displaying 1000 best results Help
Search results for: ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY
-
The high impedance measuring probe for gain-phase analysers.
PublicationAutorzy opracowali tanią sondę pomiarową przeznaczoną do pracy z analizatorami gain-phase jak Solartron 1260 Impedance/Gain-phase Analyser, 1255 Frequency Response Analyser (FRA) lub starszymi wersjami 1250, 1253. Przedstawiona architektura sondy wyznacza jej parametry metrologiczne. Pomiary możliwe są w 8 zakresach obejmujących wartości 100ohm<|Zx|<100Gohm w szerokim zakresie częstotliwości 10uHz-1MHz. Obwód wejściowy sondy pozwala...
-
Synthesis and electrochemical characteristics of novel dithiocarbamate polymers
PublicationNovel dithiocarbamate compounds have been obtained by reacting a linear poly(ethylenimine)polymer, MW 50,000, with CS2. The resulting anionic polymers contain, depending on the reaction conditions, up to two sulfur atoms per one nitrogen atom (approx. 40% w/w). The polymers are soluble in dimethylsulfoxide and insoluble in acetonitrile solutions. In both solvents they are electrochemically active, in the latter case as a cast film...
-
Raman spectroscopy analysis of molecular configuration forms of the macular xanthophylls
Publication -
New Methods of Spectral Analysis of Current Oscillations of Electrochemical Processes
Publication -
New insights on lithium storage in silicon oxycarbide/carbon composites: Impact of microstructure on electrochemical properties
PublicationIn this work, we study the impact of the preceramic precursor vinyltriethoxysilane (VTES) on the electrochemical performance of silicon oxycarbide (SiOC) glass/graphite composites. We apply an innovative approach based on high-power ultrasounds in order to obtain highly homogenous composites with a uniform distribution of small graphitic flakes. This procedure enhances gelation and drying of VTES-based preceramic polymer/graphite...
-
Applicability of an effective conductivity approach in modeling thoracic impedance changes
PublicationThis paper describes numerical simulations of the influence of conductivity changes inside a volume conductor on impedance changes measured on its surface. A simple model based on the finite element method has been developed to estimate an applicability of the effective conductivity theory in human chest modeling. The model consisted of a cylinder with two concentric spheres inside. Simulations were performed for two cases: first...
-
Application of spectroscopy to the measurement of blood parameters
PublicationSpectroscopy is the study of formation and interpretation of the spectra arising from the interactions of all types of radiation on matter, understood as a collection of atoms and molecules. This is a very important department of optics which gives us many opportunities to measure various parameters such as material blood parameters. Among the diseases that are associated significantly with changes in rheological properties of...
-
Molecular level interpretation of excess infrared spectroscopy
PublicationInfrared (IR) spectroscopy is an invaluable tool in studying intermolecular interactions in solvent mixtures. The deviation of the IR spectrum of a mixture from the spectra of its pure components is a sensitive measure of the non-ideality of solutions and the modulation of intermolecular interactions introduced by mutual influence of the components. Excess IR spectroscopy, based on the established notion of excess thermodynamic...
-
Multi-objective design of miniaturized impedance transformers by domain segmentation
PublicationFast multi-objective design optimization of compact microstrip impedance transformers is discussed. Our approach exploits approximation models constructed using sampled coarse- mesh EM simulation data in a partitioned design space and response correction techniques for design refinement. Demonstra
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublicationIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
FTIR, Raman spectroscopy and HT-XRD in compatibility study between naproxen and excipients
PublicationDetection of incompatibility between an active pharmaceutical ingredient (API) and excipients, including the selection of the most biopharmaceutical advantageous excipients is extremely important in the pre-formulation process of developing a solid dosage form technology. Therefore, having fast and reliable methods for identifying incompatibility is fundamental in pharmaceutical technology. For this purpose, combined Fourier transform...
-
Methods of trend removal in electrochemical noise data – overview
PublicationIn this paper we shall review popular methods of trend removal from electrochemical noise time records. The basic principles of operation of the six most popular methods are explained. The proposed methods are: high - pass filtering, Moving Average Removal, polynomial detrending, wavelet detrending, Empirical Mode Decomposition and Variational Mode Decomposition. Estimation of trend removal quality...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublicationIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
Electrochemical capacitor temperature fluctuations during charging/discharging processes
PublicationThepaperpresentsaproposalofusingadditionalstatisticalparameterssuchas:standarddeviation,variance, maximum and minimum increases of the observed value that were determined during measurements of temperature fields created on the surface of the tested electrochemical capacitor. The measurements were carriedoutusingthermographicmethodsinordertosupportassessmentoftheconditionofelectrochemical capacitorunderclassicdurabilitytestsbasedonmethodsofdeterminationofcapacityandequivalentseries...
-
The influence of nanostructures size on V2O5 electrochemical properties as cathode materials for lithium ion battery
PublicationIn this paper, V2O5 nanostructures with a size depending on the annealing temperature are successfully synthesized by a sol-gel method. The crystal structure and morphology of samples are characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), selected area electron diffraction (SEAD) and scanning electron microscopy (SEM), respectively. Electrochemical testing such...
-
Impedance monitoring of carbon steel cavitation erosion under the influence of corrosive factors
PublicationW pracy przedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej oraz funkcję ubytku masy powszechnie stosowaną do oceny odporności kawitacyjnej materiałów. Oszacowanie stopnia degradacji powierzchni, a także wpływu erozji na odporność korozyjną jest możliwe po zastosowaniu odpowiedniego elektrycznego...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Electrochemical synthesis and characterization of nanocomposites based on poly(3,4-ethylenedioxythiophene) and functionalized carbon nanotubes
PublicationThis work is focused on new composite materials consisting of poly(3,4-ethylenedioxythiophene) (pEDOT) and functionalized multi-walled carbon nanotubes synthesized electrochemically. Three types of composites were synthesized: the first one containing carbon nanotubes with carboxyl groups (covalent functionalization), the second one containing oxidized carbon nanotubes ox-MWCNTs (with different oxygen-rich polar groups) (covalent...
-
Harmonic Synthesis: A Novel Electrochemical Method for Corrosion Rate Moni-toring
PublicationPraca przedstawia metodę wyznaczania chwilowej szybkości korozji metali opa-rtą na pomiarach prądów harmonicznych elektrody pobudzanej sinusoidalnym sy-gnałem napięciowym o niskiej częstotliwości i amplitudzie rzędu 10-30 mV,zapewniającej nieniszczący charakter badań. Opisano podstawy teoretyczne tejmetody nazwanej syntezą harmoniczną (SH). Jest ona oparta na dyskretnej syn-tezie quasi-stacjonarnej krzywej polaryzacji z prądów...
-
Nitrogen-incorporated boron-doped diamond films for enhanced electrochemical supercapacitor performance
PublicationThe electrochemical (EC) supercapacitor, known for its rapid charging, reliability, and versatile applications, demands optimized electrode characteristics and an understanding of their electrochemical behaviour. Although boron-doped diamond (BDD) holds promise as a supercapacitor electrode, a crucial gap exists in comprehending its material behaviour under specific growth conditions. Here, nitrogen-incorporated BDD (N-BDD) films...
-
Applications of Raman spectroscopy for detection of selected substances in tissues
PublicationThis dissertation explores the applications of Raman spectroscopy for biological tissue analysis. Basics of Raman and surface-enhanced Raman spectroscopy (SERS) are described, along with an analysis of the literature on biodetection and non-invasive blood analysis with emphasis on glucose detection. Instrumentation for Raman measurements is described. The sources of noise and interferences occurring in biological tissue measurements...
-
High-Temperature Oxidation of Heavy Boron-Doped Diamond Electrodes: Microstructural and Electrochemical Performance Modification
PublicationIn this work, we reveal in detail the effects of high-temperature treatment in air at 600 °C on the microstructure as well as the physico-chemical and electrochemical properties of boron-doped diamond (BDD) electrodes. The thermal treatment of freshly grown BDD electrodes was applied, resulting in permanent structural modifications of surface depending on the exposure time. High temperature affects material corrosion, inducing...
-
Comparison of Impedance-Source Networks for Two and Multilevel Buck–Boost Inverter Applications
Publicationmpedance-source networks are an increasingly popular solution in power converter applications, especially in single-stage buck-boost power conversion to avoid additional front-end dc-dc power converters. In the survey papers published, no analytical comparisons of different topologies have been described, which makes it difficult to choose the best option. Thus, the aim of this paper is to present a comprehensive analytical comparison...
-
Nonlinear Impedance as Possible Result of Ion-Polaron Interaction in Cu2O-Al2O3-SiO2 Glass
PublicationNonlinear a.c. impedance measurements were performed in Cu2O-Al2O3-SiO2 glass in wide frequency range. The obtained results shows that a large nonlinearity in the impedance signal is observed at moderate electric fields of an order 1V/mm. The contents of the third harmonics reaches about 10% and strongly depends on temperature and frequency. The investigated glass exhibits mixed electronic-ionic conductivity. Electronic conduction...
-
Dielectric Spectroscopy Studies and Modelling of Piezoelectric Properties of Multiferroic Ceramics
PublicationCompounds and solid solutions of bismuth ferrite (BiFeO3)—barium titanate (BaTiO3) system are of great scientific and engineering interest as multiferroic and potential high-temperature lead-free piezoelectric materials. In the present paper, the results of research on the synthesis and characterisation of 0.67Bi1.02FeO3–0.33BaTiO3 (67BFBT) ceramics in terms of crystal structure and dielectric and piezoelectric properties are reported....
-
Application of the near-infrared spectroscopy in the pharmaceutical technology
PublicationNear-infrared (NIR) spectroscopy is currently the fastest-growing and the most versatile analytical method not only in the pharmaceutical sciences but also in the industry. This review focuses on recent NIR applications in the pharmaceutical technology. This article covers monitoring, by NIR, of many manufacturing processes, such as granulation, mixing or drying, in order to determine the end-point of these processes. In this...
-
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublicationThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode.
PublicationThis study presents a novel approach to impedance measurements. The methodology discussed is limited to contact in the sample-probe system under ambient conditions without the presence of electrolyte. Comparison with results of direct and alternating current measurements for well-defined metallic surfaces are made. In spite of idealization related to the type of contact examined, the proposed technique provides an improvement of...
-
Analysis and characterization of coordination compounds by resonance Raman spectroscopy
PublicationResonance Raman spectroscopy has become a powerful tool to study excited-state geometries, excited-state charge distributions and photoinduced reaction dynamics in coordination compounds. Due to their rich photophysical properties coordination compounds are utilized for a variety of applications ranging from DNA sensing to photocatalysis. This review features recent applications of various resonance Raman scattering techniques...
-
Electrochemical Activity of Electrode Material Consisting of Porous Copper and Silica Aerogel
PublicationElectrochemically obtained copper was combined with silica aerogel (SiO2ag). Obtained composite (SiO2@Cu/CuxOy) was tested as an electrode in contact with LiPF6 in EC/DMC electrolyte. The electrochemical measurements showed the presence of complex redox couple activities of SiO2@Cu/CuxOy. This experiment was employed to help in understanding the carbon role used as an electric contact for silica in Li-Ion batteries and clarify...
-
Noise and Electro-Ultrasonic Spectroscopy of Conducting PolymerThick Films
PublicationThick conducting films based on conducting polymer are characterized by DC conductivity and noise in temperature range 10 to 300 K. Conducting polymers could be used e.g. for the top electrode (cathode) in the solid tantalum or niobium capacitors. On the conducting polymer layer the top layer of carbon/graphite and/or silver polymer based pastes is applied in the capacitor technology. Our samples structure consists of conducting...
-
Determination of the active ingredient in pharmaceutical gel formulation by NIR spectroscopy
PublicationPharmaceuticals of their intended must be thoroughly controlled. The traditional analytical methods are very costly and time consuming. NIR spectroscopy allows to analyze pharmaceutical materials very quickly and with very low costs. First pharmaceutical applications of the NIR spectroscopy appeared with some incuriosity in the late 1960s. Application of NIR in the contemporary pharmaceutical industry is very large. The most common...
-
Linearization in impedance measurements
Publication -
SPECTROSCOPY AND SPECTRAL ANALYSIS
Journals -
Biomedical Spectroscopy and Imaging
Journals -
APPLIED SPECTROSCOPY REVIEWS
Journals -
JOURNAL OF MOLECULAR SPECTROSCOPY
Journals -
Journal of Applied Spectroscopy
Journals -
SPECTROSCOPY-AN INTERNATIONAL JOURNAL
Journals -
EM-Driven Multi-Objective Design of Impedance Transformers By Pareto Ranking Bisection Algorithm
PublicationIn the paper, the problem of fast multi-objective optimization of compact impedance matching transformers is addressed by utilizing a novel Pareto ranking bisection algorithm. It approximates the Pareto front by dividing line segments connecting the designs found in the previous iterations, and refining the obtained candidate solutions by means of poll-type search involving Pareto ranking. The final Pareto set is obtained using...
-
Photoelectron spectroscopy of brominated derivative of pyrimidine: 2-bromopyrimidine
PublicationIn this study the brominated derivative of pyrimidine, 2-bromopyrimidine, was investigated by photoelectron spectroscopy. Outer valence photoelectron spectra recorded at 21.22, 45 and 100 eV photon energy for this compound are presented. The recorded spectra have a higher resolution than that previously reported in the literature. The bromine 3d and 3p edge photoelectron spectra have also been recorded in a photon impact experiment...
-
Electrochemical performance of thin free-standing boron-doped diamond nanosheet electrodes
PublicationIn the following work we describe preparation and the electrochemical performance of thin and free-standing heavy boron-doped diamond (BDD) nanosheets. The investigated foils were deposited on Ta substrate using microwave plasma-enhanced chemical vapor deposition technique (MPECVD). Foils of two B-dopant densities were investigated, obtained on the base of 10 k and 20 k ppm [B]/[C] ratio in the gas admixture. The obtained foils...
-
Instantaneous impedance monitoring of synergistic effect between cavitation erosion and corrosion processes
PublicationThe most common method of determination of cavitation erosion resistance as well as the magnitude of erosion-corrosion synergistic interaction is based on the weight loss measurements. Nondestructive characterization of installations elements is in most cases impossible to perform. Also, such a measurement does not include local types of failure or alteration of operating conditions. There is an urge to elaborate a method for monitoring...
-
Impact of blending with polystyrene on the microstructural and electrochemical properties of SiOC ceramic
PublicationIn this work, we present the electrochemical behavior and microstructural analysis of silicon oxycarbide (SiOC) ceramics influenced by an addition of polystyrene (PS). Polymer-derived ceramics were obtained by pyrolysis (1000°C, Ar atmosphere) of different polysiloxanes prepared by sol–gel synthesis. This method is very effective to obtain desired composition of final ceramic. Two alkoxysilanes phenylthriethoxysilane and diphenyldimethoxysilane...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublicationThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublicationWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...