Filters
total: 11822
-
Catalog
- Publications 9231 available results
- Journals 332 available results
- Conferences 31 available results
- Publishing Houses 3 available results
- People 392 available results
- Projects 12 available results
- Laboratories 1 available results
- Research Teams 1 available results
- Research Equipment 1 available results
- e-Learning Courses 230 available results
- Events 29 available results
- Offers 1 available results
- Open Research Data 1558 available results
displaying 1000 best results Help
Search results for: ups , short-circuit , fault loop impedance measurement , power quality , electrical safety
-
Transient States during Short-circuit in a Line Powered by UPS and its Impact on Earth Fault Loop Impedance Measurement and Power Quality
PublicationThe short-circuit in a line powered by Uninterruptible Power Supply (UPS) during different UPS operation modes is presented in the article. The transient state condition related to the short-circuit in a line fed from double conversion On-line UPS is discussed in detail. The results of the measurements of earth fault loop impedance (FLI) in circuits powered by UPS with the instruments of various manufacturers are presented. The...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
STANY NIEUSTALONE TOWARZYSZĄCE POMIAROWI IMPEDANCJI PĘTLI ZWARCIA W OBWODACH WYJŚCIOWYCH ZASILACZY BEZPRZERWOWYCH UPS
PublicationW pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
The loop impedance measurement
Open Research DataThe loop impedance measurement
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Broken rotor bar impact on sensorless control of induction machine
PublicationThe aim of the research is analysis of the sensorless control system of induction machine with broken rotor for diagnostic purposes. Increasing popularity of sensorless controlled variable speed drives requires research in area of reliability, range of stable operation, fault symptoms and application of diagnosis methods. T transformation (Cunha et al.,2003) used for conversion of instantaneous rotor currents electrical circuit...
-
Trends in Locally Balanced Energy Systems without the Use of Fossil Fuels: A Review
PublicationIn recent years, the idea of the operation of energy systems (power systems, heating systems) has changed significantly. This paper is an overview of locally balanced energy systems without the use of fossil fuels. The paper justifies the concept of local energy balancing in a new energy system that does not use fossil fuels (coal, natural gas, and crude oil), based on European Union guidelines and formal documents as well as the...
-
Modelling and analysis of a synchronous generator in more electric aircraft power system using Synopsys/Saber simulator = Modelowanie i analiza generatora synchronicznego w systemie elektroenergetycznym nowoczesnego samolotu. Zastosowanie symulatora Synopsys/Saber
PublicationStreszczenie angielskie: A model for studying synchronous machine (SM) dynamic behaviour in more electric aircraft (MEA) power system is developed and implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SM model. The elaborated model exhibit a network with the same number of external terminals/ports as the real SM, and represents its behaviour in terms of the electrical...
-
Piotr Grudowski dr hab. inż.
PeopleProfessor Dr hab. Eng. Piotr Grudowski heads the Department of Quality and Commodity Management at the Faculty of Management and Economics of Gdansk University of Technology. In the years 1987-2009 he worked at the Faculty of Mechanical Engineering of the Gdansk University of Technology, where he obtained a doctoral degree in technical sciences in the discipline of construction and operation of machines and he headed the Department...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Magnetic Field Generated by Short Circuit Current in the 110 kV Power System
PublicationElectric fields within tissues induced by magnetic fields including transients or short-term peaks should not be time averaged and be regarded as instantaneous values as established in the ICNIRP (International Commission on Non - Ionizing Radiation Protection) guidelines. Measurements of power lines magnetic fields with regard to human beings exposure are carried out typically with maximum current load at current balance condition...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Open Research Data1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
Influence of the method of the control of the hybrid contactless short-circuit limiter on power quality
PublicationW artykule przedstawiono wpływ sterowania bezstykowego ogranicznika prądów zwarciowych na ograniczanie zapadów napięcia. Scharakteryzowano podstawowe własności ogranicznika oraz układu sterowania jego pracą. Ponieważ prąd zwarciowy jest detekowany przez dedykowany superkrótki bezpiecznik sterowanie musi być dostosowane do czasu przedrukowego i łukowego topika, które zależą od aktualnej wartości prądu i aktualnej konfiguracji obwodu....
-
Paweł Burdziakowski dr inż.
PeoplePaweł Burdziakowski, PhD, is a professional in low-altitude aerial photogrammetry and remote sensing, marine and aerial navigation. He is also a licensed flight instructor and software developer. His main areas of interest are digital photogrammetry, navigation of unmanned platforms and unmanned systems, including aerial, surface, underwater. He conducts research in algorithms and methods to improve the quality of spatial measurements...
-
Impedance Measurement and Selection of Electrochemical Equivalent Circuit of a Working PEM Fuel Cell Cathode
PublicationThe dynamic impedance analysis of direct methanolfuel cell (DMFC) cathode supplied with pure oxygen is pre-sented. Presented results were obtained during dynamic chang-es of the current density in working fuel cell. Investigation ofthe occurring processes at cathode was carried with dynamicelectrochemical impedance spectroscopy (DEIS). A discussionwas conducted based on the determined correlation parameterχ2. It was shown that...
-
Michał Michna dr hab. inż.
PeopleMichal Michna received the M.Sc. and Ph.D. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 1998 and 2005, respectively. Since 2004, he was employed at the Department of Power Electronics and Electrical Machines of the Gdańsk University of Technology (assistant, assistant professor, senior lecturer). In 2010-2015 he was a deputy of head of the Department of Power Electronics and...
-
The influence of dynamic load changes on temporary impedance in hydrogen fuel cells, selection and validation of the electrical equivalent circuit
PublicationTo achieve optimal performance of a fuel cell, a reliable monitoring and diagnostic method is required. The currently utilized methods give limited information or they are impossible to use under dynamic working conditions. To obtain comprehensive information about the fuel cell operation we utilized novel dynamic electrochemical impedance spectroscopy. Impedance measurements in dynamic mode were performed on a hydrogen fuel cell,...
-
MEASUREMENT
Journals -
Janusz Nieznański prof. dr hab. inż.
PeopleJanusz Nieznański born in 1957 in Gdańsk. He received the M.Sc. degree in 1981, the Ph.D. degree in 1990, and the D.Sc. (‘habilitation’) degree in 1999, all from the Gdańsk University of Technology. Since 1981 he has been with the above university, where he is currently Professor of Electrical Engineering. His research and teaching interests include control, diagnostics, modeling and simulation of power electronic converters and...
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Power Hardware-in-the-Loop Approach In Power System Development
PublicationThe main objective of the research is the verification of the Power Hardware-In-The-Loop (PHIL) approach in power system analysis and design. The premise of the article is that using PHIL approach the performance of the power system in steady and transient state conditions can be analysed in real power system conditions. Models of induction machine were developed and real time simulations were performed. Simulation variables were...
-
Measurement Automation Monitoring
Journals -
Jarosław Guziński prof. dr hab. inż.
PeopleJaroslaw Guzinski received M.Sc., Ph.D. and D.Sc. degrees from the Electrical Engineering Department at Technical University of Gdansk, Poland in 1994, 2000 and 2011 respectively. Since 2016 he is Associate Professor at Gdansk University of Technology. Currently he is the head of the Department of Electric Drives and Energy Conversion. From 2006 to 2009 he was involved in European Commission Project PREMAID Marie Curie, ‘Predictive...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Investigation on accelerated impedance spectrum measurement method with multisine signal stimulation
PublicationThe paper presents an investigation on the accelerated impedance spectrum measurement method, oriented at parameter identification of technical objects modelled by a linear equivalent circuit, e.g. anticorrosion coatings.The method is based on multisine signal stimulation of an object and response analysis by triangle window filterbanks.It has several advantages, as compared with conventional point-by-point spectrum measurement....
-
Power Hardware-In-the-Loop Approach for Autonomous Power Generation System Analysis
PublicationThe article presents the Power Hardware-In-the-Loop (PHIL) dynamic model of a synchronous generator of 125 kVA for autonomous power generation system analysis. This type of system is typically composed of electrical energy sources in the form of several diesel generator units with synchronous machines, the main distribution switchboard and different loads. In modern power distribution systems, the proposed power management strategies...
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublicationThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
Multispectral impedance quality testing of coil-coating system using principal component analysis
PublicationThe task of quality checking of the coil-coated system was undertaken using impedance spectroscopy. In order to properly characterize the system the new impedance spectrum was calculated as an averaged result of 12 experimental spectra obtained from 12 different places of the sample at the same time of immersion in 3% of NaCl. The experimental spectra were recorded for a 24-h period at 1 h intervals between starting points of each...
-
Models of Brushless Synchronous Generator for Studying Autonomous Electrical Power System
PublicationThis is a PhD dissertation. The work presented in this monograph was carried out at the Department of Power Electronics and Electrical Machines, Faculty of Electrical and Control Engineering at the Gdansk University of Technology. Developed during the research models of brushless synchronous generator ware verified using FEM based simulations and measurements conducted on the prototype generator. The main focus of the research...
-
Effect of hybrid contactless short-cicruit limiters on power quality
PublicationPrzedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulację komputerową. Szczególną uwagę zwrócono na problem jakości dostarczanej energii elektrycznej poprzez ograniczanie zapadów napięcia za pomocą bezstykowego ogranicznika prądów zwarciowych. W modelowaniu elementów systemu elektroenergetycznego i zapadów napięcia, będących skutkiem zwarć wykorzystano program MATLAB z biblioteką Power System Blockset....
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Grzegorz Lentka dr hab. inż.
PeopleGrzegorz Lentka obtained his MSc title in electronics, specialization Measurement Systems at Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1996. He obtained the PhD title in 2003 and habilitation in 2014, respectively. Currently he is an professor in Department of Metrology and Optoelectronics. His main scientific interests are focused on digital signal processing for metrology,...
-
Metrology and Measurement Systems
Journals -
Stability Analysis of Shunt Active Power Filter with Predictive Closed-Loop Control of Supply Current
PublicationThis paper presents a shunt active power filter connected to the grid via an LCL coupling circuit with implemented closed‐loop control. The proposed control system allows selective harmonic currents compensation up to the 50th harmonic with the utilization of a model‐based predictive current controller. As the system is fully predictive, it provides high effectiveness of the harmonic reduction, which is proved by waveforms achieved...
-
Roland Ryndzionek dr inż.
PeopleI received the M.Sc. degree in Electrical Engineering from Gdańsk University of Technology (Gdańsk Tech), Gdańsk, Poland, in 2010, the M.Sc. degree in Electrical Engineering from INP ENSEEIHT, Toulouse, France, in 2012, and the Ph.D. degree in Electrical Engineering from Gdańsk Tech and INP, in 2015. From 2015 to 2017. I was a postdoctoral research engineer at the SuperGrid Institute Lyon, France. Since 2017, I have been working...
-
Novel Fault Identification for Electromechanical Systems via Spectral Technique and Electrical Data Processing
PublicationIt is proposed, developed, investigated, and validated by experiments and modelling for the first time in worldwide terms new data processing technologies, higher order spectral multiple correlation technologies for fault identification for electromechanical systems via electrical data processing. Investigation of the higher order spectral triple correlation technology via modelling has shown that the proposed data processing technology...
-
Automatic tuning of a resonant circuit in wireless power supply systems for biomedical sensors
PublicationIn this paper, a tuning method of a resonant circuit suited for wireless powering of miniature endoscopic capsules is presented and discussed. The method allows for an automatic tuning of the resonant frequency and matching impedance of a full wave rectifier loading the resonant circuit. Thereby, the receiver tunes so as to obtain the highest power efficiency under given conditions of transmission. A prototype receiver for wireless...