscillations throughout the maximal breath hold in elite apnoea divers. Non-invasive assessment of sas-TQ and cc-TQ became possible due to recently developed method based on...
-
[PP.17.01] INCREASED INSPIRATORY RESISTANCE AFFECTS THE CARDIAC CONTRIBUTION TO THE RELATIONSHIP BETWEEN BLOOD PRESSURE AND PIAL ARTERY PULSATION OSCILLATIONS
PublikacjaThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance would affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
Kinetics of molecular decomposition under irradiation of gold nanoparticles with nanosecond laser pulses—A 5-Bromouracil case study
Publikacja -
Kinetics of molecular decomposition under irradiation of gold nanoparticles with nanosecond laser pulses—A 5-Bromouracil case study
PublikacjaABSTRACT Laser illuminated gold nanoparticles (AuNPs) efficiently absorb light and heat up the surrounding medium, leading to versatile applications ranging from plasmonic catalysis to cancer photothermal therapy. Therefore, an in-depth understanding of the thermal, optical, and electron induced reaction pathways is required. Here, the electrophilic DNA nucleobase analog 5-Bromouracil (BrU) has been used as a model compound to...
-
Symulacja obwodów elektrycznych zasilanych pulsacyjnie w badaniach patologii nerek. Zastosowanie Komputerów w Nauce i Technice.XIII cykl seminariów zorganizowanych przez PTETiS, Oddział Gdańsk.
PublikacjaPrzedstawiono istotę odwzorowania krwiobiegu nerki za pomocą prostego obwodu elektrycznego. Podano wpływ zmiany oporów przepływu krwi na współczynnik oporu RI w nerce.
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublikacjaIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Method using square-pulse excitation for high-impedance spectroscopy of anticorrosion coatings
PublikacjaArtykuł prezentuje metodę spektroskopii impedancyjnej przeznaczonej do diagnostyki powłok antykorozyjnych na obiektach bezpośrednio w terenie. Aby skrócić czas uzyskania widma impedancji (w zakresie od 1 mHz do 1 MHz) do kilku minut, wykorzystano sygnały harmoniczne do pomiaru widma powyżej 10 Hz a impuls prostokątny w dolnym zakresie częstotliwości. Do wyznaczania widma użyto algorytmów DSP odpowiednich do sygnału pobudzenia....
-
Ambulatory pulse pressure and its contributors in autosomal dominant polycystic kidney disease
Publikacja -
Pulse wave velocity is associated with early clinical outcome after ischemic stroke
Publikacja -
Pulse wave velocity to the global longitudinal strain ratio in survivors of myocardial infarction
Publikacja -
Numerical modelings of ultrashort pulse propagation and conical emission in multimode optical fibers
Publikacja -
Recurrent potential pulse technique for improvement of glucose sensing ability of 3D polypyrrole
PublikacjaIn this work, a new approach for using a 3D polypyrrole (PPy) conducting polymer as a sensing material for glucose detection is proposed. Polypyrrole is electrochemically polymerized on a platinum screen-printed electrode in an aqueous solution of lithium perchlorate and pyrrole. PPy exhibits a high electroactive surface area and high electrochemical stability, which results in it having excellent electrocatalytic properties. The...
-
Heating caused by a non periodic ultrasound. Theory and calculations on pulse and stationary sources.
PublikacjaPrzedstawiono teorię ewolucji ogrzewania na skutek przejścia fali akustycznej każdego typu. Przedyskutowano obliczenia na podstawie nowych wzorów dla fali impulsowej i uderzeniowej. Wzory zgadzają się z klasycznymi w wypadku fal okresowych.
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublikacjaIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
SiC-based T-type modules for multi-pulse inverter with coupled inductors
PublikacjaThe paper presents SiC-based three-level T-type modules designed for a high-performance 30kVA DC/AC inverter operating at high frequency 85 kHz with low THD of the output voltage. This inverter system consists of two integrated parts. The first part is active and contains three parallelconnected three-phase T-type modules built with fast-switching SiC power transistors. The second, passive part of the system is a set of inductors...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublikacjaAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Effect of nitrogen doping on TiOxNy thin film formation at reactive high-power pulsed magnetron sputtering
PublikacjaThe paper is focused on a study of formation of TiOxNy thin films prepared by pulsed magnetron sputtering of metallic Ti target. Oxygen and nitrogen were delivered into the discharge in the form of reactive gases O2 and N2. The films were deposited by high-power impulse magnetron sputtering working with discharge repetition frequency f = 250 Hz at low (p = 0.75 Pa) and high (p = 10 Pa) pressure. The substrates were on floating...
-
Thermomagnetic behavior of a semiconductor material heated by pulsed excitation based on the fourth-order MGT photothermal model
PublikacjaThis article proposes a photothermal model to reveal the thermo-magneto-mechanical properties of semiconductor materials, including coupled diffusion equations for thermal conductivity, elasticity, and excess carrier density. The proposed model is developed to account for the optical heating that occurs through the semiconductor medium. The Moore–Gibson–Thompson (MGT) equation of the fourth-order serves as the theoretical framework...
-
The In-Depth Studies of Pulsed UV Laser-Modified TiO2 Nanotubes: The Influence of Geometry, Crystallinity, and Processing Parameters
PublikacjaThe laser processing of the titania nanotubes has been investigated in terms of morphology, structure, and optical properties of the obtained material. The length of the nanotubes and crystallinity, as well as the atmosphere of the laser treatment, were taken into account. The degree of changes of the initial geometry of nanotubes were checked by means of scanning electron microscopy, which visualizes both the surface and the cross-section....
-
The pulsed laser ablation synthesis of colloidal iron oxide nanoparticles for the enhancement of TiO2 nanotubes photo-activity
PublikacjaThe rapid, only a few minutes long synthesis of FeO, Fe3O4, and Fe2O3nanoparticles mixture utilizing the pulsedlaser ablation using simply pure iron target and water was demonstrated. The size and crystal phase of Fe-basedNPs were characterized using DLS and HR-TEM techniques, respectively. The metastable suspension of FeO,Fe3O4, and Fe2O3nanoparticles was used to the decoration of anodized TiO2nanotubes (TiO2-NTs) by means ofthe...
-
Sympathetic Activation Does Not Affect the Cardiac and Respiratory Contribution to the Relationship between Blood Pressure and Pial Artery Pulsation Oscillations in Healthy Subjects
PublikacjaUsing a novel method called near-infrared transillumination backscattering sounding (NIR-T/BSS) that allows for the non-invasive measurement of pial artery pulsation (cc-TQ) and subarachnoid width (sas-TQ) in humans, we assessed the influence of sympathetic activation on the cardiac and respiratory contribution to blood pressure (BP) cc-TQ oscillations in healthy subjects. The pial artery and subarachnoid width response to handgrip...
-
Increased inspiratory resistance alters the cardiac contribution to the dynamic relationship between blood pressure and pial artery pulsation oscillations in healthy subjects
PublikacjaThere is increasing evidence that heart performance directly influences cerebral perfusion. We hypothesised that increased inspiratory resistance will affect the cardiac contribution to the relationship between blood pressure and pial artery pulsation oscillations.
-
A hybrid, coupled reactors based 18-pulse diode rectifier with active power filter
Publikacja -
Digital processing of pulse signal from light-to-frequency converter under dynamic condition
Publikacja -
The use of a static electrical energy meter as a transducer of active power to a pulse frequency signal
Publikacja -
Measurement of pulse signal period from incremental encorder by counters of Multifunctuin DAQ devices.
PublikacjaW artykule omówiono parametry liczników znajdujących się na wielofunkcyjnych kartach akwizycji sygnałów pomiarowych. Przedstawiono przygotowane w środowisku programowania Lab VIEW aplikacje wykorzystujące te liczniki. Służą one do pomiaru i rejestracji długości zadanej liczby okresów mierzonego sygnału oraz liczby okresów uzależnionej od ich długości (metoda zliczania zależnego z wydłużonym czasem pomiaru). Aplikacje te zostały...
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublikacjaThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublikacjaIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Application of Analytic Signal and Smooth Interpolation in Pulse Width Modulation for Conventional Matrix Converters
PublikacjaThe paper proposes an alternative and novel approach to the PWM duty cycles computation for Conventional Matrix Converters (CMC) fed by balanced, unbalanced or non–sinusoidal AC voltage sources. The presented solution simplifies the prototyping of direct modulation algorithms. PWM duty cycles are calculated faster by the smooth interpolation technique, using only vector coordinates, without trigonometric functions and angles. Both...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublikacjaThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Giant increase of optical transparency for Zn-rich CaxZn1−xO on Al2O3 (0001) grown by pulsed laser deposition
Publikacja -
Organic pollutants photodegradation increment with use of TiO2 nanotubes decorated with transition metals after pulsed laser treatment
PublikacjaAmong various titanium(IV) oxide (TiO2, titania) structures, 1D nanotubes (TiO2 NTs) produced during the two-electrode anodization process, are extensively utilized in sensors or supercapacitors as well as in photo(electro)catalytic water splitting. However, due to wide bandgap and fast electron-hole recombination additional modifications, mostly concerned on materials surface, are required. According to the recent research, TiO2...
-
Application of ion chromatography with pulsed amperometric detection for the determination of trace cyanide in biological samples, including breast milk
PublikacjaCyanide (CN) is the biomarker of exposure to the components of tobacco smoke, although its presence in biological samples is also due to the consumption of products containing cyanogenic glycosides. In this work, we determine the concentration of the free cyanide in urine, saliva and breast milk matrices, using ion chromatography with pulsed amperometric detection (IC-PAD). IC-PAD is an emerging method, with only few documented...
-
Tuning of the Electrochemical Properties of Transparent Fluorine-doped Tin Oxide Electrodes by Microwave Pulsed-plasma Polymerized Allylamine
PublikacjaWe report here the dry, one-step, and low-temperature modification of FTO surfaces using pulsed plasma polymerization of allylamine (PPAAm). PPAAm/FTO surfaces were characterized by X-ray photoelectron spectroscopy, spectroscopic ellipsometry, and contact angles to understand the morphological, structural, and optical properties. FTO were coated with a very thin layer of adherent cross-linked, pinhole-, and additive-free allylamine...
-
Pulsed Laser Deposition of Bismuth Vanadate Thin Films—The Effect of Oxygen Pressure on the Morphology, Composition, and Photoelectrochemical Performance
PublikacjaThin layers of bismuth vanadate were deposited using the pulsed laser deposition technique on commercially available FTO (fluorine-doped tin oxide) substrates. Films were sputtered from a sintered, monoclinic BiVO4 pellet, acting as the target, under various oxygen pressures (from 0.1 to 2 mbar), while the laser beam was perpendicular to the target surface and parallel to the FTO substrate. The oxygen pressure strongly affects...
-
Synthesis of Micro-Spikes and Herringbones Structures by Femtosecond Laser Pulses on a Titanium Plate—A New Material for Water Organic Pollutants Degradation
Publikacja -
An independent relationship between muscle sympathetic nerve activity and pulse wave velocity in normal humans
Publikacja -
Augmentation index, pulse pressure amplification and superoxide anion production in patients with coronary artery disease
Publikacja -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publikacja -
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublikacjaOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...