Filters
total: 795
filtered: 792
Search results for: MAGNETIC EFFECTS
-
Life tests of a rotary single-stage magnetic-fluid seal for shipbuilding applications
PublicationUse of the magnetic fluid seal technology in water is much more difficult technological problem in comparisonto gas or vacuum environment. Some seals constructed up to time been are designed as hybrid, two stagesealing structures with shields or mechanical seals used as protection measures to the magnetic fluid seal.Anyway, there is always problem with immediate contact between magnetic fluid and the environmentalliquid. In the...
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Spectroscopic and magnetic studies of highly dispersible superparamagnetic silica coated magnetite nanoparticles
PublicationSuperparamagnetic behavior in aqueously well dispersible magnetite core-shell Fe3O4@SiO2 nanoparticles is presented. The magnetic properties of core-shell nanoparticles were measured with use of the DC, AC magnetometry and EPR spectroscopy. Particles were characterized by HR-TEM and Raman spectroscopy, showing a crystalline magnetic core of 11.5 ± 0.12 nm and an amorphous silica shell of 22 ± 1.5 nm in thickness. The DC, AC magnetic...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Non-Linear Interaction of Harmonic Waves in a Quasi-Isentropic Flow of Magnetic Gas
PublicationThe diversity of wave modes in the magnetic gas gives rise to a wide variety of nonlinear phenomenaassociated with these modes. We focus on the planar fast and slow magnetosound waves in the geometryof a flow where the wave vector forms an arbitrary angleθwith the equilibrium straight magnetic field.Nonlinear distortions of a modulated signal in the magnetic gas are considered and compared to thatin unmagnetised gas. The case of...
-
NEW DESIGNS OF CENTRIFUGAL MAGNETIC FLUID SEALS FOR ROTATING SHAFTS IN MARINE TECHNOLOGY
PublicationThe centrifugal magnetic fluid seals have important advantage over the conventional centrifugal seals. They maintain very good sealing capacity at static, medium and high speeds of shaft rotation, with the increased seal lifetime, and minimum torque and static friction. These seals are particularly useful in cases when the angular shaft velocity varies and sometimes decreases to nearly or exactly zero, such as in flywheel applications,...
-
Tuning the photocatalytic performance through magnetization in Co-Zn ferrite nanoparticles
PublicationIn this work, the link between the photocatalytic performance of Co-Zn ferrite nanoparticles and the net magnetic moment is analyzed. CoxZn1-xFe2O4 nanoparticles (0 ≤ x ≤ 1) were synthesized by co-precipitation method and different physicochemical techniques were employed to characterize the samples (X-ray diffraction, Transmission Electron Microscopy (TEM), BET surface area, Diffuse Reflectance Spectroscopy (DRS), Photoluminescence spectroscopy,...
-
Magnetic superhydrophobic melamine sponges for crude oil removal from water
PublicationThis paper proposes the preparation of a new sorbent material based on melamine sponges (MS) with superhydrophobic, superoleophilic, and magnetic properties. This study involved impregnating the surface of commercially available MS with eco-friendly deep eutectic solvents (DES) and Fe3O4 nanoparticles. The DES selection was based on the screening of 105 eutectic mixtures using COSMO-RS modeling. Other parameters affecting the efficiency...
-
Maximum transportation growth in energy and solute particles in Prandtl martial across a vertical 3D-heated surface: Simulations achieved using by finite element approach
PublicationThe goal of this study is to determine the maximum energy and solute particles' transportation growth in a 3D-heated region of Prandtl martial through a dynamic magnetic field. The effects of this field on the properties of solvent molecules and heat conduction are studied. A correctly stated functional method and a finite element approach are comparable to a certain type of differential equations. In order demonstrate the effects...
-
Design and Application of Magnetic Photocatalysts for Water Treatment. The Effect of Particle Charge on Surface
PublicationCore-interlayer-shell Fe3O4/SiO2/TiO2, CoFe2O4/SiO2/TiO2 and BaFe12O19/SiO2/TiO2 magnetic photocatalysts were obtained. A water-in-oil microemulsion system with suitable surfactants was used for functionalization of the magnetic core with silica interlayer and TiO2-based photocatalyst. Uncoated and coated particles were characterized by electrophoretic meaurements, X-ray diffractometry (XRD), scanning electron microscopy (SEM),...
-
Magnetic structure and properties of theS=5∕2triangular antiferromagnetα−NaFeO2
Publication -
A correct description of the interaction between a magnetic moment and its image
Publication -
Superstable magnetic nanoreactors with high efficiency for Suzuki-coupling reactions
Publication -
Filling of Carbon Nanotubes: Containers for Magnetic Probes and Drug Delivery
Publication -
Rich magnetic phase diagram in the Kagome-staircase compound Mn3V2O8
PublicationNa podstawie pomiarów podatności magnetycznej i ciepła właściwego monokryształu Mn3V2O8 skonstruowano diagram fazowy. Właściwości magnetyczne związku są silnie anizotropowe.
-
Analysis of magnetic field inside of vessel during degaussing process
PublicationPole magnetyczne wewnątrz okrętu podczas procesu demagnetyzacji może być niebezpieczne dla urządzeń elektronicznych. Demagnetyzacja okrętu jest przeprowadzana w celu minimalizacji namagnesowania stałego. W pracy przedstawiono wyniki analizy pola magnetycznego wewnątrz okrętu podczas procesu demagnetyzacji. Analizę numeryczną przeprowadzono w pakiecie OPERA 3D.
-
Design Optimization of an Anisotropic Magnetoresistance Sensor for Detection of Magnetic Nanoparticles
Publication -
Time Dependent Influence of Rotating Magnetic Field on Bacterial Cellulose
Publication -
Contact angle of the ferronanofluid and influence of the magnetic field on the drying droplet
Publication -
Effect of rotating magnetic field on ferromagnetic structures used in hyperthermia
Publication -
Magnetic penetration depth and correlation length in the superconductor with local pairing
Publication -
Bifunctional magnetic-upconverting luminescent cellulose fibers for anticounterfeiting purposes
Publication -
Synthesis and Characterization of Magnetic Nanomaterials with Adsorptive Properties of Arsenic Ions
Publication -
Magnetic Covalent Organic Frameworks—Fundamentals and Applications in Analytical Chemistry
Publication -
Magnetic, thermodynamic, and magnetotransport properties of CeGaGe and PrGaGe single crystals
Publication -
Magnetic composite adsorbents of phenolic compounds with superior corrosion resistance
Publication -
Flexomagneticity in buckled shear deformable hard-magnetic soft structures
PublicationThis research work performs the first time exploring and addressing the flexomagnetic property in a shear deformable piezomagnetic structure. The strain gradient reveals flexomagneticity in a magnetization phenomenon of structures regardless of their atomic lattice is symmetrical or asymmetrical. It is assumed that a synchronous converse magnetization couples both piezomagnetic and flexomagnetic features into the material structure....
-
Optimization of carbamazepine photodegradation on defective TiO2-based magnetic photocatalyst
PublicationIn this work, carbamazepine (CBZ) degradation over defective Fe3O4@SiO2/d-TiO2/Pt photocatalyst was studied. Within the titania structure, Ti vacancies and Pt nanoparticles were introduced to enhance the photocatalyst’s light absorption and influence charge carriers’ mobility. For the carbamazepine degradation, process parameters, e.g., temperature, flux intensity, photocatalyst loading, aeration, pH, and addition of H2O2, were optimized...
-
Magnetic hyperfine modulation of charge photogeneration in solid films of Alq3.
PublicationZewnętrzne pole magnetyczne (B=100mT) zwiększa fotoprzewodnictwo w hydro-sychinolinowym kompleksie aluminium (Alq3) o 6%. W silniejszych polach magnetycznych (B>100mT) wielkość efektu osiąga stałą wartość. Zaobserwowane wyniki doświadczalne wyjaśniono biorąc pod uwagę magnetyczno-polową modulację oddziaływań nadsubtelnych singletowych i trypletowych par elektron-dziurawy tworzonych w procesie fotogeneracji ładunku.
-
The experimental method of reducing magnetic field intensity in industrial buidings
PublicationPrzedstawiono metodę obniżenia poziomu intensywności zakłóceń w budynkach pracującego zakładu przemysłowego. Potrzeba wykonania badań pola elektromagnetycznego wynikała m.in. z zaobserwowanej wśród pracowników jednego z działów zakładu większej podatności na zachorowania. Na drodze pomiarów zlokalizowano źródła silnego pola magnetycznego w zakresie małych częstotliwości. Na podstawie analizy wyników pomiarowych sformułowano wnioski...
-
Measurement Campaign and Mathematical Model Construction for the Ship Zodiak Magnetic Signature Reproduction
PublicationThe paper presents the partial work done within the framework of the EDA Siramis II project focused on magnetic signature reproduction of ships. Reproduction is understood here as the ability to determine the magnetic anomaly of the local Earth magnetic field in any direction and at any measurement depth due to the presence of the analysed object. The B-91 type hydrographic ship Zodiak was selected as the real case study. The work...
-
Probing the Magnetic Anisotropy of Co(II) Complexes Featuring Redox-Active Ligands
PublicationCoordination complexes that possess large magnetic anisotropy (otherwise known as zero-field splitting, ZFS) have possible applications in the field of magnetic materials, including single molecule magnets (SMMs). Previous studies have explored the role of coordination number and geometry in controlling the magnetic anisotropy and SMM behavior of high-spin (S = 3/2) Co(II) complexes. Building upon these efforts, the present work...
-
Quasi-one-dimensional exchange interactions and short-range magnetic correlations in CuTeO4
PublicationCuTeO4 has been proposed as a crystallographically distinct, yet electronic structure analog, of the superconducting cuprates. Here, we present a detailed characterization of the physical properties of CuTeO4 to address this proposal. Fitting of magnetic susceptibility data indicates unexpected quasi-one-dimensional, antiferromagnetic correlations at high temperature, with a nearest-neighbor Heisenberg exchange of 1=164(5) K....
-
T1 RELAXATION TIME CALLIBRATION IN MAGNETIC RESONANCE IMAGING USING NANODIAMOND PHANTOMS
PublicationMRI is increasingly used in radiation treatment planning because of the excellent soft tissue contrast in the obtained images. It allows more precise definition of the boundaries between healthy tissues and those affected by cancerous lesions. To obtain good image quality, the difference in signal between two types of tissue must be significant despite the noise so it must be properly calibrated. This calibration includes...
-
Sensitivity of entanglement decay of quantum-dot spin qubits to the external magnetic field
PublicationWe study the decay of entanglement of quantum-dot electron-spin qubits under hyperfine-interaction-mediated decoherence.We show that two-qubit entanglement of a single entangled initial state may exhibit decay characteristic of two disentanglement regimes in a single sample, when the externalmagnetic field is changed. The transition is manifested by the suppression of time-dependent entanglement oscillations which are superimposed...
-
Discussion of Derivability of Local Residual Stress Level from Magnetic Stray Field Measurement
PublicationThe NDT procedure dubbed ‘metal magnetic memory’ method and the related ISO 24497 standard has found wide industrial acceptance in some countries, mainly in Russia and China. The method has been claimed by some researchers (Roskosz and Bieniek in NDT&E Int 45:55–62, 2012; Wilson et al. in Sens Actuators A 135:381–387, 2007) as having potential for quantitative determination of local residual stress state in engineering structures,...
-
Representation of magnetic hysteresis in tape wound core using feedback Preisach model
PublicationThis paper presents a mathematical model for the hysteresis phenomenon in ferromagnetic tape wound core. The feedback scalar Preisach model of hysteresis is used to simulate magnetic behavior of the grain oriented silicon strip of ET114-27 type. Determination of B-H hysteretic curve is based on measurement of the initial magnetization curve and the main hysteresis loop. The Preisach distribution function (PDF) of ET114-27 material...
-
New trifunctional acrylic water-based paint with self-cleaning, biocidal and magnetic properties
PublicationIn the present study, we report the synthesis and application of ZnFe2O4/SiO2-TiO2 nanocomposites with nonstoichiometric content of Fe to Zn used for the first time for the preparation of new generation trifunctional paints with self-cleaning, biocidal and magnetic properties. Currently, there are no compositions on the market for obtaining protective coatings in the form of paint, which simultaneously exhibit biocidal, magnetic...
-
Structure and magnetic properties of BeO-Fe2O3-Al2O3-TeO2 glass-ceramic composites
PublicationIn this work, glass-ceramics in the xBeO–20Fe2O3–(80-x)TeO2 system with x = 0–25 mol% were synthesized by the traditional melt quenching route and studied by inductively coupled plasma optical emission spectroscopy, X-ray diffraction, confocal microscopy, infrared and Raman spectroscopy. BeO addition was found to support the crystallization process of Fe2O3 during melting, and an increased BeO content was associated with an increased...
-
Static electric and magnetic multipole susceptibilities for Dirac one-electron atoms in the ground state
PublicationWe present tabulated data for several families of static electric and magnetic multipole susceptibilities for hydrogenic atoms with nuclear charge numbers from the range $1\leq Z\leq137$. Atomic nuclei are assumed to be point-like and spinless. The susceptibilities considered include the multipole electric polarizabilities $\alpha_{\mathrm{E}L\to\mathrm{E}L}$ and magnetizabilities (magnetic susceptibilities) $\chi_{\mathrm{M}L\to\mathrm{M}L}$...
-
Analysis of magnetic field distribution inside ferromagnetic thin shells during degaussing process
PublicationAnalysis of the demagnetization of a large ferromagnetic object like a ship, was conducted. The approximate mathematical model in the form of a long cylindrical shell of constant magnetic permeability was applied. The discrete degaussing winding was assumed and the current density and magnetic flux density distribution in the ferromagnetic shell wall were determined. Based on the frequential and temporal analysis the recommended...
-
Propagation of initially sawtooth periodic and impulsive signals in a quasi-isentropic magnetic gas
PublicationThe characteristics of propagation of sawtooth periodic and impulsive signals at a transducer are analytically studied in this work. A plasma under consideration is motionless and uniform at equilibrium, and its perturbations are described by a system of ideal magnetohydrodynamic equations. Some generic heating/cooling function, which in turn depends on equilibrium thermodynamic parameters, may destroy adiabaticity of a flow and...
-
Nonlinear Model of Synchronous Generator for Autonomous Electrical Power Systems Analysis
PublicationThis paper presents the nonlinear lookup table model for synchronous generator (SG) analysis. The saturation effects of the SG magnetic circuit have been considered. The saturated characteristic of the SG magnetic circuit are based on the open circuit saturation curve for magnetizing inductances. The model has been implemented into the Synopsys/Saber software using the MAST modelling language. To implement the no-load voltage characteristic...
-
Magnetoacoustic Heating in Nonisentropic Plasma Caused by Different Kinds of Heating-Cooling Function
PublicationThe nonlinear phenomena which associate with magnetoacoustic waves in a plasma are analytically studied. A plasma is an open system with external inflow of energy and radiation losses. A plasma’s flow may be isentropically stable or unstable. The nonlinear phenomena occur differently in dependence on stability or instability of a plasma’s flow. The nonlinear instantaneous equation which describes dynamics of nonwave entropy mode...
-
Multi-stage magnetic-fluid seals for operating in water - life test procedure, test stand and research results. Part II Results of life tests of multi-stage magnetic - fluid seal operating in water
PublicationThe edge criteria for magnetic-fluid seals durability research were described in previous article [24] and now the tests results are presented. The tests were made with three magnetic fluids using various magnets quantity in magnetic assemblies. If values obtained in the repeated test deviated by more than 10 % from results of the first test an additional control test was made for final characteristics. The characteristics are:...
-
Magnetic field gradient as the most useful signal for detection of flaws using MFL technique
PublicationThe magnetic flux leakage (MFL) technique is extensively used for detection of flaws as well as for evaluation of their dimensions in ferromagnetic materials. However, proper analysis of the MFL signal is hindered by the MFL sensor velocity causing distortions of this signal. Traditionally measured components of the MFL signal are particularly sensitive to the scanning velocity. In this paper, an another signal – the gradient of...
-
Zero phase shift digital filtering for assessment of exposure to non-sinusoidal magnetic fields
PublicationAccuracy of assessment of human body exposure to magnetic fields is affected by several uncertainty sources. One of them is estimation of the total exposure to non-sinusoidal fields. Standard methods can be implemented using analogue or digital filters that introduce a phase shift that affect the result of total exposure level estimation. The paper presents a new method that allows performing more precise assessment of exposure...
-
Magnetic semiconductor photocatalysts for the degradation of recalcitrant chemicals from flow back water
PublicationIn the present study treatability of persistent organic compounds from the flow back water after hydrauling fracturing was investigated. The combination of TiO2 photocatalyst and magnetic oxide nanoparticles enhance the separation and recoverable property of nanosized TiO2 photocatalyst. Fe3O4/ TiO2 and Fe3O4@SiO2/TiO2 nanocomposites were prepared by heteroagglomeration. The photocatalysts’ characteristics by X-ray diffractometry...
-
The influence of magnetic particle incorporation on bisphenol A removal by β-cyclodextrin-derived sorbent
PublicationA novel, biomass-derived hybrid sorbent Ban-CD-EPI-Fe was successfully synthesized in a coprecipitation method, in which β-cyclodextrin copolymerized with banana peel extract and epichlorohydrin was grafted onto an iron oxide surface. The composition, presence of functional groups, morphology, thermal stability, and magnetic properties of the obtained material were characterized by Powder X-Ray Diffraction (XRD), X-Ray Photoelectron...
-
Modelling of axial magnetic field effect on electric arc in ablation capillaries
PublicationBadano wpływ osiowego pola magnetycznego na łuk elektryczny w kapilarze ablacyjnej o średnicy do 3 mm. Wyniki porównywano z kapilarą ceramiczną. Łuk zasilany był z baterii kondensatorów prądem do około 1200 A. Stosowano pole magnetyczne wolnozmienne oraz wysokoczęstotliwościowe o indukcji do 10 T. Stwierdzono nawet 3-krotny wzrost napięcia łukowego pod wpływem osiowego pola magnetycznego w kapilarze gazującej, przy braku reakcji...