Wyniki wyszukiwania dla: calibration
-
A Method of Fast and Simultaneous Calibration of Many Mobile FMCW Radars Operating in a Network Anti-Drone System
PublikacjaA market for small drones is developing very fast. They are used for leisure activities and exploited in commercial applications. However, there is a growing concern for accidental or even criminal misuses of these platforms. Dangerous incidents with drones are appearing more often, and have caused many institutions to start thinking about anti-drone solutions. There are many cases when building stationary systems seems to be aimless...
-
Cost-Efficient Measurement Platform and Machine-Learning-Based Sensor Calibration for Precise NO2 Pollution Monitoring
PublikacjaAir quality significantly impacts human health, the environment, and the economy. Precise real-time monitoring of air pollution is crucial for managing associated risks and developing appropriate short- and long-term measures. Nitrogen dioxide (NO2) stands as a common pollutant, with elevated levels posing risks to the human respiratory tract, exacerbating respiratory infections and asthma, and potentially leading to chronic lung...
-
Efficient Calibration of Cost-Efficient Particulate Matter Sensors Using Machine Learning and Time-Series Alignment
PublikacjaAtmospheric particulate matter (PM) poses a significant threat to human health, infiltrating the lungs and brain and leading to severe issues such as heart and lung diseases, cancer, and premature death. The main sources of PM pollution are vehicular and industrial emissions, construction and agricultural activities, and natural phenomena such as wildfires. Research underscores the absence of a safe threshold for particulate exposure,...
-
Filter-Hilbert Method for Automatic Correction of Non-Anechoic Antenna Measurements with Embedded Self-Calibration Mechanism
PublikacjaOne of the most important steps in the process of antenna development involves measurements of its prototype. Far-field performance of radiators is normally characterized in strictly controlled environments such as anechoic chambers which can ensure certification-grade accuracy. Unfortunately, they are also characterized by high construction costs which might not be justified for low-budget research and/or teaching-related activities....
-
Utilization of thermal decomposition of immobilized compounds for the generation of gaseous standard mixtures used in the calibration of gas analysers
Publikacja -
Physical modeling in sands in a wide range of stress level: Application to the calibration of CPTU i DMT tests.
PublikacjaPraca dotyczy badań modelowych w gruntach niespoistych ze szczególnym uwzględnieniem wpływu wysokiego poziomu naprężenia na zachowanie się podłoża gruntowego. Praca składa się z siedmiu rozdziałów. W pierwszym z nich opisano zachowanie się piasku w szerokim zakresie naprężeń z uwzględnieniem ściśliwości, kruszenia się ziaren, nieliniowości obwiedni zniszczenia oraz nieliniowości modułu odkształcenia związanych z poziomem naprężenia...
-
Field Calibration of Low-Cost Particulate Matter Sensors Using Artificial Neural Networks and Affine Response Correction
PublikacjaDue to detrimental effects of atmospheric particulate matter (PM), its accurate monitoring is of paramount importance, especially in densely populated urban areas. However, precise measurement of PM levels requires expensive and sophisticated equipment. Although low-cost alternatives are gaining popularity, their reliability is questionable, attributed to sensitivity to environmental conditions, inherent instability, and manufacturing...
-
On Memory-Based Precise Calibration of Cost-Efficient NO2 Sensor Using Artificial Intelligence and Global Response Correction
PublikacjaNitrogen dioxide (NO2) is a prevalent air pollutant, particularly abundant in densely populated urban regions. Given its harmful impact on health and the environment, precise real-time monitoring of NO2 concentration is crucial, particularly for devising and executing risk mitigation strategies. However, achieving precise measurements of NO2 is challenging due to the need for expensive and cumbersome equipment. This has spurred...
-
Fast Calibration-Free Single-Anchor Indoor Localization Based on Limited Number of ESPAR Antenna Radiation Patterns
Publikacja— In this article, we investigate how the calibrationfree single-anchor indoor localization algorithm developed for base stations equipped with electronically steerable parasitic array radiator (ESPAR) antennas can further be improved. By reducing the total number of ESPAR antenna radiation patterns used in localization process, one can significantly reduce the time needed for an object localization. Performed localization measurements...
-
Accurate PPCC-Based DoA Estimation Using Multiple Calibration Planes for WSN Nodes Equipped with ESPAR Antennas
PublikacjaIn this paper, we have introduced a new direction-of-arrival (DoA) estimation method, which relies on received signal strength (RSS) values measured at the output port of electronically steerable parasitic array radiator (ESPAR) antenna and uses the power pattern cross-correlation (PPCC) estimator. In the method, we have successfully incorporated measurements of ESPAR antenna's radiation patterns performed at multiple calibration...
-
Kalibracja przyrządów analitycznych, wykorzystanie gazowych mieszanin wzorcowych. Calibration of analitycal instruments, utilization of gaseous standard mixtures
PublikacjaScharakteryzowano techniki kalibracji jakościowej i ilościowej. Przedstawiono również rolę gazowych mieszanin wzorcowych w procesie kalibracji przyrządów analitycznych oraz wpływ wyboru techniki sporządzania gazowych standardów na spójność pomiarową.
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublikacjaDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Methane (CH4) calibration set of FTIR spectra
Dane BadawczeThe calibration spectra for CH4 concentration calibration were supplied with this dataset
-
Time-Gating method with automatic calibration for accurate measurements of electrically small antenna radiation patterns in Non-Anechoic environments
PublikacjaNon-anechoic sites represent a cheap alternative to measurements of antennas in dedicated facilities. However, due to a high noise—from the external EM signal sources and multipath interferences—the quality of radiation patterns obtained in non-anechoic conditions is poor. The characteristics can be corrected using a time-gating method (TGM), which involves filtering of the noise based on temporal analysis of the measured signals....
-
On Rapid Design Optimization and Calibration of Microwave Sensors Based on Equivalent Complementary Resonators for High Sensitivity and Low Fabrication Tolerance
PublikacjaThis paper presents the design, optimization, and calibration of multivariable resonators for mi-crowave dielectric sensors. An optimization technique for circular complementary split ring reso-nator (CC-SRR) and square complementary split ring resonator (SC-SRR) is presented to achieve the required transmission response in a precise manner. The optimized resonators are manufac-tured using a standard photolithographic technique...
-
The current amplifier in low frequency noise measurements; Absolute calibration and rigorous 1/f noise extraction for MOSFET´s
PublikacjaPrzedstawiono budowę wzmacniacza prądowego i sposób obliczania szumów wyjściowych przy dołączonym do wejścia rezystorze wzorcowym. Przedstawiono wyniki eksperymentów potwierdzających prawidłowość przyjętego sposobu postępowania. Zaproponowano metodę wyznaczania składowej 1/f szumów drenu tranzystora MOSFET.
-
Carbon dioxide (CO2) calibration set of FTIR spectra
Dane BadawczeThe calibration spectra for CO2 concentration calibration were supplied with this dataset
-
Results of calibration of the piezoelectric scanner using the probe TGQ1
Dane BadawczeTeaching file. Results of calibration of the piezoelectric scanner using the probe TGQ1. Scanning in contact mode. NTEGRA Prima (NT-MDT) device. CSG probe 10.
-
Calibration of NTC 10k thermistors in temperature of 0 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 100 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 50 C
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Utilization of standards generated in the process of thermal decomposition chemically modified silica gel for a single point calibration of a GC/FID system
Publikacja -
Thermal decomposition of surface compounds for the generation of small quantities of acetaldehyde. Calibration of a thermal desorption gas chromatography flame ionization detection.
PublikacjaW pracy opisano sposób wytwarzania niewielkich ilości acetaldehydu w procesie termicznego rozkładu związku powierzchniowego uzyskanego w wyniku chemicznej modyfikacji żelu krzemionkowego.Proces rozkładu prowadzony jest w temperaturze 130-190 stopni Celsjusza.Przedstawiono również sposób syntezy prowadzący do uzyskania odpowiedniego związku powierzchniowego.
-
CALIBRATION OF LOW ENERGY X-RAY EXPERIMENTAL SETUP WITH STRONGLY FILTERED BEAM USING DATA FROM A SEMICONDUCTOR AND A THERMOLUMINESCENT DETECTORS
Publikacja -
Machine-learning-based precise cost-efficient NO2 sensor calibration by means of time series matching and global data pre-processing
PublikacjaAir pollution remains a considerable contemporary challenge affecting life quality, the environment, and economic well-being. It encompasses an array of pollutants—gases, particulate matter, biological molecules—emanating from sources such as vehicle emissions, industrial activities, agriculture, and natural occurrences. Nitrogen dioxide (NO2), a harmful gas, is particularly abundant in densely populated urban areas. Given its...
-
Statistical Data Pre-Processing and Time Series Incorporation for High-Efficacy Calibration of Low-Cost NO2 Sensor Using Machine Learning
PublikacjaAir pollution stands as a significant modern-day challenge impacting life quality, the environment, and the economy. It comprises various pollutants like gases, particulate matter, biological molecules, and more, stemming from sources such as vehicle emissions, industrial operations, agriculture, and natural events. Nitrogen dioxide (NO2), among these harmful gases, is notably prevalent in densely populated urban regions. Given...
-
Calibration images under different lighting conditions vol. 1
Dane BadawczeDataset description: Calibration images under different lighting conditions vol. 1
-
Calibration images under different lighting conditions vol. 2
Dane BadawczeDataset description: Calibration images under different lighting conditions vol. 1
-
Carbon (II) oxide (CO) calibration set of FTIR spectra
Dane BadawczeThe calibration spectra for CO concentration calibration were supplied with this dataset
-
High-Performance Machine-Learning-Based Calibration of Low-Cost Nitrogen Dioxide Sensor Using Environmental Parameter Differentials and Global Data Scaling
PublikacjaAccurate tracking of harmful gas concentrations is essential to swiftly and effectively execute measures that mitigate the risks linked to air pollution, specifically in reducing its impact on living conditions, the environment, and the economy. One such prevalent pollutant in urban settings is nitrogen dioxide (NO2), generated from the combustion of fossil fuels in car engines, commercial manufacturing, and food processing. Its...
-
Applicability of glass fiber as a support material for generation of gase ous standard mixtures using thermal decomposition of the surface compound. Calibration of analytical equipment.
PublikacjaW pracy przedstawiono technikę sporządzania gazowych mieszanin wzorcowych(składnikiem mierzonym był eten) w oparciu o termiczny rozkład związków powierzchniowych. Jako nośnik dla związku powierzchniowego zastosowano włókno szklane. W temperaturze 245 stopni Celsjusza związek powierzchniowy ulega rozkładowi bądź przegrupowaniu uwalniając znaną ilość analitu (etenu). Technika ta umożliwia sporządzanie gazowych mieszanin...
-
Calibration of the thermal desorption-gas chromatography-mass spectrometry system using standards generated in the process of thermal decomposition of chemically modified silica gel
Publikacja -
Calibration images under different lighting conditions - static for feature localisation
Dane BadawczeDataset description: Calibration images under different lighting conditions - static mode for feature detection
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Dane BadawczeThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Zeiss calibration dataset for high-precision 3D measurement of large industrial components
Dane BadawczeThe dataset is a collection of images, 2D image points, and 3D points. It serves to calibrate a multi-camera robot system for high-precision measurements of large industrial components (more than 1m x 1m). In particular, the system uses a 3D scanner mounted on a robot manipulator and multiple cameras attached to an external frame outside of the robot...
-
New procedure of silica gel surface modification-preparation of gaseous standard mixtures of methyl chloride using the technique of thermal decomposition of the surface compound for calibration of a TD-GC-FID system.
PublikacjaPrzedstawiono nową procedurę modyfikacji powierzchni żelu krzemionkowego w celu wytworzenia związku powierzchniowego będącego źródłem chlorku metylu. Minimalna temperatura rozkładu (150 st. C) zapewnia trwałość chemicznie modyfikowanego złoża w temp. pokojowej. Badania prowadzono w temperaturze optymalnej (280 st.C). Stwierdzono, że powierzchnia żelu jest obsadzona jednorodnie przez związek powierzchniowy i gazowa mieszanina wzorcowa...
-
A general method for the derivation of the functional forms of the effective energy terms in coarse-grained energy functions of polymers. III. Determination of scale-consistent backbone-local and correlation potentials in the UNRES force field and force-field calibration and validation
Publikacja -
Calibration of permeation passive samplers with silicone membranes based onphysicochemical properties of the analytes. Anal. Chem.**2003 dostępny z Internetu http://pubs3.acs.org/acs/journals/, s. A-K, 6 rys. 7 tab. bib- liogr. 17 poz. Kalibracja permeacyjnych dozymetrów pasywnych z membraną silikonową w opar- ciu o fizykochemiczne właściwości analitów.
PublikacjaW pracy opisano sposób kalibracji pasywnych dozymetrów permeacyjnych, wyko-rzystywanych w badaniach powietrza w oparciu o własności fizykochemiczneanalitów. Stwierdzono silną zależność pomiędzy stałą kalibracyjną (K) dozy-metrów i liczbą atomów węgla w cząsteczce analitu (w obrębie danej grupyzwiązków chemicznych) dla alkoholi, alifatycznych i aromatycznych węglowodo-rów oraz estrów. Taka zależność występuje również pomiędzy...
-
A Biofeedback System that Uses the Game to Study Electrical Muscle Activity
PublikacjaThe aim of this project was to design a system that will allow performing repetitive muscle exercises using a biofeedback device. It is supposed to enhance the motivation and attractiveness of the performed tasks thanks to an interactive game developed for mobile devices with the Android operating system. The built-in calibration mechanisms enable the users to play a game that is independent of their abilities which evens out the...
-
Self-Calibrating Stress Measurement System Based on Multidirectional Barkhausen Noise Measurements
PublikacjaThe system presented in this paper enables automatization of the two-dimensional calibration process (determination of Barkhausen noise (BN) intensity dependence on in-plane components of strain). Then, using dedicated software created by the authors in LabVIEW environment, and with the help of two dimensional calibration data one can effectively determine strain and stress distribution i.e. magnitude and orientation of main strain/stress...
-
Fitting the mobile device characteristics to the user's hearing preferences
PublikacjaA method for fitting the mobile computer audio characteristics to the user's hearing preferences is proposed. The process consists of two stages: calibration and dynamics processing. During the calibration phase the user performs a loudness scaling test giving their response regarding the perceived loudness. The dynamics processing made on above basis sets the loudness to the most comfortable level. The processing accounts both...
-
Intelligent PI controller and its application to dissolved oxygen tracking problem
PublikacjaThe paper addresses design, calibration, implementation and simulation of the intelligent PI controller used for dissolved oxygen (DO) tracking in wastewater treatment plant (WWTP). The calibration process presented in this paper utilizes both engineering and scientific methods. Verification of the control system design method was obtained via simulation experiments.
-
RSS-Based DoA Estimation Using ESPAR Antenna Radiation Patterns Spline Interpolation
PublikacjaIn this paper, it is shown how power pattern crosscorrelation (PPCC) algorithm, which relies on received signal strength (RSS) values recorded at electronically steerable parasitic array radiator (ESPAR) antenna output port, used for direction-of-arrival (DoA) estimation, can easily be improved by applying spline interpolation to radiation patterns recorded in the calibration phase of the DoA estimation process. The proposed method...
-
Application of Web-GIS and Cloud Computing to Automatic Satellite Image Correction
PublikacjaRadiometric calibration of satellite imagery requires coupling of atmospheric and topographic parameters, which constitutes serious computational problems in particular in complex geographical terrain. Successful application of topographic normalization algorithms for calibration purposes requires integration of several types of high-resolution geographic datasets and their processing in a common context. This paper presents the...
-
Wpływ automatycznej kalibracji wizyjnego systemu pozycjonowania na dokładność lokalizacji elementu roboczego
PublikacjaW artykule przedstawiono strukturę i działanie automatycznego wizyjnego systemu pozycjonowania (PVS), który został zainstalowany na maszynie waterjet (WJ). Ponadto przeprowadzono analizę wpływu kalibracji na działanie PVS. Podstawę systemu stanowią dwie kamery internetowe zamontowane na przemysłowej maszynie WJ. W połączeniu z algorytmem identyfikacji, system przeznaczony jest do pozycjonowania WJ z dużą dokładnością. W tym celu...
-
Generation of inhibitory compounds during pre-treatment of lignocellulosic biomass
Dane BadawczeDataset contains calibration curves and typical resultsa obtained during biomass pre-treatment. Data are converted from digital raw files to xlsx files
-
Change of exhaust gases concentration for LSCNT modified SOFC fueled by biogas mixture at 750 C
Dane BadawczeThe dataset changes of exhaust gases concentrations (CH4,CO,CO2,H2) over working time for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer. Concentrations were calculated based on the FTIR measurements and calibration files presented in coupled dataset.
-
New insights into modeling two-step nitrification in activated sludge systems – The effects of initial biomass concentrations, comammox and heterotrophic activities
PublikacjaIn this study, the conventional two-step nitrification model was extended with complete ammonia oxidation (comammox) and heterotrophic denitrification on soluble microbial products. The data for model calibration/validation were collected at four long-term washout experiments when the solid retention time (SRT) and hydraulic retention time (HRT) were progressively reduced from 4 d to 1 d, with mixed liquor suspended solids (MLSS)...
-
Jakub Konkol dr inż.
Osoby -
RSS-based DoA Estimation Using ESPAR Antennas and Interpolated Radiation Patterns
PublikacjaIn this letter, it is shown how an algorithm, which employs received signal strength (RSS) values in order to estimate direction-of-arrival (DoA) of impinging signals in wireless sensor network (WSN) nodes equipped with electronically steerable parasitic array radiator (ESPAR) antennas, can easily be improved by applying an interpolation algorithm to radiation patterns recorded in the calibration phase of the DoA estimation process....