Filters
total: 8283
-
Catalog
- Publications 6050 available results
- Journals 71 available results
- Conferences 24 available results
- People 85 available results
- Projects 7 available results
- Research Equipment 1 available results
- e-Learning Courses 50 available results
- Events 3 available results
- Open Research Data 1992 available results
displaying 1000 best results Help
Search results for: HIGH STRENGTH STEEL
-
Integrating heterogeneous systems with high-dependability requirements by means of web services
PublicationWeb services are commonly used on boundaries of heterogeneous components in Service Oriented Architecture (SOA) as they provide a universal communication channel not bound to any particular programming language or run-time platform. This paper describes how web services can be used to integrate heterogeneous systems which serve purposes requiring high dependability, reliability and availability. Examples of such systems include...
-
High-performance graphene-based biosensor using a metasurface of asymmetric silicon disks
PublicationIn recent years, optical biosensors widely applicable for medical applications, have received much attention. In this paper, we propose a high-performance polarization-insensitive optical biosensor based on a graphene-dielectric metasurface. The metasurface consists of an asymmetric dielectric disk array that supports a high Q-factor Fano resonance. The provided sharp Fano resonance results in an enhanced light-matter interaction...
-
Seismic damage diagnosis in adjacent steel and RC MRFs considering pounding effects through improved wavelet-based damage-sensitive feature
PublicationThis paper aims to propose complex Morlet (cmorfb-fc) wavelet-based refined damage-sensitive feature (rDSF) as a new and more precise damage indicator to diagnose seismic damages in adjacent steel and Reinforced Concrete (RC) Moment Resisting Frames (MRFs) assuming pounding conditions using acceleration responses. The considered structures include 6- and 9-story steel and 4- and 8-story RC benchmark...
-
ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC
Journals -
TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN
Journals -
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028006171]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028004431]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028005611]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028001151]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [704034723256111]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [504073002800551]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028002671]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028003681]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High-temperature properties of titanium-substituted yttrium niobate
Publicationhe defect fluorite titanium-doped yttrium niobate samples Y3Nb1−xTixO7−δ have been synthesized and investigated by the means of high-temperature X-ray diffraction, dilatometry, and thermogravimetry. Thermal expansion coefficients (TECs) as well as chemical expansion coefficients for material with 5, 10, and 15 mol% of titanium were determined. All investigated samples exhibit chemical contraction caused by Ti doping. The values...
-
Errors of a Linear Current Approximation in High-Speed PMSM Drives
PublicationCurrent sampling techniques and predictive algorithms used in the digital control of electric drives rely on a simple mathematical model that assumes linear current changes upon constant supplying voltages. This paper identifies rotor movement as a factor that makes this assumption invalid when the rotor covers an angular distance of a few tens of degrees during the control interval duration. The errors of the linear current approximation...
-
Influence of magnetic field on wear in high frequency reciprocatingsliding contacts
PublicationResults of experimental studies concerning the influence of permanent magnetic field on wear of dry sliding contact operating at short stroke and high frequency are presented. It was found that horizontal magnetic field with different orientations relative to the sliding direction is affecting performance of the contact. The increase in frequency of sliding reduces accumulated mass loss and lowers the surface roughness of the wear...
-
High-accuracy polarimetric studies on lead germanate single crystals
PublicationA high-accuracy polarimetric technique has been used for the characterization of a lead germanate ferroelectric single crystal. The measurement results of the linear and circular birefringence in the [010] direction at a wavelength of 633 nm under the influence of an electric field are presented. Gyration–electric field hysteresis loops at alternative crystal positions in the polarization system have been used to determine the...
-
Performance of Vector-valued Intensity Measures for Estimating Residual Drift of Steel MRFs with Viscous Dampers
PublicationViscous Dampers (VDs) are widely used as passive energy dissipation system for improving seismic performance levels especially in retrofitting of buildings. Residual Inter-story Drift Ratio (R-IDR) is another important factor that specifies the condition of building after earthquake. The values of R-IDR illustrates the possibility of retrofitting and repairing of a building. Therefore, this study aims to explore the vector-valued...
-
Influence of laser processing of the low alloy medium carbon structural steel on the development of the fatigue crack
PublicationThe paper contains the results of the structural analysis, hardness tests and fatigue tests conducted for the medium carbon structural steel with low content of Cr and Ni after its processing with CO2 laser beam. Pre-cracks were made in the round compact tension (RCT) specimen used for fatigue test. Next, four paths, parallel to each other, were melted on both sides of the samples using a laser beam. The paths were perpendicular...
-
Electrical mapping of AISI 304 stainless steel subjected to intergranular corrosion performed by means of AFM-LIS in the contact mode
PublicationThe paper presents results of the AFM-based approach to local impedance spectroscopy (LIS) measurements performed in a 20 20 lm grid within an austenite grain–grain boundary region for sensitized AISI 304 stainless steel (SS). Maps of electrical parameters obtained on the basis of localized impedance spectra were demonstrated, presenting their changes and correlation with the sample topography. Performed research revealed significant...
-
Teaching High Performance Computing Using BeesyCluster and Relevant Usage Statistics
PublicationThe paper presents motivations and experiences from using the BeesyCluster middleware for teaching high performance computing at the Faculty of Electronics, Telecommunications and Informatics, Gdansk University of Technology. Features of BeesyCluster well suited for conducting courses are discussed including: easy-to-use WWW interface for application development and running hiding queuing systems, publishing applications as services...
-
A New Coupler Concept for Contactless High-Speed Data Transmission Monitoring
PublicationThis paper presents a new concept of a couplerthat can be applied to high-speed data transmission contactlessmeasurements. The proposed approach is dedicated for differentialsignal transmission monitoring in microstrip coupled lineson printed circuit boards (PCBs). The coupler, produced on aseparate PCB, is overlayed on the transmission line with thedifferential signal and delivers decoupled differential signal tothe main measurement...
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [504073002800381]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028005751]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028007661]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028007521]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028008421]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028006011]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028009891]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028003381]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028003631]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028002271]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028003571]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028006841]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028006081]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [50407300280011]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [504073002800431]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028005641]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [504073002800191]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028006181]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028001981]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [7040247104948991]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028007291]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028004731]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028008041]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028009161]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade B-cell lymphoma with MYC and BCL2 and/or BCL6 rearrangements - Male, 57 - Tissue image [5040730028004541]
Open Research DataThis is the histopathological image of RETROPERITONEUM AND PERITONEUM tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
High grade squamous intraepithelial lesion - Female, 29 - Tissue image [8140730001729821]
Open Research DataThis is the histopathological image of CERVIX UTERI tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Study of a Multicriterion Decision-Making Approach to the MQL Turning of AISI 304 Steel Using Hybrid Nanocutting Fluid
PublicationThe enormous use of cutting fluid in machining leads to an increase in machining costs, along with different health hazards. Cutting fluid can be used efficiently using the MQL (minimum quantity lubrication) method, which aids in improving the machining performance. This paper contains multiple responses, namely, force, surface roughness, and temperature, so there arises a need for a multicriteria optimization technique. Therefore,...
-
Pathological and physiological high-frequency oscillations in focal human epilepsy
PublicationHigh-frequency oscillations (HFO; gamma: 40-100 Hz, ripples: 100-200 Hz, and fast ripples: 250-500 Hz) have been widely studied in health and disease. These phenomena may serve as biomarkers for epileptic brain; however, a means of differentiating between pathological and normal physiological HFO is essential. We categorized task-induced physiological HFO during periods of HFO induced by a visual or motor task by measuring frequency,...