Filtry
wszystkich: 769
wybranych: 629
-
Katalog
Filtry wybranego katalogu
Wyniki wyszukiwania dla: OPTICAL PARAMETERS
-
Physical properties of homogeneous TiO2 films prepared by high power impulse magnetron sputtering as a function of crystallographic phase and nanostructure
PublikacjaOptical, photo-electrochemical, crystallographic and morphological properties of TiO2 thin films prepared by high power impulse magnetron sputtering at low substrate temperatures (<65 ◦C) without post-deposition thermal annealing are studied. The film composition-anatase, rutile or amorphous TiO2-is adjusted by the pressure (p ∼ 0.75-15 Pa) in the deposition chamber. The different crystallographic phases were determined with grazing...
-
Investigation of optical properties of Infitec and Active Stereo stereoscopic techniques for CAVE-type virtual reality systems
PublikacjaIn recent years, many scientific and industrial centres in the world developed virtual reality systems or laboratories. At present, among the most advanced virtual reality systems are CAVE-type (Cave Automatic Virtual Environment) installations. Such systems usually consist of four, five, or six projection screens arranged in the form of a closed or hemi-closed space. The basic task of such systems is to ensure the effect of user...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublikacjaThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Fiber optic low-coherence Fabry-Pérot interferometer with ZnO layers in transmission and reflective mode: comparative study
PublikacjaA construction of a low-coherence fiber-optic Fabry-Pérot interferometer using a thin ZnO layer as a reflective surfaces was proposed and examined. In the investigated setup, the ZnO layer of thickness 200 nm were deposited on the face of the standard telecommunication single-mode optical fiber (SMF-28). Measurements of interference signal were performed for the interferometer working in the transmission and reflective mode, as...
-
Nanoparticle-free tissue-mimicking phantoms with intrinsic scattering
PublikacjaWe present an alternative to the conventional approach, phantoms without scattering nanoparticles, where scattering is achieved by the material itself: spherical cavities trapped in a silicone matrix. We describe the properties and fabrication of novel optical phantoms based on a silicone elastomer polydimethylsiloxane (PDMS) and glycerol mixture. Optical properties (absorption coefficient µa, reduced scattering coefficient µs',...
-
Spatially variant PSF modeling in confocal macroscopy
PublikacjaThe point spread function (PSF) of imaging systems plays an essential role in image reconstruction. In the context of confocal microscopy, optical performance degrades towards the edge of the field of view. In confocal macroscopy, the related artifacts are even stronger, as the field of view is much larger. Because the related PSFs are strongly spatially variant, it is essential to be able to model them with few parameters. The...
-
Low-coherence sensors with nanolayers for biomedical sensing
PublikacjaIn this paper, we describe the fiber optic low-coherence sensors using thin film. We investigated their metrological parameters. Presented sensors were made with the use of standard telecommunication single mode optical fiber (SMF28). Different materials were applied to obtain thick layers, such as boron doped diamond, silver and gold. The thickness of layers used in the experiments ranged from 100 nm to 300 nm. Measurements were...
-
Determination of refractive index dispersion using fiber-optic low-coherence Fabry–Perot interferometer: implementation and validation
PublikacjaWe present the implementation and validation of low-coherence Fabry–Perot interferometer for refractive index dispersion measurements of liquids. A measurement system has been created with the use of four superluminescent diodes with different optical parameters, a fiber-optic coupler and an optical spectrum analyzer. The Fabry–Perot interferometer cavity has been formed by the fiber-optic end and mirror surfaces mounted on a micromechanical...
-
Application of two-dimensional intensity maps in high-accuracy polarimetry
PublikacjaWe propose the analysis of 2D intensity contour maps which is based on the optical transmission function for the polarizer-specimen-analyzer system. A small modification of the high-accuracy universal polarimeter (HAUP) technique was used to measure the intensity maps (HAUP maps) and determine the phase retardation, linear dichroism (LD) parameters, and multiple light reflection contribution in uniaxial crystals. We have performed...
-
Fiber optic displacement sensor with signal analysis in spectral domain
PublikacjaIn this paper, a study of a low-coherence fiber optic displacement sensor is presented. The sensor consisted of a broadband source whose central wavelength was either at 1310 nm or 1550 nm, a sensing Fabry-Pérot interferometer operating in reflective mode and an optical spectrum analyzer acting as the detection setup. All these components were connected by a single-mode fiber coupler. Metrological parameters of the sensor were...
-
Response of a fiber-optic Fabry-Pérot interferometer to refractive index and absorption changes – modelling and experiments
PublikacjaThis paper describes how the refractive index and the absorption of investigated substances change the spectrum of the optical radiation at the output of the fiber-optic Fabry-Pérot interferometer. The modeling of the operation of the interferometer takes into account not only the spectra of the refractive index and the absorption of the medium that is inside the cavity, but also spectra of the refractive indices of the core and...
-
Influence of pulse waves on the transmission of near-infrared radiation in outer-head tissue layers.
PublikacjaIn this study, we investigate the effect of pulse waves on the transmission of near-infrared radiation in the outer tissue layers of the human head. This effect is important in using optical radiation to monitor brain conditions based on measuring the transmission changes in the near-infrared radiation between the source and the detector, placed on the surface of the scalp. This is because the signal related to the changes in the...
-
A navigation device utilizing body communication channel for mobile wearable systems
PublikacjaA novel touch sensor utilizing a body communication technology is presented in the paper. The proposed device accepts orders (gestures) only from a person wearing it. Moreover, when comparing it to a similar, however an optical one, it appears as a less power consumable. Preliminary results of its properties examination are presented and discussed. Additionally, the developed sensor allows to measure a human body the electrical...
-
Nano-particle doped hydroxyapatite material evaluation using Spectroscopic Polarization Sensitive Optical Coherence Tomography
PublikacjaBio-ceramics such as hydroxyapatite (HAp) are widely used materials in medical applications, especially as an interface between implants and living tissues. There are many ways of creating structures from HAp like electrochemical assisted deposition, biomimetic, electrophoresis, pulsed laser deposition or sol-gel processing. Our research is based on analyzing the parameters of the sol-gel method for creating thin layers of HAp....
-
Hydrothermal modification of TiO2 nanotubes in water and alkali metal electrolytes (LiNO3, NaNO3, KNO3) – Direct evidence for photocatalytic activity enhancement
PublikacjaThe influence of hydrothermal annealing (HA) of TiO2 nanotubes (TiO2-NTs) in various baths (H2O, LiNO3, NaNO3, KNO3 performed for 4 h, 24 h, 64 h), on their photocatalytic and photoelectrocatalytic properties, was studied. The use of electrolytes was to enable the monitoring of photoactivity changes as a result of the expected impact on the population of hydroxyl groups on the surface. The assumption turned out to be correct and...
-
Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications
PublikacjaStarting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review...
-
Optoelectronic device for hematocrit measurements
PublikacjaAn optoelectronic system for measurements of hematocrit level (HCT) in the whole human blood is presented. Proposed system integrates a dedicated optoelectronic sensor, a microcontroller and a small LCD display in a low cost, battery-powered, handheld device. Chosen method for determining blood hematocrit level is based on optical properties of whole blood in visible and NIR wavelength range. Measurements with the use of proposed...
-
Study of Photovoltaic Devices with Hybrid Active Layer
PublikacjaThe aim of this work is to present the influences of composition of the material andmanufacturing technology conditions of the organic photovoltaics devices (OPv) with the organicand hybrid bulk heterojunction on the active layers properties and cells performance. The layers wereproduced by using small molecular compounds: the metal-phthalocyanine (MePc) and perylenederivatives (PTCDA) and the titanium dioxide (TiO2) nanoparticles....
-
Fractographic-fractal dimension correlation with crack initiation and fatigue life for notched aluminium alloys under bending load
PublikacjaIn this study, fatigue fracture surfaces of aluminium alloy 2017-T4 notched specimens were investigated under cyclic bending to find an alternative failure loading index.. The surface topographies were measured on the entire fracture area with an optical profilometer for different loading conditions. Fatigue crack initiation life Ni and total fatigue life Nf were examined using standard surface topography parameters (such as, root...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublikacjaThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Application of the Fractional Fourier Transform for dispersion compensation in signals from a fiber-based Fabry-Perot interferometer
PublikacjaOptical methods of measurement do not require contact of a probe and the object under study, and thus have found use in a broad range of applications such as nondestructive testing (NDT), where noninvasive measurement is crucial. Measuring the refractive index of a material can give a valuable insight into its composition. Low‑coherence radiation sources enable measurement of the sample’s properties across a wide spectrum, while...
-
Niskokoherencyjne czujniki światłowodowe wykorzystujące cienkowarstwowe struktury nanodiamentowe
PublikacjaZnaczny rozwój technologii wytwarzania czujników światłowodowych spowodował, że są one powszechnie dostępne i stosowane w wielu gałęziach przemysłu, nauki oraz medycyny. Zastosowanie nowych materiałów w konstrukcji takich czujników niesie za sobą duży potencjał. Celem rozprawy jest przedstawienie możliwości wykorzystania cienkowarstwowych struktur nanodiamentowych w niskokoherencyjnych czujnikach światłowodowych, które poprawią...
-
Thermomagnetic behavior of a semiconductor material heated by pulsed excitation based on the fourth-order MGT photothermal model
PublikacjaThis article proposes a photothermal model to reveal the thermo-magneto-mechanical properties of semiconductor materials, including coupled diffusion equations for thermal conductivity, elasticity, and excess carrier density. The proposed model is developed to account for the optical heating that occurs through the semiconductor medium. The Moore–Gibson–Thompson (MGT) equation of the fourth-order serves as the theoretical framework...
-
Optoelectronic system for investigation of cvd diamond/DLC layers growth
PublikacjaDevelopment of the optoelectronic system for non-invasive monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during μPA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The system uses multi-point Optical Emission Spectroscopy (OES) and long-working-distance Raman spectroscopy. Dissociation of H2 molecules, excitation and ionization of hydrogen atoms...
-
The Performance of ASON/GMPLS Network with Hierarchical Control Plane Structure
PublikacjaThe paper regards the problem of ASON/GMPLS network performance with hierarchical control plane structure in condition of incomplete domain network information. The authors propose the hierarchical ASON/GMPLS control plane architecture, which fulfills the requirements of modern optical networks and allows to control the multidomain network with requirement quality of service. The authors examine the scalability and properties of...
-
Effect of bending-torsion on fracture and fatigue life for 18Ni300 steel specimens produced by SLM
PublikacjaIn this study, different fracture surfaces caused by fatigue failure were generated from 18Ni300 steel produced by selective laser melting (SLM). Hollow round bars with a transverse hole were tested under bending-torsion to investigate the crack initiation mechanisms and fatigue life. Next, the post-failure fracture surfaces were examined by optical profilometer and scanning electron microscope. The focus is placed on the relationship...
-
Fatigue fracture surface metrology of thin-walled tubular austenitic steel specimens after asynchronous loadings
PublikacjaThis paper aims to study the effect of asynchronous axial-torsional strain-controlled loading histories on fracture surface behavior of thin-walled tubular X5CrNi18-10 (304/304L) austenitic steel specimens. Tests under pure axial loading and pure torsional loading are also conducted to better segregate the effect of multiaxiality. The fractures surface topographies were examined through the profiles over the entire surface with...
-
Optoelectronic system for monitoring of thin diamond layers growth
PublikacjaDevelopment of the optoelectronic system for monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during mu PA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The multi-point Optical Emission Spectroscopy (OES) and Raman spectroscopy were employed as non-invasive optoelectronic tools. Dissociation of H-2 molecules, excitation and ionization of hydrogen...
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublikacjaFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Fracture Surface Behavior of 34CrNiMo6 High-Strength Steel Bars with Blind Holes under Bending-Torsion Fatigue
PublikacjaThe present study evaluates the fracture surface response of fatigued 34CrNiMo6 steel bars with transverse blind holes subjected to bending with torsion loading. The analysis of the geometric product specification was performed by means of height parameters Sx, functional volume parameters Vx, and fractal dimension Df. Surface topography measurements were carried out using an optical profilometer with focus variation technology....
-
Optical glyphs based localization and identification system
PublikacjaThe paper presents a description of functioning of a platform supporting the detection of obstructive diseases in the respiratory system education process. A 16-parameter model of the respiratory system simulated in the MATLAB/Simulink environment was set in the role of the tested patient. It has been linked to the control layer, developed in the LabVIEW environment, using the SIT library (Simulation Interface Toolkit). This layer...
-
Three-Dimensional Fractography for Conventional and Additive Manufactured Steels After Bending-Torsion Fatigue
PublikacjaIn this study, fracture surface topography parameters were measured to investigate the effects of multiaxial loading. In order to assess the metrological aspects of fracture for notched specimens made of high-strength steels processed by both conventional and additively manufacturing (AM) techniques, an optical surface profilometer was used. Three bending moment to torsion moment ratios (B/T) were studied, i.e. 2, 1 and 2/3. The...
-
Fracture Areas Quantitative Investigating of Bending-Torsion Fatigued Low-Alloy High-Strength Steel
PublikacjaIn this study, the impact of pseudo-random non-proportional bending-torsion fatigue loadings proportion on the fatigue life and the fracture surface topography was analyzed. Investigation was carried out for 24 specimens made of S355J2 steel with 11 different ratios of maximum stresses λ. For these cases, after the fatigue tests, the surface topography measurements were carried out using an optical profilometer, using the focus...
-
Studies on optical transmittance of boron-doped nanocrystalline diamond films
PublikacjaThickness is one of the most important parameters in many applications using thin layers. This article describes thickness determination of a boron-doped nanocrystalline diamond (NCD) grown on fused silica glass. A spectroscopic measurement system has been used. A high refractive index (2.3 at 550nm) was achieved for NCD films. The thickness of NCD samples has been determined from the transmission spectrum.
-
Assessment of FSW Welds Made of Aluminum Alloy AW7075-T651.
PublikacjaThis paper summarizes the results of experimental studies in which the aluminum alloy AW7075-T651 was friction stir welded (FSW) using various combinations of process parameters (rotational - R and travel speed - T). Mechanical properties of the test welds were assessed by using static tensile test and Vickers hardness measurement. The temperature of the welded plates was monitored during welding by means of thermocouples placed...
-
RAMAN DIAGNOSTICS OF CVD DIAMOND GROWTH
PublikacjaDevelopment of Raman spectroscopic system for diagnostics of growth of diamond and BDD (Boron- Doped-Diamond) thin films during μPA CVD (Microwave Plasma Assisted Chemical Vapour Deposition) process is described. Raman studies of such films were carried out as in-situ monitoring of film deposition as ex-situ measurements conducted for a sample outside the reaction vessel after manufacturing process. Modular system for the in-situ...
-
Cavitation Erosion Resistance of Austenitic Stainless Steel after Glow-Discharge Nitriding Process
PublikacjaThis paper presents investigation of cavitation erosion resistance of nitrided austenitic stainless steel X5CrNi18-10. The diffusion layers were produced by using different parameters of atmosphere (N2:H2). The microstructure, chemical composition and phase identification of the modified layer were examined using scanning electron microscopy, glow-discharge optical emission spectrometer and X-ray diffractometry, respectively. Cavitation...
-
Wpływ parametrów strugi paliwa wtryskiwanego do cylindra silnika okrętowego na początkową fazę rozpylania
PublikacjaPrzedmiotem rozprawy jest analiza procesu wtrysku oleju napędowego do cylindra silnika okrętowego z zapłonem samoczynnym i bezpośrednim wtryskiem paliwa. Analiza tego zagadnienia została przeprowadzona w aspekcie wpływu makro parametrów strugi na początkową fazę rozpylania oleju napędowego. Celem niniejszej pracy jest określenie wpływu współczynnika L/D (długość otworu/średnica) otworu wylotowego wtryskiwacza na zmianę charakterystyki...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublikacjaRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublikacjaThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublikacjaThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Studying of spin-coated oxad-Si properties
PublikacjaPurpose: The major aim of this paper was describing technical conditions of polymer thin film deposition byspin-coating techniques.Design/methodology/approach: Thin films of about nanometres thickness were prepared by spin-coatingand their properties were studied. As a material for preparing polymer thin films oxad-Si was used. The thinfilms were deposited with various spinning velocity from solution of different concentration....
-
Investigation of energy deposition and its optical imaging in polymer gel dosimeters
PublikacjaThis following chapter describes methods for verifying the absorbed dose during radiotherapy. Special attention is paid to the method using polymer-gel dosimeters, the dose reading of which is performed by means of Laser Computed Tomography. The chapter also includes considerations on alternative solutions for dosimetric measurements and various types of radiotherapy and their pros and cons. In addition, both the methods of structural...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublikacjaPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Influence of controlled crystallization and SrF2 content on the structure and properties of Eu3+ doped phosphate glasses
PublikacjaNew phosphate glasses and glass-ceramics P2O5–Bi2O3–K2O–Nb2O5-SrF2 doped with Eu were synthesized and studied in this work. The influence of the SrF2 content (0–15 mol%) and the parameters of the heat treatment on their structural and optical properties were investigated. For the above purpose, the structural characterization by FTIR spectroscopy and XRD measurements was carried out, which showed a significant effect of SrF2 on...
-
A new model of fuel spray shape at early stage of injection in a marine Diesel engine
PublikacjaIn the cylinders of a marine diesel engine, self-ignition occurs in very shortly time after the fuel injection into the combustion chamber. Therefore, the paper present was to develop a model of diesel fuel spray for the early stage of fuel spray for in marine diesel engine. There were taken into consideration the main aspects technical such as nozzle diameter of marine engine injector and backpressure in combustion chamber. In...
-
Spatial characterization of H 2: CH 4 dissociation level in microwave ECR plasma source by fibre-optic OES
PublikacjaSpatially resolved optical emission spectroscopy (SR-OES) was used to investigate microwave activated H2/Ar/CH4 plasma under conditions of the electron cyclotron resonance (ECR). The chemistry and composition of the gas phase were studied using self-designed fibre-optic system with echelle type spectrometer during CVD deposition of polycrystalline diamond. One-dimensional intensity profiles of the main species were collected along...
-
Roughness evaluation of turned composite surfaces by analysis of the shape of Autocorrelation Function
PublikacjaIn this paper, the application of an Autocorrelation Function for the characterisation of surface topography was validated. The roughness evaluation of turned composite surfaces was supported by sophisticated studies of the Autocorrelation Function properties, considering especially the shape of the function. Details were measured with the optical method. The selection of the surface roughness evaluation procedures was carried...
-
Optical sensor of a person sitting on a chair and dressed in multi-layered clothes vital signs monitoring
PublikacjaAn optoelectronic device enhancing a smart chair functionality is presented in the paper. Its essential purpose is a detection of a sitting person presence on the chair by means of detecting the vital signs. Additionally, it could be used for determining of clothes layer parameters useful in adjusting a system of a capacitive electrocardiography.
-
Optical recognition elements: macrocyclic imidazole chromoionophores entrapped in silica xerogel
PublikacjaMaterials containing new chromoionophores consisting of crown residue and azole moiety as partsof macrocycles were encapsulated by the sol-gel procedure in silica xerogel matrices and proposed aschemical recognition elements especially for such metal ions as Li+, Cs+ and Cu2+. Action of these recognition elements is in principle based on changes of reflectance. The recognition elements containing 21-membered chromogenic...