Filters
total: 4549
filtered: 3310
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: OPTICAL STRAIN MEASUREMENT
-
Salicylaldimine-based receptor as a material for iron(III) selective optical sensing
Publicationα,α-Bis(salicylimino)-m-xylene (L) was prepared using both conventional and microwave-assisted procedure. The compound exhibits ability to colorimetric recognition of iron(III) ions in aqueous environment, what is shown by significant color change from yellow to purple. In DMSO : water (9:1 v/v) solvent system receptor creates with iron(III) cations complexes of 2:1 stoichiometry (L:Fe3+) with stability constant (log K) 7.54±0.21....
-
PbGa2GeS6 crystal as a novel nonlinear optical material: Band structure aspects
Publication -
Synthesis, ellipsometry and non-linear optical features of substituted 1,3,5-triphenylpyrazolines
Publication -
Functionalized mesoporous silica thin films as a tunable nonlinear optical material
Publication -
Optical theorem helps understand thresholds of lasing in open semiconductor microcavities
Publication -
Optical Theorem Helps Understand Thresholds of Lasing in Microcavities With Active Regions
Publication -
Modelling of optical components made of liquid crystals and liquid crystalline polymers
PublicationW artykule przedstawiono koncepcję wykorzystania ciekłych kryształów i polimerów ciekłokrystalicznych do budowy dwójłomnych elementów optycznych - płytek opóźniających, pryzmatów Wollastona i Nomarskiego. Przedstawiono wyniki modelowania pryzmatów Nomarskiego wykonanych z polimerów ciekłokrystalicznych i dokonano porównania ich właściwości z właściwościami pryzmatów wykonanych z typowych materiałów dwójłomnych.
-
Investigation of energy deposition and its optical imaging in polymer gel dosimeters
PublicationThis following chapter describes methods for verifying the absorbed dose during radiotherapy. Special attention is paid to the method using polymer-gel dosimeters, the dose reading of which is performed by means of Laser Computed Tomography. The chapter also includes considerations on alternative solutions for dosimetric measurements and various types of radiotherapy and their pros and cons. In addition, both the methods of structural...
-
Pyrrole bearing diazocrowns: Selective chromoionophores for lead(II) optical sensing
PublicationDiazocrowns of 18-, 21- and 23-membered rings with pyrrole residue as a part of macrocycle were for the first time used as chromoionophores in lead(II) selective optodes. Sensing properties of optodes depend on the type of macrocycle, namely its size and the type of linker: oligoether or hydrocarbon chain. The best results were obtained for optode bearing 18-membered crown with oligoether linker showing linear response range of...
-
Optical Spectroscopic Studies of Tetrahydrofuran Fragmentation Induced by Collisions with Dihydrogen Cations
PublicationCollisions of dihydrogen cations with tetrahydrofuran molecules have been studied. Luminescence spectra and the emission functions of the excited products at projectile energies ranging from 8 to 1000 eV have been measured using collision-induced emission spectroscopy. The recorded spectra are dominated by the atomic lines of the hydrogen Balmer series, whose intensities decrease more quickly than derived by the quantum-theoretical...
-
Characterization of PLZT Thin Films for Fast Electro-Optical Sampling Circuits
PublicationW artykule omówiono technologię wytwarzania cienkich warstw wybranych kompozycji ceramik ołowiowo-lantanowo-cyrkonowo-tytanowych, nazywanych ceramikami PLZT. Przedstawiono wyniki badań jakości warstw za pomocą techniki XRD. wyniki pomiaru grubości warstw, ich względnej przenikalności dielektrycznej i współczynnika załamania. Omówiono kierunki dalszych prac.
-
Ultrahigh-resolution detection techniques for biomedical applications of optical coherent tomography.
PublicationOptyczne metody pomiarowe odgrywają w ostatnich latach coraz większą rolę w badaniach i diagnostyce medycznej. Mają one szereg zalet, do których zaliczyć można odporność na promieniowanie elektromagnetyczne, bezinwazyjność, bezpieczeństwo pomiaru oraz wysoką rozdzielczość. Jedną z najważniejszych technik stosowanych w diagnostyce medycznej jest koherentna tomografia optyczna (OCT). Jest to wysokorozdzielcza metoda obrazowania wewnętrznych...
-
Estimation of optical parameters of highly scattering materials by time-of-flight spectroscopy.
PublicationPrzedstawiono metody wyznaczania podstawowych parametrów materiałów silnie rozpraszających światło na podstawie pomierzonego rozkładu czasu przelotu krótkich impulsów laserowych. W algorytmie wykorzystano metodę Monte Carlo i metodę dyfuzji do opisu propagacji światła. Oszacowano dokładność oszacowywania tych parametrów.
-
A Chemical Recognition Element for Lithium Ions Based on Optical Electronic Absorption.
PublicationOtrzymano próbki kserożeli techniką zol-żel. Otrzymane materiały zastosowano do konstrukcji czujników optycznych. Rolę elementu rozpoznającego w uzyskanych próbkach pełnią chromogeniczne etery koronowe zawierające w makro pierścieniu dwie grupy azowe oraz resztę fenolu. W obecności soli metali I grupy układ u okresowego obserwowano zmiany w widmach absorpcyjnych. Dla matrycy zawierającej jako materiał czujnikowy 21-członową...
-
The optical properties and band gap energy of nanocrystalline La0.4Sr0.6TiO3 thin films
PublicationW pracy zbadano wpływ mikrostruktury na właściwości optyczne La0.4Sr0.6TiO3 przygotowanego w postaci cienkiego filmu. Gęsty film o grubości 200nm i wielkości krystalitów 14-30nm został przygotowany na szafirze.
-
High resolution optical and acoustic remote sensing datasets of the Puck Lagoon
PublicationThe very shallow marine basin of Puck Lagoon in the southern Baltic Sea, on the Northern coast of Poland, hosts valuable benthic habitats and cultural heritage sites. These include, among others, protected Zostera marina meadows, one of the Baltic’s major medieval harbours, a ship graveyard, and likely other submerged features that are yet to be discovered. Prior to this project, no comprehensive high-resolution remote sensing...
-
New matrix-free reference material for ethene in the form of optical fibres
PublicationReference materials are indispensable in the qualitycontrol and quality assurance of analytical measurements. Onenovel approach to the generation of standard gaseous mixturesof toxic, reactive, volatile, labile, and malodorous substancesinvolves thermal decomposition or rearrangement, under definedtemperature conditions, of compounds immobilized, bychemical bonding, on the surface of an appropriate carrier torelease specific amounts...
-
Induction Motor Multiscalar Model Based Sensorless Control Using Power Measurement
Publication -
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Measurement invariance of the Belief in a Zero‐Sum Game scale across 36 countries
Publication -
<title>Modeling of noncontact temperature measurement system using multiwavelength pyrometry</title>
Publication -
Evaluation of a 10 nm Particle Number Portable Emissions Measurement System (PEMS)
Publication -
Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays
Publication -
Application of Maximum-Length Sequences to impulse response measurement of hydroacoustic communications systems
PublicationThere is a growing interest in digital transmission of telemetry data on ultrasonic waves. The dependence of signal attenuation on squared frequency, specific to the hy-droacoustic systems, induces problems that do not exist in monochromatic, narrowband radio communications systems. For adapting the transmission parameters to current propagation conditions, a precise knowledge of instantaneous changes of channel performances is...
-
Low Frequency Noise Measurement of Reverse Polarized Silicon Carbide Schottky Diodes
PublicationW artykule przedstawiono wyniki pomiaró szumów cz. wstecznie spolaryzowanych diod Schottky'ego.
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Challenges in oscillometric blood pressure measurement in atrial fibrillation: looking for practical solutions
Publication -
In-service measurement of the small wind turbine test stand for structural health monitoring
PublicationThis paper presents the research activity performed on a Small Wind Turbine (SWT) test stand. Commercially available turbine was modified towards incorporation of the sensors system for condition monitoring. Installed sensors measure angular shaft position, torque applied from the wind loads, vibration accelerations and last but not least rotational speed. All gathered data are then transferred and processed in Test.Lab by means...
-
Measurement of ethylene production as a method for determining the optimum harvest date of ‘Jonagored’ apples
Publication -
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Determination of magnetisation conditions in a Double-Core Barkhausen Noise measurement set-up
PublicationThe magnetic Barkhausen effect is useful forassessing 1D and 2D stress states of ferromagnetic steelobjects. However, its extension to technically importantmaterials, such as duplex anisotropic steels, remains challenging. The determination of magnetisation inside the studied object and the electromagnet for various geometries, materials and magnetisation angles is a key issue.Three-dimensional, dynamic finite element analysis...
-
MEASUREMENT AND ANALYSIS OF A FLOOD WAVE PROPAGATION ON THE KACZA RIVER IN GDYNIA IN NORTHERN POLAND
PublicationKacza river is located in northern Poland in the neighborhood of the Gulf of Gdansk and the Baltic Sea. A Kacza having length of 15 km and catchment area of 53 km2 collects the water into the Gulf mostly from inhabited and forested areas within the administrative boundaries of the city of Gdynia. On the 14th and 15th of July 2016 in northern Poland on the large area of Tri-City agglomeration (Gdynia, Gdansk and Sopot) total daily...
-
Analysis of distance measurement errors in CW FM sonar with MLS code modulation
PublicationAlthough used in the classic silent sonar, the CW FM sounding signal has a major flaw which is its inaccuracy in determining the distance to a target. The authors of the article have developed a concept of silent sonar using frequency modulation signals switched by pseudorandom codes, already discussed in their previous work. This article presents a detailed analysis of errors in CW FM sonar with pseudo-random sequence code modulation...
-
The measurement and calculation of gas temperature inside a switchgear during fault arc period.
PublicationW artykule przedstawiono metodę obliczania temperatury gazu wewnątrz rozdzielnicy szczelnej z izolacją powietrzną podczas zwarć łukowych w oparciu o równanie przewodnictwa cieplnego. Przedstawiono wyniki badań eksperymentalnych temperatury gazów podczas zwarć z łukiem wędrującym. Opisano model do badań, układ probierczy i warunki badań. Wyniki obliczeń porównano z wynikami badań eksperymentalnych.
-
Influence of the analyzing window on electrode impedance measurement by thecontinuous freqency scanning method
PublicationPrzeprowadzono pomiary impedancyjne modelowego układu elektrycznego RC techniką ciągłego skanowania częstotliwościowego. Wyznaczono impedancję modelowego układu dla różnych okien analizujących oraz ich różnych wielkości. Wyznaczone dla różnych okien analizujących wartości R i C porównywano z wartościami rzeczywistymi. Stwierdzono wpływ rodzaju okna analizującego oraz jego długość na dokładność otrzymywanych wyników.
-
Application of polarisation-maintaining side-hole fibres do direct force measurement
PublicationW pracy przedstawiono zastosowanie utrzymujących polaryzację światłowodów typu Side Hole do bezpośredniego pomiaru siły. Dla wybranych struktur tych światłowodów wyznaczono, przy pomocy Metody Elementów Skończonych i metody modów sprzężonych, czułość na siłę działającą prostopadle do osi symetrii światłowodu. Określono zależność tej czułości od poszczególnych wymiarów struktur tych światłowodów. Następnie, biorąc pod...
-
Time domain diagnosis of anticorrosion coatings via shape designed measurement signals.
PublicationW pracy przedstawiono operującą w dziedzinie czasu metodę diagnostyki pokryć przeciwkorozyjnych, na poziomie identyfikacji parametrów obwodu zastępczego. Metoda jest oparta na pobudzeniu obiektu sygnałem niekonwencjonalnym o projektowanym kształcie i pomiarze odpowiedzi obiektu (tzw. obserwabla) po upływie zadanego czasu T. Parametry obwodu zastępczego są obliczane bezpośrednio z obserwabli na podstawie równań wynikających z topologii...
-
Accelerated impedance spectrum measurement via multisine perturbationand digital filter banks
PublicationPrzedstawiono przyspieszoną metodę pomiaru widma impedancyjnego, zorientowaną na pomiary jakości powłok przeciwkorozyjnych, modelowanych liniowymi obwodami zastępczymi. Metoda polega na pobudzeniu układu wielosinusoidalnym sygnałem popudzającym oraz analizie pobudzenia i odpowiedzi obiektu przez bank filtrów cyfrowych. Przedstawiono podstawy teoretyczne metody oraz propozycję metodologii pomiaru. Przeanalizowano wyniki symulacji...
-
Example of practical use of vibration measurement results - study of settlement of the Wisłoujście Tower
PublicationW pracy przedstawiono wyniki identyfikacji parametrów posadowienia wieży Twierdzy Wisłoujście. Badanie oparto na zidentyfikowanych w pomiarach częstotliwościach drgań swobodnych wieży. Przyjęto prosty model dynamiczny obiektu, dobrze opisujący jego zachowanie.
-
Measurement of magnetic signals of vehicles with denoising by matched filtering with FPGA FFT processor
PublicationW artykule przedstawiono realizację systemu do analizy i identyfikacji pojazdów oparty na pomiarze indukcji magnetycznej. Proponowany system może być zastosowany do wykrywania i identyfikacji pojadów zawierających elementy ferromagnetyczne, które zaburzają pole magnetyczne ziemi. Zaburzenie to można zmierzyć przy zastosowaniu trójosiowych magnetometrów transduktorowych, pracującyh w układzie różnicowycm. Zastosowano w systemie...
-
Research on flue gas flow measurement and modelling in the moving grate biomass boiler
PublicationThe aim of this research was to determine the nature of gas flow in a grate boiler model by the method of Particle Image Velocimetry (PIV) and CFD. The paper presents the comparison of the PIV results with numerical simulations made in the environment of ANSYS Fluent. The main goal of the experiment was to describe the phenomena occurring on the grate. Methodology of modelling solid fuel combustion on the moving grate was proposed...
-
Interval estimator for chlorine monitoring in drinking water distribution systems under uncertain system dynamics, inputs and state measurement errors
PublicationThe design of interval observer for estimation of unmeasured state variables for application to drinking water distribution systems is described in this paper. In particular, it considers the design of such observer for estimation of water quality described by free chlorine concentration. An interval observer is derived to produce robust interval bounds on the estimated water quality state variables. The stability and robustness...
-
The Effect of Full-Cell Impregnation of Pine Wood (Pinus sylvestris L.) on Changes in Electrical Resistance and on the Accuracy of Moisture Content Measurement Using Resistance Meters
PublicationThe impact of the full-cell impregnation of pine wood was investigated with respect to changes in electrical resistance and the accuracy of moisture content measurement. This study compared the resistance of impregnated and untreated pine timber harvested from the northern part of Poland (Pomeranian region). The wood was impregnated by the vacuum-pressure method. The preservative (TANALITH E 3475) and coloring (TANATONE 3950) agents...
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublicationThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
The stress and strain distribution in X10CrMoVNb9-1 power engineering steel after long time degradation studied by the ESPI system
Publication -
The analysis of strain response for as-received and exploited 10H2M power engineering steel subjected to low cycle fatigue in plastic regime
Publication -
Detection of specific UL49 sequences of Marek's disease virus CVI988/Rispens strain using loop-mediated isothermal amplification
Publication