Wyniki wyszukiwania dla: STRUCTURE MONITORING
-
In-situ monitoring of electropolymerization processes at boron-doped diamond electrodes by Mach-Zehnder interferometer
PublikacjaIn this work, the Mach-Zehnder interferometer was designed to monitor the electrochemical processes conducted at boron-doped diamond electrode surface. The diamond electrodes were synthesized via Microwave Plasma-Assisted Chemical Vapor Deposition on optical grade quartz glass. The achieved transmittance in working are of diamond electrodes reached 55 %. A cage system-based Mach-Zehnder interferometer was used which allowed the...
-
The electrochemical determination of isatin at nanocrystalline boron-doped diamond electrodes: stress monitoring of animals
PublikacjaUltra-thin nanocrystalline boron-doped diamond electrodes (B:NCD) were used for the electrochemical determination of isatin in dog urine samples using cyclic voltammetry and square wave voltammetry in a phosphate buffer saline, pH = 7.2. No additional modification or pretreatment of the electrode surface was required in this approach, being of high importance for the facile detection procedure. The increase of the peak current...
-
Monitoring of deep foundation deflection in model experiments by means of a magnetic method: theoretical study.
PublikacjaZaproponowano oryginalną nieinwazyjną metodę pomiaru ugięcia pali bocznie obciążonych niespoistymi i małospoistymi gruntami suchymi lub wilgotnymi. Metoda ma zastosowanie do pomiaru ugięcia pali i ścian szczelnych oraz określania położenia innych fundamentów lub elementów zagłębionych w gruncie.
-
Perspectives on developing an automated monitoring system for the EBPR process - experiences from a pilot WWTP.
PublikacjaZaburzenia procesu biologicznego usuwania fosforu (BUF) są często spowodowane rozcieńczeniem ścieków w wyniku dopływu wód opadowych. Podobne efekty zaobserwowano w trakcie serii badań przeprowadzonych w pilotowej oczyszczalni ścieków Hanower-Gummerwald. Celem tych badań było określenie maksymalnej przepustowości hydraulicznej obiektu. Wyniki badań zostały wykorzystane do opracowania systemu automatycznego monitoringu procesu BUF...
-
Novel method of initiation stage of stress corrosion cracking monitoring with respect to marine constructions
PublikacjaKorozja konstrukcji morskich i jednostek pływających stanowi bardzo ważny problem w odniesieniu do aspektów bezpieczeństwa, gdyż w całym okresie eksploatacji narażone są na działanie bardzo agresywnego środowiska i innych czynników eksploatacyjnych. W rezultacie prowadzi to do niespodziewanych kolizji i wypadków. Praca przedstawia zastosowanie dynamicznej elektrochemicznej spektroskopii impedanycjnej (DEIS) do badania inicjacji...
-
Settlement of a historic building due to seepage-induced soil deformation
PublikacjaThe research paper reviews issues associated with the impact of groundwater flow on soil characteristics and parameters, hence, the entire structure of a building set on it. Water seepage through the ground, building subsoil or structural elements of buildings made of soil affects the soil skeleton and may lead to changes in the arrangement of individual grains relative to each other, i.e., a modified soil structure. Soil solid...
-
Importance of artificial intelligence to support the process of anaerobicdigestion of kitchen waste with bioplastics / Znaczenie sztucznej inteligencji we wspomaganiu procesu beztlenowej fermentacji odpadów kuchennych zawierających bioplastiki
PublikacjaArtificial intelligence (AI) and machine learning were used to obtain more effective methods for conducting the digestion process and achieving final products. Data acquisition was carried out by an automatic monitoring and anal. research. The knowledge describing the anaerobic digestion process was summarized in the form of rules: IF (premise) THEN (conclusion). The compiled set of rules created a knowledge base of the expert...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
Publikacja -
The use of terrestrial laser scanning in monitoring and analyses of erosion phenomena in natural and anthropogenically transformed areas
Publikacja -
Intraoperative monitoring of cerebral NIRS oximetry leads to better postoperative cognitive performance: A pilot study
Publikacja -
Effect of housing geometry on the performance of Chemcatcher passive sampler for the monitoring of hydrophobic organic pollutants in water
PublikacjaZaprojektowano nową obudowę próbnika typu Chemcatcher, tzw. próbnik typu Chemcatcher drugiej generacji. Większość badań kalibracyjnych przeprowadzono stosując próbnik typu Chemcatcher pierwszej generacji. Dlatego zbadano wpływ obudowy próbnika typu Chemcatcher na jego działanie.
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublikacjaA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
Planowanie zintegrowane i monitoring rozwoju zrównoważonego obszarów lokalnych a ich zagospodarowanie dla turystyki
PublikacjaPrzez planowanie zintegrowane rozumie się planowanie kompleksowe, wieloaspektowe, łączące aspekty społeczno-gospodarcze i ekologiczne z aspektami przestrzennymi. Autorzy prezentują ideę rozwoju zrównoważonego, typy obszarów wiejskich i formy planowania w polskich gminach. Proponują zintegrowane planowanie rozwoju obszaru turystycznego. Formułują postulaty co do monitoringu rozwoju zrównoważonego obszarów lokalnych oraz sposobu...
-
The impact of an electronic monitoring and reminder device on patient compliance with antihypertensive therapy: a randomized controlled trial
Publikacja -
Static renewal and continuous-flow calibration of two types of passive samplers for the monitoring of pharmaceuticals in wastewater
Publikacja -
Assessment of respiratory responses to emotional virtual reality stimuli with non-contact respiration monitoring system
Publikacja -
Continuous Monitoring of Thermooxidative Degradation Products of Polystyrene by Membrane Extraction with Sorbent Interface and Gas Chromatography
Publikacja -
Privacy-Preserving, Scalable Blockchain-Based Solution for Monitoring Industrial Infrastructure in the Near Real-Time
Publikacja -
Automated analyser for monitoring trace amounts of volatile chloro-organic compounds in recirculated industrial water
PublikacjaOpisano konstrukcję oraz badania laboratoryjne modelu nowego automatycznego analizatora śladowych ilości lotnych związków chlorowco-organicznych w wodzie do celów przemysłowych (o wysokiej czystości). Praca analizatora oparta jest na: - przeciwprądowym ciągłym wypłukiwaniu analitów ze strumienia próbki, - okresowym zatrzymywaniu uwolnionych analitów na złożu sorbenta, - desorpcji termicznej, - oznaczaniu sumy związków chlorowco-organicznych...
-
Real-time monitoring of the emission of volatile organic compounds from polylactide 3D printing filaments
PublikacjaEstablishing the emission profile of volatile organic compounds generated during fused deposition modeling 3D printing using polymer filaments is important in terms of both understanding the processes taking place during thermal degradation of thermoplastics, and assessing the user's exposure to potentially harmful volatiles. However, obtaining detailed, real-time qualitative and quantitative results poses a challenge. In this...
-
Continuous blood pressure monitoring by photoplethysmography - signal preprocessing requirements based on blood flow modelling
PublikacjaObjective. The aim of the study is to investigate the effect of the signal sampling frequency and low-pass filtering on the accuracy of the localisation of the fiducial points of the photoplethysmographic signal (PPG), and thus on the estimation of the blood pressure (i.e. the accuracy of the estimation). Approach. Statistical analysis was performed on 3,799 data samples taken from a publicly available database. Four PPGfiducial...
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublikacjaCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Monitoring technologicznych ram zabezpieczenia przejść poprzecznych tunelu pod Martwą Wisłą w Gdańsku
PublikacjaPraca dotyczy systemu pomiarowego zastosowanego podczas monitoringu ram technologicznych wspierających drążenie przejść poprzecznych łączących oba główne korytarze tunelu pod Martwą Wisłą w Gdańsku. W pracy przedstawiono wyniki badań dwóch typów ram, uzyskane podczas wykonywania dwóch przejść. Wyniki pomiarów pozwalają na określenie stanu wytężenia konstrukcji ram w czasie prowadzenia robót oraz na oszacowaniu rzeczywistego stanu...
-
Adapting a General Tool to Monitoring Multi-Agent Systems Through Virtual Host Layer Extenstion
PublikacjaNagios is a free software for IT infrastructure monitoring. Out-of-the-box it is not suited for monitoring multi-agent systems, because agents may dynamically join and leave the system or change roles. But Nagios' flexible configuration makes extensions possible. This paper presents and verifies Nagios configuration and extensions for monitoring multi-agent systems.
-
A measurement system for nonlinear surface spectroscopy with an atomic force microscope during corrosion process monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is espe-cially useful for heterogeneous...
-
Optoelektroniczny monitoring stanu wzbudzenia plazmy niskotemperaturowej w procesach syntezy optycznych warstw diamentopodobnych
PublikacjaZrealizowana praca jest jednym z głównych zadań wieloletniego projektu badawczego z zakresu syntezy warstw diamentopodobnych. Celem bezpośrednim pracy było określenie rozkładu wzbudzenia plazmy w komorze technologicznej stanowiska PA ECR CVD. Głównym celem było opracowanie optoelektronicznego systemu pomiarowego, na którego potrzeby zastosowano przestrzennie selektywną optyczną spektroskopię emisyjną dedykowaną do badania procesu...
-
Monitoring of volatile organic compounds (VOCs) in atmospheric air. Part I. On-line gas analyzers
PublikacjaThe paper reviews the subject literature concerning the analytical instruments routinely used for monitoring volatile organic compounds in atmospheric air. The analyzers are classified as stationary or mobile according to their ease of transport. Stationary DOAS (Differential Optical Absorption Spectroscopy) analyzer is characterized, as are MIMS (Membrane Introduction Mass Spectrometry), MESI (Membrane Extraction with Sorbent...
-
Monitoring of volatile organic compounds (VOCs) in atmospheric air. Part II. Sample collection and preparation
PublikacjaThe paper reviews literature information on air sampling techniques commonly used for monitoring volatile organic compounds (VOCs) levels in atmospheric air. It describes containers for collecting samples of atmospheric air, such as vacuum canisters and bags made from synthetic materials. It discusses dynamic, passive and denudational techniques for sampling analytes from air combining isolation with preliminary enrichment, and...
-
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publikacja -
Process Monitoring in Heavy Duty Drilling Rigs—Data Acquisition System and Cycle Identification Algorithms
Publikacja -
Prediction of NOx Emission Based on Data of LHD On-Board Monitoring System in a Deep Underground Mine
Publikacja -
A randomized and controlled study of noninvasive hemodynamic monitoring as a guide to drug treatment of uncontrolled hypertensive patients
Publikacja -
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Multi-sensor monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in utility water installations
PublikacjaThis paper presents an implementation of the monitoring of the corrosion rate and the assessment of the efficiency of a corrosion inhibitor in a utility water installation using an automated corrosion monitoring system. Due to the fact that the corrosion inhibitor was added to water intended for human consumption, it was necessary to build a multi-sensor monitoring system. In order to implement corrosion monitoring using a linear...
-
Evaluation of the use of reindeer droppings for monitoring essential and non-essential elements in the polar terrestrial environment
PublikacjaExcess or toxic metals, non-metals and metalloids can be eliminated from the organism by deposition in inert tissue (e.g. fur) or excretion with body secretions, urine and faeces. Droppings are one of the main routes for the elimination of multiple elements and they can be collected without direct contact with the animal. Contaminant concentration has been examined in non-lethally collected tissues of several species (especially...
-
Implementation of spatial information for monitoring and analysis of the area around the port using laser scanning techniques
PublikacjaNowadays, maritime infrastructure is heavily exploited, which requires monitoring. The article presents the implementation of spatial information which are point clouds for monitoring and analysis of the area around the port (buildings and wharves). For this study, point clouds coming from terrestrial (TLS) and airborne laser scanning (ALS), each of them having different accuracy, were used. An important part of the analysis was...
-
The central server of the Border Guard's distributed multimedia system for monitoring and visualisation of ongoing and archival events
PublikacjaThe paper presents the architecture and functionalities of the central server (CENTER) of the distributed system for the Polish Border Guard (BG) for monitoring maritime areas. The overall system has been extended to incorporate, apart from map data, also different multimedia elements such as video from cameras or audio from telephone connections operated by BG units. This requires new system elements: Archive Servers for storing...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublikacjaThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Energy consumption optimization in wastewater treatment plants: Machine learning for monitoring incineration of sewage sludge
PublikacjaBiomass management in terms of energy consumption optimization has become a recent challenge for developed countries. Nevertheless, the multiplicity of materials and operating parameters controlling energy consumption in wastewater treatment plants necessitates the need for sophisticated well-organized disciplines in order to minimize energy consumption and dissipation. Sewage sludge (SS) disposal management is the key stage of...
-
The Physical Activity Environment Policy Index for monitoring government policies and actions to improve physical activity
PublikacjaBackground A multifaceted response, including government action, is essential to improve population levels of physical activity (PA). This article describes the development process of the ‘Physical Activity Environment Policy Index’ (PA-EPI) monitoring framework, a tool to assess government policies and actions for creating a healthy PA environment. Methods An iterative process was undertaken. This involved a review of policy...
-
Microcracking monitoring and damage detection of graphene nanoplatelets-cement composites based on acoustic emission technology
PublikacjaThis study aims to identify the micro-cracking pattern and structural applications of cement composites replaced with 0 wt%, 0.04 wt%, and 0.08 wt% contents of graphene nanoplatelets (GNPs) over cement weight through acoustic emission (AE) monitoring under mechanical degradation. The ultraviolet-visible spectroscopy (UV–vis) results showed that at 60 min sonication period, GNP-4 showed maximum absorbance rate of 16.15% compared...
-
Real-time isothermal DNA amplification monitoring in picoliter volumes using an optical fiber sensor
PublikacjaRolling circle amplification (RCA) of DNA can be considered as a great alternative to the gold standard polymerase chain reaction (PCR), especially during this pandemic period, where rapid, sensitive, and reliable test results for hundreds of thousands of samples are required daily. This work presents the first research to date on direct, real-time and label-free isothermal DNA amplification monitoring using a microcavity in-line...
-
Real-time monitoring of volatiles and particles emitted from thermoplastic filaments during 3D printing
PublikacjaPresentation on the use of instrumental analytical techniques for the assessment of emission of volatiles and particulates during fdm 3d printing.
-
Nadmierne osiadania nawierzchni drogowej w ujęciu geotechnicznym - przyczyny, monitoring, możliwe metody naprawy
PublikacjaNadmierne osiadania nawierzchni stanowią „wieczny” problem użytkowników dróg. Z odkształceniami nawierzchni łączy się obniżenie komfortu i bezpieczeństwa jazdy (BRD). Jedną z podstawowych przyczyn takiego zjawiska jest zachowanie się podłoża gruntowego. Najczęściej dotyczy to zjawiska osiadania podłoża gruntowego, stanowiącego efekt ściśliwości gruntów w wyniku przyłożenia obciążenia i jest przekroczeniem stanów granicznych użytkowalności...
-
Nadmierne osiadania nawierzchni drogowej w ujęciu geotechnicznym – przyczyny, monitoring, możliwe metody naprawy
PublikacjaNadmierne osiadania nawierzchni stanowią „wieczny” problem użytkowników dróg. Z odkształceniami nawierzchni łączy się obniżenie komfortu i bezpieczeństwa jazdy (BRD). Jedną z podstawowych przyczyn takiego zjawiska jest zachowanie się podłoża gruntowego. Najczęściej dotyczy to zjawiska osiadania podłoża gruntowego, stanowiącego efekt ściśliwości gruntów w wyniku przyłożenia obciążenia i jest przekroczeniem stanów granicznych użytkowalności...
-
A framework for onboard assessment and monitoring of flooding risk due to open watertight doors for passenger ships
PublikacjaPost-accident safety of ships is governed by damage stability, affected by watertight subdivisions which limit accidental flooding. This is important for passenger ships with watertight doors (WTDs) often fitted in the bulkheads. Awareness of the ship flooding risk due to open WTDs and the conditions under which the associated risk level changes are prerequisites for proactive risk mitigation. Accident risk is often expressed as...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublikacjaAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Integration Data Model of the Bathymetric Monitoring System for Shallow Waterbodies Using UAV and USV Platforms
PublikacjaChanges in the seafloor relief are particularly noticeable in shallow waterbodies (at depths up to several metres), where they are of significance for human safety and environmental protection, as well as for which the highest measurement accuracy is required. The aim of this publication is to present the integration data model of the bathymetric monitoring system for shallow waterbodies using Unmanned Aerial Vehicles (UAV) and...
-
Monitoring Regenerative Heat Exchanger in Steam Power Plant by Making Use of the Recurrent Neural Network
PublikacjaArtificial Intelligence algorithms are being increasingly used in industrial applications. Their important function is to support operation of diagnostic systems. This paper pesents a new approach to the monitoring of a regenerative heat exchanger in a steam power plant, which is based on a specific use of the Recurrent Neural Network (RNN). The proposed approach was tested using real data. This approach can be easily adapted to...
-
The added value of using the HEPA PAT for physical activity policy monitoring: a four-country comparison
PublikacjaBackground Public policy is increasingly recognized as an important component of physical activity promotion. This paper reports on the current status of physical activity policy development and implementation in four European countries based on the Health-Enhancing Physical Activity Policy Audit Tool (HEPA PAT) developed by WHO. It compares the findings to previous studies and discusses the general utility of this tool and its...