Filters
total: 3406
filtered: 2499
-
Catalog
- Publications 2499 available results
- Journals 58 available results
- Conferences 13 available results
- Publishing Houses 3 available results
- People 153 available results
- Inventions 2 available results
- Projects 17 available results
- Research Teams 3 available results
- Research Equipment 1 available results
- e-Learning Courses 79 available results
- Events 8 available results
- Open Research Data 570 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: FLUORIDE SENSOR
-
Influence of Humidity on Parameters of Amperometric Sensor with Nafion Membrane
PublicationPrzedstawiono wyniki badań wpływu umiarkowanych i wysokich wilgotności powietrza na sygnał, czułość i czas odpowiedzi prototypowego czujnika ditlenku siarki ze złotą elektrodą pracującą, próżniowo napyloną na powierzchnię membrany nafionowej. Zaprezentowano także wyniki badań impedancyjnych w zakresie potencjałów, w którym mechanizm utleniania ditlenku siarki jest kontrolowany aktywacyjnie i dyfuzyjnie. Parametry odpowiadające...
-
Optical Diffraction Strain Sensor Prepared by Interference Lithography
Publication -
Detection of Water on Road Surface with Acoustic Vector Sensor
PublicationThis paper presents a new approach to detecting the presence of water on a road surface, employing an acoustic vector sensor. The proposed method is based on sound intensity analysis in the frequency domain. Acoustic events, representing road vehicles, are detected in the sound intensity signals. The direction of the incoming sound is calculated for the individual spectral components of the intensity signal, and the components...
-
Distributed Trust Management Model for Wireless Sensor Networks
Publication -
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
an intelligent image processing sensor - the algorithm and the hardware implementation
PublicationW artykule przedstawiono algorytm przeznaczony do rozpoznawania obiektów ruchomych w obrazie do celu analizy ruchu pojazdów. Algorytm został zrealizowany w układzie FPGA.Ang.: This paper describes the idea and theimplementation of the robust algorithm dedicated toextraction of moving vehicles from real-time cameraimages for the evaluation of traffic parameters, suchas the number of vehicles, their direction of movementand their...
-
Localization in wireless sensor networks based on zigbee platform
PublicationW artykule porównano dwie różne metody lokalizacji w sieciach sensorów bezprzewodowych. Jedną z metod jest implementacja sprzętowa algorytmu w układzie nadawczo odbiorczym CC2431. Drugą metodą jest implementacja programowa. Wyniki testów przeprowadzonych na otwartym terenie oraz w pomieszczeniach zamkniętych zostały przedstawione i porównane w pracy.
-
Wave propagation in a sensor/actuator diffusion bond model
Publication -
Analytical characteristics of a new amperometric sulfur dioxide sensor
PublicationZaprojektowano i skonstruowano wyposażony w układ trójelektrodowy amperometryczny czujnik ditlenku siarki. Elektroda pracująca czujnika była napylona bezpośrednio na powierzchnię membrany. Zbadano charakterystyki czujnika z membranami z mikroporowatego Teflonu oraz Nafionu. Porównano parametry statyczne i dynamiczne tych czujników wypełnionych roztworami elektrolitów wewnętrznych, zawierających dodatek dimetylosulfotlenku.
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Pattern matching localization in ZigBee wireless sensor networks.
PublicationLokalizacja typu Pattern matching w sieciach sensorów bezprzewodowych ZigBee.Prezentacja metod implementacji algorytmów lokalizacji. Praktyczne zastosowanie i testowanie lokalizacji sieci ZigBee.
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
<title>LabWindows: tool and environment for sensor design</title>
Publication -
New Manufacturing Method Of Sensor Oriented Optical Fibers
Publication -
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationProperties of sensor based on Nasicon with two round shaped platinum electrodes are investigated. Influence of different chlorine concentrations on the sensor response is presented. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Optimal placement of IMU sensor for the detection of children activity
PublicationIn this paper an investigation to determine the optimal placement of IMU sensors for the purpose of children characteristic activity detection is presented. The article compares four different placement of two IMU sensors on human body. Ten healthy volunteers participated within the study. Data were collected firstly from two wireless 9-axial IMU sensors placed at the left and right wrists, then sensors were placed at lower back...
-
Photonic sensor to detect rapid changes in CRP levels
PublicationOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublicationThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
A model of the response of the MGS-6 gravity sensor to tilting
PublicationThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
Planar Microwave Bragg Reflector Resonant Dielectric Sensor
PublicationIn this paper, a periodic structure is used to design a microwave Bragg reflector with the help of hexagonal lattice, which provides a 5 GHz wide stopband between the low-pass band with cut-off frequency 2.6 GHz and the bandpass response with start and stop frequency 7.8 GHz and 10.5 GHz, respectively. A defect in lattice allows passing a narrowband signal at 6 GHz which is found, from the dispersion relation, to be in the region...
-
Trajectories detection in a distributed multi-sensor tracking system
PublicationW pracy rozważono problem śledzenia obiektów poruszających się za pomocą rozproszonego systemu wieloczujnikowego. Głównym zadaniem systemu śledzenia jest detekcja i estymacja trajektorii obiektów poruszających się w obserwowanej przestrzeni. Trajektoria obiektu to ciąg estymat kinematycznego stanu obiektu, jego pozycji, prędkości, itp. Klasyczne systemy śledzenia oparte są na filtrze Kalmana korzystającym z danych z pojedynczego...
-
Poly(vinylidene fluoride) and Carbon Derivative Structures from Eco-Friendly MOF-5 for Supercapacitor Electrode Preparation with Improved Electrochemical Performance
Publication -
Temperature and pressure dependence of the luminescence of Eu2+-doped fluoride crystals BaxSr1−xF2(x= 0, 0.3, 0.5 and 1): experiment and model
Publication -
Horizontally-split-drain MAGFET - a highly sensitive magnetic field sensor
PublicationWe propose a novel magnetic field sensitive semiconductor device, viz., Horizontally-Split-Drain Magnetic-Field Sensitive Field-Effect Transistor (HSDMAGFET) which can be used to measure or detect steady or variable magnetic fields. Operating principle of the transistor is based on one of the galvanomagnetic phenomena and a Gradual Channel Detachment Effect (GCDE) and is very similar to that of Popovic and Baltes's SDMAGFET. The...
-
Gas mixtures recognition using an array of amperometric gas sensors with drifting or faulty sensors
PublicationIn this study, the possibility of using selected methods for diagnostics of performance of matrix composed with six amperometric electrochemical gas sensors is investigated. Measurements of sensor responses in selected concentrations of single toxic gases or gas mixtures were performed and were repeated over time to show sensor drift. Additionally, the studies on the sensors’ drift were performed. The drift has been recognized...
-
Multicore Optical Fibres For Sensors
Publication -
Sensors and System for Vehicle Navigation
PublicationIn recent years, vehicle navigation, in particular autonomous navigation, has been at the center of several major developments, both in civilian and defense applications. New technologies, such as multisensory data fusion, big data processing, or deep learning, are changing the quality of areas of applications, improving the sensors and systems used. Recently, the influence of artificial intelligence on sensor data processing and...
-
Potentiometric taste sensor application for liquid product taste estimation
PublicationThe principles of taste sense and kinds of tastes (sweet, salty, sour, bitter, umami and fat) have been described. Food quality estimation by taste sense: organoleptic testing and sensory analysis has been presented. The principle of operation of potentiometric sensor composed of several Ion Selective Electrodes or All Solid State Electrodes with polymeric membranes and macromolecular chemical compounds sensitive to substances...
-
Detection of immunological agent by optical fiber sensor: preliminary study
PublicationThe objective of this study is the application of optical methods for detection of immunological agent concentration. As the agent we used the Cyclaid, produced by Apotex Inc. In this article we investigated different Cyclaid concentrations in water. We used a Fabry-Pérot interferometer working in a reflective mode, the measurements were performed with source with central wavelength λ = 1550 nm. The preliminary investigation have...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Transmission protocol simulation framework for the resource-constrained sensor network
PublicationIn this paper the simulation framework for simulation of the sensor network protocol is presented. The framework enables the simultaneous development of the sensor network software and the protocol for the wireless data transmission. The advantage of using the framework is the convergence of the simulation with the real software, because the same software is used in real sensor network nodes and in the simulation framework. The...
-
Power quality conditioners with minimum number of current sensor requirement
Publication -
Gesture Recognition With the Linear Optical Sensor and Recurrent Neural Networks
PublicationIn this paper, the optical linear sensor, a representative of low-resolution sensors, was investigated in the multiclass recognition of near-field hand gestures. The recurrent neural network (RNN) with a gated recurrent unit (GRU) memory cell was utilized as a gestures classifier. A set of 27 gestures was collected from a group of volunteers. The 27 000 sequences obtained were divided into training, validation, and test subsets....
-
Wavelet Transform Analysis of Temperature Modulated Gas Sensor Response
PublicationThe aim of the study was to evaluate whether it is possible to extract the information about the gas concentration despite the influence of humidity. Commercial semiconductor sensor response was examined under the application of a periodic temperature change. The data was collected using measurement protocol for different concentrations of ammonia at specified levels of relative humidity. In this work we focused on the evaluation...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublicationMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Pose classification in the gesture recognition using the linear optical sensor
PublicationGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
Modeling of active fiber Bragg grating underwater acoustic sensor.
PublicationW pracy przedstawiono wyniki modelowania nowego typu przetwornika hydroakustycznego wykorzystującego światłowodową siatkę Bragga. Siatka ta, domieszkowana jonami pierwiastków ziem rzadkich, pracuje jako laser z rozłożonym sprzężeniem zwrotnym, co pozwala na znaczne zwiększenie czułości tego prztwornika w porównaniu z rozwiązaniami wykorzystującymi siatki pasywne. W celu uzyskania równomiernego rozkładu naprężeń siatki zastosowano...
-
Sandwich Biobattery with Enzymatic Cathode and Zinc Anode Integrated with Sensor
PublicationCarbon paper covered with side-naphthylated multi walled carbon nanotubes was used as the conducting support for the construction of a biocathode in a hybrid biofuel cell. Laccase Carrena unicolor enzyme was employed as the catalyst for the 4e reduction of oxygen and a zinc disc covered with hopeite was used as the anode. Derivatized carbon nanotubes increase the working surface of the electrode and provide direct contact with...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Analysis of unsteady flow forces on the thermowell of steam temperature sensor
PublicationIn this paper, 3D numerical analysis of unsteady flow forces acting on the measuring sheath of steam temperature is presented. According to that purpose, the CFD (Computation Fluid Dynamic [1]) approach has been used. The nonstationary of fluid acting on the measuring sheath such as: Strouhal frequency, amplitude of pressure, structure of vortex, peak of pressure, field of pressure, field of velocity etc. are studied analytically...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
The influence of electrocatalytic toxic gas sensor construction on its performance
PublicationW pracy przedstawiono porównanie właściwości elektrokatalitycznych czujników gazów przygotowanych na bazie różnych elektrolitów stałych oraz wykonanych w różnych technologiach.
-
Sensitivity to nitrogen dioxide of electrocatalytic gas sensor based on NASICON
PublicationW pracy przedstawiono wyniki badań czujnika elektrokatalitycznego na bazie NASICONu.
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationScent or aroma sensing during aromatherapy can be carried out by applying only a single resistance gas sensor (TGS - Taguchi Gas Sensors). This paper considers the efficiency of detection of essential oils by DC resistance and its fluctuations observed in TGS sensors. A detailed study has been conducted for scents emitted by five popular essential oils using three sensor types (TGS 2600, TGS 2602, TGS 823). The research was focused...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublicationThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
-
Electrical properties of poros nanocrystalline undoped ceria oxygen sensor
PublicationW pracy zaprezentowano wykonanie czujnika z niedomieszkowanego tlenku ceru o nanometrowych ziarnach krystalicznych. Zastosowana metoda nanoszenia warstw zalicza się do metod niskotemperaturowych. Wytworzone warstwy przebadano za pomocą dyfrakcji rentgenowskiej, mikroskopii elektronowej oraz spektroskopii impedancyjnej. Wykonane czujniki charakteryzują się szybkim czasem odpowiedzi i stabilnym zachowaniem przy zmianach ciśnienia...