displaying 1000 best results Help
Search results for: IMPERFECT PULSE METHOD
-
Digital mono-pulse method in cylindrical antena.
PublicationArtykuł prezentuje metodę poprawy dokładności namiaru w wielowiązkowym sonarze z anteną cylindryczną. Metoda oparta jest na metodzie monopulsowej, wykorzystywanej w radarach i sonarach. Metoda zapewnia dobrą dokładność namiaru dla pojedynczego impulsu sondującego. Jedyna modyfikacja w stosunku do metody oryginalnej polega na wytworzeniu dwóch odchylonych wiązek i wykonaniu prostych obliczeń. Symulacja komputerowa dowodzi , że uzyskanie...
-
Directed electromagnetic pulse dynamics: projecting operators method
PublicationIn this article, we consider a one-dimensional model of electromagnetic pulse propagation in isotropic media, takinginto account a nonlinearity of the third order. We introduce a method for Maxwell's equation transformation on thebasis of a complete set of projecting operators. The operators correspond to wave dispersion branches including thedirection of propagation. As the simplest result of applying the method, we derive a system...
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublicationIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
Method using square-pulse excitation for high-impedance spectroscopy of anticorrosion coatings
PublicationArtykuł prezentuje metodę spektroskopii impedancyjnej przeznaczonej do diagnostyki powłok antykorozyjnych na obiektach bezpośrednio w terenie. Aby skrócić czas uzyskania widma impedancji (w zakresie od 1 mHz do 1 MHz) do kilku minut, wykorzystano sygnały harmoniczne do pomiaru widma powyżej 10 Hz a impuls prostokątny w dolnym zakresie częstotliwości. Do wyznaczania widma użyto algorytmów DSP odpowiednich do sygnału pobudzenia....
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publication -
A new duty cycles calculation method in pulse width modulation for direct matrix converters based on the shape function concept
PublicationPaper presents a new approach to duty cycle calculation in pulse width modulation for direct matrix converters. The essence of the proposed method is the use of elementary shape function of finite element. The algorithm for calculating the duty cycles was reduced to simple operations on the coordinates of input and output voltage vectors without trigonometric functions.
-
Impedance spectra of RC model as a result of testing pulse excitation measurement method
Open Research DataThe impedance spectrum of RC model object obtained using pulse excitation EIS impedance spectrosocpy measurement method. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. The object under test was built using RC components connected as Baunier model of anticorrosion coating with the following components...
-
Rheological and compressive strength (ultrasonic pulse method) properties of cement pastes containing iron oxide (Fe3O4) nanoparticles
Open Research DataRheological data of cement pastes containing different replacement levels of cement with iron oxide nanoparticles deterimined using MCR 301 (Anton Paar) stress-imposed rheometer, equipped with calibrated helicoidal geometry
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Jacek Stefański prof. dr hab. inż.
PeopleJJacek Stefański received M.Sc., Ph.D. and D.Sc. degrees in telecommunications engineering from Gdansk University of Technology (GUT), Poland, in 1993, 2000 and 2012, respectively. Awarded title of Professor by the President of Poland in 2020. Currently, he works as a professor at the Department of Radio Communication Systems and Networks (DRCSN) in GUT. From 2005 to 2009, he worked as an assistant professor in the National Institute...
-
Zastosowanie wyłącznika bezpiecznikowego do formowania impulsu wielkiej mocy
PublicationW wielu układach fizycznych i technicznych konieczne jest wytwarzanie impulsów wielkiej mocy o krótkim czasie trwania (rzędu ułamków µs). Impulsy te uzyskuje się stosując układy formujące zasilane ze źródła impulsowego wielkiej mocy, o długim czasie trwania impulsu, rzędu kilkudziesięciu µs. Jednym z układów formujących jest bezpiecznik wyłącznikowy. W pracy metodą symulacyjną badano wpływ parametrów bezpiecznika wyłącznikowego...
-
Samotestowanie toru analogowego ze wzmacniaczem w pełni różnicowym w elektronicznych systemach wbudowanych sterowanych mikrokontrole-rami
PublicationPrzedstawiono nową metodę samotestowania toru analogowego opartego na wzmacniaczu w pełni różnicowym w elektronicznych systemach wbu-dowanych sterowanych mikrokontrolerami. Bazuje ona na nowej metodzie diagnostycznej opartej na przekształceniu transformującym próbki odpo-wiedzi czasowej badanej części analogowej na pobudzenie "ujemnym" impulsem prostokątnym na wejściu Vocm na krzywe identyfikacyjne w przestrzeni pomiarowej. Metoda...
-
Improvement of Imperfect String Matching Based on Asymetric n-Grams
PublicationTypical approaches to string comparing treats them as either different or identical without taking into account the possibility of misspelling of the word. In this article we present an approach we used for improvement of imperfect string matching that allows one to reconstruct potential string distortions. The proposed method increases the quality of imperfect string matching, allowing the lookup of misspelled words without significant...
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublicationIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Directed pulse dynamics
PublicationIntroducing a projection method into a one-dimensional model of a pulse propagation in isotropic media, we derive and investigate a system of equation describing dynamics ultrashort pulses of opposite directions ofpropagation and ones with interaction of directed pulses with different polarization.
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Diagnostyka analogowych filtrów wielosekcyjnych oparta na magistrali testującej IEEE1149.1
PublicationPrzedstawiono nową koncepcję testera JTAG BIST do samo-testowania torów analogowych opartych na wielosekcyjnych filtrach wyższego rzędu w mieszanych sygnałowo mikrosystemach elektronicznych sterowanych mikrokontrolerami i wyposażonych w magistralę testującą IEEE1149.1 (JTAG). Bazuje ona na metodzie diagnostycznej opartej na przekształce-niu transformującym próbki odpowiedzi czasowych kolejnych sekcji filtra pobudzonego impulsem...
-
Measuring Pulse Rate with a Webcam
PublicationIn this paper a simple method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face images captured from a webcam. The desired signal is obtained by proper channel selection and principal component analysis. To determine the accuracy of the method an ECG signal is collected together with a video recordings. The effectiveness of the algorithm is considered...
-
Semantic segmentation training using imperfect annotations and loss masking
PublicationOne of the most significant factors affecting supervised neural network training is the precision of the annotations. Also, in a case of expert group, the problem of inconsistent data annotations is an integral part of real-world supervised learning processes, well-known to researchers. One practical example is a weak ground truth delineation for medical image segmentation. In this paper, we have developed a new method of accurate...
-
Photogrammetry image-based approach for imperfect structure modelling and FE analysis
PublicationThis study aims to model and analyse imperfect tructures using real measurements, employing photogrammetry technique commonly used in the geodesy. The study highlights the capability of the photogrammetry in aiding the structural analysis of imperfect engineering objects. Firstly, the photogrammetry measurements of a stiffened plate are carried out using a specially designed for the purpose experimental stand. Then, the plate surface...
-
Application of algorithms for reasoning from imperfect knowledge in it evaluation environment
PublicationThe paper describes concept of building multi-agent system dedicated for information technology evaluation or selection for IT enterprises management (IT_MAS). Authors present the model of Knowledge Processing Environment, which is one of main components of the solution. Either facts or rules will be based on IT specialists' experience. However, knowledge which is being acquisited from IT domain is mostly imperfect - uncertain...
-
Transient modeling in common DC link of power converters
PublicationПредмет исследования. Представлена математическая модель силовых преобразователей электропривода, питающихся от общего звена постоянного тока, на примере тяговых электроприводов карьерного самосвала БЕЛАЗ-90 мощностью 280 кВт. Модель выполнена в пакете MATLAB/Simulink. Новизна предложенной модели заключается в применении новой топологии силовой схемы для исследования работы двух инверторов, под- ключенных к одному звену постоянного...
-
Influence of preprocessing techniques on pulse pressure velocity determination
PublicationPulse Wave Velocity (PWV) is measured and utilized in many clinical applications. Recently, a wide research has been led to develop a cuff-less and continuous blood pressure method basing on PWV. However, in this application a decision on choosing an appropriate fiducial point of pulse wave (PW) waveform is necessary and substantial. It would allow to measure time parameters necessary to determine PWV. An influence of sampling...
-
IEEE Pulse
Journals -
Stability of an imperfect truss loaded by wind
PublicationThe present paper is devoted to the numerical research of stability of a truss loaded by wind and stiffened by elastic supports located at the top chord. The lateral braces or lateral and torsional braces were taken into account. In this paper, the linear buckling analysis re- sults for the beam and shell model were presented. Two different shapes of initial geometric imperfections were considered in the non-linear static analysis...
-
Experimental and numerical investigations of ultimate strength of imperfect stiffened plates of different slenderness
PublicationThe objective of this study is to analyse the behaviour of compressed stiffened plates of different slenderness using experimental and numerical methods. The presented results are part of a long-term project to investigate the ultimate strength of geometrically imperfect structures subjected to different degradation phenomena, including corrosion degradation and locked cracks. Several specimens were subjected to a uniaxial compressive...
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublicationThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
Finite Element Method
e-Learning CoursesItem Name : Finite Element Method- Abaqus learning Field of study : Civil Engineering Faculty : Faculty of Civil and Environmental Engineering Education level : Second degree studies Form of studies : Full-time studies Year of studies : 1 Study semester : 2 Start of the semester : November 2021 Academic year of the course : 2021/2022 Form of classes : Lecture, Laboratory
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Digital Processing of Frequency–Pulse Signal in Measurement System
PublicationThe work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...
-
Energy Losses Due to Imperfect Payment Infrastructure and Payment Instruments
PublicationOne of the strategic objectives of the European Union is a reduction in greenhouse gas emissions and improvement of energy efficiency by at least 32.5% in different areas of the economy by 2030. However, little is known about the impact of payment in retail on energy consumption. The purpose of this paper is to assess the chain of losses of time and energy, and therefore financial losses, that occur due to the imperfection of payment...
-
Sonar Pulse Detection Using Chirp Rate Estimation and CFAR Algorithms
PublicationThis paper presents a new approach to sonar pulse detection. The method uses chirp rate estimators and algorithms for the adaptive threshold, commonly used in radiolocation. The proposed approach allows detection of pulses of unknown parameters, which may be used in passive hydrolocation or jamming detection in underwater communication. Such an analysis is possible thanks to a new kind of imaging, which presents signal energy in...
-
Reliability of imperfect structures (simple non-linear models)
PublicationPrzyjęto proste modele prętów umożliwiających analizę układów o niestatecznych i statecznych punktach bifurkacji. Wykorzystano symulacyjną metodę wyznaczania niezawodności. Zastosowano metodę Monte Carlo i równania 3 poziomu dokładności. Uzyskano rozkłady prawdopodobieństwa obciążenia granicznego nieliniowych modeli konstrukcji z losowymi imperfekcjami. Wykazano, że histogramy siły granicznej modelu statecznego i niestatecznego...
-
Buckling of imperfect silo shells containing bulk solids.
PublicationOmówiono problem wyboczenia stalowych silosów wypełnionych materiałem sypkim. Obliczenia wykonano dla płaskiego stanu odkształcenia i dla osiowo-symetrycznego. Zachowanie materiału sypkiego było modelowane mikropolarnym hypoplastycznym prawem materiałowym, a zachowanie ścian silosu mikropolarnym sprężysto-plastycznym prawe wg von Misesa. W obliczeniach uwzględniono różne imperfekcje na ścianach.
-
Finite Element Method Applications - winter 2022/2023
e-Learning CoursesFinite Element Method Applications - summer 2022/2023 Seminar.
-
Finite Element Method Applications - winter 2023/2024
e-Learning CoursesFinite Element Method Applications - winter 2022/2023 Seminar.
-
Finite Element Method Applications - summer 2022/2023
e-Learning CoursesFinite Element Method Applications - summer 2022/2023 Seminar.
-
Finite Element Method Applications 2023/2024 Summer
e-Learning CoursesFinite Element Method Applications - summer semester 2023/2024 Seminar.
-
Finite Element Method Applications 2024/2025 winter
e-Learning CoursesFinite Element Method Applications - winter semester 2024/2025 Seminar.
-
New Architecture of Solid-State High-Voltage Pulse Generators
PublicationThe application of the nanosecond pulsed electric field (nsPEF) for biomedical treatments has gained more interest in recent decades due to the development of pulsed power technologies which provides the ability to control the electric field dose applied during tests. In this context, the proposed paper describes a new architecture of solid-state high-voltage pulse generators (SSHVPG) designed to generate fully customised sequences...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublicationIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
Evaluation of Facial Pulse Signals Using Deep Neural Net Models
PublicationThe reliable measurement of the pulse rate using remote photoplethysmography (PPG) is very important for many medical applications. In this paper we present how deep neural networks (DNNs) models can be used in the problem of PPG signal classification and pulse rate estimation. In particular, we show that the DNN-based classification results correspond to parameters describing the PPG signals (e.g. peak energy in the frequency...
-
Scientific Research Method
e-Learning Courses -
Compact and Integrated High-Power Pulse Generation and Forming System
PublicationThis paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...
-
Blood Pressure - Pulse Transit Time Relationships: Comparative Studies
PublicationA non-invasive and continuous blood pressure estimation could allow a better diagnosis and an earlier detection of various diseases. It could be performed using a photoplethysmography. However, it requires that a relation between blood pressure and pulse transit time is known. Eleven theoretical formulas were used in obtaining the simulated and noise free synthetic data. Then, they were utilized in validation of three, commonly...