Filtry
wszystkich: 748
-
Katalog
Wyniki wyszukiwania dla: PASSIVE HIP MOMENT
-
Series Passive Compensation of Common Mode Voltage in Multilevel Inverter Drives
PublikacjaThis paper presents an approach to the problem of a magnetic saturation of CM chokes that accompanies the method of passive compensation of a common mode (CM) voltage in an inverter drive system. Measurements have been provided in a drive system including multilevel inverters and the filter having sinusoidal output voltages and zero CM voltage. The theoretical analysis and experimental results show that the problem with magnetic...
-
Application of passive acoustic radar to automatic localization, tracking and classification of sound sources
PublikacjaA concept, practical realization and applications of the passive acoustic radar to automatic localization, tracking and classification of sound sources were presented in the paper. The device consists of a new kind of multichannel miniature sound intensity sensors and a group of digital signal processing algorithms. Contrary to active radars, it does not emit the scanning beam but after receiving surrounding sounds it provides...
-
Application of galvanodynamic impedance spectroscopy for studying passive film cracking under mechanical strain
PublikacjaThe paper reports the results of simultaneous mechanical and electrochemical investigations on austenitic (18/8) stainless steel in a 2 % solution of sulphuric acid. The measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Electrochemical analysis of mechanical passive layer cracking and repassivation conditions during a tensile test was carried out. Application of this methodology allowed...
-
Journal of Active and Passive Electronic Devices
Czasopisma -
Automatic localization and continous tracking of mobile sound source using passive acoustic radar
PublikacjaA concept, practical realization and applications of the passive acoustic radar for localization and continuous tracking of fixed and mobile sound sources such as: cars, trucks, aircrafts and sources of shooting, explosions were presented in the paper. The device consists of the new kind of multi-channel miniature three dimensional sound intensity sensors invented by the Microflown company and a group of digital signal processing...
-
Experimental Designs of Mass Customized Passive Single-family Houses - Prospects and Limitations
PublikacjaAbstract The article deals with case studies of selected architectural designs of the past fifteen years the authors of which intended to rethink both the typology and the means of constructing single family houses. The analysis covers contemporary design issues such as variation, curvilinearity, customization, digital manufacturing and ecological concerns. The purpose behind the research was to establish in what way new design...
-
Friction forces for human hip joint at a naturally permeable cartilage
PublikacjaNiniejsza praca omawia różne rodzaje sił tarcia występujących w szczelinach stawów człowierka. W artykule dokonano analizy kilku ważnych czynników wpływających na wartości sił tarcia występujących w stawach człowieka. Rozważa się siły tarcia wywołane klasycznym hydrodynamicznym smarowaniem, wzmożonym hydrodynamicznym smarowaniem, wyciskaniem a także przesączaniem cieczy synowialnej do i z porowatej warstwy chrząstki stawowej.
-
Dual-Energy Computed Tomography in Loosening of Revision Hip Prosthesis
Publikacja -
Periodic and impulsive lubrication of hip joint with stochastic rough surface.
PublikacjaNiniejsza praca przedstawia porównanie wartości nośności uzyskanych numerycznie dla niestacjonarnego smarowania impulsywnego oraz niestacjonarnego smarowania periodycznego sferycznego stawu biodrowego człowieka. W obu przypadkach przyjęto, że smarująca ciecz synowialna ma własności lepkosprężyste a występy chropowatych powierzchni chrząstki stawowej zmieniają się losowo. Charakterystyki zmiennych w czasie rozkładów wartości ciśnienia...
-
Impulsive lubrication of hip joint for hypo-elastic cartilage model
PublikacjaPraca rozwiązuje problem smarowania stawu biodrowego człowieka w warunkach niestacjonarnych z uwzględnieniem hypo-sprężystych (pod-sprężystych) właściwości odkształcalnej szkieletu chrząstki stawowej. Prezentowane są rozkłady wartości ciśnienia hydrodynamicznego oraz zmienne w czasie rozkłady wartości sił nośnych.
-
The home-made in situ passive flux sampler for the measurement of monoterpene emission flux: preliminary studies
PublikacjaThe paper presents the construction and metrological characteristics of the home-made in situ passive flux sampler, an analytical tool representing small-scale emission chambers working in situ and passively sampling analytes from the gaseous phase. The sorption element was a cylindrical container made of stainless steel net, packed with a carbon sorbent bed-graphitized charcoal, Carbograph 4 (35/50mesh). The recommended working/exposure...
-
Application of the chromatographic retention index system for the estimation of the calibration constants of permeation passive samplers with polydimethylsiloxane membranes
PublikacjaThe paper presents the results of research on the calibration of permeation passive samplers equipped with polydimethylsiloxane (PDMS) membranes using the physico-chemical properties of the analytes. Strong correlations were found between the calibration constants of the samplers and the linear temperature-programmed retention indices of the analytes determined on columns coated with pure PDMS (r2 = 0.914). These correlations...
-
THE SYNCHROSQUEEZING METHOD IN BEARING ESTIMATION OF STATIONARY SIGNALS FOR PASSIVE SONAR WITH TOWED ARRAY
PublikacjaIn this paper, a novel method of bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of bearing estimation based on the spatial spectrum [1] is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. [2]. Using this method leads to a precise bearing estimation. The proposed method requires a relatively small amount of computation,...
-
Expedited Optimization of Passive Microwave Devices Using Gradient Search and Principal Directions
PublikacjaOver the recent years, utilization of numerical optimization techniques has become ubiquitous in the design of high-frequency systems, including microwave passive components. The primary reason is that the circuits become increasingly complex to meet ever growing performance demands concerning their electrical performance, additional functionalities, as well as miniaturization. Nonetheless, as reliable evaluation of microwave device...
-
Pounding mitigation of a short-span cable-stayed bridge using a new hybrid passive control system
PublikacjaThis paper investigates the effectiveness of a new hybrid passive control system on the seismic response of an existing steel cable-stayed bridge considering the pounding effect. The proposed hybrid passive control system comprises a seismic isolator and a metallic damper. The bridge is located in a high seismic zone and has suffered several damages including the earthquake-induced pounding damage during the 1988 earthquake....
-
The external walls of a passive building: A classification anddescription of their thermal and optical properties
PublikacjaThis paper attempts a new classification of insulating materials from the perspective of their utility in thepro-ecological passive construction industry. The main criterion is the conductivity of thermal and solarenergy. Based on their ability to conduct or block fluxes of thermal and solar energy, six types of insulatingwalls are proposed. On the basis of this criterion there are traditional dividing walls (typical walls, wallinsulating...
-
Passive sonar with cylindrical array
PublikacjaArtykuł prezentuje sposób wykorzystania sonaru aktywnego z anteną cylindryczną do nasłuchu pasywnego podwodnych źródeł dźwięku. Wykazano, że wykrycie źródła dźwięku i określenie jego namiaru może być zrealizowane bez zmian konstrukcji odbiornika. Wymagana jest jedynie zmiana algorytmów przetwarzania sygnałów w beamformerze. Wykazano również, że w celu zwiększenia dokładności namiaru można zastosować wysokorozdzielcze metody estymacji...
-
Imaging forms in passive sonars
PublikacjaReferat jest kontynuacją tematyki organizacji zobrazowań we współczesnych systemach hydrolokacyjnych przedstawionej w referacie zaproszonym na ubiegłorocznym OSA dla systemów aktywnych. Tym razem dotyczy organizacji zobrazowań w systemach pasywnych. W praktyce, prócz prostych systemów nasłuchu i rejestracji dźwięków podwodnych, używanych przez badaczy fauny wodnej czy oceanografów, systemy pasywne są wykorzystywane w marynarkach...
-
Performance of Passive and Active Balancing Systems of Lithium Batteries in Onerous Mine Environment
PublikacjaTo use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Issues relating to the efficient Application of passive solar protection in multi-family residential buildings
PublikacjaThe following article is intended to discuss the issues concerning the introduction of passive measures aimed at improving solar protection in multi-family buildings. A system of classifying these methods into two groups of solutions (architectural and material-building) was applied. The first group includes issues concerning facade design, the spatial features of which (such as loggias, balconies and other overhangs) can be treated...
-
Hip joint mobility in relation to measurement position, gender and limb dominance
Publikacja -
Non-Newtonian lubrication of human hip joint for unsteady impulsive motion
PublikacjaTematem niniejszej pracy są parametry smarowania lepkosprężystą cieczą synowialną stawu biodrowego człowieka w czasie kilku, kilkunastu a nawet kilkudziesięciu mikrosekund po doznanym urazie. W niniejszej pracy rozpatruje się urazy wywołujące zmniejszenie lub zwiększenie wysokości i zmiany kształtu szczeliny stawu, które to zmiany po pewnym określonym czasie po doznanym urazie mogą zanikać. W konsekwencji takich urazów i to w...
-
Vojta method in the treatment of developmental hip dysplasia – a case report
Publikacja -
Vojta method in the treatment of developmental hip dysplasia – a case report
Publikacja -
Measurements of surface roughness of heads of human hip joints in lubrication aspects
PublikacjaW niniejszej pracy przedstawiono wyniki pomiarów chropowatości chrząstki stawowej na powierzchniach głów kostnych stawu biodrowego człowieka. Pomiarów dokonano przy pomocy czujników mechanicznych i laserowych. Praca zawiera wyniki analizy statystycznej.
-
Bearing estimation using double frequency reassignment for a linear passive array
PublikacjaThe paper demonstrates the use of frequency reassignment for bearing estimation. For this task, signals derived from a linear equispaced passive array are used. The presented method makes use of Fourier transformation based spatial spectrum estimation. It is further developed through the application of two-dimensional reassignment, which leads to obtaining highly concentrated energy distributions in the joint frequency-angle domain...
-
The Influence of Microstructure on the Passive Layer Chemistry and Corrosion Resistance for Some Titanium-Based Alloys
PublikacjaThe effect of microstructure and chemistry on the kinetics of passive layer growth and passivity breakdown of some Ti-based alloys, namely Ti-6Al-4V, Ti-6Al-7Nb and TC21 alloys, was studied. The rate of pitting corrosion was evaluated using cyclic polarization measurements. Chronoamperometry was applied to assess the passive layer growth kinetics and breakdown. Microstructure influence on the uniform corrosion rate of these alloys...
-
Machine learning-based prediction of seismic limit-state capacity of steel moment-resisting frames considering soil-structure interaction
PublikacjaRegarding the unpredictable and complex nature of seismic excitations, there is a need for vulnerability assessment of newly constructed or existing structures. Predicting the seismic limit-state capacity of steel Moment-Resisting Frames (MRFs) can help designers to have a preliminary estimation and improve their views about the seismic performance of the designed structure. This study improved data-driven decision techniques in...
-
A comparative study of the performance of passive samplers
PublikacjaPodstawowym celem podjętych badań było porównanie pracy dozymetrów pasywnych wykorzystywanych na etapie izolacji i wzbogacania lotnych związków organicznych z powietrza atmosferycznego na terenie aglomeracji Trójmiejskiej. Jako próbniki do pobierania próbek analitów zastosowano komercyjne dozymetry pasywne typu dyfuzyjnego (Radiello i Orsa 5) oraz dozymetry typu permeacyjnego własnej konstrukcji wyposażone w półprzepuszczalną membranę...
-
Advances in passive sampling in environmental studies
PublikacjaDozymetria pasywna stanowi użyteczne narzędzie wykorzystywane w monitoringu środowiskowym. W pracy zostały zawarte nowe rozwiązania i udoskonalenia istniejących próbników pasywnych oraz praktyczne ich wykorzystanie w monitoringu środowiskowym.
-
Electrochemical analysis of aluminium passive layer
PublikacjaZbadano proces pękania warstwy pasywnej na aluminium dla liniowo narastających naprężeń rozciągających oraz różnych warunków elektrochemicznych. Badania prowadzono w 0.1M NaCl metodą dynamicznej elektrochemicznej spektroskopii impedancyjnej przy różnych poziomach polaryzacji anodowej. Określono progową wartość naprężeń, przy której następowało zniszczenie warstwy pasywnej wskutek działania sił rozciągających.
-
Small-scale passive emission chamber for screening studies on monoterpene emission flux from the surface of wood-based indoor elements
PublikacjaAnalysis of literature data published in the last fewyears leads to the conclusion that in the process of assessment of emission flux of organic compounds emitted from different types of equipment and finishing materials, new types of devices, among which small-scale passive emission chambers for the performance of in-situ research are designed and applied on a larger scale. These devices can be successfully used for the assessment...
-
Experimental measurements of artificial hip joint surfaces and applications for the preassure and capacity distributions
PublikacjaZe względu na wzrastającą potrzebę wszczepiania człowiekowi endoprotez stawu biodrowego, niniejsza praca przedstawia badania geometrycznej struktury ich powierzchni, które mają znaczący wpływ na proces smarowania, eksploatacji oraz funkcjonowanie narządów ruchu.
-
Preoperative Ultrasonographic Assessment of the Anterior Pelvic Plane for Personalized Total Hip Replacement
Publikacja -
Tribological and nanoscale research on model friction couples intended for hip joint prostheses
Publikacja -
Comparisson between impulsive and periodic non-newtonian lubrication of human hip joint
PublikacjaOpis smarowania powierzchni sferycznych stawu biodrowego człowieka przedstawiono w aspektach hydromechaniki, przy pomocy równań zachowania pędu i ciągłości strugi dla osiowo niesymetrycznego przepływu cieczy lepkosprężystej z wykorzystaniem związków konstytutywnych Rivlina Ericksena we współrzędnych sferycznych.
-
A proposition of the computational model for the dynamic analysis of stress and strain distribution in the hip joint
PublikacjaCelem pracy jest sformułowanie zadania modelowania dynamiki odkształceń i rozkładu naprężeń stawu biodrowego, a w szczególności kości udowej, pod wpływem sił mięśniowych oraz zadanych sił zewnętrznych. Rozwiązanie tego zadania pozwoli wyjaśnić niektóre zjawiska np. jakie ruchy kości udowej oraz jakie materiały użyte do jej alloplastyki są przyczyną urazów i poważnych uszkodzeń. Omówiono problemy związane z zastosowaniem metody...
-
Machine learning-based prediction of residual drift and seismic risk assessment of steel moment-resisting frames considering soil-structure interaction
PublikacjaNowadays, due to improvements in seismic codes and computational devices, retrofitting buildings is an important topic, in which, permanent deformation of buildings, known as Residual Interstory Drift Ratio (RIDR), plays a crucial role. To provide an accurate yet reliable prediction model, 32 improved Machine Learning (ML) algorithms were considered using the Python software to investigate the best method for estimating Maximum...
-
Moment resistance of I-section end-plate roof girder splices; a case study
PublikacjaThis article deals with the problem of determining the resistance of end-plate connections. A nonlinear FEM model of the joint was constructed in order to predict its carrying capacity. A standard code procedure was done as well. The analyses have been done to assess atypical end-plate joints designed and constructed as a part of roof structures.
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublikacjaTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
Dynamic Electrochemical Impedance Spectroscopy in Galvanostatic Mode as a Tool for Passive Layer State Monitoring in a Chloride Solution Under a Mechanical Load
PublikacjaMechanical stress is one of the factors influencing the initiation of pitting corrosion and deterioration of the protective properties of the passive layer on stainless steel. The tests carried out on AISI 304L stainless steel showed that, in the 3.5% NaCl environment for samples loaded in the elastic and plastic range, no pitting corrosion initiation was observed. Only mechanical damage of the passive layer occurred. Galvanodynamic...
-
Optimizing of target detection and tracking processes realized on consoles of passive sonar with linear towed antenna
PublikacjaThe long-range passive towed sonar was first modernised a few years ago. Building on operator experience over that period, a concept was developed of optimising the tasks performed by sonar operators, and improving forms of imaging to inform about object detection and support object tracking. The concept was implemented and successfully tested during ships’ manoeuvres. The optimisation of operator tasks was designed to keep listening...
-
Comparative electrochemical analysis of the passive layer cracking process on aluminum alloys performed by means of DC and AC techniques
PublikacjaZbadano proces pękania warstwy pasywnej na stopach aluminium AA1050, AA5052, AA5056, oraz AA7005 w warunkach zmiennych naprężeń rozciągających i polaryzacji anodowej z wykorzystaniem techniki stałoprądowej, DEIS oraz emisji akustycznej (AE), jako metody porównawczej. Przeprowadzone badania pokazały przewagę techniki DEIS oraz emisji akustycznej nad klasyczną techniką stałoprądową. Wyznaczono dokładny moment pęknięcia warstwy pasywnej...
-
Application of passive sampling technique for monitoring of BTEX concentration in urban air: Field comparison of different types of passive samplers
PublikacjaW efekcie przeprowadzonych badań potwierdzono przydatności techniki dozymetrii pasywnej wykorzystywanej na etapie izolacji i wzbogacania analitów do uzyskania informacji o poziomie stężeń zanieczyszczeń z grupy BTEX w powietrzu atmosferycznym na terenie aglomeracji Trójmiejskiej. Dodatkowo, porównano wyniki oznaczeń uzyskanych z wykorzystaniem dwóch typów dozymetrów pasywnych.
-
A new approach in the calibration of passive samplersA new approach on the calibration of passive dosimeters for studies of indoor air (....--------ROZBIEŻNOŚĆ TYTUŁÓW-------------------------------------
PublikacjaPrzedstawiono problematykę kalibracji próbników pasywnych wykorzystywanych w Katedrze Chemii Analitycznej Wydz. Chemicznego PG do monitoringu jakości powietrza wewnętrznego. Proponowane podejście pozwala na oszacowanie wartości stałych kalibracyjnych, a tym samym oznaczenia stężeń związków od heksanu do dodekanu. Tak więc permeacyjne dozymetry pasywne mogą być wykorzystane w analogicznym zakresie jak próbniki aktywne.
-
The Dilemmas of Choosing a Suitable Technology for Low Energy and Passive Houses in the Context of their Overheating Issues
PublikacjaIn compliance with European Union directives, numerous countries are introducing increasingly stricter legal limits on the estimated energy consumption of newly designed residential buildings. However, the fact, that regulations and designers' efforts are focused on decreasing energy consumption (and consequently carbon dioxide emissions) only at the post-occupancy stage, may lead to a significant increase in the carbon footprint...
-
Visualisation forms in passive sonar with towed array
PublikacjaArtykuł dotyczy organizacji zobrazowań na monitorach modernizowanego w KSEM sonaru pasywnego z długą, holowaną za rufą okrętu, anteną akustyczną. We wprowadzeniu opisano strukturę takiego sonaru oraz sposób pozyskiwania i charakter odbieranych sygnałów jako podstawę organizowania zobrazowań efektów nasłuchu. Dalej opisano inne czynniki wpływające na organizację obrazów na monitorach sonaru tzn. zadania operatorów, organizację i...
-
Passive samplers in indoor air quality control
PublikacjaPrzedstawiono wyniki badań jakości powietrza wewnętrznego w 12 wybranych mieszkaniach usytuowanych na terenie aglomeracji Trójmiejskiej z wykorzystaniem techniki pasywnej (dozymetria pasywna typu permeacyjnego) oraz techniki dynamicznej (rurki sorpcyjne wypełnione sorbentem Tenax TA). Wykorzystując nowe podejście do sposobu kalibracji dokonano monitoringu zarówno poszczególnych lotnych związków organicznych jak i sumarycznej zawartości...
-
Passive sampling techniques for monitoring pollutants in water
PublikacjaPraca przeglądowa poświęcona technice dozymetrii pasywnej. Omówiono charakterystykę wybranych próbników pasywnych wykorzystywanych w analityce zanieczyszczeń wody. Ponadto przedstawiono zalety i wady technik pasywnych oraz opisano obszar praktycznego zastosowania próbnikow pasywnych.