Filters
total: 1486
displaying 1000 best results Help
Search results for: FAULT IDENTIFICATIONS
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublicationStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublicationIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
Noninvasive method for rotor fault diagnosis in inverter fed induction motor drive
PublicationThis article presents a proposal, simulation and experimental results of a noninvasive rotor fault diagnosis method for the inverter fed induction motor drive. Comparing to reported methods the proposed one does not require any load, rotor brake, slip, mechanical or electrical system physical modification e.g. machine disassembly and can be applied regardless the rotor speed measurement or estimation method.
-
Five-phase Induction Motor Drive Operation During Stator Phase Fault
PublicationThe article presents the most important advantages of multi-phase electric drives. The construction of a five-phase squirrel cage induction motor together with possible stator winding distribution cases is presented, which affect the properties of such motor. Increased reliability of five-phase drives was indicated. The drive operation properties were confirmed by experimental results.
-
Fault detection in the marine engine using a support vector data description method
PublicationFast detection and correct diagnosis of any engine condition changes are essential elements of safety andenvironmental protection. Many diagnostic algorithms significantly improve the detection of malfunctions.Studies on diagnostic methods are rarely reported and even less implemented in the marine engine industry.To fill this gap, this paper presents the Support Vector Data Description (SVDD) method as applied to thefault detection...
-
Improving sensitivity of residual current transformers to high frequency earth fault currents
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when high frequency earth fault current occurs. Serious hazard of electrocution exists then. In order to detect such a current, it is necessary to modify parameters of residual current devices, especially the operating point of their current transformer. The authors proposed...
-
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublicationDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Impact of DC fault blocking capability on the sizing of the DC-DC Modular Multilevel Converter
Publication -
Mechanical response of buried High-Density Polyethylene pipelines under normal fault motions
Publication -
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublicationThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data
Publication -
On Cointegration Analysis for Condition Monitoring and Fault Detection of Wind Turbines Using SCADA Data
Publication -
Energy quality improvement by ultra rapid L. V. fault current limiting andinterrupting.
PublicationPrzedstawiono możliwość ograniczania rozprzestrzeniania się zapadów napięcia w sieciach elektroenergetycznych przy zwarciach przez zastosowanie łączników hybrydowych do ultra szybkiego ograniczania i wyłączania prądów zwarciowych. Referat ma na celu przedstawienie dotychczasowych osiągnięć prac badawczych w dziedzinie łączników ultra szybkich, a także poznanie opinii elektroenergetyki i odbiorców na temat celowości wprowadzenia...
-
Sensorless algorithm for sustaining controllability of IPMSM drive in electric vehicle after resolver fault
PublicationThis paper presents a sensorless algorithm designated for the emergency control of an interior permanent magnet synchronous motor (IPMSM) drive in electric or hybrid vehicle. The algorithm is based on analysing the derivatives of motor phase currents measured over the duration of particular inverter states. The method is computationally simple and does not require additional hardware since the derivatives are measured indirectly....
-
The effect of the motor filters on earth fault current waveform in circuits with variable speed drives
PublicationIn circuits with variable speed drives distorted earth fault current flows. Earth fault current distortion influences the threshold of ventricular fibrillation. This paper presents earth fault current distortion in circuits with variable speed drives when motor filter is used. Two types of motor filter are analyzed. For every type of filter the effect of earth fault current distortion on ventricular fibrillation is evaluated.
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Dynamic Research of Masonry Vault in a Technical Scale
PublicationThe paper presents preliminary results of dynamic tests of the masonry barrel vault in a technical scale. Experimental studies are intended to identify material properties of homogenized masonry vaults under dynamic loads. The aim of the work is to create numerical models to analyse vault’s dynamic response to dynamic loads in a simplest and accurate way. The process of building the vault in a technical scale is presented in the...
-
Two‐functional μBIST for Testing and Self‐Diagnosis of Analog Circuits in Electronic Embedded Systems
PublicationThe paper concerns the testing of analog circuits and blocks in mixed‐signal Electronic Embedded Systems (EESs), using the Built‐in Self‐Test (BIST) technique. An integrated, two‐functional, embedded microtester (μBIST) based on reuse of signal blocks already present in an EES, such as microprocessors, memories, ADCs, DACs, is presented. The novelty of the μBIST solution is its extended functionality. It can perform 2 testing functions:...
-
Phenotypic and genotypic identification of atypical L. monocytogenes
Open Research DataThe data represent the results of research within the Miniatura 5 scientific activity entitled "Characterization of atypical Listeria monocytogenes strains isolated from the food production environment financed by the National Science Center (no. DEC 2021/05/X/NZ9/00143). The aim of this part of the project was (i) to learn about the differences between...
-
Fast Real-Time RDFT- and GDFT-Based Direct Fault Diagnosis of Induction Motor Drive
PublicationThis paper presents the theoretical analysis and experimental verification of a direct fault harmonic identification approach in a converter-fed electric drive for automated diagnosis purposes. On the basis of the analytical model of the proposed real-time direct fault diagnosis, the fault-related harmonic component is calculated using recursive DFT (RDFT) and Goertzel DFT (GDFT), applied instead of the full spectrum calculations...
-
Elimination of the negative effect of earth fault current higher frequency on tripping of residual current devices
PublicationCzęstotliwość prądu różnicowego większa niż 50/60 Hz ma niekorzystny wpływ na wyzwalanie wyłączników różnicowoprądowych. Przy zwiększonej częstotliwości prądu różnicowego rzeczywisty prąd zadziałania wyłączników zwiększa się, a niektóre z nich w ogóle nie wyzwalają. W artykule omówiono główne przyczyny zwiększenia się prądu zadziałania wyłączników różnicowoprądowych oraz przedstawiono sposób eliminacji niekorzystnego wpływu zwiększonej...
-
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publication -
Fault diagnosis in electronic circuits based on bilinear transformation in 3-D and 4-D spaces
PublicationPrzedstawiono ideę nowych metod diagnostycznych 3-D i 4-D opartych na przek-ształceniu biliniowym. Metody te bazują na transformacjach operujących odpo-wiednio w trzy i czterowymiarowych przestrzeniach funkcji układowych. Dlatych metod omówiono algorytm lokalizacji i identyfikacji pojedynczych uszko-dzeń parametrycznych w liniowych układach elektronicznych oraz algorytm lo-kalizacji i identyfikacji pojedynczych uszkodzeń...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublicationFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Novel Investigation of Higher Order Spectral Technologies for Fault Diagnosis of Motor-Based Rotating Machinery
PublicationIn the last decade, research centered around the fault diagnosis of rotating machinery using non-contact techniques has been significantly on the rise. For the first time worldwide, innovative techniques for the diagnosis of rotating machinery, based on electrical motors, including generic, nonlinear, higher-order cross-correlations of spectral moduli of the third and fourth order (CCSM3 and CCSM4, respectively), have been comprehensively...
-
Damage identification by wavelet analysis
PublicationW pracy omówiono metodę identyfikacji rodzaju nieciagłości w 1 wymiarowych elementach konstrukcji wykorzystującą pomiar propagacji fali sprężystej i jej analizę metodą transformacji falkowej.
-
Damage identification by wavelet analysis
Publication -
The Methods for RTS Noise Identification
PublicationIn the paper authors present two methods, which allows to identify the RTS noise in noise signal of semiconductor devices. The first one was elaborated to identify the RTS noise and also to estimate the number of its levels. The second one can be used to estimate all of the parameters of Gaussian and non-Gaussian components in the noise signal in a frequency domain.
-
International Journal of Radio Frequency Identification Technology and Applications
Journals -
Data-driven models for fault detection using kernel PCA: A water distribution system case study
Publication -
Using a square-wave signal for fault diagnosis of analog parts of mixed-signal electronic embedded systems
PublicationArtykuł przedstawia nowe podejście do detekcji i lokalizacji pojedynczych katastroficznych i parametrycznych uszkodzeń części analogowych w mieszanych sygnałowo elektronicznych systemach wbudowanych. Podejście składa się z trzech etapów: tworzenia słownika uszkodzeń na podstawie krzywych identyfikacyjnych, etapu pomiarowego w którym układ badany pobudzany jest falą prostokątną generowaną przez mikrokontroler a odpowiedź jest próbkowana...
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublicationIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Data-driven models for fault detection using kernel pca:a water distribution system case study
PublicationKernel Principal Component Analysis (KPCA), an example of machine learning, can be considered a non-linear extension of the PCA method. While various applications of KPCA are known, this paper explores the possibility to use it for building a data-driven model of a non-linear system-the water distribution system of the Chojnice town (Poland). This model is utilised for fault detection with the emphasis on water leakage detection....
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublicationThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Expert opinion on the effectiveness of protection against electric shock in case of fault in an installation for electric vehicles charging
PublicationThe opinion concerns the use of residual current devices for protection against electric shock by automatic disconnection of supply in a Norwegian installation intended for charging of electric vehicles.
-
Identification of Optocoupler Devices with RTS Noise
PublicationThe results of noise measurements in low frequency range for CNY 17 type optocouplers are presented. The research were carried out on devices with different values of Current Transfer Ratio (CTR). The methods for identification of Random Telegraph Signal (RTS) in noise signal of optocouplers were proposed. It was found that the Noise Scattering Pattern method (NSP method) enables to identify RTS noise as non-Gaussian component...
-
Optimal inputs in pharmacokinetics model's identification
PublicationW pracy przedstawiono zagadnienie optymalizacji pobudzeń dla identyfikacji parametrycznej kompartmentowych modeli zmiennych stanu SISO systemów farmakokinetycznych. Zaimplementowano kryterium w postaci śladu macierzy informacyjnej Fishera (kryterium czułościowe). Rozważono klasę pobudzeń dopuszczalnych o ograniczonej energii, gdyż w przypadku wielu leków zbyt szybkie ich podawanie wiąże się z występowaniem skutków ubocznych. Zadanie...
-
PCR test for Microsporum canis identification
PublicationMicrosporum canis, for which the natural hosts are cats and dogs, is the most prevalent zoophilic agent causing tinea capitis and tinea corporis in humans. We present here a diagnostic PCR test for M. canis, since its detection and species identification is relevant to the choice of treatment and to the understanding of a probable source of infection. An M. canis-specific PCR was evaluated using 130 clinical isolates of dermatophytes...
-
A service-oriented approach to the identification of IT Risk
PublicationArtykuł przedstawia ogólne podejście do identyfikacji ryzyka eksploatacji systemów informatycznych, które obejmuje bezpieczeństwo, ochronę, prywatność oraz uzależnienie. Podejście oparte jest na badaniu trybów awarii usług dostarczanych użytkownikom przez oprogramowanie. Identyfikacja ryzyka na podstawie przeglądu usług uzupełniana jest listami kontrolnymi wyprowadzonymi ze standardów, a także klasycznymi technikami analizy bezpieczeństwa...
-
Risk Identification Patterns for Software Projects.
PublicationArtykuł prezentuje metodę identyfikacji ryzyka w projektach informatycznych z użyciem wzorców ryzyka odnoszących się do modelu procesu projektowego. W artykule zdefiniowano meta-model dla modelowania procesów ukierunkowany na analizę ryzyka oraz proste i złożone wzorce ryzyka wywiedzione z tego meta-modelu, jak również pokazano przykładowe użycie wzorców do opisu czynników ryzyka odnoszących się do modelu RUP. Metodę poddano walidacji...
-
Simulation and identification of damage in bar structures.
PublicationPraca zawiera opis i testy 3 procedur badawczych dotyczących lokalizacjizniszczeń w konstrukcjach. Procedury bazują na danych modalnych jakie obiektgeneruje podczas swoich drgań tzn. częstościach własnych i postaciach drgań Badane są zmiany podatności układu, zmiany krzywizn postaci drgań i wrażli-wość częstości na założone zniszczenia. Odpowiednie procedury wiążące się ztymi trzema metodami są przestestowane na przykładzie wspornika...
-
A procedure for elastoplastic hardening function identification.
PublicationThe inverse analysis method for identifying a nonlinear hardening function,which governs a plastic yielding of soil and rock materials in the framework of elastoplastic theory is presented. A concept of two stage finite element based on spatial discretization of computational space and hardening function space is introduced. The proposed inverse analysis can be classified as the output least squares method. The Levenberg Marquard...
-
Simulation and measurements for the substance identification by AFM
Publication -
On noncausal identification of nonstationary stochastic systems
PublicationIn this paper we consider the problem of noncausal identification of nonstationary,linear stochastic systems, i.e., identification based on prerecorded input/output data. We show how several competing weighted least squares parameter smoothers, differing in memory settings, can be combined together to yield a better and more reliable smoothing algorithm. The resulting parallel estimation scheme automatically adjusts its smoothing...
-
The consideration to the dynamic systems parameter identification
PublicationIn this paper, a concept for continuous-time dynamic systems parameter identification using modulating function approach is presented. It refers to linear as well as selected non-linear systems. It shows the possibility of direct application without converting differential equation. In particular cases direct application can decrease the amount of computation in non-linear system identification, which generally requires Fourier...