Filters
total: 867
-
Catalog
Search results for: CHIRAL MOLECULES CHIRALITY BIOSENSORS OPTICAL SENSOR ENANTIOMER ELECTROCHEMICAL SENSOR SENSOR
-
A Highly Sensitive Planar Microwave Sensor for Detecting Direction and Angle of Rotation
PublicationThis article presents a technique based on a modified complementary split-ring resonator (CSRR) to detect angular displacement and direction of rotation with high resolution and sensitivity over a wide dynamic range. The proposed microwave planar sensor takes advantage of the asymmetry of the sensor geometry and measures the angle of rotation in terms of the change in the relative phase of the reflection coefficients. The sensor...
-
The SARS‐CoV ‐2 specific IgG antibodies biophotonic sensor
PublicationIn this paper, we present the design and the principle of operation of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific immunoglobulin G (IgG) biophotonic sensor, which is based on the single-mode telecommunication fiber. We fabricated the sensor head at the face of the single mode fiber-28. Due to the process of bio-functionalization, our sensor has the ability to selectively detect the SARS-CoV-2 specific...
-
Development of beltless respiration and heartbeat sensor based on flexible piezoelectric film
PublicationThe main goal of this work is to report initial development on a respiration and heartbeat measurement sensor that can be used in continuous monitoring conditions at a minimal impact on the patient. General description of the sensor, consisting of a PVDF film and the bonding layer, is given. Open-circuit voltage generated by the sensor is estimated by analytical and numerical calculations. Analog and digital interface used to extract...
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Construction and investigation of SO2 amperometric sensor with a solid polymer electrolyte membrane
Publicationn this paper a sensor for detection of the sulphur dioxide based on three electrode cell configuration with a liquid electrolyte, a mercury sulphate reference electrode and a solid polymer electrolyte working electrode is presented. Working elec- trode was obtained by using Takenaka-Torikai chemical deposi- tion method by precipitation of Au particles into the pores of the Nafion membrane. Sensors characteristics measurements were...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
An optimized system for sensor ontology meta-matching using swarm intelligent algorithm
PublicationIt is beneficial to annotate sensor data with distinct sensor ontologies in order to facilitate interoperability among different sensor systems. However, for this interoperability to be possible, comparable sensor ontologies are required since it is essential to make meaningful links between relevant sensor data. Swarm Intelligent Algorithms (SIAs), namely the Beetle Swarm Optimisation Algorithm (BSO), present a possible answer...
-
Wavelet Transform Analysis of Temperature Modulated Gas Sensor Response
PublicationThe aim of the study was to evaluate whether it is possible to extract the information about the gas concentration despite the influence of humidity. Commercial semiconductor sensor response was examined under the application of a periodic temperature change. The data was collected using measurement protocol for different concentrations of ammonia at specified levels of relative humidity. In this work we focused on the evaluation...
-
The secure transmission protocol of sensor Ad Hoc network
PublicationThe paper presents a secure protocol of radio Ad Hoc sensor network. This network operates based on TDMA multiple access method. Transmission rate on the radio channel is 57.6 kbps. The paper presents the construction of frames, types of packets and procedures for the authentication, assignment of time slots available to the node, releasing assigned slots and slots assignment conflict detection.
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationScent or aroma sensing during aromatherapy can be carried out by applying only a single resistance gas sensor (TGS - Taguchi Gas Sensors). This paper considers the efficiency of detection of essential oils by DC resistance and its fluctuations observed in TGS sensors. A detailed study has been conducted for scents emitted by five popular essential oils using three sensor types (TGS 2600, TGS 2602, TGS 823). The research was focused...
-
Enhancing Performance of Switched Parasitic Antenna for Localization in Wireless Sensor Networks
PublicationThis paper presents an Electronically Steerable Parasitic Array Radiator (ESPAR) antenna with enhanced performance of estimating the incoming signal direction. Designed antenna is dedicated for 2.4 GHz ISM applications with emphasis on Wireless Sensor Networks (WSN). The limitations of the existing design approach are illustrated, as well as perspectives and challenges of the proposed solution in relation to the localization in...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Low-volume label-free SARS-CoV-2 detection with the microcavity-based optical fiber sensor
PublicationAccurate and fast detection of viruses is crucial for controlling outbreaks of many diseases; therefore, to date, numerous sensing systems for their detection have been studied. On top of the performance of these sensing systems, the availability of biorecognition elements specific to especially the new etiological agents is an additional fundamental challenge. Therefore, besides high sensitivity and selectivity, such advantages...
-
Planar Microwave Bragg Reflector Resonant Dielectric Sensor
PublicationIn this paper, a periodic structure is used to design a microwave Bragg reflector with the help of hexagonal lattice, which provides a 5 GHz wide stopband between the low-pass band with cut-off frequency 2.6 GHz and the bandpass response with start and stop frequency 7.8 GHz and 10.5 GHz, respectively. A defect in lattice allows passing a narrowband signal at 6 GHz which is found, from the dispersion relation, to be in the region...
-
A Compact and Lightweight Microwave Tilt Sensor Based on an SRR-Loaded Microstrip Line
PublicationIn this paper, the symmetry property of split ring resonators (SRRs) is exploited to develop a tilt sensor. The sensor is composed of an SRR-loaded microstrip line operating at microwave frequencies. It is shown that the depth of notch in the reflection characteristic of the microstrip is a function of the tilt angle of the SRR. Thus, it can be used for sensing inclination. The sensor benefits from very compact size and light weight....
-
New Manufacturing Method Of Sensor Oriented Optical Fibers
Publication -
Optical Diffraction Strain Sensor Prepared by Interference Lithography
Publication -
Wireless data transmission for fiber optical sensor system
PublicationW artykule opisano możliwość wykorzystania bezprzewodowego systemu transmisji danych do transmisji sygnałów z czujników światłowodowych.
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublicationMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublicationA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Determination of the Vehicles Speed Using Acoustic Vector Sensor
PublicationThe method for determining the speed of vehicles using acoustic vector sensor and sound intensity measurement technique was presented in the paper. First, the theoretical basis of the proposed method was explained. Next, the details of the developed algorithm of sound intensity processing both in time domain and in frequency domain were described. Optimization process of the method was also presented. Finally, the proposed measurement...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
IET Wireless Sensor Systems
Journals -
International Journal of Sensor Networks
Journals -
Journal of Sensors and Sensor Systems
Journals -
ACM Transactions on Sensor Networks
Journals -
Eventual Convergence of the Reputation-Based Algorithm in IoT Sensor Networks
PublicationUncertainty in dense heterogeneous IoT sensor networks can be decreased by applying reputation-inspired algorithms, such as the EWMA (Exponentially Weighted Moving Average) algorithm, which is widely used in social networks. Despite its popularity, the eventual convergence of this algorithm for the purpose of IoT networks has not been widely studied, and results of simulations are often taken in lieu of the more rigorous proof....
-
Investigation of Taste Substances by five Channel Lipid-Polymer Membrane Sensor.
PublicationBadano substancje o różnych stężeniach należące do czterech klas smaku za pomocą pięcio-kanałowego sensora opartego o elektrody jonoselektywne z różnymi membranami polimerowo-lipidowymi. Stwierdzono, że sensor jest czuły na zmiany stężeń chlorowodorku chininy, kawsu cytrynowego i chlorku sodu, przeciwnie jak w przypadku sacharozy. Na podstawie tych wyników można przypuszczać, że sensor może być zastosowany do roztworów składających...
-
Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement
PublicationDoppler sensors are commonly used for movement detection and speed measurement. However, electromagnetic interference and imperfections in sensor construction result in degradation of the signal to noise ratio. As a result, detection of signals reflected from moving objects becomes problematic. The paper proposes an algorithm for reduction of distortions and noise in the signal received from a simple, dual-channel type of a Doppler...
-
Localization in wireless sensor networks using switched parasitic antennas
PublicationA switched parasitic monopole antenna for 2.4 GHz ISM applications is design and investigated in this paper. One of the most promising applications for such switched-beam antennas is localization in wireless sensor networks (WSN). It is demonstrated that the use of this antenna improves accuracy of localization algorithms and allows for reduction of the number of reference nodes in localization system.
-
A Microwave Sensor with Operating Band Selection to Detect Rotation and Proximity in the Rapid Prototyping Industry
PublicationThis paper presents a novel sensor for detecting and measuring angular rotation and proximity, intended for rapid prototyping machines. The sensor is based on a complementary split-ring resonator (CSRR) driven by a conductor-backed coplanar waveguide. The sensor has a planar topology, which makes it simple and cost-effective to produce and accurate in measuring both physical quantities. The sensor has two components, a rotor, and...
-
Sandwich Biobattery with Enzymatic Cathode and Zinc Anode Integrated with Sensor
PublicationCarbon paper covered with side-naphthylated multi walled carbon nanotubes was used as the conducting support for the construction of a biocathode in a hybrid biofuel cell. Laccase Carrena unicolor enzyme was employed as the catalyst for the 4e reduction of oxygen and a zinc disc covered with hopeite was used as the anode. Derivatized carbon nanotubes increase the working surface of the electrode and provide direct contact with...
-
Sensor Letters
Journals -
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
Application of thin diamond films in low-coherence fiber-optic Fabry Pérot displacement sensor
PublicationThe novel fiber-optic low coherence sensor with thin diamond films is demonstrated. The undoped and boron-doped diamond films were elaborated by the use of the microwave plasma enhanced chemical vapor deposition (μPE CVD) system. The optical signal from the Fabry–Pérot cavity made with the application of those thin films is sensitive to displacement. The sensor characterization was made in the range of 0–600 μm. The measurements...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublicationThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Noise spectral density computation based on finite element model of piezoceramic sensor
PublicationThe high sensitivity with wide bandwidth is required for sensor applications in non-destructive testing (NDT). The sensitivity of piezoceramic sensors demands to minimize their noise especially thermal noise, polarisation noise and low frequency 1/f noise,which are the main sources of voltage or current fluctuation in this sort of sensors. For simplicity, only the piezoceramic part of sensor was under study. the theoretical and...
-
Sensor Position Estimation Method for IoT Using Mobile Reference Node
PublicationThe paper proposes an innovative method of locating objects for the Internet of Things (IoT). The proposed method allows the position of a fixed measuring sensor (MS) to be estimated using one mobile base station with a known position moving around the MS. The mathematical analysis of the method, and three algorithms — Newton’s (NA), gradient descent (GD) and genetic (GA) — for solving the system of non-linear positional equations...
-
Multi-functional sensor based on photonic crystal fiber using plasmonic material and magnetic fluid
PublicationA unique highly sensitive photonic crystal fiber is investigated based on plasmonic material and magnetic fluid (MF) for the simultaneous measurement of temperature and magnetic field sensor. The designed sensor is explored by tracing the different parameters such as birefringence, coupling length, power spectrum, and the peak wavelength of the transmission intensity. The magnetic field and temperature computation are attained...
-
Determination of vertical displacements by using the hydrostatic levelling systems with the variable location of the reference sensor,
PublicationAbstract: In this paper, the author proposed a new method for determination of vertical displacements with the use of hydrostatic levelling systems. The traditional method of hydrostatic levelling uses a rule in which a position of reference sensor is stable. This assumption was not adapted in the proposed method. Regarding the issue mentioned above, the reference sensor is treated in the same way as the others sensors that measure...
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublicationThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
Efficiency of linear and non-linear classifiers for gas identification from electrocatalytic gas sensor
PublicationElectrocatalytic gas sensors belong to the family of electrochemical solid state sensors. Their responses are acquired in the form of I-V plots as a result of application of cyclic voltammetry technique. In order to obtain information about the type of measured gas the multivariate data analysis and pattern classification techniques can be employed. However, there is a lack of information in literature about application of such...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublicationThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...
-
Photonic sensor to detect rapid changes in CRP levels
PublicationOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...