Search results for: GASTROESOPHAGEAL IMPEDANCE
-
Ellipse-fitting algorithm implementation in the impedance measurement system based on DAQ card with FPGA
PublicationThe paper presents an implementation of the ellipse-fitting algorithm in the impedance measurement system based on DAQ card equipped with FPGA chip. The method implementation was tested by simulation means as well as experimentally in the designed and presented measurement system. Finally, the limit values of sampling parameters which assures satisfying accuracy were given.
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublicationThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublicationThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Rapid multi-objective design optimization of miniaturized impedance transformer by Pareto front exploration
PublicationFast multi-objective optimization of compact impedance transformer is discussed. A set of alternative designs representing possible trade-offs between conflicting design criteria, i.e., electrical performance (here, wideband matching) and the structure size, is obtained through Pareto front exploration by means of surrogate-assisted methods.
-
Impedance Measurement and Selection of Electrochemical Equivalent Circuit of a Working PEM Fuel Cell Cathode
PublicationThe dynamic impedance analysis of direct methanolfuel cell (DMFC) cathode supplied with pure oxygen is pre-sented. Presented results were obtained during dynamic chang-es of the current density in working fuel cell. Investigation ofthe occurring processes at cathode was carried with dynamicelectrochemical impedance spectroscopy (DEIS). A discussionwas conducted based on the determined correlation parameterχ2. It was shown that...
-
Impedance monitoring of corrosion degradation of plasma electrolytic oxidation coatings (PEO) on magnesium alloy
PublicationImpedance technique based on continuous multisinusoidal current perturbation was used to explain degradation process of plasma electrolytic oxidation coatings (PEO) on magnesium alloy. An obtained impedance spectrum was fitted by electrical equivalent circuit to describe properties of conversion layer on magnesium alloy. Additionally, galvanostatic mode maintained during experiment, with DC current equal to zero, allowed to achieve...
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Evaluating the performance of organic coatings under mechanical stress using electrochemical impedance spectroscopy
PublicationMimo, iż znaczna liczba konstrukcji zabezpieczanych przy pomocy powłok poddawana jest cyklicznym naprężeniom mechanicznym, czynnik ten wydaje się być niedoceniany jako przyczyniający się do przyspieszonego niszczenia organicznych układów powłokowych. Celem pracy było zweryfikowanie czy powtarzające się naprężenia mechaniczne stanowią istotny element wpływający na skrócenie czasu eksploatacji systemów powłokowych. W tym celu układ:...
-
Using impedance spectroscopy to characterize and monitor protection aspects of organic coating systems on metal
PublicationOrganiczne powłoki ochronne stosowane są powszechnie do ochrony konstrukcji metalowych przed korozją i zużyciem mechanicznym. W pracy zaproponowano nowy typ sensora impedancyjnego, który może być zastosowany do ciągłej oceny właściwości barierowych i adhezyjnych systemów powłokowych w warunkach terenowych w sposób nieniszczący, bez konieczności stosowania naczyń z elektrolitem. Przedstawiono koncepcję czujnika oraz przykładowe...
-
Application of quartz crystal microbalance and dynamic impedance spectroscopy to the study of copper corrosion inhibitors
PublicationThe study investigates the application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) and Electrochemical Quartz Crystal Microbalance (EQCM) techniques to examine the corrosion inhibition of copper by Benzotriazole and Sodium Folate in a 0.1 M NaCl solution. DEIS, an advanced version of Electrochemical Impedance Spectroscopy (EIS), allows for real-time monitoring of non-stationary electrochemical systems,...
-
Application of the short time Fourier transformation to the continuous frequency method of measurement of electrode impedance
PublicationPrzedstawiona została nowa metoda pomiaru impedancji elektrodowej. Wykorzystuje ona jako pobudzenie niestacjonarny sygnał napięciowy, którego częstotliwość jest liniową funkcją czasu. Zastosowanie transformacji STFT do analizy napięciowego sygnału pobudzenia i odpowiedzi prądowej umożliwia wyznaczenie widma impedancyjnego. Dokładność otrzymywanych wartości impedancji uwarunkowana jest wielkością okna i zastosowanej funkcji analizującej.
-
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublicationThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
Dynamic impedance measurements of the Direct Methanol Fuel Cell cathode at various operating temperatures
PublicationThis article discusses the application of impedance analysis for diagnosing the cathode of a direct methanol fuel cell at various operating temperatures. The Dynamic Electrochemical Impedance Spectroscopy technique coupled with a linear current scan was applied for this purpose. This technique allowed the observation of changes in the cathode's properties in the fuel cell operating under real working conditions. An equivalent model...
-
The Application of Dynamic Electrochemical Impedance Spectroscopy (DEIS) Technique in Corrosion and Corrosion Inhibition Studies
Publicationorrosion studies have attracted considerable interest in the areas of materials chemistry and industrial chemistry, as it affects the direct and indirect costs of industry, leading to huge economic setbacks due to the need for repair, maintenance, and even shutdowns due corrosion damage. This new volume is a comprehensive resource that presents new and up-to-date, theoretical, and experimental corrosion inhibition studies.
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublicationThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Metody wyznaczania rezystancji i impedancji uziemień
PublicationPodstawowym parametrem charakteryzującym skuteczność działania uziemienia jest jego rezystancja, a dla uziemień odgromowych rezystancja udarowa. W artykule przedstawiono metody statyczne, wysokoczęstotliwościowe oraz udarowe wyznaczania właściwości uziemień.
-
Przenośny analizator impedancji z detektorem fazoczułym
PublicationW artykule przedstawiono prototyp analizatora impedancji, w którym zastosowano dwa mikrosystemy AD5933 do wydzielania składowych ortogonalnych sygnałów pomiarowych w zakresie częstotliwości od 0,01 Hz do 1 kHz i detektory fazoczułe dla częstotliwości z przedziału 1 kHz ÷ 100 kHz. Przyjęte rozwiązanie pozwoliło wyeliminować błędy pomiaru argumentu impedancji wprowadzane przez AD5933 w górnym zakresie częstotliwości. Uzyskany błąd...
-
Pomiary impedancji (rezystancji) udarowej uziemień odgromowych
PublicationOpisano najczęściej stosowane odmiany metod pomiaru rezystancji statycznej iimpedancji udarowej uziemień odgromowych.
-
Dynamic electrochemical impedance spectroscopy of the adsorption and relaxation of polyaniline chains during potentiodynamic redox transformations
Publication -
Impedance spectroscopy of BaTiO3 cubes suspended in lossy liquids as a physical model of two-phase system
PublicationTechniki spektroskopii impedancyjnej zostały wykorzystane do analizy modelu fizycznego w układzie dwufazowym w celu wyznaczanie stałej dielektrycznej dielektryka umieszczonego w cieczy. Badania eksperymentalne przeprowadzono z użyciem BaTiO3 jako materiału dielektrycznego, który został przygotowany jako kostki o jednakowej wielkości 2x2x1 mm3.
-
Enhanced capacitance of composite TiO2 nanotube / boron-doped diamond electrodes studied by impedance spectroscopy
PublicationWe report on the novel composite nanostructures based on boron-doped diamond thin film grown on top of TiO2 nanotubes. The nanostructures made of BDD-modified titania nanotubes showed an increase in activity and performance when used as electrodes in electrochemical environments. The BDD thin films (~200-500 nm) were deposited using microwave plasma assisted chemical vapor deposition (MW PA CVD) onto anodically fabricated TiO2...
-
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublicationOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses
Publication -
Dynamic electrochemical impedance spectroscopy of the adsorption and relaxation of polianiline chains during potentiodynamic redox transformations
PublicationZaprezentowano nowe podejście do analizy widm impedancyjnych uzyskanych dla warstwy przewodzącej polianiliny (PAni). Właściwości powyższej warstwy są często modelowane przy użyciu elementu stałofazowego (CPE), który w sposób dokładniejszy odzwierciedla wyniki eksperymentalne niż klasyczny element pojemnościowy (kondensator). W pracy zaproponowano nowy elektryczny obwód zastępczy oparty na modelu adsorpcyjnym Frumkin-Melik-Gaikazyan,...
-
On deterministic procedures for low-cost multi-objective design optimization of miniaturized impedance matching transformers
PublicationPurpose This paper aims to investigate deterministic strategies for low-cost multi-objective design optimization of compact microwave structures, specifically, impedance matching transformers. The considered methods involve surrogate modeling techniques and variable-fidelity electromagnetic (EM) simulations. In contrary to majority of conventional approaches, they do not rely on population-based metaheuristics, which permit lowering...
-
Study of Direct Methanol Fuel Cell Process Dynamics Using Dynamic Electrochemical Impedance Spectroscopy
PublicationA new technique, which was developed to characterize the direct methanol fuel cell under work conditions, has been presented in this paper. The impedance measurements were made using dynamic electrochemical impedance spectroscopy research technique in the galvanostatic mode, using multiple sinusoidal excitation. Obtained results show, that together with an increase of the temperature and working load, the global impedance...
-
Development of the Mobile PoC Graphene-Based Biosensing Device Using Electrochemical Impedance Spectroscopy (EIS)
Publication -
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublicationWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
Enhanced capacitance of composite TiO2 nanotube/boron-doped diamond electrodes studied by impedance spectroscopy
Publication -
Dynamic elektrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna elektrochemiczna spektroskopia impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Dynamic electrochemical impedance spectroscopy measurements of passive layer cracking under static tensile stresses.
PublicationDynamiczna Elektrochemiczna Spektroskopia Impedancyjna umożliwia badanie podatności i odporności korozyjnej różnych materiałów konstrukcyjnych, a w szczególności określenie właściwości elektrochemicznych warstw pasywnych występujących na ich powierzchni. W wielu przypadkach pęknięcie warstwy pasywnej pod wpływem działania naprężeń rozciągających prowadzi do korozji naprężeniowej. Z tego względu badania pękania warstw pasywnych...
-
Electrochemical behaviour of Cr coating in acidic sulphate solution studied by cyclic polarization and impedance spectroscopy
PublicationOdporność korozyjną powłok chromowych w 0.01 M H2SO4 zbadano metodami woltamperometrii cyklicznej i spektroskopii impedancyjnej. Stwierdzono, że właściwości ochronne powłoki chromowej w kontakcie z powietrzem wzrastają dzięki tworzeniu się warstwy tlenkowej zapełniającej defekty w powłoce. W trakcie polaryzacji anodowej następuje częściowe roztwarzanie tej warstwy i penetracja agresywnego środowiska do podłoża (stali), co powoduje...
-
Surrogate modeling of impedance matching transformers by means of variable‐fidelity electromagnetic simulations and nested cokriging
PublicationAccurate performance evaluation of microwave components can be carried out using full‐wave electromagnetic (EM) simulation tools, routinely employed for circuit verification but also in the design process itself. Unfortunately, the computational cost of EM‐driven design may be high. This is especially pertinent to tasks entailing considerable number of simulations (eg, parametric optimization, statistical analysis). A possible...
-
The non-invasive evaluation of heart function in patients with an acute myocardial infarction: The role of impedance cardiography
PublicationBackground: The purpose of this study was to analyze hemodynamic changes in patients treated with percutaneous coronary intervention (PCI) at an early stage of acute myocardial infarction (AMI) and at one-month follow-up. Methods: Patients with AMI (n = 27) who underwent PCI were analyzed using impedance cardiography (ICG). ICG data were collected continuously (beat by beat) during the whole PCI procedure and thereafter at every...
-
Impedance spectroscopy studies on hybrid materials consisting of poly(3,4-ethylenedioxythiophene) and iron, cobalt and nickel hexacyanoferrate
PublicationBadania warstw polimeru pEDOT modyfikowanego heksacyjanożelazianami żelaza, kobaltu i niklu przeprowadzono za pomocą spektroskopii impedancyjnej (SI). Wykazano, że materiały hybrydowe charakteryzują się dobrą stabilnością. Warstwy testowano w zakresie temperatur od 283 do 313K. w kontakcie z wodnym roztworem KCl. Wysokie współczynniki dyfuzji wskazują na możliwości wykorzystania układów jako przewodników jonowych.
-
The impedance method of monitoring the degradation of rubber linings in applications where progressive deterioration is the predominant failure mechanism
Publication -
Evaluation of cavitation erosion–corrosion degradation of mild steel by means of dynamic impedance spectroscopy in galvanostatic mode
Publication -
The fixed state in impedance measurements of a two-step electrode reaction proceeding with accompanying adsorption of an intermediate product
Publication -
Instantaneous impedance monitoring of AA 7075 aluminum alloy corrosion in borate buffer with admixed chloride ions
PublicationThe study presents a research capabilities of Dynamic Electrochemical Impedance Spectroscopy (DEIS) as a tool used for instantaneous on-line monitoring of corrosion processes on the example of AA 7075 aluminum alloy. A borate buffer with admixed chloride ions in a quantity ranging from 0.05 to 25 mM was used to represent different types of corrosion attack. The surface of samples specimens was evaluated before and after the tests...
-
Instantaneous Impedance Analysis of Non-Stationary Corrosion Process: a Case Study of Carbon Steel in 1M HCl
PublicationThe paper concerns the problem of evaluation of stationarity of carbon steel corrosion in 1M HCl. Comparison of corrosion rate with addition of corrosion inhibitor to the reference measurement is the most often used way of evaluating inhibitor efficiency. Such an approach is valid only if corrosion rate is a stationary process. Two complementary techniques were used simultaneously: volumetric analysis of evolved hydrogen and instantaneous...
-
Electrochemical properties of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes in solid oxide cells: Impedance study of symmetrical electrodes
PublicationThis work evaluates porous Sr0.86Ti0.65Fe0.35O3 (STF35) as a possible oxygen electrode material for Solid Oxide Cells. The powder synthesis was performed by solid state method. Characterization included DC electrical conductivity study of sintered bulk samples and impedance spectroscopy study of symmetrical electrodes deposited on gadolinium doped ceria substrates. Measurements were carried out in atmospheres with different pO2...
-
Impedance plethysmography as a tool for assessing exertion-related blood flow changes in the lower limbs in healthy subjects
Publication -
New possibilities of the passive layer cracking dynamics detection using a new Dynamic Electrochemical Impedance Spectroscopy.
PublicationNowa metoda Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej opracowana w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej Politechniki Gdańskiej daje możliwości określania charakterystyki impedancyjnej w dziedzinie czasu podczas procesu pękania ochronnej warstwy pasywnej. Fakt ten jest związany z procedurą analizującą wspomnianej techniki, która umożliwia selektywną analizę czasowo-częstotliwościową uzyskanych...
-
Evaluation of cavitation erosion-corrosion degradation of mild steel by means of Dynamic Impedance Spectroscopy in galvanostatic mode
PublicationPrzedstawiono wyniki badań degradacji stali węglowych na skutek oddziaływania erozji-korozji kawitacyjnej. Do analizy wykorzystano technikę Dynamicznej Elektrochemicznej Spektroskopii Impedancyjnej w trybie galwanostatycznym, bliżej odwzrorowującym warunki naturalne. Do oceny stopnia degradacji posłużyły również funkcja ubytku masy MDPR oraz obrazy mikroskopowe SEM. Potwierdzono wpływ łączonej degradacji erozyjno-korozyjnej na...
-
Teoretyczny opis metody pomiaru chwilowego widma impedancyjnego. Theoretical description of the measuring of instantenous impedance spectra
PublicationPrzedstawiony został teoretyczny opis wyznaczania chwilowego widma impedancyjnego. Połączenie szumu pseudo-białego oraz metody krótkoczasowej transformacji Fouriera pozwala na wyznaczenie zmian widma impedancyjnego w funkcji czasu. Teoretyczne podstawy nowej metody pomiarowej wskazują na możliwość zastosowania jej do procesów niestacjonarnych.
-
Stanowisko laboratoryjne do pomiaru impedancji pętli zwarciowej
PublicationZnajomość wartości impedancji pętli zwarciowej umożliwia określenie warunków napięciowych oraz zwarciowych w systemie elektroenergetycznym. Zmierzona wartość impedancji pętli pozwala oszacować spadki napięcia w rozpatrywanej sieci, które bezpośrednio wpływają na jakość zasilania energii elektrycznej dostarczanej odbiorcom.W referacie przedstawiona została propozycja przebiegu ćwiczenia oraz laboratoryjnego stanowiska pomiarowego...
-
Błędy dynamiczne wyznaczania impedancji uziemienia metodą podharmonicznej
PublicationWyznaczanie rezystancji lub impedancji uziemienia metodą podharmonicznej umożliwia uzyskanie dobrej dokładności pomiaru nawet w obecności silnych zakłóceń pochodzących od prądów błądzących występujących w gruncie. Metoda podharmonicznej wykazuje znaczną odporność na zakłócenia o częstotliwości sieciowej jak i stałoprądowe. W artykule przedstawiono wyniki badań nad wpływem zmian dynamicznych zakłóceń o częstotliwości sieciowej jak...
-
Analiza widmowa sygnału zmian impedancji klatki piersiowej
PublicationW diagnostyce wielu chorób serca ważna jest ocena nie tylko jego pracy elektrycznej (na podstawie sygnału elektrokardiograficznego) lecz również pracy mechanicznej oraz sprzężenia elektromechanicznego w sercu. Zastosowanie metod pomiarowych pozwalających na badanie zarówno parametrów elektrycznych jak i mechanicznych serca jest szczególnie istotne w przypadku podejrzenia dyssynchronii. Do określenia synchroniczności mechanicznego...
-
Wyznaczanie impedancji przetwornika piezoelektrycznego z odpowiedzi impulsowej.
PublicationW artykule przedstawiono metodę wyznaczania impedancji przetwornika z jego odpowiedzi impulsowej. Odpowiedź impulsową rejestruje się za pomocą oscyloskopu cyfrowego Impedancję oblicza się z zarejestrowanej odpowiedzi impulsowej używając szybkiej transformaty Fouriera. Zaproponowana metoda pomiaru może znacznie uprościć system pomiarowy pełnej (zespolonej) impedancji elektrycznej w funkcji częstotliwości. W artykule pokazano zalety...