Wyniki wyszukiwania dla: POWER MEASUREMENT
-
Field Tests on Hydrodynamic and Hybrid Operation of a Bidirectional Thrust Bearing of a Pump-Turbine
PublikacjaIn vertical shaft pump turbines operating in pumped storage power plants an important role is played by a thrust bearing. Due to the bidirectional character of operation, thrust bearing tilting pads have to be supported symmetrically, which is known to be unfavourable from the point of view of their performance. Large thrust bearings have to be carefully designed so as to minimise excessive thermo-elastic pad deformations. The...
-
Measurements of no-load and short-circuit parameters of power transformers with taps
Dane Badawcze1) The Laboratory LINTE^2 is a large research infrastructure operated by the Faculty of Electrical and Control Engineering at Gdańsk University of Technology, to be found in Gdańsk, Poland (54.3690 N, 18.6130 E).
-
Downlink Capacity-Coverage Trade-off Estimation Based on Measurement of WCDMA/FDD Interface Load
PublikacjaThe method of capacity-coverage trade-off determination by using of universal load characteristics and normalized coverage curves for the WCDMA/FDD radio interface has been presented. The practical applications of discussed method for UMTS radio network planning process and network exploitation has been mentioned.
-
Old-timer Vehicle - Braking Efficiency Measurement at Vehicle Inspection Stations and Roadworthiness Validity Certificate.
PublikacjaObtaining the Roadworthiness Validity Certificate for an old-timer vehicle involves an appropriate test performance, namely, "Old-timer Vehicle Technical Specification Compliance Test". It seems obvious that this kind of test should include a considerable checklist, however, the current legal regulations connected with this test are not specific enough. One of the certificates issued on this test results is "Old-timer Vehicle Technical...
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublikacjaThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
A measurement system for nonlinear surface spectroscopy with an atomic force microscope during corrosion process monitoring
PublikacjaIn addition to traditional imaging the surface, atomic force microscopy (AFM) enables wide variety of additional measurements. One of them is higher harmonic imaging. In tapping mode the nonlinear contact between tip and specimen results in higher frequency vibrations. More information available from the higher harmonics analysis proves to be helpful for more detailed imaging. Such visualization is espe-cially useful for heterogeneous...
-
Myrosinase activity in different plant samples; optimisation of measurement conditions for spectrophotometric and pH-stat methods
PublikacjaMyrosinase found in Brassicaceae plants, is the enzyme responsible for hydrolysis of glucosinolates. As a result a variety of biologically active metabolites are liberated, whose importance in crop protection and especially in cancer chemoprevention is rapidly gaining recognition. The growing practical application of glucosinolate degradation products requires that sensitive and reliable methods of myrosinase activity determination...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublikacjaThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublikacjaOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Measurement of idlers rotation speed in belt conveyors based on image data analysis for diagnostic purposes
Publikacja -
Software-based method of increasing the effective resolution of a measurement chain for a transducer with a pulse frequency output
Publikacja -
An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples
Publikacja -
Automatic resource identification for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard
Publikacja -
Research Protocol of the Polish Adaptation and Validation of HOPE Scale: Qualitative Measurement of Patients' Spiritual Needs
Publikacja -
THE APPLICATION OF BALANCED SCORECARD METHOD FOR THE SELECTION OF FACTORS USED IN THE EFFICIENCY MEASUREMENT OF PUBLIC HOSPITALS IN POLAND
Publikacja -
Human and Methodological Sources of Variability in the Measurement of Urinary 8-Oxo-7,8-dihydro-2′-deoxyguanosine
Publikacja -
Urinary Measurement of 8-OxodG, 8-OxoGua, and 5HMUra: A Noninvasive Assessment of Oxidative Damage to DNA
Publikacja -
Optoelectronic properties of the metal-tetracene interface investigated by current noise measurement under monochromatic irradiation.
PublikacjaZaprezentowano badania prądów ograniczonych elektrodowo w warstwach tetracenu. Szczególną uwagę zwrócono na zależność szumów elektrycznych od przyłożonego napięcia i padającego światła.
-
MEASUREMENT AND ANALYSIS OF ELECTRIC FIELD INTENSITY NEAR SELECTED TRANSMITTERS OF MOBILE TELEPHONY BASE STATIONS
PublikacjaWireless connectivity has become increasingly common in recent times. Day by day, there are more radiocommunication devices and new ideas for them. In the near future, when the fifth generation networks will be implemented, whose main feature will be continuous wireless communication, we must approach the issue of electric field measurements more and more carefully.
-
Quantum Steering Inequality with Tolerance for Measurement-Setting Errors: Experimentally Feasible Signature of Unbounded Violation
Publikacjauantum steering is a relatively simple test for proving that the values of quantum-mechanical measurement outcomes come into being only in the act of measurement. By exploiting quantum correlations, Alice can influence — steer — Bob ’ s physical system in a way that is impossible in classical mechanics, as shown by the violation of steering inequalities. Demonstrating this and similar quantum effects for systems of increasing size,...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublikacjaMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
Investigations of the Methods of Time Delay Measurement of Stochastic Signals Using Cross-correlation with the Hilbert Transform
PublikacjaThe article presents the results of simulation studies of four methods of estimating time delay for random signals using cross-correlation with the Hilbert Transform. Selected models of mutually delayed stochastic signals were used in the simulations, corresponding to the signals obtained from scintillation detectors in radioisotope measurements of liquid-gas two-phase flow. Standard deviations of the values of the individual functions...
-
High-quality Experiment Dedicated to microGravity Exploration, Heat Flow and Oscillation Measurement from Gdańsk
PublikacjaIn this paper we propose HEDGEHOG (High-quality Experiment Dedicated to microGravity Exploration, Heat flow and Oscillation measurement from Gdańsk) REXUS experiment to investigate vibrational and heat flow phenomena during the whole (ascent, microgravity phase, descent and recovery) flight of a sounding rocket. First, a proposed system of cantilever beams is discussed to study dynamic behaviour of dummy payload. Dimensioning has...
-
A Computational Analysis of the Aerodynamic and Aeromechanical Behavior of a Thermo-Well for Steam Temperature Measurement in a Steam Turbine
PublikacjaThe goal of the paper is twofold: firstly, it presents computational fluid dynamics analysis for finding maximum unsteady flow forces (and their frequencies) acting on a thermo-well for measuring steam temperature in a steam turbine control stage and secondly, it presents computational solid dynamics analysis of possibility of entry into resonance of the thermowell structure. There have been analyzed two cases of flow with changing...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublikacjaAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Measurement of the Temporal and Spatial Temperature Distribution on the Surface of PVCP Tissue Phantom Illuminated by Laser Dataset
PublikacjaThe dataset entitled Measurement of the temporal and spatial temperature distribution on the surface of PVCP tissue phantom illuminated by laser was obtained with a laboratory set-up for characterisation of the thermal properties of optical tissue phantoms during laser irradiation. The dataset contains a single image file representing the spatial temperature distribution on the surface of a PVCP tissue phantom. This thermal image...
-
Fatigue life improvement using low transformation temperature weld material with measurement of residual stress
PublikacjaWelding processes often produce high levels of tensile residual stress. Low transformation temperature (LTT) welding wires utilise phase transformation strains to overcome the thermal contraction of a cooling weld. In this paper, the residual stress within each weld was quantified using the milling/strain gauge method, being the strain change measured as the weldment was milled away. The fatigue tests were conducted under uniaxial...
-
Diamond protection for reusable ZnO coated fiber-optic measurement head in optoelectrochemical investigation of bisphenol A
PublikacjaDue to the global problem with plastic contaminating the environment, with bisphenol A (BPA) being one of the highest demand, effective monitoring and purification of the pollutants are required. The electrochemical methods constitute a good solution but, due to polymerization of electrochemical oxidation bisphenol A products and their adsorption to the surfaces, measurement head elements are clogged by the formed film. In this...
-
Application of electrical capacitance tomography (ECT) to measurement of sand concentration changes during silo flow
PublikacjaW artykule przedstawiono wyniki doświadczeń pomiaru zmian koncentracji materiału granulowanego podczas przepływu silosowego. Zmiany zostały pomierzone przy pomocy tomografu. Doświadczenia wykonano w silosie cylindrycznym dla 2 różnych szorstkości ścian.
-
Study of the optical rotatory of potassium titanyl phosphate using the advanced dual-wavelength polarimetric method
PublikacjaA dual-wavelength high-accuracy universal polarimeter was applied to the circular birefringence and optical activity measurement in potassium titanyl phosphate (KTP) nonlinear crystal. The experimental setup used two single-mode He-Ne lasers with close wavelengths of 594 and 633 nm as light sources. Measurement has been carried out for two crystal settings in directions of a 45-degree relative angle to the [100] and [010] crystallographic...
-
Subjective and Objective Quality Evaluation Study of BPL -PLC Wired Medium
PublikacjaThis paper presents results of research on the effectiveness of bi-directional voice transmission in a 6 kV mine cable network using BPL-PLC (Broadband over Power Line - Power Line Communication) technology. It concerns both emergency cable state (supply outage with cable shorted at both ends) and loaded with distorted current waveforms. The narrowband (0.5 MHz–15 MHz) and broadband (two different modes, frequency range of 3 MHz–7.5...
-
Sensors integration in the smart home environment - a proposal to solve the problem with user identification
PublikacjaIn this preliminary study we, investigate the possibility of user recognition techniques suitable on smart home devices like chairs, beds, aiming for low–power, high accuracy and quick response time. We propose the two well know technique: voice speaker recognition and accelerometer signal from device mounted on the chair, and the third one optical system basing on IR LED transmitter/receiver circuit. The preliminary results proved...
-
The electromagnetic field intensity in industrial buildings
Dane BadawczeThe dataset contains the results of measurements of electromagnetic fields, separately electric and magnetic, carried out at selected places in the building of an operating industrial enterprise.
-
Leakage Current Measurements of Surge Arresters
PublikacjaThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
Diagnostics of induction motor bearings - possibility of measurements
PublikacjaIn induction motors damage in the elements of electromagnetic system, for example in the wiring of stator, rotor or in the magnetic circuit can appear as well as damage of mechanical parts (bearings, rotor, shaft). Bearing diagnostics is so important in supervision of motor condition, because extensive research shows that the bearings arethe elements most susceptible to damage. This paper presents the research which the author...
-
Mobile Networks' Analysis in Terms of QoS Performance Assessment
PublikacjaQuality of service (QoS) assessment is one of the basic processes carried out by mobile network operators (MNOs) and regulators of the telecommunications market. Usually, professional companies carry out measurements for various country areas and use cases (scenarios). In this paper, we show exemplary measurement results carried out in drive tests in the vicinity of the Polish capital by a professional company. The measurement...
-
Miniaturized impedance analyzer using AD5933
PublikacjaThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
Miniaturized impedance analyzer using AD5933
PublikacjaThe paper presents the analyzer allowing to measure impedance in a range of 10 ohms <|Zx|<10 Gohms in a wide frequency range from 10 mHz up to 100 kHz. The device specific features are: miniaturization, low power consumptions and the use of impedance measurement method based on DSP. These features were possible thanks to the use of newest generation of large scale integration chips: e.g. „system on a chip” microsystems (AD5933)...
-
The assessment of metrological properties of segmental orifice based on simulations and experiments
PublikacjaSegmental orifices are often used to measure flows of heterogeneous mixtures, especially in flow meters in the power industry, for example. The orifice (with module m= 0.25) was installed in a stainless-steel pipe with internal diameter of 50 mm, placed in a hydraulic water system. The research was performed for Reynolds numbers ranging from 9,000 to 17,000. The flow characteristics of this orifice obtained based on simulation...
-
Will NILM Technology Replace Multi-Meter Telemetry Systems for Monitoring Electricity Consumption?
PublikacjaThe estimation of electric power utilization, its baseload, and its heating, light, ventilation, and air-conditioning (HVAC) power component, which represents a very large portion of electricity usage in commercial facilities, are important for energy consumption controls and planning. Non-intrusive load monitoring (NILM) is the analytical method used to monitor the energy and disaggregate total electrical usage into appliance-related...
-
Electrochemical sensor for measurement of volatile organic compounds = Elektrochemiczny czujnik do oznaczania lotnych związków organicznych
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania benzaldehydu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako technikę detekcyjną woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym były ciecze jonowe: chlorek 1-heksylo,3- metyloimidazolinowy i bis(trifluorometylosulfonylo)imidek...
-
Application of hydroacoustic system of distance measurement for estimating the cod codends shape at the model research station in Insko
PublikacjaPraca przedstawia wyniki pomiarów kształtu worków dorszowych w stacji badań modelowych Politechniki Szczecińskiej w Ińsku. Badane worki dorszowe są workamispecjalnie zaprojektowanymi do połowów selektywnych. W celu precyzyjnego pomiaru parametrów geometrycznych worków został opracowany nowy hydroakustyczny system do precyzyjnych pomiarów odległości. Zapewnia on równoczesny pomiar maksymalnie 100 różnych wymiarów w zakresie od 0.1m...
-
Design of a Distributed System using Mobile Devices and Workflow Management for Measurement and Control of a Smart Home and Health
PublikacjaThe paper presents design of a distributed system for measurements and control of a smart home including temper- atures, light, fire danger, health problems of inhabitants such as increased body temperature, a person falling etc. This is done by integration of mobile devices and standards, distributed service based middleware BeesyCluster and a workflow management system. Mobile devices are used to measure the parameters and are...
-
Topological model of aptitude of the measurement circuits of main subassemblies of an internal combustion engine crankshaft-piston assembly
PublikacjaThe paper presents a topological model allowing to determine the probability of aptitude of the diagnosing system (SDG) individual measuring circuits and also to determine to what degree they influence the assessment of the technical condition of an arbitrary main subassembly of crankshaft-piston assemblies as a diagnosed system (SDN).
-
Laser reflectance interferometry system with a 405 nm laser diode for in-situ measurement of CVD diamond thickness
PublikacjaIn situ monitoring of the thickness of thin diamond films during technological processes is important because it allows better control of deposition time and deeper understanding of deposition kinetics. One of the widely used techniques is laser reflectance interferometry (LRI) which enables non-contact measurement during CVD deposition. The authors have built a novel LRI system with a 405 nm laser diode which achieves better...
-
Diagnostic testing of marine propulsion systems with internal combustion engines by means of vibration measurement and results analysis
PublikacjaIn this paper selected issues concerning vibration diagnosis of the mechanical system within marine propulsion units have been presented, carried out on the basis of experimental examinations of a real object in which an exceedance of the allowable vibration’s level had been observed. Used diagnosing system has been characterised. A procedure of longitudinal and transverse vibrations shaft lines of the mechanical system within...
-
HOW TO EFFECTIVELY ANALYSE THE IMPACT OF AIR QUALITY ON SOCIETY – REVIEW OF MODERN MEASUREMENT TECHNIQUES AND APPARATUS: PARTICULATES
Publikacja -
Do we know more about hypertension in Poland after the May Measurement Month 2017?—Europe
Publikacja -
Measurement Of The Dynamics Of The Sheave Block Of Shipyard Crane With 1000 T Lifting Capacity For Verification Of The Laboratory Stand
Publikacja