displaying 1000 best results Help
Search results for: DUAL FREQUENCY ULTRASOUND METHOD
-
Impedance matching in dual-frequency induction heating systems
Publication -
A spice equivalent circuit for modeling the performance of dual frequency echo-sounder
PublicationThe paper presents novel network equivalent circuit of piezoceramic circular disc transducers that takes into account thickness and radial mode of vibrations. The starting point of the analysis is 4-port description of circular disc element representing the solution of wave equation set in radial and thickness directions. The approximate solution for harmonic case is represented in the form of 4x4 matrix, which is synthesised and...
-
Dual-Frequency Induction Heating Generator With Adjustable Impedance Matching
Publication -
Energy-Saving Inertial Drive for Dual-Frequency Excitation of Vibrating Machines
Publication -
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
PublicationThe article presents a three-phase Medium Frequency Transformer being a part of a 100kW 1.2kV 20kHz Dual Active Bridge DC-DC converter. The transformer design is detailed focusing on winding and core power loss calculation. The high power three-phase MFT prototype is presented. The experimental results include the transformer impedance characteristics, no load test and three-phase DAB full load test waveforms
-
Characterization of Corrosion-Induced Fracture in Reinforced Concrete Beams Using Electrical Potential, Ultrasound and Low-Frequency Vibration
PublicationThe paper deals with the non-destructive experimental testing of the reinforced concrete beams under progressive corrosion. A series of experiments using electrical potential, ultrasound and low-frequency vibrations techniques are reported. Electrical potential and natural frequencies were used to characterise and monitor the corrosion process at its initial state. The P-wave velocity measurements were proved to be effective in...
-
Fast bubble dynamics and sizing
PublicationSingle bubble sizing is usually performed by measuring the resonant bubble response using the Dual Frequency Ultrasound Method. However, in practice, the use of millisecond-duration chirp-like waves yields nonlinear distortions of the bubble oscillations. In comparison with the resonant curve obtained under harmonic excitation, it was observed that the bubble dynamic response shifted by up to 20 percent of the resonant frequency...
-
Highly-Compact Dual-Band Bandpass Waveguide Filter Based on Cross-Shaped Frequency-Dependent Coupling
PublicationThis work reports the design of an original class of highly-compact dual-band bandpass filter based on dual-mode waveguide resonators inter-coupled through a novel type of frequency-dependent coupling (FDC). The devised FDC consists of a cross-shaped metallic structure placed in the broad wall of a rectangular waveguide. This FDC produces two additional poles and three extra transmission zeros (TZs). Specifically, each pole is...
-
Effect of mid-frequency discharge assistance on dual-high power impulse magnetron sputtering
Publication -
3-phase medium frequency transformer for a 100kW 1.2kV 20kHz Dual Active Bridge converter
Publication -
A LUMPED-CIRCUIT MODEL OF CIRCULAR PISTON TRANSDUCER FOR MODELING ITS PERFORMANCE IN DUAL FREQUENCY OPERATING MODES
PublicationThe paper presents novel network equivalent circuit of piezoceramic circular disc transducer that takes into account thickness and ra dial mode of vibrations. The starting point of the analysis is 4-port description of circular disc element representing the solution of wave equation set in radial and thickness directions. Th e approximate solution for harmonic case is represented in the form of 4x4 matrix, which is syn thesized...
-
Modelowanie liczby i wielkości uszkodzeń drogowych barier ochronnych na odcinkach dróg
PublicationW ramach rozprawy doktorskiej podjęto problem funkcjonowania barier ochronnych, ze szczególnym uwzględnieniem częstości występowania oraz wielkości uszkodzeń barier na odcinkach dróg krajowych w Polsce. Rozpoznanie tematyki funkcjonowania barier ochronnych przy drogach, oraz identyfikacja nierozwiązanych problemów, pozwoliły na sformułowanie głównego celu pracy i celów szczegółowych. Cele te obejmują opracowanie i wdrożenie do...
-
Adenoid cystic carcinoma - Male, 67 - Tissue image [6280729578145851]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenoid cystic carcinoma - Male, 67 - Tissue image [6280729578148561]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Adenoid cystic carcinoma - Male, 67 - Tissue image [6280729578142041]
Open Research DataThis is the histopathological image of BREAST tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Przegląd systemów ładowania elektrycznych osobowych pojazdów i koncepcja dwukierunkowej ładowarki pokładowej
PublicationAktualnie trwa intensywny rozwój pojazdów elektrycznych (EV) i hybrydowych typu plug-in (PHEV) z pokładowymi bateriami akumulatorów. Badania w tej dziedzinie skupiają się na maksymalizowaniu sprawności oraz minimalizowaniu masy i objętości systemów ładowania baterii. W artykule przedstawiono podział systemów ładowania osobowych pojazdów typu EV/PHEV. Opisano systemy ładowania przewodowego z podziałem na ładowarki pokładowe i zewnętrzne, systemy...
-
Ni-based compounds in multiwalled graphitic shell for electrocatalytic oxygen evolution reactions
Open Research DataThis study investigates Ni-based compounds (Ni, NiO, Ni3C) coated with a graphitic shell as electrocatalysts for the oxygen evolution reaction (OER). Electron paramagnetic resonance (EPR) and X-ray diffraction (XRD) are employed to identify the presence and contribution of Nickel ions (Ni0, Ni2+, Ni3+) and determine the phase composition. Electrochemical...
-
Soft – Partial Frequency Reuse Method for LTE-A
PublicationIn the paper a novel SPFR frequency reuse method is proposed which can be used for improvement of physical resources utilization efficiency in LTE-A. The proposed method combines both SFR and PFR giving the possibility of more flexible use of frequency band in different regions of a cell. First, a short study on the problem of frequency reuse in cells is discussed including bibliography overview....
-
The luminescence study of Sr2−xSrxPN3:Eu2+ nitridophosphate.
Open Research DataIn this work, a series of Ca2−xSrxPN3:Eu2+ nitridophosphate phosphors through a solid-solution strategy involving a hot isostatic press was developed by collaborators from National Taiwan University. Unexpected dual emissions in the red and infrared regions are observed, different from previous research results. The unique change in red and near-infrared...
-
Implementation of an Adaptive Method for Changing the Frequency Division of the Counter Clock Signal in a Frequency-to-Code Converter
PublicationProcessing physical quantities into an indirect signal is a standard method of transferring information about the measured quantity to the master system, which analyzes the data obtained from the acquisition system. The intermediate signal is very often the voltage, but another transmission medium can be the frequency of the output signal of the “physical quantity-to-frequency” converter. The article presents the implementation...
-
A novel method of time-frequency analysis: an essential spectrogram
PublicationA novel precise method of time-frequency analysis is presented. In the algorithm, a new energy distribution is estimated by simultaneously discard or displacement of the classical spec- trogram energy. A channelized instantaneous frequency and a local group delay are used in order to replacement in the same manner as formulated by Kodera et al. [1, 2]. Additionally, new representations: a channelized instantaneous bandwidth and...
-
Malignant neoplasm of prostate - Male, 61 - Tissue image [1140629585379051]
Open Research DataThis is the histopathological image of PROSTATE GLAND tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Measurements of ultrasonic bulk and guided wave propagation in additively manufactured cubes and plates obtained by ultrasonic pulse velocity analyzer and scanning laser vibrometry
Open Research DataThe DataSet contains the results of measurements of ultrasonic wave propagation in additively manufactured samples made of polylactic acid (PLA). Three types of raster angles in two consecutive layers were assumed: 0°/90° (#1), 45°/-45° (#2) and 90°/90° (#3) with respect to the x-axis. For each printing variants a cubic sample (#C1-3) with dimensions...
-
Improvement of Fingerprinting Method based on Hill Cipher by using Frequency Domain
PublicationThe main goal of this paper is to present the advantages of a digital fingerprinting in a frequency domain over a pixel domain, in case of VoD services (Video on Demand). The paper presents basic issues of a multimedia data protection by digital fingerprinting. It also describes threats to embedded fingerprints from both collusion attacks and from a transmission itself. Possible solution was presented on the example of the DCT...
-
A Compact Basis for Reliable Fast Frequency Sweep via the Reduced-Basis Method
PublicationA reliable reduced-order model (ROM) for fast frequency sweep in time-harmonic Maxwell’s equations by means of the reduced-basis method is detailed. Taking frequency as a parameter, the electromagnetic field in microwave circuits does not arbitrarily vary as frequency changes, but evolves on a very low-dimensional manifold. Approximating this low-dimensional manifold by a low dimension subspace, namely, reduced-basis space, gives...
-
Tinnitus diagnosis and therapy method employing ultrasound dithering.
PublicationZaproponowano interpretację sposobu powstawania szumów usznych w oparciu o teorię kwantyzacji sygnału. Przedstawiono stan prac nad urządzeniem ultradźwiękowym do maskowania szumów usznych, opartym na tej teorii.
-
A method for the estimation of dual transmissivities from slug tests
Publication -
A new time-frequency detection method of stray current field interferenceon metal structures.
PublicationA new detection method has been presented of stray current field interference on underground metal structures. The method employs short time Fourier transformation (STFT). This method of analysis allows determination of signal spectral power density changes (e.g., structure potential) in the function of time. In the paper results have been presented of total time–frequency analysis of a pipeline potential in a stray current field...
-
Novel Interpolation Method of Multi-DFT-Bins for Frequency Estimation of Signal with Parameter Step Change
PublicationThe IpDFT(Interpolation Discrete Fourier Trans-form) method is one of the most commonly used non-parametric methods. However, when a parameter (frequency, amplitude or phase) step changes in the DFT period, the DFT coefficients will be distorted seriously, resulting in the large estimation error of the IpDFT method. Hence, it is a key challenge to find an IpDFT method, which not only can eliminate the effect of the step-changed...
-
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publication -
Continuous frequency method of measurement of electrode impedance.
PublicationPrzedstawione zostały matematyczne podstawy nowej metody pomiaru impedancji elektrodowej. Metoda wykorzystuje sygnał pobudzenia którego częstotliwość zmienia się liniowo w czasie. Amplituda sinusoidalnego niestacjonarnego pobudzenia jest stała. Zapis i analiza sygnału pobudzenia i odpowiedzi pozwalana wyznaczenie ciągłego widma impedancyjnego. Jednoczesna analiza czasowo częstotliwościowa wykonano została przy użyciu transformacji...
-
Preparation of MnCo2O4 and Mn1.7CuFe0.3O4 single-layer, and novel MnCo2O4/ Mn1.7CuFe0.3O4 dual-layer spinel protective coatings on complex-shaped metallic interconnects by EPD method
PublicationCeramic protective coatings applied to metallic interconnects play a vital role in solid oxide cells (SOCs) preventing interconnect degradation. In this study, uniform, dense, and crack-free single-layer coatings of MnCo2O4, Mn1.7CuFe0.3O4, and dual-layer coatings of MnCo2O4/ Mn1.7CuFe0.3O4 spinel are deposited onto complex-shaped metallic interconnect using electrophoretic deposition (EPD) method. The porosity of sintered MnCo2O4...
-
Natural deep eutectic solvent based ultrasound assisted liquid-liquid micro-extraction method for methyl violet dye determination in contaminated river water
PublicationSimple and green natural deep eutectic solvent (NADES) based ultrasound assisted liquid-liquid micro-extraction (UA-LLME) method was developed for extraction and determination of methyl violet dye in contaminated river water samples using UV/Vis spectrophotometry. Choline chloride - decanoic acid based natural deep eutectic solvent was used for extraction. Important analytical parameters like pH, deep eutectic solvent volume/phase...
-
Method of sacrificial anode dual transistor-driving in stray current field
PublicationIn order to control a magnesium anode in a stray current interference field, a dual transistor driving system has been proposed. It consisted of a combination of PNP and NPN transistors. Dual transistor driven system and direct anode to cathode connection were electrochemically tested in 3% NaCl solution. The dual transistor driven system increased the anode efficiency and reduced hydrogen evolution and the risk of embrittlement....
-
High frequency dynamics of an isotropic Timoshenko periodic beam by the use of the Time-domain Spectral Finite Element Method
PublicationIn this work results of numerical simulations and experimental measurements related to the high frequency dynamics of an aluminium Timoshenko periodic beam are presented. It was assumed by the authors that the source of beam structural periodicity comes from periodical alterations to its geometry due to the presence of appropriately arranged drill-holes. As a consequence of these alterations dynamic characteristics of the beam...
-
Single and Dual-GPU Generalized Sparse Eigenvalue Solvers for Finding a Few Low-Order Resonances of a Microwave Cavity Using the Finite-Element Method
PublicationThis paper presents two fast generalized eigenvalue solvers for sparse symmetric matrices that arise when electromagnetic cavity resonances are investigated using the higher-order finite element method (FEM). To find a few loworder resonances, the locally optimal block preconditioned conjugate gradient (LOBPCG) algorithm with null-space deflation is applied. The computations are expedited by using one or two graphical processing...
-
Terrestrial Survey Images - Multispectral Exterior Model - Gdansk Church Pw. Św. Wojciecha - Micasense Dual
Open Research DataDataset description: Raw images from photogrammetric survey. Object: Kościół Rzymskokatolicki Pw. Św. WojciechaLocation: Gdansk, Pomerania, PolandDrone type: N/A (terrestrial images)Flight plan: Free - walk around the object with camera. 3 images taken at the point.Target Product: 3D Model - Multispectral ModelDate: 24.04.2022Direct georeferencing:...
-
Spinel-Type Structured Phosphor Near-Infrared-II Emission: Intervalence Charge Transfer and Hetero-Valent Chromium Pairs
Open Research DataNear-infrared (NIR) emitting phosphors draw much attention because they show great applicability and development prospects in many fields. Herein, a series of inverse spinel-type structured LiGa5O8 phosphors with a high concentration of Cr3+ activators is reported with a dual emission band covering NIR-I and II regions. Except for strong ionic exchange...
-
A time-frequency method for detection of electromagnetic field interference on metal constructions.
PublicationPrzedstawiono metodę detekcji oddziaływania pola elektromagnetycznego na metalowe konstrukcje podziemne. Polega ona na czasowo-częstotliwościowej analizie rejestrów zmian potencjału źródła pola (np. prądów błądzących) oraz potencjału konstrukcji podziemnej, z wykorzystaniem krótkoczasowej transformaty Fouriera STFT. Wnioski o oddziaływaniu pola na konstrukcję metalową wyciąga się na podstawie analizy uzyskanych widm.
-
Study of the optical rotatory of potassium titanyl phosphate using the advanced dual-wavelength polarimetric method
PublicationA dual-wavelength high-accuracy universal polarimeter was applied to the circular birefringence and optical activity measurement in potassium titanyl phosphate (KTP) nonlinear crystal. The experimental setup used two single-mode He-Ne lasers with close wavelengths of 594 and 633 nm as light sources. Measurement has been carried out for two crystal settings in directions of a 45-degree relative angle to the [100] and [010] crystallographic...
-
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Application of the Least Squares Method to the approximation of equally spaced samples in frequency measurement approach
Publication -
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publication -
A novel method of local chirp-rate estimation of LFM chirp signals in the time-frequency domain
PublicationIn the paper, novel dynamic representations of a complex signal in the time-frequency domain are introduced. The proposed approach is based on using the gradient of the short-time Fourier transform complex phase. A channelized instantaneous complex frequency (CICF) and a complex local group delay (CLGD) are included in the presented signal representations. An application of the newly-introduced distributions is demonstrated by...
-
RSS-Based DoA Estimation in 802.11p Frequency Band Using ESPAR Antenna and PPCC-MCP Method
PublicationIn this paper, the concept of direction of arrival (DoA) estimation using electronically steerable parasitic array radiator (ESPAR) antenna designed to operate in IEEE 802.11p vehicular communication standard has been investigated with respect to different possible elevation angles of a radio frequency (RF) signal impinging the antenna. To this end, two different possible sets of the 3D antenna radiation patterns have been used...
-
Nonlinear impedance as a function of frequency for Bi2VO5.5 ceramic of thickness 2.88 mm was measured at high temperature range with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Power grid frequency measurement in LabVIEW environment using the least mean squares method to signal phase approximation in the presence of noise
Publication -
Nonlinear impedance as a function of temperature and frequency for Bi2VO5.5 ceramic of thickness 2.52 mm was measured at different A.C. voltage with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
Differential Quadrature Method for Dynamic Buckling of Graphene Sheet Coupled by a Viscoelastic Medium Using Neperian Frequency Based on Nonlocal Elasticity Theory
PublicationIn the present study, the dynamic buckling of the graphene sheet coupled by a viscoelastic matrix was studied. In light of the simplicity of Eringen's non-local continuum theory to considering the nanoscale influences, this theory was employed. Equations of motion and boundary conditions were obtained using Mindlin plate theory by taking nonlinear strains of von Kármán and Hamilton's principle into account. On the other hand, a...