Filtry
wszystkich: 15410
wybranych: 10484
-
Katalog
- Publikacje 10484 wyników po odfiltrowaniu
- Czasopisma 437 wyników po odfiltrowaniu
- Konferencje 41 wyników po odfiltrowaniu
- Osoby 190 wyników po odfiltrowaniu
- Projekty 2 wyników po odfiltrowaniu
- Zespoły Badawcze 1 wyników po odfiltrowaniu
- Kursy Online 140 wyników po odfiltrowaniu
- Wydarzenia 2 wyników po odfiltrowaniu
- Dane Badawcze 4113 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: DISEASES , WAVELET TRANSFORMS , WAVELET ANALYSIS , GASTROINTESTINAL TRACT , ESOPHAGUS , SENSITIVITY , IMPEDANCE MEASUREMENT
-
Expedited Gradient-Based Design Closure of Antennas Using Variable-Resolution Simulations and Sparse Sensitivity Updates
PublikacjaNumerical optimization has been playing an increasingly important role in the design of contemporary antenna systems. Due to the shortage of design-ready theoretical models, optimization is mainly based on electromagnetic (EM) analysis, which tends to be costly. Numerous techniques have evolved to abate this cost, including surrogate-assisted frameworks for global optimization, or sparse sensitivity updates for speeding up local...
-
A measurement system for children endurance tests
PublikacjaThere are a lot of ethical problems concerning the use of invasive methods for the measurement of a child's body response to physical exercise and physical training. The alternative is are non-invasive methods like ergospirometry or NIRS. The article presents a measurement system dedicated for children endurance tests, composed of a few non-invasive measurement modules, including a temperature measurement module. Temperature is...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublikacjaThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublikacjaAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Coupling of Blood Pressure and Subarachnoid Space Oscillations at Cardiac Frequency Evoked by Handgrip and Cold Tests: A Bispectral Analysis
PublikacjaThe aim of the study was to assess blood pressure–subarachnoid space (BP–SAS) width coupling properties using time–frequency bispectral analysis based on wavelet transforms during handgrip and cold tests. The experiments were performed on a group of 16 healthy subjects (F/M; 7/9) of the mean age 27.2 ± 6.8 years and body mass index of 23.8 ± 4.1 kg/m². The sequence of challenges was first handgrip and then cold test. The handgrip...
-
Novel application of dynamic electrochemical impedance monitoring to a cataphoretic coating process
PublikacjaThe paper presents a novel method of on-line impedance monitoring of cataphoretic coating application process. Utilization of dynamic electrochemical impedance spectroscopy (DEIS) overcame the fundamental problem connected with non-stationarity of the aforementioned coating deposition process, which eliminates classical impedance spectroscopy technique from a real-time description of cataphoresis. The paper illustrates selected examples...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublikacjaThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Modeling of the fascia-mesh system and sensitivity analysis of a junction force after a laparoscopic ventral hernia repair
PublikacjaW pracy rozpatrywano prosty model cięgnowy układu powięż-siatka do oszacowania siły połączenia siatki z powięzią po operacji laparoskopowej przepukliny brzusznej. Cięgno obciążone jest ciśnieniem wewnątrz brzusznym, symulującym kaszel, oraz przemieszczeniami jego końców wywołanymi skłonami pacjenta. Wpływ poszczególnych parametrów cięgna na siłę połączenia określono za pomocą analizy wrażliwości. Sformułowano pewne wnioski ważne...
-
Oxygen sensitivity of hydrogenesis’ and methanogenesis’
PublikacjaIn the chapter, results of dark fermentation of sour cabbage in presence of oxygen with concentrations 2-9% are presented. The presence of oxygen in such concentration inhibits methanogesis (and methane production more than 2 times) and increases hydrogen production 6 times. It also shortens the fermentation process above 40%.
-
A measurement system for nonlinear surface spectroscopy with an atomic force microscope during corrosion process monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is espe-cially useful for heterogeneous...
-
Uncertainty of mass flow measurement using centric and eccentric orifice for Reynolds number in the range 10,000 ≤ Re ≤ 20,000
PublikacjaThe article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric (ISA) and eccentric, with the diameter ratio β = 0.5. Studies were performed by Monte Carlo simulation and experiments for Reynolds numbers in the range 10,000 ≤ Re ≤ 20,000. The obtained results have shown that for both orifice...
-
Optimization of the Relative Humidity of Reactant Gases in Hydrogen Fuel Cells Using Dynamic Impedance Measurements
PublikacjaWater management is a key factor affecting the efficiency of proton exchange membrane fuel cells (PEMFCs). The currently used monitoring methods of PEMFCs provide limited information about which processes or components that humidity has a significant impact upon. Herein, we propose the use of a novel approach of impedance measurements using a multi-sinusoidal perturbation signal, which enables impedance measurements under dynamic...
-
Effect of Time Varying Measurement Conditions on Antenna Pattern in Near Field Measurement and Its Correction Procedure
PublikacjaAuthors present the procedure of taking into account the changes of electrical parameters of setup due to the time drift of temperature during the procedure of near field measurement. It is proposed to make additional measurements in determined positions of probe are next used the results to introduce corrections terms in measured data. Such approach was verified practically in experimental near field measurement system.
-
Water uptake in protective organic coatings and its reflection in measured coating impedance
PublikacjaWater uptake in commercially available epoxy coating on mild steel using impedance spectroscopy and gravimetry was studied. The water content in the coating was determined using the Brasher-Kingsbury equation and various methods of coating capacitance calculation used in the literature. The obtained results were compared with reference gravimetric data. An overestimation of values obtained from impedance data in relation to gravimetric...
-
Analyzer for spectroscopy of low-impedance objects
PublikacjaW artykule przedstawiono analizator umożliwiający pomiar impedancji w zakresie 1 ohma < |Zx| < 100 Mohma. Zastosowano w nim nowe rozwiązania dotyczące obwodu wejściowego i techniki detekcji fazoczułej sygnałów pomiarowych. Obwód wejściowy zaprojektowano w postaci 5-zaciskowej sondy pomiarowej, która umożliwia ograniczenie wpływu rezystancji, indukcyjności i pojemności pasożytniczych na błąd pomiaru impedancji w szerokim przedziale...
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublikacjaIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Language specific spectra generated in the human vocal tract
Publikacja -
INFLUENCE OF WRONGLY ASSUMED PROBABILITY DISTRIBUTION ON THE UNCERTAINTY OF RESISTANCE MEASUREMENT BY TECHNICAL METHOD
PublikacjaThe paper presents studies on the influence of probability distributions on the expanded uncertainty of the resistance measurement. Choosing the correct probability distribution is very important to estimate of measurement uncertainty. The most commonly used distribution is the rectangular distribution. The paper presents the results of analysis of the resistance measurement uncertainty using the technical method of two resistances:...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublikacjaIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Iranian future healthcare professionals' knowledge and opinions about rare diseases: cross-sectional study
Publikacja -
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublikacjaDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Comparison of noise reduction methods in radiometric correlation measurements of two-phase liquid-gas flows
PublikacjaTwo-phase liquid-gas flows occur frequently in the mining, energy, chemical, and petrochemical industries. One of non-contact methods used to analyse these flows is the gamma ray absorption method. However, the signals received from radiation detectors contain a significant stochastic noise, which makes them difficult to analyse. The article describes four methods of noise reduction in cross-correlation measurements of water-air...
-
Efficient Multi-Fidelity Design Optimization of Microwave Filters Using Adjoint Sensitivity
PublikacjaA simple and robust algorithm for computationally efficient design optimiza-tion of microwave filters is presented. Our approach exploits a trust-region (TR)-based algorithm that utilizes linear approximation of the filter response obtained using adjoint sensitivity. The algorithm is sequentially executed on a family of electromagnetic (EM)-simulated models of different fidelities, starting from a coarse-discretization one, and...
-
Evaluation of Temperature Influence on Electrochemical Processes Occurring in a Lithium-Ion Supercapacitor with the Use of Dynamic Electrochemical Impedance Spectroscopy
PublikacjaIn order to obtain the full impedance characteristics of a lithium-ion capacitor as a function of temperature, the authors proposed the use of dynamic electrochemical impedance spectroscopy. Impedance tests were carried out under wide range of dynamic temperature changes for lithium-ion supercapacitors. Significant differences in electrochemical processes were observed as a result of working temperature. Moreover, the quality of...
-
Impedance of cation-coupled electron transfer reaction: Theoretical description of one pathway process
PublikacjaIt has been assumed that cation electron coupled charge transfer can be conducted in accordance with two mutually coupled reactions. Using a differential method an expression was introduced which describes the impedance of a cation electron coupled transfer reaction. Also, an electrical equivalent circuit has been defined. The total faradaic impedance is the sum of electron transfer impedance and cation transfer impedance. Issues...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
PublikacjaLocal impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 1016 to 2 × 1021 atoms cm−3. The BDD films displayed microcrystalline structure,...
-
Surgical site infection after gastrointestinal surgery in high-income, middle-income, and low-income countries: a prospective, international, multicentre cohort study
Publikacja -
Application of Impedance Spectroscopy for Bi1−xNdxFeO3 Ceramics Characterization
PublikacjaIn the present paper the synthesis conditions for fabrication of Bi1−xNdxFeO3 ceramics are reported. The single phase polycrystalline samples of Bi1−xNdxFeO3 were prepared by standard solid state reaction method from the mixture of oxides viz.: Bi2O3, Fe2O3 and Nd2O3. The samples were characterized by impedance spectroscopy in the frequency range 10Hz – 1MHz at room temperature.
-
Nonlinear impedance in oxide glasses containing single and mixed alkali ions
PublikacjaThe aim of the present was to find more clues on the nonlinearities in impedance of oxide glasses. The first family of researched glasses has a composition of FeO-P2O5-Na2O. Oxide glasses containing iron and alkali are well known for a very low alkali ion mobility and may be considered purely polaron conducting. These glasses show no detectable nonlinearities in the impedance spectra. The second was a family of ionic conducting...
-
Effects of Non-Opioid Analgesics on the Cell Membrane of Skin and Gastrointestinal Cancers
Publikacja -
Bariatric surgery and incidental gastrointestinal stromal tumors – a single-center study
Publikacja -
Distribution of relaxation times as a method of separation and identification of complex processes measured by impedance spectroscopy
PublikacjaImpedance spectroscopy is one of the most commonly performed measurements to characterize electronic and electrochemical systems. Impedance spectra have limited resolution and many different processes may overlap what could be the reason of obstructions in its proper later analysis. Up to date, there are three approaches to solve this problem: examining impedance spectra itself, fitting spectra with equivalent circuits, and calculating...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublikacjaThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Cyclic analysis of thermal impedance of a passive layer of aluminium in a neutral borate buffer solution
PublikacjaW pracy przedstawiono wyniki badań warstwy pasywnej tworzącej się na stopie 1050 A w warunkach zmieniającej się temperatury. Zmiany realizowano w sposób cykliczny zwiększając a następnie zmniejszając temperaturę. W czasie zmian temperatury prowadzono badania metodę dynamicznej elektrochemicznej spektroskopii impedancyjnej. Stwierdzono największe zmiany parametrów elektrycznego schematu zastępczego w czasie pierwszego cyklu zmian....
-
Electrochemical properties of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes in solid oxide cells: Impedance study of symmetrical electrodes
PublikacjaThis work evaluates porous Sr0.86Ti0.65Fe0.35O3 (STF35) as a possible oxygen electrode material for Solid Oxide Cells. The powder synthesis was performed by solid state method. Characterization included DC electrical conductivity study of sintered bulk samples and impedance spectroscopy study of symmetrical electrodes deposited on gadolinium doped ceria substrates. Measurements were carried out in atmospheres with different pO2...
-
Towards spectral sensitivity curve for two-photon vision mechanism
PublikacjaAbstract Purpose: The perceived brightness of different visible light sources can be compared with photometric units based on the standardized luminosity curves (300-780nm range). As reported previously (PNAS 111(50), pp. E5445-E5454 (2014)), near-infrared (NIR) radiation can cause isomerization of visual pigments by one- or two-photon absorption. The perceived color of the stimulus is red in the case of one-photon vision (1PV)...
-
Wireless Body Area Network for Preventing Self-Inoculation Transmission of Respiratory Viral Diseases
PublikacjaThis paper proposes an idea of Wireless Body Area Networks (WBANs) based on Bluetooth Low-Energy (BLE) standards to recognize and alarm a gesture of touching the face, and in effect, to prevent self-inoculation of respiratory viral diseases, such as COVID-19 or influenza A, B, or C. The proposed network comprises wireless modules placed in bracelets and a necklace. It relies on the received signal strength indicator (RSSI) measurements...
-
Testing sensitivity of A-type residual current devices to earth fault currents with harmonics
PublikacjaIn many applications, modern current-using equipment utilizes power electronic converters to control the consumed power and to adjust the motor speed. Such equipment is used both in industrial and domestic installations. A characteristic feature of the converters is producing distorted earth fault currents, which contain a wide spectrum of harmonics, including high-order harmonics. Nowadays, protection against electric shock in...
-
MEASUREMENT AND ANALYSIS OF A FLOOD WAVE PROPAGATION ON THE KACZA RIVER IN GDYNIA IN NORTHERN POLAND
PublikacjaKacza river is located in northern Poland in the neighborhood of the Gulf of Gdansk and the Baltic Sea. A Kacza having length of 15 km and catchment area of 53 km2 collects the water into the Gulf mostly from inhabited and forested areas within the administrative boundaries of the city of Gdynia. On the 14th and 15th of July 2016 in northern Poland on the large area of Tri-City agglomeration (Gdynia, Gdansk and Sopot) total daily...
-
Energy Recovery Analysis in A-Type Pressure Regulation and Measurement Stations in Istanbul, Esenyurt
Publikacja -
Glycyrrhetinic acid and its derivatives in infectious diseases
Publikacja -
The high impedance measuring probe for gain-phase analysers.
PublikacjaAutorzy opracowali tanią sondę pomiarową przeznaczoną do pracy z analizatorami gain-phase jak Solartron 1260 Impedance/Gain-phase Analyser, 1255 Frequency Response Analyser (FRA) lub starszymi wersjami 1250, 1253. Przedstawiona architektura sondy wyznacza jej parametry metrologiczne. Pomiary możliwe są w 8 zakresach obejmujących wartości 100ohm<|Zx|<100Gohm w szerokim zakresie częstotliwości 10uHz-1MHz. Obwód wejściowy sondy pozwala...
-
USE OF LANGMUIR PROBE IN DIESEL ENGINE DIAGNOSTIC RESEARCH Part I MEASUREMENT TECHNOLOGY. - Part 1 : MEASUREMENT TECHNOLOGY
PublikacjaIn the paper, the basic assumptions of diesel engine cylinder system's diagnosing method, based on observation of emerging and moving electric charges of ionized gas in the combustion workspaces, using Langmuir's probe. In the first part of the paper, only the technology of the measurement and results of the preliminary diagnostic tests of laboratory engine Farymann Diesel D10 were presented. The primary purpose of the research...
-
Distance measurement errors in silent FM-CW sonar with matched filtering
PublikacjaThe secretiveness of sonar operation can be achieved by using continuous frequency-modulated sounding signalswith reduced power and significantly prolonged repeat time. The application of matched filtration in the sonarreceiver provides optimal conditions for detection against the background of white noise and reverberation, and avery good resolution of distance measurements of motionless targets. The article shows that target...
-
Goblet Cell Ratio in Combination with Differentiation and Stem Cell Markers in Barrett Esophagus Allow Distinction of Patients with and without Esophageal Adenocarcinoma
Publikacja -
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublikacjaRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Simulation of static response of thin walled bars with changed design parameters by means of second order sensitivity analysis.
PublikacjaZa pomocą analizy wrażliwości drugiego rzędu wyznaczono przybliżone wartości sił wewnętrznych i przemieszczeń pręta cienkościennego dla zmieniających się parametrów projektowych. W przykładzie numerycznym wyznaczono pierwszą i drugą wariację bimomentu w funkcji grubości półek skręcanego dwuteownika. Zbadano dokładność rozwiązania uzyskanego za pomocą analizy wrażliwości z rozwiązaniem ścisłym.
-
Dynamic impedance measurements of the Direct Methanol Fuel Cell cathode at various operating temperatures
PublikacjaThis article discusses the application of impedance analysis for diagnosing the cathode of a direct methanol fuel cell at various operating temperatures. The Dynamic Electrochemical Impedance Spectroscopy technique coupled with a linear current scan was applied for this purpose. This technique allowed the observation of changes in the cathode's properties in the fuel cell operating under real working conditions. An equivalent model...
-
The Influence of Thin Gold Electrodes on the High-Temperature Impedance of Oxide Glasses
PublikacjaThe influence of thin gold electrodes on the electrical measurements of glasses at high temperatures was studied using impedance spectroscopy. The impedance was measured several times over a wide frequency range from 10 mHz to 1 MHz and the temperature ranged from 213 to 673 K under air and nitrogen atmospheres. The results showed a drop in the conductivity of more than an order of magnitude at a temperature around 603 K during...
-
Applicability of an effective conductivity approach in modeling thoracic impedance changes
PublikacjaThis paper describes numerical simulations of the influence of conductivity changes inside a volume conductor on impedance changes measured on its surface. A simple model based on the finite element method has been developed to estimate an applicability of the effective conductivity theory in human chest modeling. The model consisted of a cylinder with two concentric spheres inside. Simulations were performed for two cases: first...