Search results for: ACOUSTIC VECTOR SENSOR, DIGITAL SIGNAL PROCESSOR
-
Macrocyclic derivatives of imidazole as chromoionophores for bismuth(III)/lead(II) pair
Publication18-membered diazomacrocycles with imidazole or 4-methylimidazole residue as a part of macrocycle were used as chromoionophores in bismuth(III) and lead(II) dual selective optodes for the first time. Cellulose triacetate membranes doped with macrocyclic chromoionophores are bismuth(III) and lead(II) selective with color change from orange/red to different shades of blue and violet, respectively. Results obtained for model and real...
-
Gas Detection Using Resistive Gas Sensors And Radial Basis Function Neural Networks
PublicationWe present a use of Radial Basis Function (RBF) neural networks and Fluctuation Enhanced Sensing (FES) method in gas detection system utilizing a prototype resistive WO3 gas sensing layer with gold nanoparticles. We investigated accuracy of gas detection for three different preprocessing methods: no preprocessing, Principal Component Analysis (PCA) and wavelet transformation. Low frequency noise voltage observed in resistive gas...
-
The evaluation of eGlasses eye tracking module as an extension for Scratch
PublicationIn this paper we present the possibility of using eGlasses eye tracking module as an extension for Scratch programming tool which is a visual programming language supporting computer skills learning. The main concept behind this project is to setup the interface for rapid interaction design. Eye tracking is a powerful tool for hands free communication but for that requires a dedicated software. This software is rarely tailored...
-
Quality prediction of foil capacitors by acoustic emission signals
PublicationJakość i trwałość kondensatorów foliowych jest zależna od ich warunków pracy (np. nadmiarowego napięcia pracy, temperatury, wilgotności) oraz od potencjalnych defektów wprowadzonych na różnych etapach wytwarzania kondensatorów. Nieustanny nacisk na wzrost jakości wytwarzanych elementów przy jednoczesnej redukcji kosztów wytwarzania oznacza, że nowe, tanie i szybkie metody predykcji jakości tych elementów są mocno poszukiwane. W...
-
Transiluminacyjne monitorowanie stanu przestrzeni podpajęczynówkowej
PublicationTransiluminacja tkanek ludzkiego ciała w celach diagnostycznych jest stosowana od ponad stu lat. Metoda transiluminacji w bliskiej podczerwieni z rozpraszaniem zwrotnym (NIRT-BSS) umożliwia ciągłe, bezinwazyjne monitorowanie zmian szerokości przestrzeni podpajęczynówkowej, które może być cennym narzędziem w ocenie zagrożenia obrzękiem mózgu. W rozprawie przedstawiono optyczny model rozchodzenia się promieniowania podczerwonego...
-
Pipelined Two-Operand Modular Adders
PublicationPipelined two-operand modular adder (TOMA) is one of basic components used in digital signal processing (DSP) systems that use the residue number system (RNS). Such modular adders are used in binary/residue and residue/binary converters, residue multipliers and scalers as well as within residue processing channels. The structure of pipelined TOMAs is usually obtained by inserting an appropriate number of pipeline register layers within...
-
Computer vision techniques applied for reconstruction of seafloor 3D images from side scan and synthetic aperture sonars data
PublicationThe Side Scan Sonar and Synthetic Aperture Sonar are well known echo signal processing technologies that produce 2D images of the seafloor. Both systems combines a number of acoustic pings to form a high resolution image of seafloor. It was shown in numerous papers that 2D images acquired by such systems can be transformed into 3D models of seafloor surface by algorithmic approach using intensity information, contained in a grayscaled...
-
Playback detection using machine learning with spectrogram features approach
PublicationThis paper presents 2D image processing approach to playback detection in automatic speaker verification (ASV) systems using spectrograms as speech signal representation. Three feature extraction and classification methods: histograms of oriented gradients (HOG) with support vector machines (SVM), HAAR wavelets with AdaBoost classifier and deep convolutional neural networks (CNN) were compared on different data partitions in respect...
-
Improved RSS-Based DoA Estimation Accuracy in Low-Profile ESPAR Antenna Using SVM Approach
PublicationIn this paper, we have shown how the overall performance of direction-of-arrival (DoA) estimation using lowprofile electronically steerable parasitic array radiator (ESPAR) antenna, which has been proposed for Internet of Things (IoT) applications, can significantly be improved when support vector machine (SVM) approach is applied. Because the SVM-based DoA estimation method used herein relies solely on received signal strength...
-
SYNAT_PCA_48
Open Research DataThere is a series of datasets containing feature vectors derived from music tracks. The dataset contains 51582 music tracks (22 music genres) and feature vector after Principal Component Analysis (PCA) performing, so there are 48-element vectors derived from music excerpts. Originally, a feature vector containing 173 elements was conceived in earlier...
-
SYNAT_PCA_11
Open Research DataThe dataset contains 51582 music tracks (22 music genres) and feature vector after Principal Component Analysis (PCA) performing, so there are 11-element vectors derived from music excerpts. Originally, a feature vector containing 173 elements was conceived in earlier research studies carried out by the team of authors [1-6]. A collection of more than...
-
RSS-Based DoA Estimation Using ESPAR Antenna Radiation Patterns Spline Interpolation
PublicationIn this paper, it is shown how power pattern crosscorrelation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at electronically steerable parasitic array radiator (ESPAR) antenna output port, used for direction-of-arrival (DoA) estimation, can easily be improved by applying spline interpolation to radiation patterns recorded in the calibration phase of the DoA estimation process. The proposed method...
-
A novel calibration method for RSS-based DoA estimation using ESPAR antennas
PublicationIn this paper, we introduce a new calibration method that can successfully be used in direction of arrival (DoA) estimation using electronically steerable parasitic array radiator (ESPAR) antennas and employing power-pattern cross-correlation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at the antenna output port. Instead of the commonly used two-step approach, during which ESPAR antenna calibration...
-
RSS-based DoA Estimation Using ESPAR Antennas and Interpolated Radiation Patterns
PublicationIn this letter, it is shown how an algorithm, which employs received signal strength (RSS) values in order to estimate direction-of-arrival (DoA) of impinging signals in wireless sensor network (WSN) nodes equipped with electronically steerable parasitic array radiator (ESPAR) antennas, can easily be improved by applying an interpolation algorithm to radiation patterns recorded in the calibration phase of the DoA estimation process....
-
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublicationThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Dynamic GNSS Mission Planning Using DTM for Precise Navigation of Autonomous Vehicles
PublicationNowadays, the most widely used method for estimating location of autonomous vehicles in real time is the use of Global Navigation Satellite Systems (GNSS). However, positioning in urban environments using GNSS is hampered by poor satellite geometry due to signal obstruction created by both man-made and natural features of the urban environment. The presence of obstacles is the reason for the decreased number of observed satellites...
-
Noise sources in Raman spectroscopy of biological objects
PublicationWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
Portable raman spectrometer for maritime security applications
PublicationThe fast identification of explosives, narcotics and other chemicals carried on board of ships or transported in containers to the harbors is an important problem of maritime security. Raman spectroscopy is widely used for fast identification of various chemicals. Continuous progress in the field of photonics has resulted in commercial availability of low-power compact Raman spectrometers which can be integrated into portable systems....
-
Incorporation of nitrogen in diamond films – A new way of tuning parameters for optical passive elements
PublicationThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy (AFM), confocal...
-
Embedded system using Bluetooth Low Energy sensors for smart farming applications
PublicationThe main goal of this Bachelor of Engineering project titled Embedded system using Bluetooth Low Energy sensors for smart farming applications is to create a prototype of a system consistent with Agriculture 4.0 concept using Bluetooth Low Energy (BLE) technology. Developed solution shall be easy in implementation and its main functionality shall be periodic gathering of data from environmental sensors...
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Open Research DataWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Open Research DataThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Reliability and types of diagnosis in the process of diesel engine operation
PublicationThe article presents complexity of the problem concerning development of diagnosis with defined reliability by a diagnosing system (SDG) on technical condition of marine combustion engines, especially main engines. It was shown that development of the final diagnosis, the so-called initial operation diagnosis, on the operational usability (fDG on PEx) of a main engine in particular, is not possible without prior development of...
-
Ochrona odbiorników GNSS przed zakłóceniami celowymi
PublicationArtykuł dotyczy zastosowania algorytmów przestrzennego cyfrowego przetwarzania sygnałów dla potrzeb selektywnej eliminacji sygnałów zakłócających pracę odbiorników nawigacji satelitarnej GNSS. Omówiono podatność tych odbiorników na ataki elektroniczne typu zagłuszanie oraz spoofing. Polegają one na celowej emisji sygnałów niepożądanych w paśmie pracy systemu. Następnie przedstawiono koncepcję przeciwdziałania tego rodzaju zakłóceniom...
-
Incorporation of nitrogen in diamond films - A new way of tuning parameters for optical passive elements
PublicationThis paper investigates the impact of nitrogen incorporation in diamond films for the construction of an interferometric sensor to measure displacement. Diamond films with different nitrogen levels (0–5%) were deposited on silicon substrates by microwave plasma enhanced chemical vapor deposition. The structural characteristics of these samples are characterized using scanning electron microscopy (SEM), atomic force microscopy...
-
A High-Efficient Measurement System With Optimization Feature for Prototype CMOS Image Sensors
PublicationIn this paper, a gray-scale CMOS image sensor (CIS) characterization system with an optimization feature has been proposed. By using a very fast and precise control of light intensity, based on the pulsewidth-modulation method, it is avoided to measure the illuminance every time. These features accelerate the multicriteria CIS optimization requiring many thousands of measurements. The system throughput is 2.5 Gb/s, which allows...
-
Low-Profile ESPAR Antenna for RSS-Based DoA Estimation in IoT Applications
PublicationIn this paper, we have introduced a low-profile electronically steerable parasitic array radiator (ESPAR) antenna that can successfully be used to estimate the direction-of-arrival (DoA) of incoming signals in wireless sensor network (WSN) applications, in which the height of the complete antenna has to be low. The proposed antenna is over three times lower than high-profile ESPAR antenna designs currently available in the literature...
-
Supercomputing Grid-Based Services for Hearing Protection and Acoustical Urban Planning, Research and Education
PublicationSpecific computational environments, so-called domain grids, are developed within the PLGrid Plus project in order to prepare specialized IT solutions, i.e., dedicated software implementations and hardware (infrastructure adaptation), suited for particular research group demands. One of the PLGrid Plus domain grids, presented in this paper, is Acoustics. The article describes in detail two kinds of the acoustic domain services....
-
A Novel Method for Intelligibility Assessment of Nonlinearly Processed Speech in Spaces Characterized by Long Reverberation Times
PublicationObjective assessment of speech intelligibility is a complex task that requires taking into account a number of factors such as different perception of each speech sub-bands by the human hearing sense or different physical properties of each frequency band of a speech signal. Currently, the state-of-the-art method used for assessing the quality of speech transmission is the speech transmission index (STI). It is a standardized way...
-
DoA Estimation Using Reconfigurable Antennas in Millimiter-Wave Frequency 5G Systems
PublicationTo achieve low latency and high throughputs, future 5G systems will have to utilize complex antenna systems able to provide beamforming and direction-of-arrival (DoA) estimation capabilities. Most of the concepts available in the literature rely on analog or digital beamforming, which is well developed and can be used both at a base station and in a user terminal. However, in applications, in which...
-
Comparison of noise reduction methods in radiometric correlation measurements of two-phase liquid-gas flows
PublicationTwo-phase liquid-gas flows occur frequently in the mining, energy, chemical, and petrochemical industries. One of non-contact methods used to analyse these flows is the gamma ray absorption method. However, the signals received from radiation detectors contain a significant stochastic noise, which makes them difficult to analyse. The article describes four methods of noise reduction in cross-correlation measurements of water-air...
-
Distortion of speech signals in the listening area: its mechanism and measurements
PublicationThe paper deals with a problem of the influence of the number and distribution of loudspeakers in speech reinforcement systems on the quality of publicly addressed voice messages, namely on speech intelligibility in the listening area. Linear superposition of time-shifted broadband waves of a same form and slightly different magnitudes that reach a listener from numerous coherent sources, is accompanied by interference effects...
-
Creating a Realible Music Discovery and Recomendation System
PublicationThe aim of this paper is to show problems related to creating a reliable music dis-covery system. The SYNAT database that contains audio files is used for the purpose of experiments. The files are divided into 22 classes corresponding to music genres with different cardinality. Of utmost importance for a reliable music recommendation system are the assignment of audio files to their appropriate gen-res and optimum parameterization...
-
A Numerical Study on Baseline-Free Damage Detection Using Frequency Steerable Acoustic Transducers
PublicationIn structural health monitoring (SHM) a considerable amount of damage detection algorithms based on guided waves (GW) have been developed. Most of them rely on extensive transducer networks, besides preliminary reference measurements of the structures. This originated a growing demand for hardware simplification and cost reduction of the wave-based SHM methods, driving the conception of new solutions enabling both: the reduction...
-
Iterative learning approach to active noise control of highly autocorrelated signals with applications to machinery noise
PublicationThis paper discusses the design and application of iterative learning control (ILC) and repetitive control (RC) for high modal density systems. Typical examples of these systems are structural and acoustical systems considered in active structural acoustic control (ASAC) and active noise control (ANC) applications. The application of traditional ILC and RC design techniques, which are based on a parametric system model, on systems...
-
Application of an Electronic Nose Instrument to Fast Classification of Polish Honey Types
PublicationThe paper presents practical utilization of an electronic nose prototype, based on the FIGARO semiconductor sensors, in fast classification of Polish honey types—acacia flower, linden flower, rape, buckwheat and honeydew ones. A set of thermostating modules of the prototype provided gradient temperature characteristics of barbotage-prepared gas mixtures and stable measurement conditions. Three chemometric data analysis methods...
-
Data Integration from GPS and Inertial Navigation Systems for Pedestrians in Urban Area
PublicationThe GPS system is widely used in navigation and the GPS receiver can offer long-term stable absolute positioning information. The overall system performance depends largely on the signal environments. The position obtained from GPS is often degraded due to obstruction and multipath effect caused by buildings, city infrastructure and vegetation, whereas, the current performance achieved by inertial navigation systems (INS) is still...
-
Methods of data extraction from sub-bottom profiler's signal
PublicationData obtain during sounding Gdansk Bay with SES-2000 Standard parametric sub-bottom profiler has two types of information: envelope and pure signal. First is used to plot echograms in real time and contain envelope of echo. The second one is stored during sounding and can be processed after recording data. Comparison of results will be shown and discussed. First step in investigation was proper configuration of small measurement...
-
Calibration of NTC 10k thermistors in temperature of 0 C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 100 C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 50 C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Ordered titanium templates functionalized by gold films for biosensing applications – Towards non-enzymatic glucose detection
PublicationRecently, metal nanostructures evoke much interest due to application potential in highly sensitive detectors in biochemistry and medical diagnostics. In this work we report on preparation and characteristics of thin (1–100 nm) Au films deposited onto highly ordered structured titanium templates for SERS (Surface Enhanced Raman Spectroscopy) and electrochemical sensing. The Ti templates are formed by selective removal of TiO2 nanotubes...