displaying 1000 best results Help
Search results for: impedance%20spectroscopy
-
Noise in biological Raman spectroscopy
PublicationRaman spectroscopy is a widely used method to investigate chemical molecules by analyzing their vibrational transitions. It utilizes inelastic scattering of the laser light irradiating the investigated object. The scattered light requires appropriate filtering to reduce dominant laser light and expose much weaker components having shifted wavelengths of a characteristic spectral pattern. These components are measured by dispersing...
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 2.88 mm was measured at 693 K with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Linear impedance of Bi2VO5.5 ceramic prepared by traditional melt quenching technique measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrical properties of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nonlinear impedance of as-quenched glass 40Bi2VO5.5-60SrB4O7 after full crystallization was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of as-quenched glass 40Bi2VO5.5-60SrB4O7 afetr full crystallization was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nonlinear impedance of annealed and next fully crystallized 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of annealed and next fully crystallized 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of frequency for Bi2VO5.5 ceramic of thickness 2.88 mm was measured at high temperature range with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 fully crystallized glass at 813 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50Bi2VO5.5-50SrB4O7 fully crystallized glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50Bi2VO5.5-50SrB4O7 partially crystallized glass at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50Bi2VO5.5-50SrB4O7 partially crystallized glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 glass-ceramic heat-treated at 913 K was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 glass-ceramic heat-treated at 913 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of Bi2VO5.5 glass-ceramic heat-treated at 913 K was measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 glass-ceramic heat-treated at 913 K was measured by impedance spectroscopy method.
-
The Goertzel filter-bank usage in the non-stationary impedance measurement.
PublicationArtykuł prezentuje metodę pomiaru parametrów impedancyjnych w warunkach niestacjonarnych bazującą na próbkowaniu sygnałów pomiarowych i przetwarzaniu cyfrowym. Zaproponowano i przeanalizowano zastosowanie banku filtrów Goertzela. Porównano zaproponowane podejście z tradycyjnie stosowaną metodą STDFT. Przedstawiono wynik symulacji i pomiarów.
-
Identification and localization of organic coating degradation onset by impedance imaging
Publication -
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublicationW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Monitoring of CRT by means of impedance multiple measurements - simulation studies
PublicationCardiac resynchronization therapy (CRT) is a very promising treatment for patients with congestive heart failure. An Impedance Cardiography (ICG) is used for evaluation of heart mechanical activity. A simulation study with the use of a FEM model was performed. The developed realistic model of the thorax, based on CT data obtained from examination of a 68-year-old man, consisted of 212 000 tetrahedral elements. Different configurations...
-
Analysis of thoracic regional impedance changes using PCA approach
PublicationA multichannel impedance and one lead electrocardiographic recording system has been developed. The impedance measurement unit is built using a four-electrode technique. It consists of a sinusoidal, 40 kHz, current source and five measurement channels. Circumferential current electrodes have been located at a neck and an abdomen. Voltagemeasurement disk electrodes formed five two-electrode measurement ports. The impedance change...
-
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublicationBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
The influence of parameters of input probe on the error of high impedance measurement
PublicationW artykule przedstawiono sondę do pomiaru wysokich impedancji w zakresie 1kohm<|Zx|<100Gohm przeznaczoną do dołączenia do analizatorów typu gain-phase. Przeanalizowano wpływ parametrów sondy (pojemności pasożytnicze, toleranca rezystorów określających wzmocnienie wzmacniacza) na dokładność wyznaczenia modułu i argumentu zespolonego stosunku sygnałów wydzielonych w sondzie. Zamieszczono wyniki symulacji i pomiarów, pozwalające na...
-
The contribution of blood-flow-induced conductivity changes to measured impedance
PublicationW pracy rozwazane sa zmiany przewodnosci zachodzace w anizotropowym osrodku i ich wplyw na mierzona rezystancje. Uzyskano to za pomoca rozszerzenia wzoru Geselowizta na przypadki anizotropowe. Wykazano, ze tylko te skladowe zmian przewodnosci wplywaja na mierzona rezystancje, dla ktorych odpowiadajacy im skladnik pola eklektrycznego byl niezerowy.Wyniki te zastosowanu do zmian rezystywnosci wywolanych zmiananmi przewodnosci plynacej...
-
Validation of dynamic electrochemical impedance spectrograms using autocorrelation function
PublicationValidation of impedance data is essential for checking the reliability of experimental data. Kramers – Kronig transformation is used to verify data obtained from classical Electrochemical Impedance Spectroscopy (EIS) measurements. Data obtained from Dynamic Electrochemical Impedance Spectroscopy (DEIS) could be validated in the same way, but in this case, there is no information about internal consistency between every single spectrum...
-
Instantaneous impedance spectra of a non-stationary model electrical system
Publication -
Optimization of impedance measurements using ‘chirp’ type perturbation signal
Publication -
The application of impedance measurements for the determination of the probability of the course of corrosion processes
Publication -
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
Publication -
Electrochemical impedance studies of AB5-type hydrogen storage alloy
Publication -
Dual-Frequency Induction Heating Generator With Adjustable Impedance Matching
Publication -
Application of different modes of nanoscale impedance microscopy in materials research
Publication -
Optimization of impedance measurements using ''chirp'' type perturbation signal
PublicationW pracy przedstawiono innowacyjny sposób pomiaru impedancji przy użyciu sygnału niestacjonarnego "chirp". W procesie akwizycji pobudzenia i odpowiedzi prądowej zastosowano zmienną częstotliwość próbkowania. Podejście takie pozwala zarówno na wielokrotne zmniejszenie ilości niezbędnych do otrzymania widma impedancyjnego rejestrowanych danych jak również upraszcza i przyspiesza proces obliczeniowy. Stwierdzono iż dokładność wyników...
-
On-line measurement of cell impedance during charging and discharging process
PublicationW pracy przedstawiono założenia metody pomiaru impedancji, która w przeciwieństwie do dotychczasowych technik impedancyjnych stosowanych w badaniach ogniw, umożliwia pracę on-line. W celu zaprezentowania możliwości metody wykonano eksperyment polegający na cyklicznym ładowaniu i rozładowywaniu elektrody ołowianej w 4.8M H2SO4 z jednoczesnym pomiarem impedancji. Zmiany parametrów elektrycznych otrzymanych w wyniku analizy widm impedancyjnych...
-
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
Electrochemical impedance studies of AB5 -type hydrogen storage alloy
PublicationDo wyznaczenia własności stopu AB5 wykorzystano elektrochemiczną spektroskopie impedancyjną. Badania impedancyjne wykonano podczas chronowoltamperometri cyklicznej oraz cykli ładowania i rozładowania elektrody. Interpretacja uzyskanych w trybie potencjostatycznym wyników pozwoliła na dalszą interpretacje wyników uzyskanych w trybie galwanostatycznym. Proponowana metodologia umożliwia śledzić parametry elektryczne badanego układu...
-
Impedance investigations of amperometric gas sensor containing aprotic solvent
PublicationSkonstruowany został amperometryczny czujnik gazowy w układzie trójelektrodowym ze złotą elektrodą roboczą bezpośrednio napyloną na membranę Nafionową. W publikacji przedstawiono wyniki badań charakterystyk czujnika do oznaczania ditlenku siarki wypełnionego elektrolitem zawierającym różne względne zawartości DMSO/H2O. Wyniki badań impedancyjnych zostały przeanalizowane w oparciu o zaproponowany elektryczny układ zastępczy.
-
Impedance analysis of Portevin-Le Chatelier effect on aluminium alloy
PublicationW niniejszej pracy przeprowadzono badania elektrochemiczne powierzchniowego efektu PLC, związanego z nierównomiernym procesem płynięcia plastycznego stopów aluminium zawierających magnez. Występujący efekt PLC w postaci serration wywołuje niehomogeniczny proces zmian zewnętrznej powierzchni rozciąganej próbki. Wykonano badania metodą Dynamicznej Spektroskopii Impedancyjnej w warunkach dynamicznych prowadzenia procesu rozciągania....
-
An Application Supporting Gastroesophageal Multichannel Intraluminal Impedance-pH Analysis
PublicationDue to a significant rise in the number of patients diagnosed with diseases of the upper gastrointestinal tract and the high cost of treatment, there is a need to further research on one of the most popular diagnostic tests used in this case – esophageal Multichannel Intraluminal Impedance and pH measurement. This may lead to finding new diagnostically relevant information, used to quicken and improve the diagnostic procedure....
-
Impedance Studies of Phosphate-iron Glasses Containing Niobium and Titanium
PublicationThe ac and dc conductivity in phosphate-iron-niobate glasses with addition of titanium oxide was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and confocal microscopy methods. The obtained results show that all samples are amorphous but they...
-
A complete impedance analysis of electrochemical cells used as energy sources
PublicationA comprehensive description of impedance ofelectrochemical systems has been presented, along withthe assumptions of the method used. In this method, amultisinusoidal current excitation signal is used. Thechanges of potential of both the electrodes and thepotential difference between these electrodes are allregistered simultaneously as a function of time. Theproposed method offers the possibility of separatelydetermining the instantaneous...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
Multi-objective design of miniaturized impedance transformers by domain segmentation
PublicationFast multi-objective design optimization of compact microstrip impedance transformers is discussed. Our approach exploits approximation models constructed using sampled coarse- mesh EM simulation data in a partitioned design space and response correction techniques for design refinement. Demonstra
-
IMPEDANCE MEASUREMENT MODULE FOR GAS SENSORS WITH TEMPERATURE CONDITIONING FEATURE
PublicationThe paper presents an impedance measurement module which is aimed for gas sensor. Sensor’s heater temperature conditioning and modulation feature is available in order to allow implementation of different techniques improving selectivity and sensitivity of gas sensors. The measurement module uses three-parameter sine-fitting technique for impedance measurement. To monitor sensor temperature, the resistance of the sensor’s heater...
-
Application of different modes of nanoscale impedance microscopy in materials research
PublicationIn recent years, there is noticeable interest in application of various types of scanning probe microscopy in material science research. One of them is contact atomic force microscopy combined with local impedance measurements, known as nanoscale impedance microscopy. Literature references present its application in investigations of new materials, microelectronics diagnostics, or research of protective coatings performance. In...
-
BLOOD PRESSURE ESTIMATION BY MEANS OF A JOINT IMPEDANCE– PHOTOPLETYSMOGRAPHIC METHOD
PublicationThe knowledge of patient’s day to day blood pressure changes is invaluable to physicians for both diagnostics and health monitoring reasons. Constant observation of the pressure throughout a day would provide even more valuable clinical information. A convenient non-invasive methods of blood pressure estimation for monitoring purposes are widely proposed. This work shows a statistical approach to...
-
Applicability of an effective conductivity approach in modeling thoracic impedance changes
PublicationThis paper describes numerical simulations of the influence of conductivity changes inside a volume conductor on impedance changes measured on its surface. A simple model based on the finite element method has been developed to estimate an applicability of the effective conductivity theory in human chest modeling. The model consisted of a cylinder with two concentric spheres inside. Simulations were performed for two cases: first...
-
Impedancyjne badanie korozji wżerowej. Impedance measurements of pitting corrosion
PublicationKryteria zachodzenia korozji wżerowej związane są z badaniami tego zjawiska metodą cyklicznej polaryzacji i opierają się na wartości gęstości prądu lub bezwzględnej wartości prądu płynącego w układzie. Na podstawie przeglądu literaturowego wybrano cztery kryteria stosowane przy badaniu stali stopowych metodą cyklicznej polaryzacji. Dla warunków prądowych odpowiadających kryteriom zachodzenia korozji wżerowej przedstawiono widma...
-
Microsystem for measurement of impedance sensors parameters.Optoelectronic and electronic sensors V.
PublicationW artykule przedstawiono mikrosystem do pomiaru parametrów impedancyjnych czujników o module impedancji z przedziału 100ohm-1Gohm. Zastosowana w mikrosystemie technika cyfrowego przetwarzania sygnałów, pozwoliła na uzyskanie szerokiego zakresu częstotliwości pomiarowych, zwłaszcza bardzo niskich od 100uHz do 1MHz, przy zachowaniu prostej konstrukcji zapewniającej jego niską cenę. Mikrosystem zrealizowano w formie przyrządu...
-
Maciej Wróbel dr inż.
PeopleReceived PhD from Gdańsk University of Technology in 2019. Research interests involve non-invasive applications of Raman spectroscopy for tissue analysis, specifically blood parameters measurements. Tissue mimicking phantoms, measurement of optical properties (scattering, absorption), as well as other optical sensing methods. Raman spectroscopy and surface-enhanced Raman spectroscopy (SERS) utilized for measurements of biological...
-
ANNUAL REPORTS ON NMR SPECTROSCOPY
Journals -
JOURNAL OF NEAR INFRARED SPECTROSCOPY
Journals -
Nonlinear impedance as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of temperature and frequency for Bi2VO5.5 ceramic of thickness 2.52 mm was measured at different A.C. voltage with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 1.63 mm was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 1.63 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance of 40Bi2VO5.5-60SrB4O7 annealed glass at 473 K for 3 h measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of 40Bi2VO5.5-60SrB4O7 glass annealed at 473 K for 3h was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 4.03 mm was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 4.03 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 2.91 mm was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.91 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times measured with impedance spectroscopy method at low temperatures
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times was measured by impedance spectroscopy method.
-
Journal of Spectroscopy
Journals -
Evaluation of relative humidity effects on interfacial impedance at inter-coat interfaces.
PublicationSpektroskopia impedancyjna została zastosowana jako metoda niedestrukcyjna do oceny adhezji pomiędzy polimerowymi warstwami w ochronnym systemie powłokowym. Celem badań było stwierdzenie wpływu zewnętrznej wilgotności na impedancję międzyfazową. Badano system ochrony stosowany do ochrony samochodów. Zastosowano nowy sensor do detekcji rozwarstwienia i akumulacji wody w obszarze międzyfazy. Elektrody stanowią paski przewodzącego...
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems.
PublicationZmienne parametry środowiska takie jak: temperatura,wilgotność i promieniowanie UV powodują degradację własności ochronnych powłok organicznych. Stosując sensor w postaci elektrod wykonanych z prądoprzewodzącego tuszu umieszczonych pomiędzy warstwami zestawu oraz technikę spektroskopii impedancyjnej stwierdzono możliwość monitorowania utraty adhezji międzywarstwowej.
-
Impedance studies of diffusion phenomena and ionicand electronic conductivity of cerium oxide
PublicationW pracy zbadano właściwości elektryczne tlenku ceru z wykorzystaniem spektroskopii impedancyjnej. Badania wykazały występowania zjawiska dyfuzji, które jest prawdopodobnie związane z blokowaiem jonów na granicy faz. Bazując na zaproponowanym modelu obliczono przewodność elektronowa i jonową tlenku ceru.
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublicationThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Novel fast non-linear electrochemical impedance method for corrosion investigations
PublicationThe paper presents a novel approach to corrosion rate monitoring using non-linear electrochemical impedance spectroscopy. The authors propose a new variant of non-linear impedance measurement using amplitude-modulated multi-frequency ac perturbation signal. It allows shortening of measurement duration so it is possible to monitor corrosion rate of the systems experiencing rapid changes. In this way a limitation resulting from lack...
-
Theoretical description of fundamental-harmonic impedance of a two-step electrode reaction
Publication -
Application of impedance imaging to evaluation of organic coating degradation at a local scale
Publication -
Impedance-based sensing of the interlayer adhesion loss in organic coating systems
Publication -
A low-voltage CMOS negative impedance converter for analogue filtering applications
PublicationLow-voltage high-frequency continuous-time filters are still required in many applications and are the subject of continuing research. There are many techniques to realize integrated filters, including OTA C, Opamp RC and MOSFET-C-Opamp. The latter two show high dynamic range at low supply voltage, but their frequency operating range is usually limited to several megahertz. Transconductance filters are dedicated to higher frequencies....
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
Publication -
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublicationThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Cost-efficient simulation-driven design of compact impedance matching transformers
PublicationIn this paper, an algorithmic framework for cost-efficient design optimization of miniaturized impedance matching transformers has been presented. Our approach exploits a bottom-up design that involves translating the overall design specifications for the circuit at hand to its elementary building blocks (here, compact microstrip resonant cells, CMRCs), as well as fast surrogate-assisted optimization of the cells followed by simulation-based...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
PublicationLocal impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 1016 to 2 × 1021 atoms cm−3. The BDD films displayed microcrystalline structure,...
-
A family of new generation miniaturized impedance analyzers for technical object diagnostics
PublicationThe paper presents the family of three analyzers allowing to measure impedance in range of 10 ohm<|Zx|<10 Gohm in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzers family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of impedance measurement method based on digital signal processing DSP. The miniaturization and other above mentioned...
-
Aplication of impedance imaging to evaluation of organic coating degradation at a local scale
PublicationZaproponowano nowe podejście do oceny lokalnych właściwości elektrycznych powłok organicznych. Wykorzystuje ono mikroskop sił atomowych pracujący w trybie kontaktowym. Pomiędzy igłę mikroskopu i podłoże metalowe pokryte powłoką przykładany jest sinusoidalny napięciowy sygnał pobudzenia o zadanej częstotliwości i mierzony jest prądowy sygnał odpowiedzi. Zalety tego podejścia zostały zaprezentowane na przykładzie powłoki akrylowej...
-
Nonlinear impedance in oxide glasses containing single and mixed alkali ions
PublicationThe aim of the present was to find more clues on the nonlinearities in impedance of oxide glasses. The first family of researched glasses has a composition of FeO-P2O5-Na2O. Oxide glasses containing iron and alkali are well known for a very low alkali ion mobility and may be considered purely polaron conducting. These glasses show no detectable nonlinearities in the impedance spectra. The second was a family of ionic conducting...
-
Application of multisine nanoscale impedance microscopy to heterogeneous alloy surface investigations
PublicationIn the recent years atomic force microscopy is recognized as valuable tool for investigation of surficial features of construction materials. It concerns, among other things, studies of changes caused by such phenomena as galvanic corrosion, passivation associated with the growth of oxide layers, or sensitization of austenitic steels with the formation of carbide phases. In addition, atomic forcemicroscopy allows easy coupling...
-
A telemedical and an outpatient thoracic impedance measurements - a validation algorithm of the electrodes placement
PublicationThis paper presents the algorithm for validation of electrodes locations for the thoracic impedance measurements. In particular the presented algorithm was designed to perform the telemetric sleep apnea monitoring. One of the problems, during the clinical tests of a developed device, was to preserve the repeatability of measurements. It strongly depended on the appropriate electrodes placement on the examined person’s thorax. It...
-
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublicationThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...
-
Finding the protection of lighting grounding with estimating its impulse impedance componets
PublicationOmówiono metodę rozdzielania składowych impedancji udarowej uziemień. Podano wskazania dotyczące oceny jakości ochrony odgromowej na podstawie wartości składowych impedancji udarowej.
-
Application of spectroscopy to the measurement of blood parameters
PublicationSpectroscopy is the study of formation and interpretation of the spectra arising from the interactions of all types of radiation on matter, understood as a collection of atoms and molecules. This is a very important department of optics which gives us many opportunities to measure various parameters such as material blood parameters. Among the diseases that are associated significantly with changes in rheological properties of...
-
Ultrasonic spectroscopy of silicon single crystal
PublicationSpecimens of Si single crystals with different crystal orientation [100] and [110] were studied by the electro-ultrasonic spectroscopy (EUS) and Resonant Ultrasonic Spectroscopy (RUS). A silicon single crystal is an anisotropic crystal, so its properties are different in different directions in the material relative to the crystal orientation. EUS is based on interaction of two signals: electric AC signal and ultrasonic signal,...
-
Time-of-flight spectroscopy for medical applications.
PublicationW pracy przedstawiono korzyści optycznej spektroskopii czasu przelotu, w zastosowaniach medycznych. Przedstawiono także zasadę pomiarów oraz pokazano, jak z danych pomiarowych można wyznaczyć podstawowe parametry optyczne tkanki. Potencjał pomiarowy optycznej spektroskopii czasu przelotu zaprezentowano na przykładzie pomiarów ośrodków silnie rozpraszających światło jakimi są: papier, cicze technologiczne z papierni, wodne roztwory...
-
Theory and application of Near-infrared spectroscopy
PublicationIn recent years one can observe a significant increase in the requirements on quality control in all industrial sectors. The growing number of involved analyses makes the traditional, time consuming, requiring use of large quantities of reagents, thus expansive methods inconvenient especially for industrial applications. Fortunately, there is a very fast, cheap and not invasive analytical method that is increasingly used in qualitative...
-
Raman spectroscopy in investigation of rheometric processes
PublicationPraca porusza problem analizy cienkiej warstwy przyściennej -oleju za pomocą spektroskopii ramanowskiej. Parametry (grubość, struktura chemiczna) cienkiej warstwy przyśniennej są istotną informacją do oceny przebiegu procesu wyciskania past modelowych. Zaprezentowano wyniki pomiarów oraz konstrukcje ramanowskich układów pomiarowych.
-
Saturation ESR spectroscopy of PA12 polyamide
Publication -
Application of NIR and Raman Spectroscopy in Biotechnology
PublicationStudium Press LLC, U.S.A.
-
Raman spectroscopy in investigation of rheometric processes
Publication -
Integrating Optical Spectroscopy and Chemometric Methods
Publication -
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated two times was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of glass 40Bi2VO5.5-60SrB4O7 annealed at 593 K and next fully crystallized was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of glass 40Bi2VO5.5-60SrB4O7 annealed at 593 K and next fully crystallized was measured by impedance spectroscopy method.
-
Model dynamic electrochemical impedance spectroscopy (DEIS) results obtained with various DC polarization rates
Open Research DataThe dataset contains results of model dynamic electrochemical impedance spectroscopy studies carried out on a setup of 10 diodes in series, which were connected in parallel with a condenser. The impedance data were acquired every 1 s (the analytic window length for Fourier Transform was 1 s). The model system was polarized between 0 and +8 V with DEIS...
-
Nonlinear impedance as a function of A.C. voltage for annealed and next fully crystallized 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for annealed and next fully crystallized 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 813 K measured with impedance spectroscopy method at high temperature region
Open Research DataNonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 813 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of glass 40Bi2VO5.5-60SrB4O7 annealed at 473 K for 3h and next fully crystallized was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties of glass 40Bi2VO5.5-60SrB4O7 annealed at 593 K and next fully crystallized was measured by impedance spectroscopy method.
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K was measured by impedance spectroscopy method.
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataNonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 613 K was measured by impedance spectroscopy method.
-
Interface circuit for impedance sensors using two specialized single-chip microsystems
PublicationW artykule przedstawiono obwód interfejsu przeznaczony do pomiaru parametrów impedancyjnych czujników lub celek pomiarowych instalowanych na obiektach technicznych. Umożliwia on pomiar modułu i argumentu impedancji w zakresie 10ohm
-
Impedance investigation of passive 304 stainless steel in the pit pre-initiation state
PublicationZaprezentowano wyniki badań impedancyjnych stali stopowej 304L metodą klasycznej EIS i dynamicznej EIS. Badania związane były z przejściem stali stopowej ze stanu pasywnego do inicjacji powstawania wżerów. Na podstawie zmian parametrów elektrycznego schematu zastępczego stwierdzono, że najbardziej prawdopodobnym mechanizmem tworzenia się wżerów jest model zniszczenia (pęknięcia) warstwy pasywnej.