wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: ION-SELECTIVE ELECTRODES · MULTISENSOR SYSTEM · POTENCTIOMETRIC MEASUREMENTS · REFERENCE ELECTRODE
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublikacjaA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Polytypism and superconductivity in the NbS2 system
PublikacjaWe report on the phase formation and the superconducting properties in the NbS2 system. Specifically, we have performed a series of standardized solid-state syntheses in this system, which allow us to establish a comprehensive synthesis map for the formation of the two polytypes 2H-NbS2 and 3R-NbS2, respectively. We show that the identification of two polytypes by means of X-ray diffraction is not always unambiguous. Our physical...
-
Non-Destructive Testing of the Longest Span Soil-Steel Bridge in Europe—Field Measurements and FEM Calculations
PublikacjaThe article describes interdisciplinary and comprehensive non-destructive diagnostic tests of final bridge inspection and acceptance proposed for a soil-steel bridge made of corrugated sheets, being the European span length record holder (25.74 m). As an effect of an original concept a detailed and precise information about the structure short-term response was collected. Periodic diagnostics of bridge deformations was done one...
-
Quality Assurance and Quality Control in the Analytical Chemical Laboratory. A practical approach : Second edition
PublikacjaThe second edition defines the tools used in QA/QC, especially the application of statistical tools during analytical data treatment. Clearly written and logically organized, it takes a generic approach applicable to any field of analysis. The authors begin with the theory behind quality control systems, then detail validation parameter measurements, the use of statistical tests, counting the margin of error, uncertainty estimation,...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublikacjaThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Utility analysis and rating of energy storages in trolleybus power supply system
PublikacjaThe article discusses two energy storage applications in power supply system of public electrified transport. The first application aims at reducing the peak power of the traction substation. The second application increases effectiveness of using solar power plant to cover partial power demand of traction supply system. These two applications were discussed and analyzed based on trolleybus supply system in Gdynia, where most measurements...
-
Hybrid System for a Person Tracking in Harsh Indoor Environments
PublikacjaIn the article, the prototype of a system for a person tracking in a harsh indoor environment, especially when no other commercially available radiolocalization system can be used, was briefly described. The prototype realizes the data fusion, i.e. combines data from inertial and environmental sensors and radio distance measurements to estimate the position of a moving person. It is worth noting that the concept and practical realization...
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublikacjaThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
New matrix-free reference material for ethene in the form of optical fibres
PublikacjaReference materials are indispensable in the qualitycontrol and quality assurance of analytical measurements. Onenovel approach to the generation of standard gaseous mixturesof toxic, reactive, volatile, labile, and malodorous substancesinvolves thermal decomposition or rearrangement, under definedtemperature conditions, of compounds immobilized, bychemical bonding, on the surface of an appropriate carrier torelease specific amounts...
-
Modeling and Designing Acoustical Conditions of the Interior – Case Study
PublikacjaThe primary aim of this research study was to model acoustic conditions of the Courtyard of the Gdańsk University of Technology Main Building, and then to design a sound reinforcement system for this interior. First, results of measurements of the parameters of the acoustic field are presented. Then, the comparison between measured and predicted values using the ODEON program is shown. Collected data indicate a long reverberation...
-
Direct algorithm for optimizing robust MPC of drinking water distribution systems hydraulics
PublikacjaModel-based predictive control is an effective method for control the large scale systems [1]–[6], [8], [16], [17]. Method is based on on-line solution of the control task over the control horizon using current and past measurements, as well as the system model. Only a first element of calculated control sequence is applied to the plant. At the next sampling instant, based on new process output measurements, control procedure is...
-
Application potential of dummy molecularly imprinted polymers as solidphase extraction sorbents for determination of low-mass polybrominated diphenyl ethers in soil and sediment samples
PublikacjaDespite the introduction of restrictive regulations in the USA and the European Union, polybrominated diphenyl ethers (PBDEs) are still found in various types of environmental and biological samples at significant concentration levels. The presence of these persistent organic pollutants in the environment raises important issues because of their negative impact on immunological and neurological systems, and on the hormonal balances...
-
Hybrid‐mode single‐slope ADC with improved linearity and reduced conversion time for CMOS image sensors
PublikacjaIn the paper, a single‐slope analog‐to‐digital converter (ADC) for integrated CMOS image sensor applications with an improved technique of conversion has been proposed. The proposed hybrid‐mode ADC automatically uses one of the following conversion techniques: time based (i.e. PWM) or voltage based (i.e. single‐slope). During the ADC operation, the clock frequency and reference voltage are modified in order to reduce the conversion...
-
The XPS studies of the CB-PLA electrodes after different surface treatments (chemical, electrochemical, enzymatic)
Dane BadawczeThe dataset contains the Xray Photoelectron Spectroscopy results of the studies performed under different conditions of surface activation of the CB-PLA 3D printed electrodes. The activation was performed by hydrolysis in different solvents (DMF, 1M HCl, 1M NaOH), electrolysis in 1M NaOH, enzymatic treatment in polymerase or simultaneous electrolysis...
-
INVESTIGATION INTO INTERFEROMETRIC SONAR SYSTEM ACCURACY
PublikacjaThe results of the accuracy measurements of phase differencing bathymetric sonar (PDBS) system in shallow waters are presented in the article. The measurement results were compared with the theoretical calculations for sonar system accuracy and international standards for hydrographic surveys. The proposed formulas enable to assess a priori sonar system performance using system quality factor (SQF), which takes into account influence...
-
Trust-Based Model for the Assessment of the Uncertainty of Measurements in Hybrid IoT Networks
PublikacjaThe aim of this paper is to introduce a NUT model (NUT: network-uncertainty-trust) that aids the decrease of the uncertainty of measurements in autonomous hybrid Internet of Things sensor networks. The problem of uncertainty in such networks is a consequence of various operating conditions and varied quality of measurement nodes, making statistical approach less successful. This paper presents a model for decreasing the uncertainty...
-
Comparison of induction motor bearing diagnostic test results through vibration and stator current measurement
PublikacjaThe paper discusses results of tests performed by authors, related to the angine bearings diagnostic using vibration and stator current measurements. The paper contains the description of an automatic measurement system, developed for measurement of those harmonics and processing that to obtain bearing diagnostic information. System was tested on objects with intentionally made defects in bearings, results of this test was also...
-
Analiza i ocena smarności olejów w ujęciu energetycznym i działania układu tribologicznego = Analysis and evaluation of oil lubricity from the viewpoint of energy apects and of the tribological system action
PublikacjaBased on measurement results, an interpretation is presented of the tribological system boundary layer action in the form of a four-ball tester friction node. The evaluation was performed of the boundary layer action understood as transfer of energy Ep resulting from loading the tribological system in a determined time t with work Lp, which may lead to breaking the boundary layer. That energy and time are the values unequivocally...
-
Research on causes of corrosion in the municipal water supply system
PublikacjaThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
DMI measurements impact on a position estimation with lack of GNSS signals during Mobile Mapping
PublikacjaNowadays, Mobile Laser Scanning is common in use in addition to geodesy measurements. The data which are provided by the system characterizes with high precision and flexibility. To precise mapping, the accuracy of the data should be maintained. In Poland, according to the minister’s dispositions, the accuracy of the data should not exceeded 10 cm. With fully operated system it is easy to uphold, but there is a situation when a...
-
A Closed Bipolar Electrochemical Cell for the Interrogation of BDD Single Particles: Electrochemical Advanced Oxidation
PublikacjaA closed bipolar electrochemical cell containing two conductive boron-doped diamond (BDD) particles of size 250 – 350 m, produced by high-pressure high-temperature (HPHT) synthesis, has been used to demonstrate the applicability of single BDD particles for electrochemical oxidative degradation of the dye, methylene blue (MB). The cell is fabricated using stereolithography 3D printing and the BDD particles are located at either...
-
Combined effect of nitrogen-doped functional groups and porosity of porous carbons on electrochemical performance of supercapacitors
PublikacjaIn this work, nitrogen-doped porous carbons obtained from chitosan, gelatine, and green algae were investigated in their role as supercapacitor electrodes. The effects of three factors on electrochemical performance have been studied— of the specific surface area, functional groups, and a porous structure. Varying nitrogen contents (from 5.46 to 10.08 wt.%) and specific surface areas (from 532 to 1095 m2g−1) were obtained by modifying...
-
Locally sculptured modification of the electrochemical response of conductive poly(lactic acid) 3D prints by femtosecond laser processing
PublikacjaThis manuscript presents an approach to sculpture high electrochemical activity of the 3D printed electrodes with poly(lactic acid) (PLA) matrix and carbon black (CB) filler by femtosecond laser (FSL) ablation. CB-PLA utility for electrochemical applications depends on a surface modification aiming to remove the PLA and uncover the conductive CB. We have discussed how laser pulse energy is critical for such an activation process....
-
Preparation and structure of nanocrystalline sol-gel derived Cu doped LiTi2O4 powders
PublikacjaAmong the spinel oxides materials, lithium titanate (Li1+xTi2-xO4 where 0 ≤ x ≤ 0.33) could be very interested from pratical applications point of view. Lithium titanate is a II type spinel oxide superconductor with relatively high (~13 K for x = 0) superconducting transition temperature Tc. Above Tc lithium titanate shows metallic behaviour and can be used e.g. as electrodes for rechargeable lithium-ion batteries. Since the discovery...
-
PARAMETERS OF THE ELECTROPHORETIC DEPOSITION PROCESS AND ITS INFLUENCE ON THE MORPHOLOGY OF HYDROXYAPATITE COATINGS. REVIEW
PublikacjaMetallic materials intended for bone implants should exhibit not only appropriate mechanical properties, but also high biocompatibility. The surface treatment modifications, for example acidic treatment, laser treatment, ion implantation and deposition of highly biocompatible coatings, are practiced. One of the most popular methods of surface modification is to deposit hydroxyapatite (HAp) coatings. HAp naturally occurs in human...
-
A review of design approaches for the implementation of low-frequency noise measurement systems
PublikacjaElectronic noise has its roots in the fundamental physical interactions between matter and charged particles, carrying information about the phenomena that occur at the microscopic level. Therefore, Low-Frequency Noise Measurements (LFNM) are a well-established technique for the characterization of electron devices and materials and, compared to other techniques, they offer the advantage of being non-destructive and of providing...
-
The conducted immunity test of an AC adaptor in accordance with EMC standards
Dane BadawczeThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the ac adaptor PHILIPS DC power supply SBC 6654. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz...
-
St. Adalberd church 3D point model
Dane BadawczeResearch data show the church of St. Adalbert in Gdansk, Poland. Two layers are presented in the .zip file: one represents the laser scanning result, the second represents the point cloud from 36 photogrammetry images from the UAV system. The aligned point clouds formed the basis to create the high-resolution 3D model. Reference data are laser scanning...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Dane BadawczeThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Linear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Accuracy and Availability of EGNOS - Results of Observations
PublikacjaAccording to SBAS concept the user should receive timely the correct information about the system integrity and corrections to the pseudoranges measurements, which leads to better accuracyof coordinates. In theory the whole system is permanently monitored by RIMS stations, so it is impossible to deliver the faulty information to the user. The quality of the system is guaranteed inside the border of the system coverage however in...
-
Practical Approach to Large-Scale Electronic Structure Calculations in Electrolyte Solutions via Continuum-Embedded Linear-Scaling Density Functional Theory
PublikacjaWe present the implementation of a hybrid continuum-atomistic model for including the effects of a surrounding electrolyte in large-scale density functional theory (DFT) calculations within the Order-N Electronic Total Energy Package (ONETEP) linear-scaling DFT code, which allows the simulation of large complex systems such as electrochemical interfaces. The model represents the electrolyte ions as a scalar field and the solvent...
-
Preparation and Characterization of Nanomaterial Consisting of Silica Aerogel & Carbon Tested as an Electrode in Non-Aqueous Media Containing Lithium Salt.
PublikacjaSilica aerogel (SiO2ag) was combined with carbonaceous material in the pyrolysis process of hydrocarbons. The obtained nanocomposite SiO2ag/C was amorphous, partially preserving the porous structure of SiO2ag. The specific surface area changes from 445.6 m2/g for pure SiO2ag to 205.52 m2/g SiO2ag/C. The 29Si MAS-NMR shows a three-dimensional matrix with silicon atoms connected to other silicon atoms by four...
-
The bismuth vanadate thin layers modified by cobalt hexacyanocobaltate as visible-light active photoanodes for photoelectrochemical water oxidation
PublikacjaBismuth vanadate thin films deposited using the pulsed laser deposition technique were modified using cobalt hexacyanocobaltate (Cohcc). The 2-step method of Cohcc nanocubes preparation was applied: i) metallic cobalt deposition and ii) cobalt electrooxidation in Co(CN)63− containing electrolyte. The presence of CN stretching vibrations was confirmed by Raman spectroscopy. The energy band gap was equal to 2.5 eV and was estimated...
-
Enhancing electrochemical properties of an ITO-coated lossy-mode resonance optical fiber sensor by electrodeposition of PEDOT:PSS
PublikacjaA sensor working in multiple domains may offer enhanced information about the properties of an investigated analyte, including those containing biological species. It has already been shown that a dual-domain sensing capability, i.e., in optical and electrochemical domains, can be offered by lossy-mode resonance (LMR) sensors based on indium-tin-oxide (ITO) thin film. The spectral response of the LMR sensors depends on the refractive...
-
The influence of the welding environment on the properties of Tekken joints made from S355J2C+N steel
PublikacjaThere are three main methods of underwater welding: dry, wet and intermediate between them, by using the local dry chamber. Due to low costs, the most common method is the wet welding with the use of covered electrodes. Water as a welding environment carries out a lot of problems. The first is limited visibility and instability of the welding arc. The biggest problem during underwater welding is high susceptibility to cold cracking,...
-
Mixed, quantum-classical description of electron density transfer in the collision process
PublikacjaIn this work, we investigate an ion-atom model describing the time-dependent evolution of electron density during the collision. For a S3+- H system, numerical simulations are based on classical trajectory calculations, and the electron density behaviour is described with the time-dependent Schrödinger equation. We apply the finite difference method to obtain quantitative insights into the charge transfer dynamics, providing detailed...
-
Two kinds of oxygen vacancies in lithium titaniate doped with copper as detected by EPR
PublikacjaLithium titanate (Li1+xTi2-xO4) doped with Cu2+ ions was synthesized by sol-gel processing method. The structure and morphology are characterized by X-ray Diffraction (XRD), X-ray Photoemission Spectroscopy (XPS), Scanning Electron Microscopy (SEM) and Electron Paramagnetic Resonance (EPR). Spin Hamiltonian parameters describing Zeeman and hyperfine interaction for 63Cu2+ ions were obtained from EPR spectra simulations. The spectra...
-
Focused ion beam-based microfabrication of boron-doped diamond single-crystal tip cantilevers for electrical and mechanical scanning probe microscopy
PublikacjaIn this paper, the fabrication process and electromechanical properties of novel atomic force microscopy probes utilising single-crystal boron-doped diamond are presented. The developed probes integrate scanning tips made of chemical vapour deposition-grown, freestanding diamond foil. The fabrication procedure was performed using nanomanipulation techniques combined with scanning electron microscopy and focused ion beam technologies....
-
Compensation of magnetic disturbances caused by sensors in a differential magnetometric system
PublikacjaStudy of low magnetic fields necessitates the use of precision magnetometers working in a differential system. Minimization of this error is a substantial issue in the case of magnetometers working in a differential system on a mobile platform. The compensation method of heading error consists in taking measurements of changes in magnetic induction with the use of the tested magnetometer for various locations of the sensor in relation...
-
Nonlinear Fuzzy Control System for Dissolved Oxygen with Aeration System in Sequencing Batch Reactor
PublikacjaBiological processes at a wastewater treatment plant are complex, multivariable, time varying and nonlinear. Moreover, interactions between the components are very strong. Control of dissolved oxygen is one of most important task at the plant. The level of dissolved oxygen in aerobic tanks has significant influence on behaviour and activity of microorganisms at the plant. Air for aerated tanks is supplied by the aeration system...
-
Precise Bathymetry as a Step Towards Producing Bathymetric Electronic Navigational Charts for Comparative (Terrain Reference) Navigation
PublikacjaBathymetric Electronic Navigational Charts (bENCs) contain only bathymetry data and can be used in applications such as underwater positioning, dredging and piloting. According to International Hydrographic Organization (IHO) standard S-57, Electronic Navigational Charts (ENCs) contain depth information with pure density of depth contours. Typical depth contours encoded by Hydrographic Offices are limited to 2, 5, 10 and 20 m....
-
Application of Analytic Signal and Smooth Interpolation in Pulse Width Modulation for Conventional Matrix Converters
PublikacjaThe paper proposes an alternative and novel approach to the PWM duty cycles computation for Conventional Matrix Converters (CMC) fed by balanced, unbalanced or non–sinusoidal AC voltage sources. The presented solution simplifies the prototyping of direct modulation algorithms. PWM duty cycles are calculated faster by the smooth interpolation technique, using only vector coordinates, without trigonometric functions and angles. Both...
-
Large‐Scale Traveling Ionospheric Disturbances Over the European Sector During the Geomagnetic Storm on March 23–24, 2023: Energy Deposition in the Source Regions and the Propagation Characteristics
PublikacjaMultiple Large-Scale Traveling Ionospheric Disturbances (LSTIDs) are observed in the European sector in both day-time and night-time during the magnetic storm on March 23–24, 2023. The Total Electron Content (TEC) observation from a network of GNSS receivers shows the propagation of LSTIDs with amplitudes between around 0.5 and 1 TECU originating from auroral and polar cusp regions down to southern Europe (35°N) with velocities...
-
Properties of Oxygen Vacancy and Hydrogen Interstitial Defects in Strontium Titanate: DFT + Ud,p Calculations
PublikacjaThis work presents extensive theoretical studies focused on the mixed ion-electron transport in cubic strontium titanate (STO). A new approach to the description of this difficult system was developed within the framework of linear-scaling Kohn–Sham density functional theory, as realized in the ONETEP program. The description we present is free of any empirical parameters and relies on the Hubbard U and Hund’s J corrections applied...
-
Evaluation of possibilities in identification and susceptibility testing for Candida glabrata clinical isolates with the Integral System Yeast Plus (ISYP)
PublikacjaThe aim of this study was to evaluate possibilities of correct identification and susceptibility testing of C. glabrata clinical isolates with Integral System Yeast Plus (ISYP). For species identification, as the reference method, API Candida test and species-specific PCR reactions were used. The potential of antifungal susceptibility testing by the ISYP test was compared with the Sensititre Yeast One. Whilst the reference methods...
-
Design and implementation of the driver system for Hamamatsu C12880MA microspectrometer
PublikacjaRecent miniaturization developments in devices for spectroscopy have reduced greatly their costs and increased their availability for a wide range of users and applications. This paper presents the design and implementation of a driver system for a Hamamatsu C12880MA microspectrometer. The system implementation was carried out and compared using two independent microcontroller modules: Arduino Uno and STM32F411RE Nucleo. We assessed...
-
Synthesis of N-doped TiO2 nanoparticles with enhanced photocatalytic activity for 2,4-dichlorophenol degradation and H2 production
PublikacjaNitrogen-doped titanium dioxide (N-TiO2) nanoparticles were prepared using a modified sol-gel method. The as-prepared nanoparticles were characterized by state-of-the-art techniques for their optical, structural and morphological properties. The crystallite size, surface area and bandgap energy of reference TiO2 and N-TiO2 nanoparticles were found to be 16.1 and 10.9 nm, 83.6 and 131.8 m2 g−1 and 3.23 and 2.89 eV, respectively....
-
On Memory-Based Precise Calibration of Cost-Efficient NO2 Sensor Using Artificial Intelligence and Global Response Correction
PublikacjaNitrogen dioxide (NO2) is a prevalent air pollutant, particularly abundant in densely populated urban regions. Given its harmful impact on health and the environment, precise real-time monitoring of NO2 concentration is crucial, particularly for devising and executing risk mitigation strategies. However, achieving precise measurements of NO2 is challenging due to the need for expensive and cumbersome equipment. This has spurred...
-
Supervisory Control System for Adaptive Phase and Work Cycle Management of Sequencing Wastewater Treatment Plant
PublikacjaThe paper presents the design of the integrated control system applied to Sequencing Batch Reactor (SBR) in a biological Wastewater Treatment Plant (WWTP) in Swarzewo, which operates under activated sludge technology. Based on the real data records, ASM2d biological processes model and aeration system model, hierarchical control system for dissolved oxygen tracking and cycle management is designed. Internal Model Controller (IMC)...