Filtry
wszystkich: 1075
-
Katalog
- Publikacje 824 wyników po odfiltrowaniu
- Osoby 21 wyników po odfiltrowaniu
- Wynalazki 8 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Aparatura Badawcza 3 wyników po odfiltrowaniu
- Kursy Online 7 wyników po odfiltrowaniu
- Dane Badawcze 209 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: analizatory impedancji
-
The influence of dynamic load changes on temporary impedance in hydrogen fuel cells, selection and validation of the electrical equivalent circuit
PublikacjaTo achieve optimal performance of a fuel cell, a reliable monitoring and diagnostic method is required. The currently utilized methods give limited information or they are impossible to use under dynamic working conditions. To obtain comprehensive information about the fuel cell operation we utilized novel dynamic electrochemical impedance spectroscopy. Impedance measurements in dynamic mode were performed on a hydrogen fuel cell,...
-
Efficient Gradient-Based Algorithm with Numerical Derivatives for Expedited Optimization of Multi-Parameter Miniaturized Impedance Matching Transformers
PublikacjaFull-wave electromagnetic (EM) simulation tools have become ubiquitous in the design of microwave components. In some cases, e.g., miniaturized microstrip components, EM analysis is mandatory due to considera¬ble cross-coupling effects that cannot be accounted for otherwise (e.g., by means of equivalent circuits). These effects are particularly pronounced in the structures in¬volving slow-wave compact cells and their numerical...
-
Detection of the Plant Pathogen Pseudomonas Syringae pv. Lachrymans on Antibody-Modified Gold Electrodes by Electrochemical Impedance Spectroscopy
PublikacjaThe present work describes an impedimetric immunosensor for Pseudomonas syringae pv. lachrymans (Psl) detection. This pathogen infects many crop species causing considerable yield losses, thus fast and cheap detection method is in high demand. In the assay, the gold disc electrode was modified with 4-aminothiophenol (4-ATP), glutaraldehyde (GA), and anti-Psl antibodies, and free-sites were blocked with bovine serum albumin (BSA)....
-
A Probe into the Corrosion Behavior of a WE43B Magnesium Alloy in a Simulated Body Fluid using Dynamic Electrochemical Impedance Spectroscopy
PublikacjaWE43B is one of the newest Mg alloys with practical application in biomedical implant technology. This work attempts to scrutinize the corrosion characteristics of WE43B alloy in a simulated body fluid (SBF) at a typical body temperature. The dynamic-electrochemical impedance spectroscopy with the capacity to track changes on surfaces in a dynamic corrosive system is used in combination with other classical techniques namely, linear...
-
Avaliação das propriedades de impulso e freqüência em sistemas de aterramento
PublikacjaBezpieczne uziemienia projektowane dla celów ochrony odgromowej powinny odprowadzać prądy wyładowań atmosferycznych przy możliwie niewielkim spadku napięcia. Dla oceny ich skuteczności należy brać pod uwagę nie tylko ich rezystancję, lecz przede wszystkim impedancję. W pracy porównano wyniki symulacji komputerowych i pomiarów na obiektach rzeczywistych impedancji uziemień mierzonych przy wymuszeniach udarowych oraz wysokoczęstotliwościowych.
-
Nowy typ analizatora do pomiarów górnej granicy wybuchowości mieszaniny wo-doru i powietrza.**2003, 90 s. 27 rys. 14 tab. bibliogr. 100 poz. maszyn. Rozprawa doktorska /22.01.2003/ Wydz. Chem. PG Promotor: prof. dr hab. inż. J. Namieśnik.
Publikacja.
-
The loop impedance measurement
Dane BadawczeThe loop impedance measurement
-
Study on surface termination of boron-doped diamond electrodes under anodic polarization in H2SO4 by means of dynamic impedance technique
PublikacjaAnodic oxidation is a popular way to modify termination bonds at boron doped diamond electrodes altering their electrochemical and physicochemical properties. Our studies, performed with dynamic electrochemical impedance spectroscopy technique, supported with X-ray photoelectron spectroscopy and ellipsometry analysis prove its utility in continuous on-line monitoring of impedance changes on the electrode surface under polarization...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
The impact of air humidity on the operation of proton exchange membrane fuel cells determined using dynamic electrochemical impedance spectroscopy
PublikacjaThis paper describes the changes in the fuel cell impedance across a range of current loads and humidity changes. The changes of each equivalent circuit parameters representing specific processes occurring in fuel cells, as a function of humidity and current changes, were determined. Within the combined scope of current and humidity, the optimal working conditions of the cells were determined, corresponding to the lowest impedance...
-
Parametry uziemień przy przebiegach udarowych i wysokoczęstotliwościowych
PublikacjaW artykule skupiono się na porównaniu dwóch metod badania impedancji uziemienia odgromowego: udarowej z wysoką częstotliwościową. Zestawiono wyniki pomiarów istniejących uziemień z wynikami komputerowych obliczeń symulacyjnych przeprowadzonych w środowisku programu PSIM. Uzyskane wyniki wskazują na poprawność przyjętego toku modelowania, a uzyskane w ten sposób dane mogą być przydatne w fazie projektowania do szacowania...
-
Analizator PCR
Aparatura Badawcza -
Michał Ziółko dr inż.
Osoby -
An integral-differential method for impedance determination of the hydrogen oxidation process in the presence of carbon monoxide in the proton exchange membrane fuel cell
PublikacjaThe impedance of a proton exchange membrane fuel cell powered by hydrogen contaminated with carbon monoxide, ranging from 150 to 300 ppb, is measured and discussed. The tested range of CO concentration complied with the fuel standard specified in the ISO standards. Studies of influence of CO contamination on operation of PEMFC are crucial for further development and commercialization of fuel cells for automotive applications. Based...
-
Dynamic electrochemical impedance spectroscopy and polarization studies to evaluate the inhibition effect of benzotriazole on copper-manganese-aluminium alloy in artificial seawater
PublikacjaPrzeprowadzono badania wpływu benzotriazolu (BTA) na korozję nowego typ mosiądzu (CMA) w środowisku syntetycznej wody morskiej przy użyciu dynamicznej elektrochemicznej spektroskopii impedancyjnej (DEIS), techniki polaryzacji rezystancyjnej i ekstrapolacji krzywych Tafela. Wyniki pomiarowe otrzymane przy użyciu tych metod wskazują spadek szybkości korozji wraz ze wzrostem stężenia BTA. Wskazuje to na inhibicyjne własności BTA w...
-
Evaluation of citric acid corrosion inhibition efficiency and passivation kinetics for aluminium alloys in alkaline media by means of dynamic impedance monitoring
PublikacjaA novel approach is proposed for constructing the adsorption isotherm in corrosion studies, based on a well-known interaction between citric acid and aluminium in alkaline electrolytes. Our approach utilizes the instantaneous impedance measurements via Dynamic Electrochemical Impedance Spectroscopy in galvanostatic mode (g-DEIS). Unlike other common tools, g-DEIS delivers exact information about the concentration required for full...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublikacjaIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
Bartosz Czaplewski dr inż.
Osoby -
Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
PublikacjaOpisano konstrukcję oraz badania laboratoryjne modelu nowego automatycznego analizatora śladowych ilości lotnych związków chlorowco-organicznych w wodzie do celów przemysłowych (o wysokiej czystości). Praca analizatora oparta jest na: - przeciwprądowym ciągłym wypłukiwaniu analitów ze strumienia próbki, - okresowym zatrzymywaniu uwolnionych analitów na złożu sorbenta, - desorpcji termicznej, - oznaczaniu sumy związków chlorowco-organicznych...
-
Silicon microcantilever with impedance sensor
Dane BadawczeThe issue of microelectromechanical systems (MEMS) [1] has been enjoying popularity and interest since the 90s of the 20th century. Microcells are one of the simplest devices of this type, but they can be widely used in sensors. There are reports on the possibility of using this type of sensors in the context of such important issues as diagnostics...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stainless steel
Publikacja -
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublikacjaIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
Simultaneous impedance and volumetric studies and additionally potentiodynamic polarization measurements of molasses as a carbon steel corrosion inhibitor in 1M hydrochloric acid solution
PublikacjaThe inhibition effect of molasses on the corrosion of low carbon steel in 1M hydrochloric acid solution was investigated by volumetric and electrochemical measurements. Potentiodynamic polarization and dynamic electrochemical impedance spectroscopy (DEIS) results were obtained and compared with to those, obtained with the hydrogen evolution technique. All results indicate that molasses functioned as a good inhibitor in 1M hydrochloric...
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublikacjaThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Atomic force microscopy based approach to local impedance measurements of grain interiors and grain boundaries of sensitized AISI 304 stanless steel
PublikacjaPraca prezentuje wyniki badań uzyskane z pomiarów techniką lokalnej spektroskopii impedancyjnej (LIS) wykonanych w trybie kontaktowym mikroskopii sił atomowych (AFM), które zostały przeprowadzone w lokalnych obszarach powierzchni ziarna austenitu i na granicy ziarna austenitu wysokostopowej stali austenitycznej AISI 304 poddanej procesowi uczulania oraz na próbkach odniesienia nie poddanych obróbce cieplnej.Badania LIS-AFM były...
-
Biomolecular influenza virus detection based on the electrochemical impedance spectroscopy using the nanocrystalline boron-doped diamond electrodes with covalently bound antibodies
PublikacjaNew rapid pathogen detection methods with improved cost-effectiveness and efficiency are currently in the focus of the scientists from all over the world. Based on the experiences from the rapid spread of the influenza virus pandemic in 2009 it is clear that the development of the system for early diagnosis of this infection is essential. The crucial stage of the treatment is the detection of the viral infection during its initial...
-
Analysis of electromagnetic disturbances in DC network of grid connected building-integrated photovoltaic system
PublikacjaThis paper focuses on conducted electromagnetic interference (EMI) emissions and propagation in the DC network of grid connected building integrated photovoltaic (PV) system. The investigated PV system, consists of ten solar panels, cabling and the grid-connected one phase inverter. The EMI simulation model of the real PV system has been developed with the aid of impedance analyzer measurements of solar panels and the DC network...
-
Marek Wołoszyk dr inż.
Osoby -
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe nonlinear electrcial properties of 50(Bi2VO5.5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 30Bi2VO5.5-70SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 30Bi2VO5.5-70SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of strontium–borate glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of strontium–borate glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 50(Bi2VO5.5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nonlinear impedance of 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrcial properties of 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Simultaneous measurements of ECG, body Impedance and temperature
Dane BadawczeThe data are complementary part of the experiment designed to demonstrate how to use the network protocols to transmit medical data. The dataset contains biomedical signals of ECG, Impedanc and temperature acquired simultaneously. The data allow students to become familiar with data acquisition methods (simulate data transmission by medical device over...
-
Potential and strain rate impact on the electrochemical properties of 304L stainless steel under tensile stresses.
PublikacjaPraca skupia się na badaniach aspektu elektrochemicznego i mechanicznego pękania warstwy pasywnej obecnej na stali 304L. Przedstawione zostały wyniki chwilowych zmian impedancji oraz zmiany parametrów elektrochemicznych warstwy pasywnej podczas testów rozciągania przy różnych poziomach polaryzacji anodowej oraz szybkości rozciągania. Na ich podstawie można stwierdzić, że zarówno czynnik elektrochemiczny, jak i mechaniczny wpływają...
-
Grzegorz Lentka dr hab. inż.
OsobyGrzegorz Lentka uzyskał tytuł magistra inżyniera w roku 1996 na Wydziale Elektroniki, Telekomunikacji i Informatyki Politechniki Gdańskiej w zakresie systemów pomiarowych. Stopień doktora nauk technicznych uzyskał w roku 2003, a doktora habilitowanego w 2014. Obecnie zatrudniony jest w Katedrze Metrologii i Optoelektroniki na stanowisku profesora PG. W ramach prowadzonej dydaktyki zajmuje się zagadnieniami związanymi z interfejsami...
-
Impedance spectroscopy as a diagnostic tool of degradation of Solid Oxide Fuel Cells = Spektroskopia impedancyjna jako narzędzie diagnostyczne degradacji tlenkowych ogniw paliwowych
PublikacjaTlenkowe ogniwa paliwowe SOFC sa obecnie bliskie komercjalizacji. Wiedza na temat mechanizmów degradacji ogniw paliwowych jest niezbędna do dalszej poprawy ich działania. Spektroskopia impedancyjna jest skutecznym narzędziem diagnostycznym. Pozwala ona na wskazanie który element ogniwa SOFC ulega pogorszeniu oraz pozwala poznać dokładniej naturę procesu degradacji. W tej pracy degradacja ogniwa SOFC została zbadana przy użyciu...
-
Metody pomiarowe do kontroli składu i czystości czynników oddechowych. Measuring methods for assessment of composition and purity of breathing mixtures
PublikacjaW pracy przedstawiono główne źródła zanieczyszczeń nurkowych mieszanin oddechowych oraz ogólne zasady kontroli ich składu i czystości. Ponadto omówiono i scharakteryzowano metody i analizatory stosowane do oznaczania poszczególnych rodzajów zanieczyszczeń występujących w czynnikach oddechowych.
-
Sposób ograniczenia wpływu odkształcenia napięcia sieci na dokładność pomiaru impedancji uziemienia metodą techniczną
WynalazkiWynalazek rozwiązuje zagadnienie wyznaczania impedancji uziemienia metodą techniczną w obecności odkształcenia napięcia zasilającego układ pomiarowy. Do ograniczenia wartości prądu pomiarowego stosuje się impedancyjne obciążenie pomiarowe o charakterze indukcyjnym włączone szeregowo z impedancja uziemienia badanego. Wyznacza się zarówno wartość skuteczną tego prądu, jak i wartość skuteczną wywołanego przezeń spadku...
-
Nonlinear impedance of as-quenched Bi2VO5.5 glass-ceramic was measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe nonlinear electrical properties of as-quenched Bi2VO5.5 glass-ceramic was measured by impedance spectroscopy method.
-
Linear impedance of as-quenched 40Bi2VO5.5-60SrB4O7 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrcial properties of 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 10Na2O–60P2O5–30CaO glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 10Na2O–60P2O5–30CaO glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of as-quenched 40Bi2VO5.5-60SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe nonlinear electrical properties of as-quenched 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 40Na2O-20CaO-40P2O5 glass measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of 40Na2O-20CaO-40P2O5 glass was measured by impedance spectroscopy method.
-
Electrochemical cell impedance spectra at Eoc
Dane BadawczeThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Linear impedance of 35P2O5-30Fe2O3-35Nb2O5
Dane BadawczeThe electrical properties of phosphate-iron glasses containing niobium were investigated. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents ((NH4)2HPO4 (≥99.9%, POCH), Fe2O3 (≥99.9%, POCH), Nb2O5 (≥99.9%, PLUKA AG) and TiO2 (≥99.9%, anatase...