displaying 1000 best results Help
Search results for: deceleration capacity
-
Hydrogen direct reduction and reoxidation behaviour of high-grade pellets
PublicationHigh grade pellets with basicity index close to 0.5 were directly reduced in pure hydrogen atmosphere. The reduction experiments were performed in the temperature range 800 e1000 C at the pressure of 8 bar. The pellets internal structure was analysed through micro tomography observations in the unreduced and reduced conditions. After reduction, the pellets showed a variation of porosity up to more than 15% with a remarkable change...
-
Exhaust gas temperature measurements in diagnostic examination of naval gas turbine engines. Part III. Diagnostic and operating tolerances
PublicationThe third part of the article presents a method for detecting failures of the automatic engine control system with the aid of an exhaust gas temperature setter, specially designed and machined for this purpose. It also presents a procedure of identifying the operating tolerances and determining the diagnostic tolerances for the exhaust gas temperature recorded in the naval turbine engine during the start-up and acceleration processes....
-
Dynamic soil improvement by hybrid technologies
PublicationHybrid method of subsoil improvement for road embankment foundation is described. This method is composed of two wellknown methods: dynamic replacement (DR) and microblasting (DDC) one (Deep Dynamic Compaction). The method was used for both the strengthening of the fully saturated organic subsoil as well as for acceleration of the consolidation of the organic layers. The practice ensures the expected results. A proper example on...
-
Shaking table experimental study on models of steel buildings with different types of joints
PublicationThe aim of this paper is to study the response of models of steel buildings with destroyed and non-destroyed joints. The study was conducted experimentally using the shaking table tests. Two steel models were considered. Several types of joints were taken into account: totally destroyed joints, partially destroyed joints, welded joints and joints stiffened with additional metal. Six ground motions were taken into account. The acceleration...
-
Modelowanie losowych imperfekcji geometrycznych przestrzennych konstrukcji metalowych
PublicationImperfekcje geometryczne zbiorników, silosów i powłok siatkowych mogą znaczą-co wpłynąć na ich nośność, a więc powinny być one uwzględniane w obliczeniach komputerowych i w procesie projektowania. Wykazano, że przy podstawowych obcią-żeniach, działających na tego typu konstrukcje, tj. podciśnieniu oraz naporu wiatru i śniegu (w przypadku powłok siatkowych), wykazują wyraźne różnice w porównaniu z analogicznymi wynikami dla tych...
-
Modyfikacja połączenia dźwigara ze słupem w konstrukcji stalowej Terminalu T2 Portu Lotniczego w Gdańsku
PublicationW2015 r. ukończono rozbudowę Terminalu T2 Portu Lotniczego im. Lecha Wałęsy wGdańsku. Politechnika Gdańska pełniła nadzór naukowy nad rozbudową obiektu. Wykonano wiele analiz, których celem była weryfikacja pracy konstrukcji w fazach montażu oraz w stanie docelowym. Wnioski z przeprowadzonych badań doprowadziły do modyfikacji oparcia dźwigarów dachowych na stalowych słupach nośnych, z uwagi na stwierdzone lokalne przekroczenia...
-
Fermi-liquid behavior of binary intermetallic compounds Y3 M (M = Co, Ni, Rh, Pd, Ir, Pt)
PublicationA series of polycrystalline samples of Y3 M (M = Co, Ni, Rh, Pd, Ir, Pt), intermetallic binary compounds were synthesized by the arc-melting method. Powder x-ray diffraction (pXRD) confirmed the orthorhombic cementite-type crystal structure and allowed for the estimation of the lattice parameters. Physical properties were investigated by means of electrical resistivity and heat capacity measurements between 1.9 K and 300 K. All...
-
Development, characterization and evaluation of composite adsorbent for the adsorption of crystal violet from aqueous solution: Isotherm, kinetics, and thermodynamic studies
PublicationThe purpose of this work focuses on the production and investigations of a new composite material as alternative low-cost adsorbent for the removal of crystal violet (CV) dye from waste solution. The production method was performed by in-situ thermal activation technology via extrusion process of polymer wastes containing tire rubber (50 wt%) and polyurethane foam (50 wt%) using single-screw extruder under processing temperature...
-
Managerial Energy in Sustainable Enterprises: Organizational Wisdom Approach
PublicationThe circular economy (CE) as an idea involves applying the concept of sustainable development that has been gaining worldwide support. This shift in perception of energy and resource-use from its linear to circular forms creates a specific business environment, which constitutes the subject of this research. This article aims to analyze the impact of a manager’s energy on organizational wisdom, focusing on its circular business...
-
Characterization of diatomaceous earth coated with nitrated asphaltenes as superior adsorbent for removal of VOCs from gas phase in fixed bed column
PublicationAsphaltenes isolated from bitumen possess unusual adsorption characteristics that can be further enhanced by chemical modifications to promote interactions with VOCs’. Herein, nitrated asphaltenes are used as an active layer coated on a surface of a diatomaceous earth, in order to prepare an efficient adsorbent (AsfNitro). Breakthrough experiments with benzene, pyridine, and 1-nitropropane revealed significant increase in adsorption...
-
Cyfrowy akcelerator wybranych modułów standardu kompresji wideo H.264
PublicationW komunikacie przedstawiono konfigurowalny cyfrowy akcelerator estymacji ruchu (motion estimation) przeznaczony dla enkodera wideo standardu H.264. Akcelerator został wstępnie zaimplementowany w układzie FPGA VIRTEX6-VLX365T, a następnie w układzie ASIC w technologii UMC 90 nm. Obie implementacje zostały zweryfikowane pozytywnie, a szczegółowe wyniki symulacji i pomiarów akceleratora ASIC zostały porównane z innymi dostępnymi w...
-
Productive aging
PublicationThe term “productive aging” refers to the participation of older adults in different activities that contribute to generating goods and services and develop the capacity to produce goods and services. In that sense, it includes both the economic activity of this group – serving in the paid workforce – and its social productivity, understood as volunteer activities (Bass et al. 1993). In the broader sense, “productive aging” can...
-
Uncertainty assessment of ultimate strength of corroded stiffened plates subjected to different maintenance actions
PublicationThe study deals with the uncertainty assessment of different governing factors related to the ultimate strength of the corroded stiffened plates. The load-carrying capacity is predicted with the use of the nonlinear Finite Element Method. The most influencing governing factors in the non-linear FE analysis, such as material properties and initial imperfections are modeled and analysed as stochastic variables. The ultimate strength...
-
Resonant DC link inverters for AC motor drive systems – critical evaluation
PublicationIn this survey paper, resonant and quasiresonant DC link inverters are reexamined for AC motor drive applications. Critical evaluation of representative topologies is based on simulation and waveform analysis to characterize current/voltage stress of components, control timing constraints and feasibility. A special concern over inverter common-mode voltage and voltage gradient du/dt limitation capacity is discussed for motor bearing...
-
The Role of Proteins in Food
PublicationThis chapter describes the effect of proteins on the sensory attributes and the biological value and safety of foods. The role of proteins depends on their amino acid composition and structure, on changes due to storage and processing, as well as on interactions with other food components. The effect on the sensory quality of foods is brought about by hydrophobicity, solubility, water holding capacity, gelling, film formation,...
-
Proof of Concept of Indoor Location System Using Long RFID Readers and Passive Tags
PublicationThe paper proposes a system for persons and objects location with the use of long radio-frequency identifications (RFIDs) readers. In order to investigate all aspects of the proposed location system, several key elements had to be analyzed, including the distance from which the tagged objects and the possibility of using more than one tag within one RFID range at the same time. When designing the system, it is also necessary to...
-
Superconducting properties and electronic structure of NaBi
PublicationResistivity, dc magnetization, and heat capacity measurements are reported for superconducting NaBi. Tc, the electronic contribution to the specific heat γ, the ΔCp/γTc ratio, and the Debye temperature are found to be 2.15 K, 3.4 mJ mol−1 K−2, 0.78, and 140 K respectively. The calculated electron–phonon coupling constant (λep = 0.62) implies that NaBi is a moderately coupled superconductor. The upper critical field and coherence...
-
ANALYSIS OF BRACE STIFFNESS INFLUENCE ON STABILITY OF THE TRUSS
PublicationThe paper is devoted to the numerical and experimental research of stability of a truss with side elastic supports at the top chord. The structure is a model of a real roof truss scaled by factor ¼. The linear buckling analysis and non-linear static analysis were carried out. The buckling length factor for the compressed top chord was calculated and the limit load for the imperfect truss shell model with respect to brace stiffness...
-
Experimental Study of Dapped-End Beams Subjected to Inclined Load
PublicationThis paper presents the results of an experimental investigation of the reinforced concrete (RC) dapped-end beams loaded with inclined forces, compared to identical ones loaded with vertical forces only. Such a load may occur in, for example, Gerber's joints or in dapped-end beams supported on corbels, where the vertical gravitation force is additionally completed with horizontal forces caused by temperature differences, shrinking,...
-
Experimental Tests Of Sandwich Beams In The Design Process Of GFRP Shell Footbridge Structure
PublicationThe paper includes selected aspects of the study to elaborate architectural, material and construction design of pedestrian footbridge spans made of composite materials. The considered footbridge is a sandwich-type shell structure. The cooperation of PET foam core with outer lining surfaces is crucial for its load bearing capacity. The paper is aimed to experimental investigation of sandwich beams subjected to bending loading....
-
New trends in development of micro heat exchangers for ORC's
PublicationIn the paper, new trends in development of micro heat exchangers for CHP are presented. Main attention is concentrated on the question, how channels size and thermal development lenght affect the heat transfer. New types of micro heat exchangers developed at the Institute of Fluid-Flow Machinery PAS and the methoda of their design are presented. The new experimental testing methods of the micro-channel heat exchangers, new algorithms...
-
Video traffic data - Interchange Piotrkow Trybunalski East (S8-12), weaving, Poland
Open Research DataThe data includes video traffic data registered with 2 video cameras at weaving area (weaving section type A) of the Piotrkow Trybunalski East interchange within S8 expressway in Poland (interchange of expressway S8 and national road 12), located in the Piotrkow Trybunalski area. The data covers the one day: 21.06.2017. (expressway S8).
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, bath simulation - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - buttocks electrodes, reinforcement 2x smaller, drl on knees - women
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Semantic Integration of Heterogeneous Recognition Systems
PublicationComputer perception of real-life situations is performed using a variety of recognition techniques, including video-based computer vision, biometric systems, RFID devices and others. The proliferation of recognition modules enables development of complex systems by integration of existing components, analogously to the Service Oriented Architecture technology. In the paper, we propose a method that enables integration of information...
-
ROAD SAFETY WITHIN THE "INTEGRATED SYSTEM OF TRANSPORT SAFETY"
PublicationThe concept of the “Integrated System of Transport Safety” in Poland is a novel solution, built upon the best practices available from only a handful of countries in the world. In the last few decades, the extent of applying integrated transport safety systems to improve transport safety systems has varied; nevertheless, studying the experience of the safest countries in the world we can say that enormous progress has been achieved...