Filters
total: 641
filtered: 560
Search results for: ALLOY
-
Formation of High Corrosion Resistant Nanotubular Layers on TitaniumAlloy Ti13Nb13Zr
PublicationThis paper presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr performed at different conditions. The oxide layers have been formed by electrochemical method in 2M H3PO4 + 0.3% HF solution for 30 min. and 1 h at 20 V constantvoltage. The corrosion tests have been made by potentiodynamic method in Ringer`s solution at pH ranged between 3 and 7. It has been shown that the nano-oxide films,...
-
Formation of High Corrosion Resistant Nanotubular Layers on TitaniumAlloy Ti13Nb13Zr
PublicationThis paper presents results of oxidation tests and corrosion investigations of titanium alloy Ti13Nb13Zr performed at different conditions. The oxide layers have been formed by electrochemical method in 2M H3PO4 + 0.3% HF solution for 30 min. and 1 h at 20 V constantvoltage. The corrosion tests have been made by potentiodynamic method in Ringer`s solution at pH ranged between 3 and 7. It has been shown that the nano-oxide films,...
-
Biocompatibility and Bioactivity of Load-Bearing Metallic Implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
Biocompatibility and bioactivity of bearing loaded metallic implants
PublicationPresentation of developed titanium alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behavior for bearing loaded implants, e.g. hip joint and knee joint endoproshtesis.
-
Wpływ zawartości grafitu na właściwości mechaniczne warstw hybrydowych Ni-P/Si3N4/grafit osadzonych na stopie AW-7075 metodą redukcji chemicznej.
PublicationPrzedstawiono wpływ obecności grafitu jako fazy dyspersyjnej na właściwości mechaniczne warstw hybrydowych Ni-P/Si3N4/grafit, które osadzono metodą redukcji chemicznej na stopie glinu AW-7075. Wykonano badania morfologii powierzchni warstw metodą mikroskopii świetlnej i skaningowej. Dalszą część pracy stanowiły badania mechaniczne, czyli pomiary mikrotwardości warstw oraz ich adhezji do aluminiowego podłoża, a także analizy wpływu...
-
Ocena odporności na zużycie ścierne stopów Ti na elementy pary trącej endoprotez stawu kolanowego
PublicationNajczęściej stosowanym biomateriałem tytanowym na elementy endoprotez stawu kolanowego jest stop Ti6Al4V. Z uwagi na zawartość wanadu, zaliczanego do pierwiastków o dużej toksyczności podejmowane są działania w kierunku zastąpienia wskazanego stopu - stopami bezwanadowymi. Jednym z najbardziej obiecujących jest stop Ti13Nb13Zr zawierający w swoim składzie jedynie pierwiastki witalne, niewywołujące stanów zapalnych i odczynów...
-
Effect of microstructure on mechanical properties of BA1055 bronze castings
PublicationThe article presents research results performed on aluminum bronze CuAl10Fe5Ni5 (BA1032) castings used for marine propellers. Metallographic studies were made on light microscope and a scanning electron microscope to assess quantitatively and qualitatively the alloy microstructure. It has been shown that the shape, size and distribution of the iron-rich phase precipitates in bronze microstructure significantly affect its mechanical...
-
The effect of preliminary creep-strain on material behavior under LCF tension/compression and pure torsion regimes
PublicationThis paper presents the results of experimental tests of monotonic tension and torsion, creep-rupture and preliminary creep at 200C and 300C, as well as low-cycle fatigue of 2024 T3511 aluminum alloy. The fatigue process was conducted at room temperature for uniaxial tension/compression and torsion. The as-received material and pre-deformed material were also investigated during creep at elevated temperature. Basic monotonic,...
-
EXPERIMENTAL EVALUATION OF DLC/STEEL SLIDING CONTACTS’ OPERATIONAL ENVELOPE
PublicationIn an industrial project concerning sliding bearings, a sliding pair was selected of high alloy steel vs. industrial grade DLC coated high alloy steel as a basis for an innovative design of high performance sliding bearings lubricated with a synthetic oil for use in geared transmission units. The development process required credible data on the ultimate resistance of the sliding pair to very high contact stress. An experimental...
-
Selection of Electrode Material for Inconel 617/P92 Steel SMAW Dissimilar Welds
PublicationThe present work aimed to investigate the microstructure and mechanical properties of the dissimilar shielded metal arc welded (SMAW) joint of Alloy 617 and P92 steel for advanced ultrasupercritical boilers. The SMAW joint was produced using three different types of electrodes, namely, ENiCrFe-3, ENiCrMo-3, and ENiCrCoMo-1. During microstructural observation of the welded joints, no possible cracking was detected in the weldments....
-
Titania Nanotubes/Hydroxyapatite Nanocomposites Produced with the Use of the Atomic Layer Deposition Technique: Estimation of Bioactivity and Nanomechanical Properties
PublicationTitanium dioxide nanotubes/hydroxyapatite nanocomposites were produced on a titanium alloy (Ti6Al4V/TNT/HA) and studied as a biocompatible coating for an implant surface modification. As a novel approach for this type of nanocomposite fabrication, the atomic layer deposition (ALD) method with an extremely low number of cycles was used to enrich titania nanotubes (TNT) with a very thin hydroxyapatite coating. X-ray diffraction (XRD)...
-
Mechanical Behavior of Bi-Layer and Dispersion Coatings Composed of Several Nanostructures on Ti Substrate
PublicationThree coatings suitable for biomedical applications, including the dispersion coating composed of multi-wall carbon nanotubes (MWCNTs), MWCNTs/TiO2 bi-layer coating, and MWCNTs-Cu dispersion coating, were fabricated by electrophoretic deposition (EPD) on Ti Grade II substrate. Optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, and nanoindentation were applied to study topography, chemical, and...
-
Report no: WOiO /II/46/2015 - Construction node verification test, estimation of breaking load (shear force) and destruction form
PublicationA new generation of tanks for LNG transportation has been designed. Mass reduction forced our customer to use three different materials: austenitic steel, aluminium alloy and LNG compressed wood between them. The expertise concerns structural node between tank foundation and suspension. Expertise contains: description of object of test, test principals, results and conclusions
-
Biocompatibility and bioactivity of load-bearing metallic implants
PublicationThe main objective of here presented research is to develop the titanium (Ti) alloy base composite materials possessing better biocompatibility, longer lifetime and bioactivity behaviour for load-bearing implants, e.g. hip joint and knee joint endoprosthesis. The development of such materials is performed through: modeling the material behaviour in biological environment in long time and developing of new procedures for such evaluation;...
-
LCF behavior of 2024AA under uni- and biaxial loading taking into account creep pre-deformation
PublicationThis study presents the results of experimental low-cycle fatigue (LCF) tests of aluminum 2024 alloy T3511 temper in uni- and biaxial loading states. Tests were carried out on both the as-received material (hardened extruded rods) and material with different pre-deformation histories. These deformations were carried out in the creep process at 200 °C and 300 °C for two different levels of at each temperature. The pre-deformed material’s...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Materials Design for the Titanium Scaffold Based Implant
PublicationThe main objective of here presented research is a design the scaffold/porous titanium(Ti) alloy based composite material demonstrating better biocompatibility, longer lifetime andbioactivity behaviour for load-bearing implants. The development of such material is proposed bymaking a number of consecutive tasks. Modelling the mechanical, biomechanical and biologicalbehavior of porous titanium structure and an elaboration of results...
-
Effects of the preheating laser treatment on microstructure and corrosion resistance of Ti6Al4V bioalloy
PublicationThe laser remelting of the Ti6Al4V alloy was made on specimens pre-heated at elevated temperatures. The laser treatment effected in change of microstructures of surface layers and an appearance of blisters and numerous cracks. The corrosion tests demonstrated the decrease in corrosion resistance for each preheating temperature. The observed effects were attributed to negative influence of excessive compressive stresses with no...
-
Formation of Porous Structure of the Metallic Materials Used on Bone Implants
PublicationResearch on improvement of structure and fabrication methods of the bone implants are carried out for many years. Research are aimed to shape the structures, that will have a Young's modulus value similar to the value of the human bones Young's modulus. Depending on theporosity, Young's moduli can even be tailored to match the modulus of bone closer than solid metals can, thus reducing the problems associated with stress shielding...
-
Hydrogen Embrittlement and Oxide Layer E ect in the Cathodically Charged Zircaloy-2
PublicationThe present paper is aimed at determining the less investigated effects of hydrogen uptake on the microstructure and the mechanical behavior of the oxidized Zircaloy-2 alloy. The specimens were oxidized and charged with hydrogen. The different oxidation temperatures and cathodic current densities were applied. The scanning electron microscopy, X-ray electron diffraction spectroscopy, hydrogen absorption assessment, tensile, and...
-
Numerical and Analytical Investigation of Aluminium Bracket Strengthening
PublicationThis paper focuses on an analytical and numerical investigation of aluminium brackets used to fasten light-weight curtain walls to building facilities. The authors propose a solution to increase the load capacity of aluminium brackets by means of additional cover plates (straps). This paper also includes a short survey of literature and material properties concerning the EN AW-6060 T6 aluminium alloy. This paper suggests an initiation...
-
Some problems of slide bearing material fatigue evaluation.
PublicationA slide bearing alloy resistance against fatigue failures have been investigated for three different lubricants, different heat loadings and different stress ratio κ values. The research methods and data handling procedures for determination of particular parameter effects on fatigue strength have been described and analysed for experiments that were set and performed in laboratory tester SKMR-2. Main and interaction effects of...
-
Failure analysis of the exhaust valve face in diesel marine engine
PublicationThe exhaust valve from marine diesel engine which was damaged after 2000 hours of service was investigated. In order to prolong the service time the valve face was cladded with cobalt base alloy using laser technique. After failure microstructural and chemical analyses reviled that cladding process was conducted improperly. The chemical composition of the clad layer was far from the designed one and what more completely inhomogeneous....
-
Determination of causes of accelerated local corrosion of austenitic steels in water supply systems
PublicationThis paper concerns an inspection of a water supply system, made of AISI 304 steel, which showed signs of local corrosion at the weld. Such corrosion caused material perforation after very short periods of operation. It was revealed that steel was sensitised during the welding process. It was also proven that chromium micro-segregation occurred in the alloy leading to galvanic cell formation which initialised the process of pitting...
-
Glass-ceramic sealants and steel interconnects: accelerated interfacial stability and reactivity tests at high temperature
PublicationHigh-temperature reactions between glass-ceramic sealants and Fe-Cr alloy interconnects may lead to the formation of undesirable phases, and consequently degradation of solid oxide fuel/electrolyser devices. In this work, three different glass-ceramic sealants (Na-containing, Ba-containing, Sr-containing compositions) and Fe22Cr stainless steel powders (raw and pre-oxidised) are considered in order to test their chemical reactivity...
-
Vascular stents - materials and manufacturing technologies
PublicationThe objective of this article is to present materials and technology for the manufacture of vascular stents with appropriate design requirements. The use of the right material is very important in implantology. A biomaterial introduced into the circulatory system must be biocompatible and hemocompatible. At the same time, it should not initiate toxic, mutagenic, or immunological reactions. Currently, 316L stainless steel (316L...
-
Intergranular Corrosion Detection Using Electromagnetic Transducers for Ultrasonic Testing
PublicationThe aim of this paper is to create a research methodology that allows a quick analysis of the structural state of high alloy austenitic steels using non-destructive ultrasonic tests, in contrast to destructive standard methods. Electromagnetic acoustic transducers (EMAT) are used to generate and receive the ultrasonic wave and detect the microstructural changes caused by sample sensitization in elevated temperature, even after...
-
Cavitation Erosion of Nodular Cast Iron - Microstructural Effects
PublicationThe paper deals with susceptibility of nodular cast iron with ferritic-pearlitic matrix on cavitation erosion. Cavitation tests were carried out with the use of a cavitation erosion vibratory apparatus employing a vibration exciter operated at frequency of 20 kHz. The study allowed to determine the sequence of subsequent stages in which microstructure of cast iron in superficial regions is subject to degradation. The first features...
-
Właściwości złączy różnoimiennych stopu niklu Incoloy 800H ze stalą odporną na korozję 316L
PublicationW artykule przedstawiono problemy związane z wykonywaniem połączeń różnoimiennych typu Incoloy 800HT – austenityczna stal odporna na korozję 316L. Wykonano badania nieniszczące oraz niszczące, których wyniki pozwoliły na weryfikacje jakości wykonanych złączy próbnych. Nie stwierdzono występowania niezgodności spawalniczych oraz uzyskano wysokie właściwości wytrzymałościowe złączy. Badania metalograficzne ujawniły poprawne struktury...
-
Powłoki na osnowie pierwiastkowego węgla przeznaczone na implanty tytanowe
PublicationRozprawa miała na celu modyfikację podłoża z tytanu II oraz stopu Ti13Nb13Zr poprzez osadzenie elektroforetyczne (EPD) powłok na bazie wielościennych nanorurek węglowych (MWCNTs) z dodatkami wielkości nanometrycznej, przeznaczonych na pokrycia trzpieni endoprotez stawu biodrowego. Przygotowano trzy rodzaje powłok MWCNTs: z dodatkiem nanomiedzi (MWCNTs/Cu), nanosrebra (MWCNTs/Ag) oraz tlenku tytanu (MWCNTs/TiO2), osadzone w procesie...
-
Titania Nanofiber Scaffolds with Enhanced Biointegration Activity—Preliminary In Vitro Studies
PublicationThe increasing need for novel bone replacement materials has been driving numerous studies on modifying their surface to stimulate osteogenic cells expansion and to accelerate bone tissue regeneration. The goal of the presented study was to optimize the production of titania-based bioactive materials with high porosity and defined nanostructure, which supports the cell viability and growth. We have chosen to our experiments TiO2...
-
Thermal cooling process by nanofluid flowing near stagnating point of expanding surface under induced magnetism force: A computational case study
PublicationThis paper is dedicated to the exam of entropy age and research of the effect of mixing nanosolid additives over an extending sheet. In this review, Newtonian nanofluid version turned into researched at the actuated appealing field, heat radiation and variable heat conductivity results. With becoming modifications, the proven PDEs are moved into popular differential situations and paintings mathematically making use of a specific...
-
TiO 2 Co x O y composite nanotube arrays via one step electrochemical anodization for visible light–induced photocatalytic reaction
PublicationTiO2CoxOy (x = 1, y = 1 or x = 3, y = 4) composite photocatalysts have been synthesized via one step anodic anodization of TiCo alloys. The effects of the cobalt content in the alloy (5, 10 and 15 wt%), water content (2, 5 and 10%) in the electrolyte solution, and applied voltage (30, 40 and 50 V) during the anodization process on the morphology and surface properties. Additionally, the dependence of cobalt content in the nanotubes...
-
COLD CRACKING OF S460N STEEL WELDED IN WATER ENVIRONMENT
PublicationThis paper shows results of weldability testing of fine-grained high -strength low- alloy S460N steel welded in water environment by covered electrodes. The tests were carried out by using the CTS test specimens with fillet welds. Four specimens were welded under water and one specimen in air. Welded joints were subjected to non-destructive visual and penetration tests. The accepted joints were then subjected to macroscopic and...
-
3D Printing of Metallic Implants
PublicationThe fabrication of various elements, solid and open porous structures of stainless steel and Ti alloy is described. The process was started with the design of 3D models in CAD/CAM system. The 3D models were transformed into *.stl files and then the manufacturing process of the real structures by means of the selective laser melting with the SLM Realizer 100 3D printer was made. The paper shows the porous specimens made for possible...
-
Application of acoustic emission for detection of fatigue microdemage in main and crank bearings for diesel engines
PublicationThe article presents reasons for applying the acoustic emission (AE) to detect fatigue microdamage in main bearings and crank bearings of ship main engines. Problem of determination of the fatigue life for slide bearing bushes was characterized in general. There were demonstrated properties of the objects of research, which were bushings made of the MB58 alloy, as well as an overall description of the research. It was shown that...
-
Synthesis and Characterization of Monometallic (Ag, Cu) and Bimetallic Ag-Cu Particles for Antibacterial and Antifungal Applications
PublicationIn this paper, the experimental studies are concerned with the effect of the synthesis parameters on the formation of monometallic Ag and Cu nanoparticles (NPs). We consider the synthesis strategies verification for the bimetallic core-shell and alloy particles preparation. It was successfully obtained by chemical reduction method. The obtained colloidal solution is characterized by the transmission electron microscopy (TEM) with...
-
Temper bead welding of S460N steel in wet welding conditions
PublicationWet welding is the most common method of welding in water environment. It is most often used for repairing of underwater parts of offshore structures. However, the water as a welding environment causes an increase of susceptibility of steels to cold cracking. For underwater constructions high strength low alloy (HSLA) steel are widely used. In wet welding condition a HSLA steel is characterized by high susceptibility to cold cracking....
-
Badania spawalności stali S460N w środowisku wodnym z wykorzystaniem próby Tekken
PublicationSpawanie w środowisku wodnym niesie ze sobą wiele problemów, wśród których najważniejszym jest skłonność stali do powstawania pęknięć zimnych. O ile w przypadku spawania na powietrzu istnieje wiele metod zapobiegania tym pęknięciom, o tyle pod wodą zastosowanie tych metod jest ograniczone. Z tego powodu konieczne jest określenie skłonności danego materiału do pękania zimnego. W pracy oceniono spawalność drobnoziarnistej...
-
Synthesis and physical properties of Sm2PdGe3 in a context of RE2PdGe3 family
PublicationIn this study, we present the crystallographic and magnetic characterization of a new intermetallic compound Sm2PdGe3, which was synthetized by a two stage method employing an eutectic alloy. The investigations carried out exhibited, that Sm2PdGe3 crystallize in AlB2-type structure with lattice parameters a = 4.2189(1) Å and c = 4.1031(2) Å. This compound can be classified as a cluster-glass with a spin freezing temperature Tf...
-
THE DETERMINATION OF ABRASION RESISTANCE OF SELECTED BIOMATERIALS FOR THE FRICTION PAIRS IN THE HIP JOINT ENDOPROSTHESIS
PublicationThe key requirement for the modern endoprosthesis is high durability of the friction components, which results in long and trouble-free operation in the human body. The durability of currently used endoprosthesis is often limited by tribological wear processes of friction components (e.g. between the head and the acetabular component in a hip joint endoprosthesis) [8, 19, 23, 24]. In order to compare the tribological wear, tribological...
-
Corrosion monitoring by harmonic analysis in aqueous environments
PublicationThis paper presents tests concerning the rate of corrosion in non-alloy steel (type S235JR) in an aqueous environment, with an additive of sodium chloride by means of polarization resistance measurements and harmonic analysis. The tests have been carried out for steel samples exposed to the testing environment for six weeks, in order to obtain a constant rate of corrosion in the function of time. The measurements have aimed at...
-
Structure of the interlayer between Au thin film and Si-substrate: Molecular Dynamics simulations
PublicationInteraction between 2, 3, 5 and 7 atomic layers of gold and a (111) silicon surface was investigated with the molecular dynamics simulation method. The simulation of the diffusion interaction between gold and silicon in the temperature range 425-925 K has been carried out. The peculiarities of the concentration changes of the interacting components and the atomic density at the boundary...
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublicationThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...
-
Mrówczan sodu z nowym pakietem inhibitorów korozji jako ekologiczny środek do odladzania infrastruktury lotniczej.
PublicationPrzedstawiono wyniki badań korozji kadmowej powłoki na stali oraz korozji po zanurzeniu stopów metali w mrówczanie sodu z nowym pakietem inhibitorów korozji, zawierającym synergiczną kompozycję poliasparaginianu sodu oraz imidazolu. Ponadto wyznaczono zdolność penetracji lodu przez badany układ. Właściwo- ści opracowanej kompozycji odladzającej porównano z właściwościami środków dostępnych na rynku. Uzyskane wyniki wskazują, że otrzymany...
-
High temperature corrosion of evaporator tubes with thermal sprayed coatings
PublicationDegradation examinations of outer surface of low-emission steam boiler evaporator tubes are presented in the paper. Metallographic evaluation of scale morphology, its micro sites chemical composition analysis and distribution of elements on cross sections have been performed. Water-wall tubes were exposed in steam boiler for up to two years period. Common tubes made of 16Mo3 steel suffered sulphide and molten salts corrosions....
-
Effect of electrode waterproof coating on quality of underwater wet welded joints
PublicationIn this paper, the effects of different hydrophobic coatings on the surface of covered electrodes on the quality of wet welded carbon steel joints were discussed. Commonly available hydrophobic substances used in industrial applications were selected for the research. The aim of using waterproof coatings was to check the possibility to decreasing the susceptibility of highstrength low-alloy S460N steel to cold cracking. During...
-
The effect of elevated temperature on LCF damage growth in 2024AA – Experiment and modeling
PublicationThis paper presents the results of experimental low-cycle fatigue (LCF) tests conducted on EN-AW 2024 alloy in T3511 temper at 100 ◦C, 200 ◦C and 300 ◦C. The material’s basic fatigue characteristics were determined, such as fatigue life curve and cyclic strain curve. Both the hysteresis loop and nature of fracture surfaces obtained in macro- and microscopic observations (scanning electron microscope, SEM) were accounted for. The...
-
Manganese Phosphatizing Coatings: The Effects of Preparation Conditions on Surface Properties
PublicationManganese phosphate coating could be used to protect the surface of steel products. However, it is essential to determine the effects which process parameters, as well as the types of additives used, have on the efficiency of coating deposition. Thus, we present here a process of phosphatization of low-alloy steel (for 15 min at 95 ◦C) in manganese/nickel baths followed by a passivation process with the use of a silicon and zircon...
-
Problems of analytical determination of journal bearing bush fatigue strength estimates
PublicationProblems connected with determination of stress distribution in sliding layer of thinwalled bearing bushes, investigated in bearing fatigue test rigs, have been presented. Using an example of plain bearings tested in the fatigue machine SMOK (built at the Gdask University of Technology) problems with obtaining a convergence of iterative procedure for determining the fatigue strength estimators of bearing alloy surface layer are...