Search results for: GAS CHROMATOGRAPHY-OLFACTOMETRY
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part III. Diagnostic and operating tolerances
PublicationThe third part of the article presents a method for detecting failures of the automatic engine control system with the aid of an exhaust gas temperature setter, specially designed and machined for this purpose. It also presents a procedure of identifying the operating tolerances and determining the diagnostic tolerances for the exhaust gas temperature recorded in the naval turbine engine during the start-up and acceleration processes....
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part II. Unsteady processes
PublicationThe second part of the article presents the results of operating diagnostic tests of a two- and three-shaft engine with a separate power turbine during the start-up and acceleration of the rotor units. Attention was paid to key importance of the correctness of operation of the automatic engine load control system, the input for which, among other signals, is the rate of increase of the exhaust gas flow temperature. The article...
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 25-75wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 25/75 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Size Exclusion Coupled to Reversed Phase Liquid Chromatography for the Characterization of Cranberry Products
PublicationA combination of solvent extraction, size exclusion purification, and reversed-phase liquid chromatography with UV absorption and fluorescence detection was here used for the determination of flavan-3-ols and related oligomeric compounds in cranberry products. The method relied on robust, simple, and inexpensive instrumental equipment present in most of routine analytical laboratories. Sample extracts in methanol/water/hydrochloric...
-
A comparative study of pentanol (C5 alcohol) and kerosene blends in terms of gas turbine engine performance and exhaust gas emission
PublicationThe growing demand for sustainable and clean energy sources provides the incentive for the development of alternative fuels. Simultaneously, the development of gas turbine technologies with flexible fuel supply systems enables the use of alternative non-fossil fuels that can play key roles in contributing to global efforts in meeting emissions targets. This paper presents the current state of knowledge on the production and potential...
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-GDC
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-GDC (Gadolinia Doped Ceria 20mol.%Gd2O3) catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Analytical fluctuation enhanced sensing by resistive gas sensors
PublicationResistance fluctuations across polarised resistive gas sensors were studied in detail to evaluate sensor working conditions for detecting methane and ammonia at various concentrations. The 1/f noise component typically dominates other noise sources up to a few kHz and can be utilised to improve gas selectivity when compared with measurements of the sensor DC resistance. The Arrhenius plot was created and the activation energy for...
-
An electronic nose for quantitative determination of gas concentrations
PublicationThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
Novel Desorber for Online Drilling Mud Gas Logging
PublicationThis work presents the construction solution and experimental results of a novel desorber for online drilling mud gas logging. The traditional desorbers use mechanical mixing of the liquid to stimulate transfer of hydrocarbons to the gaseous phase that is further analyzed. The presented approach is based on transfer of hydrocarbons from the liquid to the gas bubbles flowing through it and further gas analysis. The desorber was...
-
Influence of operation temperature instability on gas sensor performance
PublicationGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublicationThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Liquid chromatography tandem mass spectrometry study of urinary nucleosides as potential cancer markers
Publication -
Suppression of deleterious effects of free silanols in liquid chromatography by imidazolium tetrafluoroborate ionic liquids
Publication -
Optimization of a Fabric Phase Sorptive Extraction protocol for the isolation of six bisphenols from juice pouches to be analysed by high performance liquid chromatography coupled with diode array detector
PublicationFabric Phase Sorptive Extraction (FPSE) combined with high pressure liquid chromatography using to diode array detection (HPLC-DAD) was applied for the simultaneous determination of bisphenols (BPA, BPB, BPC, BPE, BPF, BPS) in juice pouches. The FPSE procedure was optimized with regards to the critical parameters that affect the performance of the method including the selection of the FPSE membrane type and size, adsorption time,...
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Determination of Biogenic Amines in Wine Using Micellar Electrokinetic Chromatography
PublicationProduction on a large-scale of fermented alcoholic drinks made from different kinds of fruits is carried out in homes. Although wine laws regulating home production exist, they do not include upper concentration limits of biogenic amines. Therefore, a quick and inexpensive way to determine BAs in wine is crucial. A new analytical method based on micellar electrokinetic chromatography has been developed for the separation of the...
-
“Dilute & Shoot” approach for rapid determination of trace amounts of nicotine in zero-level e-liquids by reversed phase liquid chromatography and hydrophilic interactions liquid chromatography coupled with tandem mass spectrometry-electrospray ionization
Publication -
“Dilute & Shoot” approach for rapid determination of trace amounts of nicotine in zero-level e-liquids by reversed phase liquid chromatography and hydrophilic interactions liquid chromatography coupled with tandem mass spectrometry-electrospray ionization
PublicationTwo analytical procedures are proposed where HILIC and RPLC techniques are coupled with tandem mass spectrometry detection for rapid determination of trace amounts of nicotine in zero-level liquids for electronic cigarettes. Samples are prepared on the basis of the approach “dilute & shoot” which makes this important step quick and not complicated. The chromatographic separation was carried out on a Zorbax XDB column (RPLC method)...
-
Possibilities of Increasing the Overall Efficiency of Gas-steam CHP Microplant
PublicationThe paper presents ways to increase the efficiency of a gas-steam micro power plant by modifying the cycle combination. The modification consists in partial release of the fluid downstream of the gas turbine and using it for ORC fluid overheating and evaporation. Advantages of this solution over the simplest gas and steam cycles’ combination are demonstrated.
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublicationMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Carbon dioxide sequestration during shale gas recovery
PublicationThis paper presents literature on theoretical and practical aspects of gas production from shale using carbon dioxide fracturing. Development of technical and environmental aspects of carbon dioxide fracturing technologies is also considered. Patents applicable to carbon dioxide fracturing are reviewed. There were also conducted researches to evaluate possibility of carbon dioxide sequestration in shale gas reservoirs.
-
Security Assessment of a Turbo-Gas Power Plant
PublicationCritical infrastructures are exposed to new threats due to the large number of vulnerabilities and architectural weaknesses introduced by the extensive use of information and communication technologies. This paper presents the results of an exhaustive security assessment for a turbo-gas power plant.
-
Pharmaceutical and forensic drug applications of chiral supercritical fluid chromatography
PublicationTHE SUPERCRITICAL FLUID IS AN EXCELLENT CHOICE AS THE CHROMATOGRAPHIC MOBILE PHASE BECAUSE IT ALLOWS RAPID SEPARATION WITH HIGH EFFICIENCY AND APPLICATIONS INVOLVING ENANTIORESOLUTION ARE COMMON. SUPERCRITICAL FLUID CHROMATOGRAPHY (SFC) IS INCREASINGLY USED FOR ANALYTICAL, SEMI-PREPARATIVE AND PREPARATIVE PURIFICATION OF CHIRAL COMPOUNDS, INCLUDING PRODUCTION OF ENANTIOMERS THAT ARE MAINLY ENCOUNTERED DURING DRUG DEVELOPMENT. SFC...
-
Shooting Gas Cylinders to Prevent Their Explosion in Fire
PublicationGas cylinders in general, and particularly cylinders containing acetylene, constitute a great potential danger to fire and rescue services involved in salvage operations. Experiments show that gas cylinders with acetylene, oxygen, hydrogen, CNG, LPG or CO2 may blow after short exposition to heat with very destructive effect as fragments of blown cylinder may fly even several hundred meters. In the case of acetylene the explosion...
-
Gas sensors based on conducting polymers-recent developments
PublicationThis work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor....
-
New approaches for improving selectivity and sensitivity of resistive gas sensors: a review
PublicationPurpose – This paper aims to present the methods of improving selectivity and sensitivity of resistance gas sensors. Design/methodology/approach – This paper compares various methods of improving gas sensing by temperature modulation, UV irradiation or fluctuation-enhanced sensing. The authors analyze low-frequency resistance fluctuations in commercial Taguchi gas sensors and the recently developed tungsten trioxide (WO3) gas-sensing...
-
New approaches for improving selectivity and sensitivity of resistive gas sensors: A review
PublicationResistive gas sensors are very popular and reliable but suffer from low selectivity and sensitivity. Various methods have been suggested to improve both features without increasing the number of sensors in gas detection systems. Fluctuation enhanced gas sensing was proposed to improve gas detection efficiency by analyzing low-frequency resistance fluctuations, and noise parameters can be more informative than the single DC resistance...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
INTERNATIONAL GAS ENGINEERING AND MANAGEMENT
Journals -
Gas Wasserfach Wasser Abwasser
Journals -
Natural Gas Industry B
Journals -
OIL GAS-EUROPEAN MAGAZINE
Journals -
Journal of Natural Gas Chemistry
Journals -
Improved Oil and Gas Recovery
Journals -
Upstream Oil and Gas Technology
Journals -
Sensitive determination of isoprostanes in exhaled breath condensate samples with use of liquid chromatography-tandem mass spectrometry
PublicationOxidative stress is the hallmark of various inflammatory lung diseases. Increased concentrations of reactive oxygen species in the lungs are reflected by elevated concentrations of oxidative stress markers in the breath, airways, lung tissue and blood. The aim of this work was to develop a method for the fast measurement of F2 isoprostanes in exhaled breath condensate (EBC) samples using equipment which is nowadays available and...
-
Scalable Measurement System for Multiple Impedance Gas Sensors
PublicationAuthor proposes scalable architecture of the measurement system for gas sensor with impedance dependance of the gas concentration. The main part of the system is a single-board impedance analyser. The number of analysers working in parallel can be configured according to specific application. The system is controlled by a single computer which organises the measurement cycle and store the acquired measurement data. The system is...
-
Gas turbines – technological development and potential use in CAES systems
PublicationThis article briefly describes Compressed Air Energy Storage (CAES), focusing on the technological development of one of the key elements of such systems – the gas turbines. It presents the basic parameters and features of gas turbines, as well as turbine classes with example models. Main tendencies in the structural and technological development are discussed. Changes and trends on electric energy markets are becoming more and...
-
Lipophilicity data for some preservatives estimated by reversed-phase liquid chromatography and different copmutation methods
PublicationW pracy przedstawiono wyniki badań właściwości chromatograficznych wybranych 12 związków z grupy kopnserwantów. Lipofilowy charakter tych związków był oceniany na podtsawie różnych parametrów retencyjnych (log Kw, log K i inne. Zastosowano narzędzie chemometryczne do zbadania korelacji występujących pomiędzy tymi parametrami retencji chromatogfraficznej.
-
The application of gradient reversed-phase high-performance liquid chromatography to the pKa and determination of polyprotic analytes
Publication -
Inorganic membrane: a game changer for gas separation and purification
PublicationThis review explores the advancements and remaining challenges in inorganic membrane science, particularly focusing on their potential for industrial applications. It delves into the fundamental principles of inorganic membrane design, fabrication, and characterization techniques. The review also critically analyzes key challenges faced by inorganic membranes, such as physical aging, plasticization, defective formation, and fouling....
-
Noise related to gas bottles explosions
PublicationModern industrialized world is in a never ending danger of accidents and catastrophes of technical nature. Some of them may involve fires and explosions of gas storage bottles or containers. Technical University of Gdansk, Poland performed numerous tests where bottles containing acetylene, oxygen, hydrogen, CO2, LPG, LNG or CNG were blown due to excessive temperature caused by fire. Although those experiments were not focused on...
-
Preparation and evaluation of 1,3-alternate 25,27-bis-(pentafluorobenzyloxy)-26,28-bis-(3-propyloxy)-calix[4]arene-bonded silics gel high performance liquid chromatography stationary phase
PublicationA 1,3-alternate 25,27-bis-(pentafluorobenzyloxy)-26,28-bis-(3-propyloxy)-calix[4]arene-bonded silica gel stationary phase (CalixBzF10) was synthesized, structurally characterized, and used as a selector in liquid chromatography. The selectivity study of this phase was done by using fluorine-containing compounds (fluorobenzenes, fluoro-pyrimidine bases), as well as non-fluorinated analytes (non-steroidal anti-inflammatory drugs,...
-
Embedded gas sensing setup for air samples analysis
PublicationThis paper describes a measurement setup (eNose) designed to analyze air samples containing various volatile organic compounds (VOCs). The setup utilizes a set of resistive gas sensors of divergent gas selectivity and sensitivity. Some of the applied sensors are commercially available and were proposed recently to reduce their consumed energy. The sensors detect various VOCs at sensitivities determined by metal oxide sensors’ technology...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Application of ion chromatography with pulsed amperometric detection for the determination of trace cyanide in biological samples, including breast milk
PublicationCyanide (CN) is the biomarker of exposure to the components of tobacco smoke, although its presence in biological samples is also due to the consumption of products containing cyanogenic glycosides. In this work, we determine the concentration of the free cyanide in urine, saliva and breast milk matrices, using ion chromatography with pulsed amperometric detection (IC-PAD). IC-PAD is an emerging method, with only few documented...
-
Nonlinear Influence of Sound on the Vibrational Energy of Molecules in a Relaxing Gas
PublicationDynamics of a weakly nonlinear and weakly dispersive flow of a gas where molecular vibrational relaxation takes place is studied. Variations in the vibrational energy in the field of intense sound is considered. These variations are caused by a nonlinear transfer of the acoustic energy into energy of vibrational degrees of freedom in a relaxing gas. The final dynamic equation which describes this is instantaneous, it includes a...