displaying 1000 best results Help
Search results for: PASSIVE SAMPLERS
-
Experimental Evaluation of ND: YAG Laser Parameters and Sample Preparation Methods for Texturing Thin AISI 316L Steel Samples
Publication -
Experimental Evaluation of ND: YAG Laser Parameters and Sample Preparation Methods for Texturing Thin AISI 316L Steel Samples
PublicationIn mechanical and material engineering, the effect of laser texturing depends on many factors besides device specification, primarily the properties of the materials being processed, and, secondly, the preparation of the sample. Laser texturing of thin (<5 mm) samples is mostly performed utilizing short-pulse lasers, but depending on the power of the laser beam, the process can also be performed by using continuous operation lasers....
-
Acoustic signal processing in passive sonar system with towed array
PublicationW referacie opisano przetwarzanie sygnałów akustycznych w pasywnym systemie hydrolokacyjnym. W pojęciu ''przetwarzanie sygnałów akustycznych'' mieszczą się wszelkie operacje wykonywane na sygnałach analogowych tj. wzmacnianie, filtracja i próbkowanie, jak również operacje na sygnałach cyfrowych uzyskanych w procesie próbkowania. Do operacji cyfrowych wykonywanych w systemie zalicza się synchronizację, konwersję, sortowanie, wytwarzanie...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
Publication -
Rehabilitation device supporting active and passive upper limb exercises
PublicationThis article presents a mechatronic solution for rehabilitation devices supporting active and passive exercises in persons with motor dysfunctions of the upper limbs in the area of the elbow and shoulder joints. A planar positioner integrated with original software and a control system, served as the basis for creating the present solution. Bellman’s programming method was applied to optimize the motion trajectory of the planar...
-
Influence of passive house technology on time and cost of construction investment
PublicationDue to the changes in the energy standards for housing in Poland there are many concerns. Is the standard required by the regulation achievable and if it is, then at what cost? There are many solutions to construct a building in line with the requirements of passive house technology. They are differentiated by price and time required for implementation. This study is based on the solution proposed by one of Polish companies, offering...
-
Measurement of benzene concentration in urban air using passive sampling
PublicationAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Cheap Cancellation of Strong Echoes for Digital Passive and Noise Radars
PublicationThe problem of cancellation of strong, potentially nonstationary,echoes in noise radars and passive radars utilizing digitaltransmissions is considered. The proposed solution is a multi-stage procedure.Initial clutter estimates, obtained using the least mean squares(LMS) algorithm, are refined using specially designed filters, "matched"to spectral densities of targets and clutter. When the postprocessing filtersare noncausal, the...
-
Buck-Boost Inverters with Symmetrical Passive Four-terminal Networks
PublicationAlternating Voltage Inverters (Converters) supplied by low-voltage sources DC (ex. fuel cell, photovoltaic cell) are most frequently realized on the basis of the three fundamental topologies: a) PWM voltage inverter with boost-converter" system, b) PWM voltage inverter with transformed converter DC/DC in the ,,boost-converter" system, c) PWM current converter. However none of these solutions is claimed to be the best and dominant...
-
Permeation passive sampling as a tool for the evaluation of indoor air quality
PublicationOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.
-
Influence of the initial void ratio on the evolution of the passive earth pressure
PublicationW artykule przedstawiono wyniki numerycznej analizy wpływu rozkładu początkowego wskaźnika porowatości i fluktuacji bieżącego wskaźnika porowatości w materiałach granulowanych na powstawanie lokalizacji odkształceń. Obliczenia wykonano dla ściskania dwuosiowego stosując metodę elementów skończonych na bazie mikropolarnego prawa hipoplastycznego.
-
East-West Cultural Passage
Journals -
Universal software radio peripheral as a receiver and DSP platform for a passive radar
Publication -
Passive sampling as a tool for obtaining reliable analyticalinformation in environmental quality monitoring
PublicationSpośród technik pobierania próbek analitów technika dozymetrii pasywnej wydaje się być interesującą alternatywą w stosunku do powszechnie stosowanych technik dynamicznych. Dozymetria pasywna łączy w sobie etap pobierania próbki z etapem izolacji i wzbogacania analitów, które są zatrzymywane w odpowiednim medium zatrzymującym. Prowadzi to do znacznego uproszczenia operacji analitycznych wykonywanych in situ. W odróżnieniu od aktywnych...
-
Selection of measurement frequency in Mott–Schottky analysis of passive layer on nickel
Publication -
Investigations of the passive layer cracking by means of Dynamic Electrochemical Impedance Spectroscopy
Publication -
Modeling of Passive and Forced Convection Heat Transfer in Channels with Rib Turbulators
PublicationThe main goal of the research presented in this paper was the experimental and numerical analysis of heat enhancement and aerodynamic phenomena during air flow in a channel equipped with flow turbulators in the form of properly configured ribs. The use of ribs intensifies the heat transfer and at the same time increases not only the flow resistance but also the energy costs. Therefore, designing modern heat exchangers with optimal...
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublicationThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Bayesian Optimization for solving high-frequency passive component design problems
PublicationIn this paper, the performance of the Bayesian Optimization (BO) technique applied to various problems of microwave engineering is studied. Bayesian optimization is a novel, non-deterministic, global optimization scheme that uses machine learning to solve complex optimization problems. However, each new optimization scheme needs to be evaluated to find its best application niche, as there is no universal technique that suits all...
-
Influence of initial density of cohesionless soil on evolution of passive earth pressure
PublicationArtykuł porusza problem odporu bezkohezyjnego gruntu. Obliczenia wykonano wykorzystując metodę elementów skończonych na bazie mikropolarnego prawa hipolastycznego. W obliczeniach przyjęto różne początkowe zagęszczenia oraz średnice cząstek gruntu.
-
The external walls of a passive building: A classification anddescription of their thermal and optical properties
PublicationThis paper attempts a new classification of insulating materials from the perspective of their utility in thepro-ecological passive construction industry. The main criterion is the conductivity of thermal and solarenergy. Based on their ability to conduct or block fluxes of thermal and solar energy, six types of insulatingwalls are proposed. On the basis of this criterion there are traditional dividing walls (typical walls, wallinsulating...
-
Bearing estimation using double frequency reassignment for a linear passive array
PublicationThe paper demonstrates the use of frequency reassignment for bearing estimation. For this task, signals derived from a linear equispaced passive array are used. The presented method makes use of Fourier transformation based spatial spectrum estimation. It is further developed through the application of two-dimensional reassignment, which leads to obtaining highly concentrated energy distributions in the joint frequency-angle domain...
-
Influence of the femoral offset on the muscles passive resistance in total hip arthroplasty
PublicationBackground Soft tissue tension is treated as a crucial factor influencing the post-THA dislocation. The femoral offset is regarded as one of the major parameters responsible for the stabilization of the prosthesis. It is unclear which soft tissue is mostly affected by the offset changes. Methods A finite element model of the hip was created. The model comprised muscles, bones, a stem, the acetabular component and a liner. The muscles...
-
Selection of measurement frequency in Mott-Schottky analysis of passive layer on nickel
PublicationPrzedstawiono zależności Mott'a - Schottky'ego dla różnych częstotliwości pomiarowych. Kształt uzyskanych zależności zależy od doboru tych częstotliwości. Związane jest to z tym, że stężenie defektów w warstwie pasywnej zależy od doboru częstotliwości. Metoda DEIS pozwala na uniknięcie tych niedogodności.
-
Investigations of the passive layer cracking by means of dynamic electrochemical impedance spectroscopy.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna została wykorzystana do badania pękania warstwy pasywnej na austenitycznej stali wysokostopowej.Zbadano efekt narzuconego potencjału oraz naprężeń rozciągających na pękanie korozyjne stali wysokostopowej 304L w środowisku 0.5M NaCl w temperaturze pokojowej. Praca przedstawia chwilowe widma impedancyjne uzyskane dla badanego układu przy różnych wartościach potencjałów. Uzyskane...
-
Some aspects of vibration control. Part I: Active and passive correction.
PublicationPrzedstawiono ogólne podejście do modyfikacji układu mechanicznego w ruchu harmonicznym przy użyciu aktywnych i pasywnych metod. Zaproponowano metodę wyznaczania elementów macierzy układu lub struktury i nastaw regulatora, zapewniającą najefektywniejsze oddziaływanie na dynamikę ruchu.
-
Massive surveillance data processing with supercomputing cluster
PublicationIn recent years, increasingly complex algorithms for automated analysis of surveillance data are being developed. The rapid growth in the number of monitoring installations and higher expectations of the quality parameters of the captured data result in an enormous computational cost of analyzing the massive volume of data. In this paper a new model of online processing of surveillance data streams is proposed, which assumes the...
-
Ionic liquids for the passive sampling of sulfonamides from water—applicability and selectivity study
Publication -
Salinity and pH as factors affecting the passive sampling and extraction of pharmaceuticals from water
Publication -
Application of passive acoustic radar to automatic localization, tracking and classification of sound sources
PublicationA concept, practical realization and applications of the passive acoustic radar to automatic localization, tracking and classification of sound sources were presented in the paper. The device consists of a new kind of multichannel miniature sound intensity sensors and a group of digital signal processing algorithms. Contrary to active radars, it does not emit the scanning beam but after receiving surrounding sounds it provides...
-
The effects of short-term passive smoke exposure on endothelium-dependent and independent vasodilation
Publication -
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublicationTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
Planning a Cost-Effective Delay-Constrained Passive Optical Network for 5G Fronthaul
PublicationWith the rapid growth in the telecommunications industry moving towards 5G and beyond (5GB) and the emergence of data-hungry and time-sensitive applications, Mobile Network Operators (MNOs) are faced with a considerable challenge to keep up with these new demands. Cloud radio access network (CRAN) has emerged as a cost-effective architecture that improves 5GB performance. The fronthaul segment of the CRAN necessitates a high-capacity...
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublicationThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
THE SYNCHROSQUEEZING METHOD IN BEARING ESTIMATION OF STATIONARY SIGNALS FOR PASSIVE SONAR WITH TOWED ARRAY
PublicationIn this paper, a novel method of bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of bearing estimation based on the spatial spectrum [1] is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. [2]. Using this method leads to a precise bearing estimation. The proposed method requires a relatively small amount of computation,...
-
Experimental Designs of Mass Customized Passive Single-family Houses - Prospects and Limitations
PublicationAbstract The article deals with case studies of selected architectural designs of the past fifteen years the authors of which intended to rethink both the typology and the means of constructing single family houses. The analysis covers contemporary design issues such as variation, curvilinearity, customization, digital manufacturing and ecological concerns. The purpose behind the research was to establish in what way new design...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublicationAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Expedited Optimization of Passive Microwave Devices Using Gradient Search and Principal Directions
PublicationOver the recent years, utilization of numerical optimization techniques has become ubiquitous in the design of high-frequency systems, including microwave passive components. The primary reason is that the circuits become increasingly complex to meet ever growing performance demands concerning their electrical performance, additional functionalities, as well as miniaturization. Nonetheless, as reliable evaluation of microwave device...
-
Measurements of passive components using of an IEEE 1149.4 mixed-signal test bus
PublicationW pracy przedstawiono wyniki badań nad wykorzystaniem magistrali testującej mieszanej sygnałowo IEEE 1149.4 do pomiarów elementów pasywnych zamontowanych na pakietach elektronicznych. Do badań użyto wyposażonych w magistralę układów scalonych typu STA400. Zaprezentowano metody pomiaru rezystancji pojedynczych elementów z wykorzystaniem źródła prądowego oraz źródła VH znajdującego się w analogowych modułach ABM układu STA400. Pokazano...
-
Impedance investigation of passive 304 stainless steel in the pit pre-initiation state
PublicationZaprezentowano wyniki badań impedancyjnych stali stopowej 304L metodą klasycznej EIS i dynamicznej EIS. Badania związane były z przejściem stali stopowej ze stanu pasywnego do inicjacji powstawania wżerów. Na podstawie zmian parametrów elektrycznego schematu zastępczego stwierdzono, że najbardziej prawdopodobnym mechanizmem tworzenia się wżerów jest model zniszczenia (pęknięcia) warstwy pasywnej.
-
Globalized Parametric Optimization of Microwave Passive Components Using Simplex-Based Surrogates
PublicationOptimization-based parameter adjustment involving full-wave electromagnetic (EM) simulation models is a crucial stage of present-day microwave design process. In fact, rigorous optimization is the only reliable mean permitting to simultaneously handle multiple geometry/material parameters, objectives, and constraints. Unfortunately, EM-driven design is a computationally intensive endeavor. While local tuning is usually manageable,...
-
Passage: Tidskrift for litteratur og kritik
Journals -
Preservation and Storage of Water Samples
PublicationOpisano metody utrwalania i przechowywanie próbek wody w celu oznaczenia zwiazków nieorganicznych, przedyskutowano wady i zalety poszczególnych metod. Omówiono utrwalanie i przechowywanie próbek wody przed wykonaniem analizy specjacyjnej związków arsenu, chromu, rteci, selenu i cyny. Omówiono również utrwalanie i przechowywanie próbek wody przy oznaczaniu związków organicznych.
-
Preservation and storage of water samples
PublicationOd momentu pobrania próbki do wykonania tej analizy wody mogą zmieniać swoje właściwości na skutek zachodzących w nich procesów chemicznych, fizycznych, czy też biologicznych. W pracy omówiono zmiany mogące zachodzić w próbkach wodnych oraz przyczyny ich występowania. Szczególną uwagę zwrócono na reakcje chemiczne, procesy fizykochemiczne, reakcje biochemiczne i fotochemiczne. Przedstawiono również techniki konserwacji próbek wód...
-
Clozapine-induced massive hematemesis: A rare case report
Publication -
Tryton Supercomputer Capabilities for Analysis of Massive Data Streams
PublicationThe recently deployed supercomputer Tryton, located in the Academic Computer Center of Gdansk University of Technology, provides great means for massive parallel processing. Moreover, the status of the Center as one of the main network nodes in the PIONIER network enables the fast and reliable transfer of data produced by miscellaneous devices scattered in the area of the whole country. The typical examples of such data are streams...
-
Fundamentals of Communication Networks Resilience to Disasters and Massive Disruptions
PublicationCommunication networks are exposed to a variety of massive failure events following from activities of nature, weather-induced disruptions, technology-implied problems, and malicious human activities. In this chapter, we first highlight the characteristics of these scenarios and discuss example failure events reported during the last three decades. Next, we explain the concept of network resilience and present an overview of major...
-
Resilience of 5G Mobile Communication Systems to Massive Disruptions
PublicationThis chapter discusses vital techniques to enhance the resilience of 5G systems. It starts with dependability assessment of 5G networks. Next, it describes (a) the frequency fallback technique to improve availability and survivability of 5G services, (b) segment interleaving scheme to enhance communications resilience between base stations and the remaining part of the network and (c) multi-operator protection to address the resilience...
-
Massive Open Online Courses: strategies and research areas
PublicationThe latest education revolution, the massive open online courses (MOOCs), is gaining momentum, accolades, and participation across industry and academia. These learning laboratory behemoths host and assess tens to hundreds of thousands of students in a single class, for free. Similar to their scope, MOOCs’ short- and long-term educational implications seem massive. Immediate MOOC educational outcomes vary widely from roaring successes...