Electrochemical determination of nitroaromatic explosives at boron-doped diamond/graphene nanowall electrodes: 2,4,6-trinitrotoluene and 2,4,6-trinitroanisole in liquid effluents
PublikacjaThe study is devoted to the electrochemical detection of trace explosives on boron-doped diamond/graphene nanowall electrodes (B:DGNW). The electrodes were fabricated in a one-step growth process using chemical vapour deposition without any additional modifications. The electrochemical investigations were focused on the determination of the important nitroaromatic explosive compounds, 2,4,6-trinitrotoluene (TNT) and 2,4,6-trinitroanisole...
-
JOURNAL OF RAMAN SPECTROSCOPY
Czasopisma -
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Linear impedance of vanadate glasses containing BaTiO3
Dane BadawczeThe linear impedance of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
Impedance spectra of ZnO varistor type 680 model A M ver. 93
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 680 model A M ver. xx
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model 0 ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 100 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 440 model O ver. 68
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 10 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Impedance spectra of ZnO varistor type 280 model O M ver. 89
Dane BadawczeThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Instantaneous impedance spectra of a non-stationary model electrical system
Publikacja -
Optimization of impedance measurements using ‘chirp’ type perturbation signal
Publikacja -
The application of impedance measurements for the determination of the probability of the course of corrosion processes
Publikacja -
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
Publikacja -
Optimization of impedance measurements using ''chirp'' type perturbation signal
PublikacjaW pracy przedstawiono innowacyjny sposób pomiaru impedancji przy użyciu sygnału niestacjonarnego "chirp". W procesie akwizycji pobudzenia i odpowiedzi prądowej zastosowano zmienną częstotliwość próbkowania. Podejście takie pozwala zarówno na wielokrotne zmniejszenie ilości niezbędnych do otrzymania widma impedancyjnego rejestrowanych danych jak również upraszcza i przyspiesza proces obliczeniowy. Stwierdzono iż dokładność wyników...
-
On-line measurement of cell impedance during charging and discharging process
PublikacjaW pracy przedstawiono założenia metody pomiaru impedancji, która w przeciwieństwie do dotychczasowych technik impedancyjnych stosowanych w badaniach ogniw, umożliwia pracę on-line. W celu zaprezentowania możliwości metody wykonano eksperyment polegający na cyklicznym ładowaniu i rozładowywaniu elektrody ołowianej w 4.8M H2SO4 z jednoczesnym pomiarem impedancji. Zmiany parametrów elektrycznych otrzymanych w wyniku analizy widm impedancyjnych...
-
Identification and localization of organic coating degradation onset by impedance imaging
Publikacja -
Dual-Frequency Induction Heating Generator With Adjustable Impedance Matching
Publikacja -
Impedancyjne badanie korozji wżerowej. Impedance measurements of pitting corrosion
PublikacjaKryteria zachodzenia korozji wżerowej związane są z badaniami tego zjawiska metodą cyklicznej polaryzacji i opierają się na wartości gęstości prądu lub bezwzględnej wartości prądu płynącego w układzie. Na podstawie przeglądu literaturowego wybrano cztery kryteria stosowane przy badaniu stali stopowych metodą cyklicznej polaryzacji. Dla warunków prądowych odpowiadających kryteriom zachodzenia korozji wżerowej przedstawiono widma...
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublikacjaSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
PublikacjaW niniejszej pracy przeprowadzono badania elektrochemiczne powierzchniowego efektu PLC, związanego z nierównomiernym procesem płynięcia plastycznego stopów aluminium zawierających magnez. Występujący efekt PLC w postaci serration wywołuje niehomogeniczny proces zmian zewnętrznej powierzchni rozciąganej próbki. Wykonano badania metodą Dynamicznej Spektroskopii Impedancyjnej w warunkach dynamicznych prowadzenia procesu rozciągania....
-
Application of different modes of nanoscale impedance microscopy in materials research
Publikacja -
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublikacjaW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
The Goertzel filter-bank usage in the non-stationary impedance measurement.
PublikacjaArtykuł prezentuje metodę pomiaru parametrów impedancyjnych w warunkach niestacjonarnych bazującą na próbkowaniu sygnałów pomiarowych i przetwarzaniu cyfrowym. Zaproponowano i przeanalizowano zastosowanie banku filtrów Goertzela. Porównano zaproponowane podejście z tradycyjnie stosowaną metodą STDFT. Przedstawiono wynik symulacji i pomiarów.
-
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublikacjaBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
The influence of parameters of input probe on the error of high impedance measurement
PublikacjaW artykule przedstawiono sondę do pomiaru wysokich impedancji w zakresie 1kohm<|Zx|<100Gohm przeznaczoną do dołączenia do analizatorów typu gain-phase. Przeanalizowano wpływ parametrów sondy (pojemności pasożytnicze, toleranca rezystorów określających wzmocnienie wzmacniacza) na dokładność wyznaczenia modułu i argumentu zespolonego stosunku sygnałów wydzielonych w sondzie. Zamieszczono wyniki symulacji i pomiarów, pozwalające na...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublikacjaThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
The contribution of blood-flow-induced conductivity changes to measured impedance
PublikacjaW pracy rozwazane sa zmiany przewodnosci zachodzace w anizotropowym osrodku i ich wplyw na mierzona rezystancje. Uzyskano to za pomoca rozszerzenia wzoru Geselowizta na przypadki anizotropowe. Wykazano, ze tylko te skladowe zmian przewodnosci wplywaja na mierzona rezystancje, dla ktorych odpowiadajacy im skladnik pola eklektrycznego byl niezerowy.Wyniki te zastosowanu do zmian rezystywnosci wywolanych zmiananmi przewodnosci plynacej...
-
APPLICATION OF NON-STATIONARY TECHNIQUES IN THE ANALYSIS OF ELECTROCHEMICAL NOISE
Publikacja -
Electrochemical and acoustic emission studies of aluminum pitting corrosion
Publikacja -
Electrodes criticality: the impact of CRMs in the leachate electrochemical oxidation
Publikacja -
Graphene-based electrochemical biosensing system for medical diagnostics
Publikacja -
Electrochemical sensor for measurement of volatile organic compounds in air
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
Electrochemical and acoustic emission studies of aluminium pitting corrosion
PublikacjaBadania metodą potencjokinetyczną i emisjii akustycznej przeprowadzono w typowej trójelektrodowej celce elektrochemicznej. Elektrodę badaną przygotowano z stopu aluminium 1050A. Badania metodą cyklicznej polaryzacji i emisjii akustycznej wykonywano jednocześnie. Na podstawie wyników akustycznych i polaryzacyjnych wyznaczono potencjał korozji wzerowej.
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Electrochemical noise analysis methods for the investigation of corrpsion processes
PublikacjaProcesy korozji mogą być badane przez obserwacje przepływu ładunków między elektrolitem a korodującą elektrodą metalową. Przepływy te są obserwowane jako fluktuacje prądu i napięcia nazywane szumem elektrochemicznym. Różne rodzaje procesów korozji mogą być identyfikowane za pomocą szumów elektrochemicznych. Szybkość korozji jednorodnej jest określana przez estymację rezystancji polaryzacji występującej między elektrolitem a metalem....
-
On accurracy of polarization resistance estimation by electrochemical noise measurements
PublikacjaPrzedstawiono sposób estymacji rezystancji polaryzacji, wykorzystywanej do oceny szybkości procesów korozji. Zaproponowano formułę określającą błąd losowy estymacji rezystancji polaryzacji. Przytoczono i przedyskutowano eksperymentalne wyniki estymacji rezystancji polaryzacji na podstawie pomiarów szumów elektrochemicznych w układzie trzech elektrod pomiarowych.
-
Analysis of spontaneous electrochemical oscillations by the wavelet transformation method.
PublikacjaW pracy została przedstawiona nowa metoda analizy oscylacji prądu, które związane są z anodowym roztwarzaniem metali. Transformacja falkowa jest używana do rozdzielenia i analizy spektralnej pojedynczych przebiegów elementarnych komponentów oscylacji elektronicznych. Zastosowana została metoda rozkładu energii oscylacji analogiczna do funkcji spektralnej gęstości mocy.Wykazano, że chaotyczne składniki (chaos Shilnikova)...
-
Analysis of spontaneous electrochemical oscillations by energy distribution technique
PublikacjaAnaliza niestacjonarnych oscylacji elektrochemicznych wskazuje na konieczność stosowania technik umożliwiających śledzenie zmian w czasie takich parametrów oscylacji jak częstotliwość, amplituda, pasmo częstotliwościowe. Algorytm prowadzący do uzyskania tych parametrów może być oparty o jeden z liniowych lub kwadratowych sposobów przedstawienia rejestru oscylacji w dziedzinie czasu i częstotliwości. W pracy autorzy przedstawiają...
-
On electrochemical noise analysis for monitoring of uniform corrosion rate
PublikacjaSzybkość korozji jest określona przez rezystancję polaryzacyjną warstwy metal-elektrolit. Jej wartość może być wyznaczona za pomocą pomiarów szumów elektrochemicznych. Przedstawiono szczegółowo algorytm wyznaczania wartości rezystancji polaryzacyjnej na podstawie rejestrowanych sygnałów losowych dla przykładowych wyników badań eksperymentalnych. Oszacowano dokładność wyznaczanej wartości.
-
Chapter 8. New composite materials for electrochemical capacitors
PublikacjaW pracy zaprezentowano materiały hybrydowe składające się z polimeru przewodzącego elektronowo połączonego z nieorganiczną siecią typu redoks. Te materiały to poli(3,4-etylenodioksytiofen) modyfikowany heksacyjanożelazianem (II/III) żelaza (pEDOT/Fehcf), kobaltu (pEDOT/Cohcf) i niklu (pEDOT/Nihcf).Materiały elektrodowe scharakteryzowano metodami elektrochemicznymi w elektrolitach niewodnych. Otrzymane materiały hybrydowe cechują...
-
Application of higher order spectra in the electrochemical noise analysis
Publikacja -
Application of non-stationary techniques in the analysis of electrochemical noise.
PublikacjaKlasyczne podejście do analizy szumu elektrochemicznego oparte jest na wstępnym założeniu jego stacjonarności. Pomimo użyteczności, tego typu analiza często prowadzi do mylących wniosków, wynikających z niestacjonarności rejestrów szumowych. W pracy przedstawione zostały możliwości krótkoczasowej transformacji Fouriera, umożliwiającej uzyskanie zależnych od czasu widm mocy sygnału. Osiągane jest to dzięki wykorzystywaniu ruchomego,...
-
Electrochemical approach to evaluate the interlayer adhesion of organic coatings
PublikacjaZastosowano elektrochemiczną spektroskopię impedancyjną do wyznaczania międzywarstwowej adhezji w powłokach organicznych. Zbadano różne zestawy powłok do ochrony samochodów. Zastosowano dwie elektrody wykonane z prądoprzewodzącego tuszu umieszczone pomiędzy warstwami powłokowymi. Stwierdzono, że utrata adhezji międzywarstwowej następuje podobnie jak zmiany energii aktywacji przewodnictwa jonowego w obszarze międzywarstwowym. Uzyskane...
-
Application of higher order statistics in the analysis of electrochemical processes
PublikacjaZjawiska nieliniowe są często spotykane w elektrochemicznych pomiarach korozyjnych. Z drugiej strony linearyzacja zagadnień elektrochemicznych jest uznaną i powszechną praktyką. W niniejszej pracy przedstawiono możliwość poszerzenia interpretacji badanych procesów elektrodowych o techniki oparte na analizie widmowej rzędu wyższego od 2. Autorzy skupili się na analizie szumu elektrochemicznego generowanego podczas polaryzacji katodowej,...
-
TASTE QUALITIES ESTIMATION BY TASTE SENSE AND ELECTROCHEMICAL SENSORS
PublikacjaThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiom etric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Protonic Ceramic Fuel Cells as novel electrochemical devices
PublikacjaProton ceramic conductors are novel materials which are interesting from the application point of view. For example, Protonic Ceramic Fuel Cells (PCFCs) is a type of a solid oxide fuel cell, which uses proton ceramic conductors as an electrolyte. Scientists are looking for the most efficient materials for these devices. In recent years main focus has been put on the search for new proton and mixed proton-electron conductors which...
-
Cavitacion erosion, influence of electrochemical corrosion on cavitation - a review
PublikacjaZjawisko kawitacji polega na narastaniu, a następnie zapadaniu się i implozji pęcherzy wypełnionych gazem lub parami. Zachodzi ono niemalże we wszystkich układach hydrodynamicznych np. w pompach, zaworach, na śrubach okrętowych, turbinach, hydropłatach itp. na skutek lokalnej, gwałtownej zmiany ciśnienia. W większości przypadków jest to zjawisko niepożądane, ponieważ siły generowane podczas implozji pęcherzy kawitacyjnych są tak...
-
Methods of electrochemical noise analysis for investigation of corrosion processes
PublikacjaKorozja elektrochemiczna może być oceniana za pomocą przpływu ładunków między korodującym metalem a elektrolitem. Zwykle, przpływ ładunku obserwuje się w układzie trzech elektrod jako fluktuacje prądu i napięcia (szumy elektrochemiczne). Na podstawie analizy szumów elektrochemicznych można wykrywać różne rodzaje korozji. Korozja jednorodna jest oceniana za pomocą wartości rezystancji polaryzacyjnej występującej między metalem a...
-
Nonlinear impedance of vanadate glasses containing BaTiO3
Dane BadawczeThe nonlinear impedance of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...