Publications
Filters
total: 858
Catalog Publications
-
Badania laboratoryjne wybranych sposobów koordynacji regulatora transformatora blokowego oraz regulatora generatora
PublicationWprowadzenie wymogu stosowania transformatorów blokowych z przekładnią regulowaną pod obciążeniem spowodowało konieczność określenia właściwego sposobu podziału kryteriów sterowania pomiędzy regulator generatora a regulator transformatora blokowego. W referacie zwrócono uwagę na aspekt miejsca pomiaru napięć. Ma to istotny wpływ zarówno na algorytm jak i jakość regulacji. Rozważania teoretyczne zilustrowane zostały wynikami prób...
-
Effect of the inclination angle of the condenser on the heat transfer coefficient value – experimental study
PublicationWhen considering problem of the condensation of the refrigerant in a flow inside channel, one needs to pay attention to the shape of its cross-section, the hydraulic diameter, the channel length as well as the orientation of the channel axis in space (horizontal, vertical, inclined). This paper presents an experimental study concerning the effect of the inclination angle of the condenser with a single coil pipe on the heat transfer...
-
Resonant Conditions in a Node with an SVC Compensator
PublicationThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
Zjawiska rezonansowe a praca zabezpieczeń nadprądowych dławików kompensacyjnych linii wysokiego napięcia
PublicationW referacie prezentowany jest opis działania zabezpieczeń nadprądowych dławików kompensacyjnych zainstalowanych w linii Ełk Bis – Alytus, jakie miało miejsce w grudniu 2015 r. W efekcie działania zabezpieczeń nastąpiło zbędne wyłączenie dwóch dławików. Referat wyjaśnia przyczyny zaistniałej sytuacji prezentując analizę matematyczną, wyniki symulacji komputerowej oraz dane z rejestratorów zakłóceń.
-
Rozproszona dostawa usług systemowych
PublicationJednym z wyzwań technicznych i organizacyjnych przed jakimi stanął system elektroenergetyczny w uwarunkowaniach rynkowych jest zorganizowanie rynku systemowych usług regulacyjnych. Rosnący udział rozproszonych, niespokojnych źródeł wytwarzania energii oraz zmiana rynkowej pozycji odbiorców, powodują zapotrzebowanie na rozproszone dostarczanie usług regulacyjnych. W tym celu poszukuje się możliwości wykorzystania zdolności do działań...
-
Rozproszona dostawa usług systemowych
PublicationRosnący udział rozproszonych, niespokojnych źródeł wytwarzania energii oraz zmiana rynkowej pozycji odbiorców, powodują zapotrzebowanie na rozproszone dostarczanie usług regulacyjnych. W tym celu poszukuje się możliwości wykorzystania zdolności do działań regulacyjnych: rozproszonych wytwórców, odbiorców, prosumentów lub układów wykorzystujących zasobniki energii. Za najważniejsze próby, omówione w referacie, należy uznać: - rozwiązania...
-
Analiza lokalizacji biogazowni metodami AHP i taksonomi numerycznej - porównanie metod
PublicationArtykuł przedstawia porównanie wielokryterialnej metody Analytic Hierarchy Proces oraz taksonomii numerycznej w oparciu o wybór lokalizacji biogazowni.
-
ZMIANY POZIOMÓW NAPIĘĆ W SIECI NISKIEGO NAPIĘCIA Z PRZYŁĄCZONYMI ŹRÓDŁAMI GENERACJI ROZPROSZONEJ
PublicationWprowadzenie generacji rozproszonej do sieci niskiego napięcia może wywołać w niej problemy natury napięciowej. W artykule zaprezentowano wpływ generacji rozproszonej na poziomy napięć w sieci niskiego napięcia. Rozpatrzono różne punkty przyłączenia źródeł i związane z tym zmiany poziomów napięć. Analizę przeprowadzono dla rzeczywistej sieci niskiego napięcia o znacznej długości. Sieć zasila budynki mieszkalne zlokalizowane na...
-
Analiza opłacalności inwestycji z instalacji opalanych paliwami gazowymi lub o łąścznej mocy zainstalowanej elektrycznej źródła poniżej 1 MW w oparciu o prognozę cenową praw majątkowych
PublicationZa energię wytworzoną w instalacjach opalanych paliwami gazowymi lub w jednostkach o mocy poniżej 1 MW uzyskuje się tzw. żółty certyfikat. Nowelizacja ustawy Prawo energetyczne przedłuża do końca 2018 roku funkcjonowanie systemu wsparcia. W artykule przedstawiono predykcję ceny rynkowej dla praw majątkowych z kogeneracji do 2025 roku dla instalacji opalanych paliwami gazowymi lub o łącznej mocy zainstalowanej elektrycznej źródła...
-
Zabezpieczanie dławika uziemiającego przyłączonego do punktu gwiazdowego dławika kompensacyjnego wysokiego napięcia
PublicationW artykule przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Załączono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015 roku, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Wykorzystanie liczników AMI w procesie optymalizacji pracy sieci niskiego napięcia
PublicationPrezentowany jest opis projektu dotyczącego m.in. optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI. Prace były prowadzone w ramach europejskiego grantu UPGRID, realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski.
-
Problemy pracy zabezpieczeń odległościowych linii 400 kV w Polsce północno-wschodniej
PublicationPrzedstawiono analizę wpływu połączenia polskiego systemu elektroenergetycznego z systemem Litwy na detekcję zakłóceń przez zabezpieczenia odległościowe linii 400 kV znajdujących się w najbliższym otoczeniu stacji Ełk Bis.
-
Analiza napięć indukowanych i strat mocy w kablach elektroenergetycznych wysokiego napięcia dla wybranych sposobów uziemienia żył powrotnych
PublicationDostarczanie mocy do centrów miast coraz częściej odbywa się z wykorzystaniem linii kablowych o napięciu 110 kV. To dogodny sposób zasilania, a praktycznie jedyny możliwy w przypadku gęstej zabudowy miejskiej. Kable wysokiego napięcia zawierają współosiową żyłę powrotną, w której podczas normalnej pracy oraz w stanach zakłóceniowych (podczas zwarć) mogą indukować się znaczne napięcia względem ziemi, co zagraża porażeniem i/lub...
-
Wykorzystanie infrastruktury systemu ami w monitorowaniu i sterowaniu sieciami niskiego napięcia
PublicationW referacie przedstawiono wybrane zagadnienia z prac prowadzonych w ramach europejskiego grantu UPGRID realizowanego przez konsorcjum firm z siedmiu państw europejskich, w tym również z Polski, który dotyczy między innymi optymalizacji pracy sieci niskiego napięcia przy wykorzystaniu danych z liczników AMI.
-
Analiza napięć indukowanych w żyłach powrotnych kabli wysokiego napięcia dla ich wybranych konfiguracji
PublicationW żyłach powrotnych kabli wysokiego napięcia mogą indukować się znaczne napięcia względem ziemi przy przepływie prądów roboczych oraz prądów zwarciowych, co zagraża porażeniem i/lub uszkodzeniem zewnętrznej powłoki kabla. Wartości tych napięć zależą od sposobu ułożenia i długości kabli, sposobu uziemienia ich żył powrotnych, wartości prądu w żyłach roboczych, a także transpozycji żył roboczych i powrotnych. W artykule przedstawiono...
-
Wybrane problemy detekcji zakłóceń w dławiku uziemiającym przyłączonym do punktu gwiazdowego dławika kompensacyjnego
PublicationW referacie przedstawiono problematykę zabezpieczania dławików uziemiających przyłączanych do punktu gwiazdowego dławików kompensacyjnych stosowanych w liniach wysokiego napięcia, ze szczególnym uwzględnieniem detekcji zwarć wewnętrznych. Przedstawiono analizy modelowe dla rzeczywistego układu oddanego do pracy w 2015, który docelowo ma zostać doposażony w dławiki uziemiające.
-
Zmiany cen na hurtowym rynku energii elektrycznej w Polsce
PublicationW artykule omówiono zmiany cen na hurtowym rynku energii elektrycznej w Polsce. Przedstawiono poziomy cen na terminowych rynkach energii elektrycznej oraz na rynku transakcji spotowych. Odniesiono się do wpływu opłat emisyjnych w ramach systemu EU ETS na cenę energii elektrycznej na rynku krajowym. Przedstawiono zasadnicze uwarunkowania struktury wytwórczej w Polsce, mające wpływ na poziom cen energii. Omówiono także zmienność...
-
Price Changes in Wholesale Market of Electrical Energy in Poland
PublicationThe article discusses the Price changes on the wholesale electricity market in Poland Moreover, The price levels on the futures electricity markets and the spot transactions market are presented. The impact of emission charges under the EU ETS on the price of electricity in the domestic market has been taken into consideration Furthermore, the basic determinants of the generation structure in Poland that influence the level of...
-
Pomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi selektywnymi
PublicationPomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi bezzwłocznymi jest kłopotliwy, ponieważ przy stosowaniu typowych mierników o prądzie pomiarowym rzędu 10-20 A zwykle następują zbędne zadziałania tych zabezpieczeń. W przypadku obwodów z wyłącznikami różnicowoprądowymi selektywnymi jest inaczej. W referacie wykazano, że pomiar ten można wykonać nawet miernikiem wielkoprądowym wymuszającym prąd o wartości...
-
Stosowanie wyłączników różnicowoprądowych w instalacjach fotowoltaicznych
PublicationPrzedstawiono postanowienia norm odnoszące się do doboru i instalowania wyłączników różnicowoprądowych w instalacjach fotowoltaicznych. Zwrócono uwagę, że w instalacjach takich nie ma obowiązku stosowania wyłączników różnicowoprądowych. Omówiono wpływ kształtu przebiegu prądu ziemnozwarciowego ze składową stałą na próg wyzwalania tych zabezpieczeń. Podano przykładowe wartości prądów upływowych w instalacjach fotowoltaicznych i...
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
WPŁYW PANDEMII COVID-19 NA OBCIĄŻENIE POLSKIEGO SYSTEMU ELEKTROENERGETYCZNEGO ORAZ POTENCJAŁ WYKORZYSTANIA USŁUGI DSR
PublicationW artykule przedstawiono wpływ restrykcji w funkcjonowaniu przemysłu, handlu i życia społecznego na obciążenie KSE podczas pierwszego lockdownu. W celu zbadania wpływu pandemii na obciążenie KSE dokonano analizy porównawczej dwóch analogicznych okresów trwających od połowy marca do końca maja w latach 2017 - 2019 i 2020. Porównano wartości charakteryzujące poszczególne tygodnie rozpatrywanego okresu. W roku 2020 zaobserwowano znaczne...
-
Analiza obciążalności prądowej długotrwałej przewodów elektroenergetycznych z wykorzystaniem zaawansowanych metod numerycznych
PublicationNiniejsza rozprawa doktorska przedstawia analizę obciążalności prądowej długotrwałej przewodów elektroenergetycznych na przykładzie linii kablowej niskiego napięcia YKY 35 mm2. Analizę obciążalności przeprowadzono w programie ANSYS Fluent, wykorzystującym numeryczną mechanikę płynów (ang. Computional Fluid Dynamics, CFD). W analizach obciążalności prądowej długotrwałej przewodów (kabli) elektroenergetycznych uwzględniono następujące...
-
Pomorski Archipelag Wysp Energetycznych
PublicationOmówiono możliwy rozwój energetyki prosumenckiej na terenie województwa pomorskiego. Odniesiono się do form organizacyjnych oraz współpracy lokalnych struktur z systemem elektroenergetycznym.
-
WYDZIELONE STRUKTURY W ZDECENTRALIZOWANYM SYSTEMIE ELEKTROENERGETYCZNYM
PublicationJednym z trendów, które są obserwowane we współczesnych systemach elektroenergetycznych jest stopniowa decentralizacja, będąca w dużej mierze efektem rosnącej roli generacji rozproszonej oraz ewolucją odbiorców w stronę prosumeryzmu. Rośnie rola lokalnego bilansowania i rodzi się zapotrzebowanie na powstawanie lokalnych struktur organizacyjnych, dążących do wydzielenia części infrastruktury elektroenergetycznej. Rodzi to nie tylko...
-
Development of the Polish energy sector through transformation and harmonization with the European energy and climate policy
PublicationThe paper presents the dilemmas of energy sector development vs European energy policy due to the way of energy transition. The identification of barriers and opportunities for the development of the power industry is presented. The possibilities of using modern energy technologies for the processes of energy transformation are described. The path useful to achieving climate and energy goals is determined. The new method of electricity...
-
BEZPIECZEŃSTWO PRACY SYSTEMU ELEKTROENERGETYCZNEGO - WSTĘP
PublicationWstęp omawia pięć kolejnych rozdziałów, o różnym poziomie szczegółowości, odnoszących się głównie do problemów bezpieczeństwa pracy i poprawy niezawodności pracy systemów elektroenergetycznych. Odniesiono się do aktualnych problemów w systemach energetycznych oraz podkreślono aspekt praktyczny rozważanych zagadnień.
-
RCDs Tripping in the Range from DC to AC 50 kHz for Slowly Rising Residual Current
PublicationThe wide use of power electronic converters means that in many low-voltage systems earth fault currents containing components from DC to AC of various frequencies have to be taken into account. Due to the tendency to increase the modulation frequency in converters, components of higher frequencies may be in the order of several tens of kilohertz. Therefore, it is very important to verify the behavior of devices for protection against...
-
The new investing effectiveness evaluation multi-criteria method in modern supply systems
PublicationThe important problem in the processes of modelling and programming the development of sustainable energy sector is the multi-criteria manner of assessing the effectiveness of investments. The goal of this paper is to show how to take into account the impact of investments in multidimensional modelling decision-making processes. This goal can be achieved through the development, presentation, and use of a new multi-criteria method...
-
Reliability Analysis of Data Storage Using Survival Signature and Logic Differential Calculus
PublicationThe Data storage system is an important part of any information system. All the necessary data that must be available for the successful operation of the information system are stored here. Therefore, it is advisable to think about the reliability of such a data storage system. As part of reliability engineering, it is possible to perform a reliability analysis of any system. Therefore, the data storage system can be analyzed as...
-
Bilansowanie lokalne w systemie elektroenergetycznym
PublicationWprowadzenie rozliczeń rynkowych w handlu energią elektryczną wymusiło nowe podejście do krótkookresowego bilansowania energii w systemie elektroenergetycznym. Dla sprawnego funkcjonowania handlu energią, konieczne było wprowadzenie Rynku Bilansującego, łączącego realizację zadań technicznych i handlowych. Obecnie bilansowanie systemu rozwiązywane jest ogólnosystemowo. Decentralizacja procesu wytwarzania energii, rozwój niespokojnych...
-
Management of MV/LV Transformer Replacement Based on AMI Platform
PublicationThe paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.
-
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublicationThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
Estimation of Synchronous Generator and AVR Parameters Based on Gradient and Genetic Methods
PublicationThe author present a method for the estimation of selected synchronous generator model and AVR parameters using a gradient and a genetic algorithm. The paper shows an example of model parameter estimation for a turbogenerator, based on the generator voltage time responses obtained during an active and reactive power rejection test
-
Wytwarzanie energii elektrycznej - diagnoza i terapia
PublicationW artykule przeanalizowano stan i dalszy rozwój krajowego sektora wytwarzania energii elektrycznej w świetle najnowszych raportów Międzynarodowej Agencji Energetycznej, wskazujących potencjalne trendy i perspektywy w światowej energetyce. Na tle przewidywanego wzrostu zapotrzebowania na energię elektryczną wskazano na możliwość istotnego ograniczenia emisji CO2 drogą zastąpienia przestarzałych, nieefektywnych...
-
Przesył energii elektrycznej - potrzeby,progi i bariery
PublicationW artykule przeanalizowano stan aktualny i kierunki rozwoju krajowego systemu przesy ł owego w kontek ś cie potrzeb gospodarki krajowej. Przedstawiono znaczenie sieci przesy ł owych oraz rol ę operatorów systemu przesy ł owego i systemów dystrybucyjnych w sektorze energetycznym. Oceniono mo ż liwo ś ci rozwoju przy uwzgl ę dnieniu aktualnych prognoz zapotrzebowania na energi ę , wytyczono potencjalne...
-
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublicationRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Real-time hybrid model of a wind turbine with doubly fed induction generator
PublicationIn recent years renewable sources have been dominating power system. The share of wind power in energy production increases year by year, which meets the need to protect the environment. Possibility of conducting, not only computer simulation, but also laboratory studies of wind turbine operation and impact on the power system and other power devices in laboratory conditions would be very useful. This article presents a method...
-
Thermal and Electrodynamic Risk of Residual Current Devices in the Case of Back-Up Protection by Overcurrent Circuit Breakers
PublicationResidual current operated circuit breakers without integral overcurrent protection should be back-up protected. As back-up protection devices, overcurrent circuit breakers are used. The maximum let-through energy and let-through current of the overcurrent devices were evaluated under laboratory conditions. The thermal and electrodynamic risk of residual current devices was analyzed.
-
Metody doboru miejsc zainstalowania zasobników energii w sieciach elektroenergetycznych niskiego napięcia
PublicationW związku z rosnącą liczbą źródeł odnawialnych przyłączanych do sieci niskiego napięcia (nn) jakość energii elektrycznej w tej sieci ulega pogorszeniu. Jedną z metod jej poprawiania jest instalowanie zasobników energii, tj. baterii akumulatorów, superkondensatorów czy kół zamachowych. Zasobniki energii są w stanie złagodzić dobową zmienność obciążenia, skompensować moc bierną i wyższe harmoniczne oraz zmniejszyć asymetrię obciążenia...
-
Energy Consumption Analysis Methods in Industry
PublicationThis paper overviews applied methods to evaluate energy consumption in Industry. The most important law regulations are presented, which decide on the necessity to conduct an effec - tive energetic economy. Basic assumptions are defined to calculate direct and cumulative energy consumption. The pros and cons of using each method are presented.
-
Metrological analysis of an computerized system of protection against electric shock in circuits with variable speed drives
PublicationDrive systems, that can be operated at variable speed, are equipped with power electronics converters. This causes distortion of the earth current, and consequently the need to take into account the use of proper protective devices in relation to earth current harmonics. This paper presents a system for protection against electric shock in circuits with power electronics converters and metrological analysis indicating the requirements...
-
Zastosowanie specjalnego uziemienia żył powrotnych w liniach kablowych SN
PublicationW artykule porównano metody uziemiania żył powrotnych kabli średniego napięcia. Głównym kryterium oceny poszczególnych rozwiązań było ograniczenie strat w przesyle energii elektrycznej oraz zapewnienie ochrony przeciwprzepięciowej osłon kabli. Na podstawie symulacji kabli zamodelowanych w programie CYMCAP i otrzymanych wyników obciążalności prądowej i strat w linii zaprezentowano metodę krzyżowania żył powrotnych (CB – cross-bonding...
-
Modelling of MV and HV Cable Lines
PublicationOverhead and cable lines are fundamental elements of power systems. Participation of cable lines is smaller and their percentage decreases as voltage is increased. HV cable lines are often built with the use of cables which are composed of coaxial metallic sheaths. Such cables are also often used in MV networks. The sheath may operate in different confgurations. In the case of Polish MV network the sheaths are earthed at both ends....
-
Comparison of Transmission Capacities of Two Regulation Systems: Lateral and in-phase Control Transformers
PublicationThis paper presents a comparison of regulation capabilities of lateral and in-phase control transformers in a selected node of a power system. Their regulation capabilities are presented, as well as cross-system exchange options.
-
Pomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi selektywnymi
PublicationPomiar impedancji pętli zwarciowej w obwodach z wyłącznikami różnicowoprądowymi bezzwłocznymi jest kłopotliwy, ponieważ przy stosowaniu typowych mierników o prądzie pomiarowym rzędu 10-20 A zwykle następują zbędne zadziałania tych zabezpieczeń. W przypadku obwodów z wyłącznikami różnicowoprądowymi selektywnymi jest inaczej. W artykule wykazano, że pomiar ten można wykonać nawet miernikiem wielkoprądowym wymuszającym prąd o wartości...
-
Neutral earthing reactor protection
PublicationThe IEEE and CIGRE recommend protection systems for high voltage shunt reactors. Unfortunately the recommendations do not include guidelines for the protection of neutral earthing reactors, which are often connected to shunt reactors to increase the effectiveness of single pole auto-reclosing. The paper discusses earthing reactor protection issues with particular emphasis on the detection of internal faults. An analysis carried...
-
Time-current tripping characteristics of RCDs for sinusoidal testing current
PublicationLow-voltage electrical installations are verified initially – before being put into operation, as well as periodically – during their utilization. According to the IEC standards, the scope of the verification includes measurements of both the tripping current and the disconnection time of residual current devices (RCDs). Experiences in RCDs testing show that disconnection times of two or more similar RCDs can be quite different....
-
The Concept of a Methodology for Selecting the Optimal Parameters of Heat Received from a Nuclear Power Plant Operating in a Partial Cogeneration Mode
PublicationThe paper presents the concept of the objective function which is to allow the selection of optimal parameters of the district heating system using a nuclear power plant operating in partial cogeneration mode. The concept is based on research carried out a number of years ago. The size of annual expenses was proposed as the objective function, which allows to compare the operation of a nuclear power plant in partial cogeneration...
-
Tripping of F-type RCDs for sinusoidal residual current with superimposed smooth DC component
PublicationRecent trends in green energy development make that photovoltaics and electric vehicles are applied on an increasing scale. In both photovoltaic and electric vehicle charging installations, a significant value of DC component of the earth fault current may appear, which is a challenge, in particular, for commonly used residual current devices (RCDs). This paper presents results of the laboratory test on the operation of F-type...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublicationThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Nuclear Co-generation: The Analysis of Technical Capabilities and Cost Estimates
PublicationThis paper presents a concept of the parallel connection of a nuclear power plant fitted to provide heat for district heating application, with the CHP and heat plants existing in the supply region, in this case with the heating systems of Wejherowo and Gdynia. Presented variant proposes to add heat to a nuclear power plant’s total output by supplying heat exchangers with the steam from bleeders of low pressure (LP) turbine stage...
-
Selected problems of earth fault loop impedance testing in circuits fed from UPS
PublicationIn the paper a principle of earth fault loop impedance testing in low voltage systems has been presented. Selected factors, influencing accuracy of the testing, are indicated. A structure of UPS of VFI-type and the problem of impedance testing in circuits with such type of UPS are discussed.
-
Optimization of Nuclear Power Share in the Structure of Electricity Production in Poland in Time Perspective by 2060
PublicationThe author of this paper presented the results of a system analysis using MARKAL model, aiming at the optimization of nuclear power share in power generation structure in Poland in time perspective by 2060. Optimization criterion is the minimization of the objective function, i.e. the total cost of energy system, taking into account constraints related to CO2, SOx and NOx emissions and obligatory shares of electricity from renewable...
-
Calculations of Short-Circuit Current Flows in Earth Wires of HV Lines
PublicationThis paper presents a method which enables calculating flows of short-circuit currents in earth wires of high voltage transmission lines, and its implementation in the form of a computer programme. The algorithm enables performing calculations for a double-fed line and starconnected lines (three terminal lines). The developed programme enables verifying dimensioning of earth wires in the context of their short-circuit thermal withstand...
-
A New Method of the Load Compensation Use During Creation of Post Blackout Start-up Path in Power System
PublicationIn the paper a new method of effective use of load compensation during creation of post blackout start-up path is proposed. Theoretical assumptions and simulation results of an investigation are presented. An experiment performed in the Polish Power System is also described. This experiment proved that the method proposed by the authors is advisable. The method may be utilized by power system operators for power system restoration...
-
The Method of Multi-criteria Analysis to Support the Decision on Load or Micro-generation Connection to a Low- or Medium-voltage Power Grid
PublicationThis paper presents a method that supports the decision in terms on selecting the best option of a load connection to a low- or medium-voltage power distribution grid, and of a micro-generation source connection to a low-voltage grid. The method is based on the search for the option with the lowest aggregate assessment measure, which is the weighted average of partial assessment measures determined for each of eight considered...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublicationMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
Kłopotliwy przypadek ochrony przeciwporażeniowej w linii elektroenergetycznej o napięciu 110 kV
PublicationOchrona przeciwporażeniowa przy słupach linii elektroenergetycznych wysokiego napięcia ściśle zależy od rodzaju i lokalizacji słupów, a także od nastaw elektroenergetycznej automatyki zabezpieczeniowej. Największe zagrożenie porażeniowe występuje przy słupach przewodzących, posadowionych w miejscach, gdzie często przebywają ludzie i mogą oni chodzić boso. W artykule przedstawiono ocenę zagrożenia porażeniowego przy słupie kratowym...
-
Remarks on the Subject of Back-Up Protection of Residual Current Devices
PublicationResidual current devices without integral overcurrent protection (RCCBs) are back-up protected by fuses or miniature circuit-breakers (MCBs). If the latter are used, special attention must be given to the coordination between an RCCB and an MCB. This paper indicates probable cases of the aforementioned devices coordination, in which back-up protection of the RCCB is not adequate. A laboratory test has shown that depending on the...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
Selection of energy storage units by genetic algorithm for mitigating voltage deviations
PublicationIn recent years, energy storage units have become very popular. They are applied both for economic and technical purposes. Unfortunately, the cost of such devices is still high and selecting their proper location and rated power have to be performed precisely. In this paper, a Genetic-Algorithm-based optimization method for selecting the best configuration of energy storage units in the power network is proposed. The presented...
-
Power Hardware-in-the-Loop Approach In Power System Development
PublicationThe main objective of the research is the verification of the Power Hardware-In-The-Loop (PHIL) approach in power system analysis and design. The premise of the article is that using PHIL approach the performance of the power system in steady and transient state conditions can be analysed in real power system conditions. Models of induction machine were developed and real time simulations were performed. Simulation variables were...
-
Crystalline Silicon (c-Si)-Based Tunnel Oxide Passivated Contact (TOPCon) Solar Cells: A Review
PublicationContact selectivity is a key parameter for enhancing and improving the power conversion efficiency (PCE) of crystalline silicon (c-Si)-based solar cells. Carrier selective contacts (CSC) are the key technology which has the potential to achieve a higher PCE for c-Si-based solar cells closer to their theoretical efficiency limit. A recent and state-of-the-art approach in this domain is the tunnel oxide passivated contact (TOPCon)...
-
Resonance problems in UHV transmission lines
PublicationThe paper presents resonance phenomena observed in 400 kV transmission lines in the Polish power system. Two events are analysed, when shunt reactors used for reactive power compensation, caused overvoltages and overcurrent protection tripping as a result of resonance. An oscillographic fault recordings from protection devices are compared to time domain simulation results. The obtained simulation results match fault recordings,...
-
Selected problems of decision making modelling in power engineering
PublicationThe paper presents the selected problems of decision making modelling in power engineering specially investment risk evaluation methods. The proposed model can be used in the range programming the development and investing process in power engineering. Decision making problems in power engineering and the evaluation of investment effectiveness in particular are closely related to modelling which relatively accurately reflects...
-
Selected information technology tools supporting for maintenance and operation management electrical grids
PublicationThe paper presents the main issues of management of electrical grids. Selected information technology tools supporting for electrical grids maintenance are presented. In electrical infrastructure maintenance of power companies the geographic information systems are increasingly used to support the management of theirs resources. Their functionalities in terms creating comprehensive databases for electrical infrastructure of power...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublicationResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublicationThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Polityka i porządek prawny w polskiej energetyce na tle polityki Unii Europejskiej
PublicationW artykule przeanalizowano rozwój wspólnotowego rynku energii elektrycznej, polityk ę energetyczną Polski i UE, sytuację i działania Polski na wspólnotowym rynku energii elektrycznej, a następnie przeanalizowano nowe regulacje prawne dla współpracy rozproszonych źródeł energii elektrycznej i sieci inteligentnych z systemem krajowym, dla zwrotu energii odzyskiwanej z systemów elektromechanicznych do zasilającej...
-
Computer-aided analysis of resonance risk in power system with Static Var Compensators
PublicationStatic Var Compensators operation in a power system may significantly improve voltage profiles in nodes and the reactive power balance, as well as ensure greater system stability in emergency conditions. However these devices may be a cause of a resonance in the system. The aim of this paper is to call attention to the need to include resonance phenomena in a compensator’s location evaluation process. The analysis performed in...
-
Study of the Operation of Synchronous Generator Voltage Regulator During the Creation of Post Blackout Start-up Path
PublicationThis paper presents the influence of automatic voltage regulator (AVR) of synchronous generator on the process of creation of post black-out start-up path. Two elements of AVR have a significant impact on this process: underexcitation limiter (UEL) and load compensation (LC). The authors present a theoretical investigation and simulation results that illustrate how the mentioned elements of AVR affect voltage levels in a power...
-
Testing Situation Awareness Network for the Electrical Power Infrastructure
PublicationThe contemporary electrical power infrastructure is exposed to new types of threats. The cause of such threats is related to the large number of new vulnerabilities and architectural weaknesses introduced by the extensive use of Information and Communication Technologies (ICT) in such complex critical systems. The power grid interconnection with the Internet exposes the grid to new types of attacks, such as Advanced Persistent...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublicationThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Delivery of Ancillary Services in Distribution Power Systems
PublicationOne of the technical and organizational challenges the power system faces in deregulated market conditions is to organize an ancillary services market. The growing share of distributed generation of variable (intermittent) energy sources and a change in the market position of consumers, causes the demand for distributed delivery of ancillary services. For this purpose, it is sought to use the ability of the regulatory measures:...
-
Identification of the customer meter assignment to phases in LV grid: Selected issues of UPGRID project realization
PublicationThe paper presents selected issues on the European UPGRID grant implemented by a consortium of companies from seven European states, including from Poland, on the monitoring and control of low voltage grid using measurement pre-registered data by smart AMI meters. The paper focuses on the issue of lack of information on the assignment of communal meters to individual phases.
-
Security Requirements and Controls for Incident Information Sharing in the Polish Power System
PublicationAmong the strategies of protecting information assets of the power system, sharing of information about current cybersecurity incidents between energy operators appears to be a prerequisite. Exchange of information leads to the effective detection of attacks and exploited vulnerabilities as well as the identification of countermeasures. This paper presents the results of continuation of our works on developing a secure and efficient...
-
Effect of solar radiation on current-carrying capacity of PVC-insulated power cables – the numerical point of view
PublicationPower cables are usually buried in the soil, which results in their relatively high current-carrying capacity. However, there are cases in which the starting/final section of a cable line runs along a pole of an overhead power line. Power cables can be directly exposed to solar radiation then, and this negatively influences their current-carrying capacity as well as estimated life of the cables’ insulation. An analysis of thermal...
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Induced sheath voltages in 110 kV power cables – case study
PublicationThis paper considers electric shock hazard due to induced sheath voltages in 110 kV power cables. The purpose of this paper is to find an optimal configuration of the power cable system, taking into account electric shock hazard and ability of the system to transfer maximal power. A computer simulations on a computer model of the local power system, comprising high voltage power cables, were carried out. This model enables to analyse...
-
Effectiveness of the robust PSS design
PublicationThe paper discusses optimal PSS of synchronous generator synthesis. The optimal controller is an Hinf controller, what means that minimises Hinf norm of transfer function between the exogenous signals such as reference inputs and disturbances, and the error signals which are to be minimised to meet the control objective. The dynamic properties of the plant are shaped by choosing appropriate weighting function applied to the plant...
-
Overheating of underground power cable line due to its partial exposition to solar radiation
PublicationCurrent-carrying capacity of underground power cable lines depends, among others, on thermal resistivity of the soil and cables layout: trefoil formation, flat formation with or without spacing. If conditions for heat transfer in the ground are favorable, the current-carrying capacity is relatively high. Therefore, it generates risk of the power cables overheating, if part of the cable line is located vertically in the air, to...
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublicationThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Single and Series of Multi-valued Decision Diagrams in Representation of Structure Function
PublicationStructure function, which defines dependency of performance of the system on performance of its components, is a key part of system description in reliability analysis. In this paper, we compare two approaches for representation of the structure function. The first one is based on use of a single Multi-valued Decision Diagram (MDD) and the second on use of a series of MDDs. The obtained results indicate that the series of MDDs...
-
Magnetic and capacitive couplings influence on power losses in double circuit high voltage overhead transmission line
PublicationPurpose – The paper aims to discuss problems of power and energy losses in a double-circuit overhead transmission line. It was observed from energymeters’ readings, that in such a line, active power losses can be measured as “negative”. The “negative” active power losses appear when the active power injected to the circuit is lower than the active power received at the circuit end. The purpose of this paper is to explain this phenomenon. Theoretical...
-
The effect of current delay angle on tripping of residual current devices
PublicationPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Residual Current Devices: Selection, Operation, and Testing
PublicationIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Stability Enhancement of Grid-Connected Wind Power Generation System Using PSS, SFCL and STATCOM
PublicationThe stability related issues may occur in a power system due to disturbances in generating or loading conditions, especially in the presence of distributed generation (DG) based on renewable energy resources (RERs). This paper proposes a novel strategy for the stability enhancement of a wind power generation system (WPGS) by using a combination of three devices, namely, a power system stabilizer (PSS), resistive superconductor...
-
Design of power cable lines partially exposed to direct solar radiation – special aspects
PublicationPower cable lines are usually buried in the ground. However, in some cases, their ending sections are mounted along the supports of overhead lines. This leads to a situation where the cables are exposed to direct solar radiation and, consequentially, overheat. The paper presents the advanced computer modelling of power cables’ heating, considering their insolation as well as the effect of wind. The temperature and current-carrying...
-
The Possibility to use a Nuclear Power Plant as a Source of Electrical Energy and Heat
PublicationIn this article issues concernig the possibility of nuclear power plant (NPP) operation also as a source of heat, which means combined heat and power production, have been described. CHP work is possible and profitable only in those areas where high thermal power demand occurs, which means near city agglomerations such as Warsaw or the Tri-City. Two levels of thermal power delivered to the heating system have been considered. Preliminary...
-
Activity coordination of capacitor banks and power transformer controllers in order to reduce power losses in the MV grid
PublicationOne of the main issues related to the optimization of the MV (middle voltage) network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility...
-
Computer System for Evaluation of Shock Hazard in Circuits with Non-sinusoidal Earth Currents
PublicationEffects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents a computer system, based on LabVIEW environment,...
-
Intensification of thermal convection near electric devices using flat screens – computer modelling
PublicationIntensification of natural thermal convection near electric devices is possible by application of additional elements as screens creating convection canals close to the device. In the earlier authors paper the results of the analysis of thermal convection with the use of only one additional screen close to the electric device were presented. This paper presents computer modelling of thermal convection when two screens near the...
-
Behavior of residual current devices at earth fault currents with DC component
PublicationLow-voltage electrical installations are increasingly saturated with power electronic converters. Due to very high popularity of photovoltaic (PV) installations and the spread of electric vehicles (EV) as well as their charging installations, DC–AC and AC–DC converters are often found in power systems. The transformerless coupling of AC and DC systems via power electronic converters means that an electrical installation containing...
-
Tripping limitations of residual current devices in photovoltaic installations
PublicationIn electrical installations with photovoltaic sources of energy, earth fault current may comprise alternating current component and direct current component. The waveform shape of this earth fault current mainly depends on the point of the fault and the properties of a photovoltaic power electronics converter. The waveform shape of the current influences operation of protection devices, especially tripping threshold of residual...