Filters
total: 274
Search results for: PULSE MEASUREMENTS
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Images revealing the effect of local femtosecond laser ablation of conductive poly(lactic acid) 3D printed electrodes
Open Research DataThe dataset reveals the images of the femtosecond laser (FSL) ablation at the surface of commercially available carbon black-filled poly(lactic acid) 3D printed electrode. The process is used for the increase of the charge transfer of this electrode in electrochemical studies.
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublicationIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Hybrid Modulation for Modular Voltage Source Inverters with Coupled Reactors
PublicationThis paper proposes and discusses a concept of a hybrid modulation for the control of modular voltage source inverters with coupled reactors. The use of coupled reactors as the integrating elements leads to significant reduction in the size and weight of the circuit. The proposed modulation combines novel coarsely quantized pulse amplitude modulation (CQ-PAM) and innovative space-vector pulse width modulation (SVPWM). The former...
-
Directed electromagnetic pulse dynamics: projecting operators method
PublicationIn this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...
-
Dual drive control under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Comparison of Cadmium Cd2+ and Lead Pb2+ Binding by Fe2O3@SiO2‐EDTA Nanoparticles – Binding Stability and Kinetic Studies
PublicationThis study describes the synthesis and characterization of ethylenediaminetetraacetic acid (EDTA) functionalized magnetic nanoparticles of 20 nm in size – Fe3O4@SiO2‐EDTA – which were used as a novel magnetic adsorbent for Cd(II) and Pb(II) binding in aqueous medium. These nanoparticles were obtained in two‐stage synthesis: covering by tetraethyl orthosilicate and functionalization with EDTA derivatives. Nanoparticles were characterized...
-
Time domain model of the resonance-based electromagnetic pulses emission system
PublicationIn the literature, the emission properties of the electromagnetic field pulse systems based on high voltage antennas (HVR) have been widely described. In order to increase the emission efficiency by extending duration and increasing amplitude of the impulse it is possible to use a resonance system tuned to the parameters of the signal shaped in the pulse forming circuit. The synthesis of a time-domain simulation model of a complex...
-
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Open Research DataThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
The forming and emission of high power electromagnetic pulses
PublicationAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by an...
-
Modular multipulse voltage source inverters with integrating coupled reactors
PublicationA novel approach to the voltage source inverters (VSI) construction is presented in the paper. The invented inverter structures allow to operate several DC/AC converters in parallel resulting in lower voltage distortions at extremely low switching frequency. The research presented in the paper describes such a parallel operation of the VSI’s which is possible thanks to the use of coupled inductors. The eighteen-pulse and twenty-four-pulse...
-
The Influence of Laser Alloying of Ti13Nb13Zr on Surface Topography and Properties
PublicationThe laser alloying is a continually developing surface treatment because of its significant and specific structuration of a surface. In particular, it is applied for Ti alloys, being now the most essential biomaterials` group for load-bearing implants. The present research was performed on the Ti13Nb13Zr alloy subject to laser modification in order to determine the treatment effects on surface topography and its some mechanical...
-
Blood Pressure Estimation Based on Blood Flow, ECG and Respiratory Signals Using Recurrent Neural Networks
PublicationThe estimation of systolic and diastolic blood pressure using artificial neural network is considered in the paper. The blood pressure values are estimated using pulse arrival time, and additionally RR intervals of ECG signal together with respiration signal. A single layer recurrent neural network with hyperbolic tangent activation function was used. The average blood pressure estimation error for the data obtained from 21 subjects...
-
The forming and emission of high power electromagnetic pulses
PublicationAn impulse energy source, a power conditioning system and an electromagnetic field emitter are essential to generate an electromagnetic field pulse (EMFP) with a specific frequency bandwidth. Selected simulation results for a power conditioning system consisting of a fuse opening switch and a paraboloidal electromagnetic emitter have been presented in this article. The synthetic system examined in the simulation is powered by...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Estimating Intercept Range of Silent Sonar
PublicationWhen used in military application, sonars should ensure secretiveness. There is some evidence suggesting that silent sonars have a significant advantage over pulse sonars in the respect. If improved, the secretiveness of silent sonar translates into the distance over witch its soundings signal are detected by intercept sonars. The article gives estimated distances for far, medium, and short range sonars operating in the oceans...
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
A concept of software extension of 3D low-PRF radar systems to 4D semi-medium-PRF radar systems
PublicationWe present a concept of software modification of three-dimensional (3D) radar systems, designed to work in the low pulse repetition frequency mode, that equips them with the ability to estimate the radial velocity and to properly measure the range of targets that are detected outside the radar’s instrumented range. Despite the fact that the proposed modifications are designed so as to require only minor changes in software, they...
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Evaluation of Facial Pulse Signals Using Deep Neural Net Models
PublicationThe reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Can we rely on the pulse transit time - pressure relationship - models comparison
PublicationAn unobtrusive, noninvasive and continuous pressure measurement is invaluable however, still being under research and development. There are many attempts proposing an appropriate relationship between pulse pressure velocity and pressure. Fifteen different formulas, both theoretical and experimental, describing relation between blood pressure and crosssectional area of the vessel were examined. Using these formulas the relation...
-
Remote Estimation of Video-Based Vital Signs in Emotion Invocation Studies
PublicationAbstract— The goal of this study is to examine the influence of various imitated and video invoked emotions on the vital signs (respiratory and pulse rates). We also perform an analysis of the possibility to extract signals from sequences acquired with cost-effective cameras. The preliminary results show that the respiratory rate allows for better separation of some emotions than the pulse rate, yet this relation highly depends...
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
Directed pulse dynamics
PublicationIntroducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.
-
Ultrashort Opposite Directed Pulses Dynamics with Kerr Effect and Polarization Account
PublicationWe present the application of projection operator methods to solving the problem of the propagation and interaction of short optical pulses of different polarizations and directions in a nonlinear dispersive medium. We restrict ourselves by the caseof one-dimensional theory, taking into account material dispersion and Kerr nonlinearity. The construction of operators is delivered in two variants: for the Cauchy problem and for the...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublicationIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Digital Processing of Frequency–Pulse Signal in Measurement System
PublicationThe work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...
-
Propagation of acoustic pulses in some fluids with yield stress
PublicationThis study is devoted to the derivation of approximate equations governing acoustic pulses in flows with yieldstress, including some time-dependent flows with a slow dependence on time of yield stress and apparent viscosity. Themodeling of yield stress and apparent viscosity in the vicinity of a zero deformation rate allows us to consider a thixotropicfluid as a Bingham plastic with coefficients that are dependent on time. The...
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublicationThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
Cross-talk Between the Heart and Arteries in Older 65+ Adults
PublicationRegulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...
-
Caffeine detection using CB-PLA electrode after Nd:YAG laser ablation in He atmosphere
Open Research DataThe dataset contains electrochemical studies in form of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) of laser-activated 3D printed CB-PLA electrodes. The ablation of the 3D-printed CB-PLA electrodes was carried out using a pulsed LaserBlast 500 Nd:YAG laser (Quantel, France) operating at 1064 nm and a 6 ns pulse duration.
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Control strategy for the multilevel cascaded H-bridge converter
PublicationThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
A new duty cycles calculation method in pulse width modulation for direct matrix converters based on the shape function concept
PublicationPaper presents a new approach to duty cycle calculation in pulse width modulation for direct matrix converters. The essence of the proposed method is the use of elementary shape function of finite element. The algorithm for calculating the duty cycles was reduced to simple operations on the coordinates of input and output voltage vectors without trigonometric functions.
-
Enhanced Remote Control Providing Medical Functionalities
PublicationThis paper presents the enhanced remote control and its role in pervasive healthcare in the home. The device was equipped with health-related measurement modules and a message-processing unit. Preliminary results are presented for monitoring of a pulse, hand tremors, grip forces, and for self evaluation procedures. The interaction of the device with the smart environment is presented and discussed.
-
Pulse-Width Modulation Template for Five-Level Switch-Clamped H-Bridge-Based Cascaded Multilevel Inverter
PublicationThis article presents a carrier-based pulse-width modulation (PWM) template for a 5-level, H bridge-based cascaded multilevel inverter (MLI). The developed control concept generates adequate modulation template for this inverter topology wherein a sinusoidal modulating waveform is modified to fit in a single triangular carrier signal range. With this modulation approach, classical multiplicity and synchronization of the triangular...
-
Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review
PublicationCoatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...
-
Studying the Effect of Working Conditions on WEDM Machining Performance of Super Alloy Inconel 617
PublicationWire electrical discharge machining (WEDM) has been for many years a precise and efficient non-conventional manufacturing solution in various industrial applications, mostly involving the use of hard-to machine materials like, among other, the Inconel super alloys. The focus of the present study is on exploring the effect of selected control parameters, including pulse duration, pulse-off time and the dielectric flow pressure on...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Radar time budget optimization subject to angle accuracy constraint via cognitive approach
PublicationThe problem of minimizing dwell time in multifunction phased array radar is considered. Target of interest is assumed to fluctuate according to a generalization of Swerling family and the parameters of fluctuation model are assumed to be known. The a'priori position of the target is uncertain. Optimization, whose variables include pulse count and array transmit beampattern, is carried out subject to achieving a desired accuracy...
-
Continuous blood pressure monitoring by photoplethysmography - signal preprocessing requirements based on blood flow modelling
PublicationObjective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPGfiducial...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowbandtransmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
Eksperymentalna analiza modalna stojanów silników indukcyjnych
PublicationW artykule zaprezentowano technikę pomiarów i wyniki obliczeń postaci drgań własnych badanego stojana silnika indukcyjnego klatkowego. Przedstawiono również teoretyczne podstawy zastosowanej techniki obliczeniowej. Jako narzędzie akwizycji danych wykorzystano pomiarowy system PULSE firmy Brüel&Kjær, a w celu przeprowadzenia koniecznych obliczeń oraz wizualizacji wyników wykorzystano środowisko Matlab.
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a UWB Signal
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. In the first part of paper, unmodified IEEE 802.15.4a IR UWB signal is used. Then some modification of transmitted pulse sequence is proposed, which allow to reduce UWB power spectral density at frequency of narrowband transmission. Finally narrowband transmission quality in presence of modified ultrawideband...
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublicationA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...