Filtry
wszystkich: 1359
-
Katalog
- Publikacje 1106 wyników po odfiltrowaniu
- Czasopisma 29 wyników po odfiltrowaniu
- Konferencje 11 wyników po odfiltrowaniu
- Wydawnictwa 1 wyników po odfiltrowaniu
- Osoby 6 wyników po odfiltrowaniu
- Wynalazki 1 wyników po odfiltrowaniu
- Projekty 13 wyników po odfiltrowaniu
- Zespoły Badawcze 4 wyników po odfiltrowaniu
- Aparatura Badawcza 1 wyników po odfiltrowaniu
- Kursy Online 31 wyników po odfiltrowaniu
- Dane Badawcze 156 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: SENSOR
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Experimental dataset on detection of SARS-CoV-2 specific IgG antibodies by the fiber optic microsphere-based sensor
Dane BadawczeThe presented dataset is related to experimental detection of the ARS-CoV-2 specific IgG antibodies by the fibre optic microsphere-based sensor. To perform measurement we used a dedicated microsphere-based probe whose surface was immobilized.
-
SENSORS AND ACTUATORS B-CHEMICAL
Czasopisma -
ACM Conference on Embedded Networked Sensor Systems
Konferencje -
On the sensitivity, selectivity, sensory information and optimalsize of resistive chemical sensors
PublikacjaWykorzystano pojęcia teorii informacji do określenia możliwości poprawy selektywności i czujności rezystancyjnych sensorów gazu. Podano ogólne rozważania dotyczące limitu selektywnoœci dla tych sensorów. Porównano iloraz sygnału do szumów oraz pojemność kanału informacyjnego dla sensorów chemicznych wykorzystujących jako sygnał zjawiska fluktuacyjne z klasycznymi sensorami charakteryzowanymi jedną wartością. Ogólne rozważania wsparto...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.2
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.1
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.3
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.5
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - microsphere inspection s.4
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
SENSORYKA ROBOTÓW [2022/23]
Kursy Online -
SENSORYKA ROBOTÓW [2021/22]
Kursy Online -
SENSORYKA ROBOTÓW [2023/24]
Kursy Online -
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 300 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 200 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated (100 nm) microsphere-based fiber-optic sensor - 100 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 100 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
IEEE International Conference on Distributed Computing in Sensor Systems
Konferencje -
Workshop on Localized Algorithms and Protocols for Wireless Sensor Networks
Konferencje -
Badania nad potencjometrycznymi sensorami smaku
PublikacjaPrzedstwiono badania nad 5-kanałowym sensorem smaku kwasnego, zbudowanym z elektrod z membranami polimerowo - lipidowymi zawierającymi odpowiednie lipidy. Stwierdzono, że sensor ten jest bardzo czuły na zmainy stężenia kwasu cytrynowego, natomiast wykazuje nieco gorszą czułosc na obecnosć kwasu octowego. Stwirdzono dobrą trwałosć membran oraz powtarzalnośc otrzymanych wyników. Wydaje się, że badane układy mogą byc wykorzystane...
-
European Workshop on Security and Privacy in Ad -Hoc and Sensor Networks
Konferencje -
Workshop on Theoretical and Algorithmic Aspects of Sensor and Ad-hoc Networks
Konferencje -
IEEE International Conference on Mobile Ad-hoc and Sensor Systems
Konferencje -
IEEE SENSORS JOURNAL
Czasopisma -
Inteligentne systemy sensorowe 2022
Kursy Online -
Mikroprocesorowy system sterowania sensorami z inerfejsem USB
PublikacjaZapotrzebowanie na detekcję gazów oraz zapachów wymaga konstruowania tanich urządzeń o coraz lepszej selektywności i czułości pomiarów. W pracy opisano taki układ pomiarowy, w którym zwiększenie selektywności oraz czułości uzyskano przez pomiar zjawisk fluktuacyjnych w rezystancyjnym czujniku gazów. Opisano sposób pomiaru, wybrany układ pomiarowy oraz projekt i realizację systemu mikroprocesorowego sterującego układem. W zakończeniu...
-
Ruting w sieciach sensorowych typu ad hc
PublikacjaW artykule przedstawiono zagadnienia dotyczące rutingu w nowoczesnych sieciach sensorowych typu ad hoc.Omówiono tematykę rutingu w mobilnych sieciach komputerowych typu ad hoc (podział i opis najbardziej popularnych protokołów rutingu). Scharakteryzowano cechy sieci sensorowych ad hoc i wymagania jakie stawiają procesom rutingu. Przedstawiono czynniki wpływające na wydajność rutingu w nowoczesnej sieci czujników i oceniono przydatność...
-
Bezprzewodowe zasilanie sensorów medycznych
PublikacjaW artykule przedstawiono problematykę bezprzewodowego zasilania miniaturowych sensorów medycznych. Przedyskutowano specyfikę bezprzewodowej transmisji mocy elektrycznej do sensorów, zwracając uwagę na potrzebę stosowania tej formy zasilania oraz na ograniczenia wynikające z limitów gęstości mocy dopuszczalnej dla żywych organizmów, w szczególności dla człowieka. Zaproponowano nowe podejście do bezprzewodowego przesyłu mocy wykorzystujące...
-
Bezprzewodowe zasilanie sensorów medycznych
PublikacjaW artykule przedstawiono problematykę bezprzewodowego zasilania miniaturowych sensorów medycznych. Przedyskutowano specyfikę bezprzewodowej transmisji mocy elektrycznej do sensorów, zwracając uwagę na potrzebę stosowania tej formy zasilania oraz na ograniczenia wynikające z limitów gęstości mocy dopuszczalnej dla żywych organizmów, w szczególności dla człowieka. Zaproponowano nowe podejście do bezprzewodowej transmisji mocy wykorzystujące...
-
Protokół transmisji sensorowej sieci Ad Hoc
PublikacjaW referacie zaprezentowano protokół radiowej sieci sensorowej Ad Hoc. Sieć ta pracuje w oparciu o metodę wielodostępu TDMA. Szybkość transmisji w kanale radiowym wynosi 57,6 kb/s. W referacie przedstawiono budowę ramek, rodzaje pakietów oraz procedury przypisania wolnych szczelin czasowych do węzła, zwalniania przypisanych szczelin i wykrywania konfliktów przyporządkowania szczelin.
-
Utilization of a Non-Linear Error Function in a Positioning Algorithm for Distance Measurement Systems Designed for Indoor Environments
PublikacjaA new positioning algorithm for distance measurement systems is outlined herein. This algorithm utilizes a non-linear error function which allows us to improve the positioning accuracy in highly difficult indoor environments. The non-linear error function also allows us to adjust the performance of the algorithm to the particular environmental conditions. The well-known positioning algorithms have limitations, mentioned by their...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublikacjaIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...
-
Metody analizy sensorycznej jako narzędzie do oceny uciążliwości zapachowej powietrza atmosferycznego. CZ. II. Charakterystyka metod analizy sensorycznej.
PublikacjaZwiązki chemiczne obecne w powietrzu atmosferycznym i wywołujące nieprzyjemne wrażenia zapachowe mogą wywierać negatywny wpływ na zdrowie i życie człowieka. Wszystkie niepożądane substancje zapachowe, powodujące pobudzenie narządu węchowego, a następnie odczuwanie zapachu, nazywane są odorantami. Do pomiaru reakcji człowieka na bodźce pochodzące z otaczającego środowiska wykorzystuje się metody analizy sensorycznej. Umożliwia to...
-
Workshop on Applications of Graph Theory in Wireless Ad hoc Networks and Sensor Networks
Konferencje -
Zintegrowane sieci sensorowe 2023/24
Kursy OnlineCel przedmiotu: Zapoznanie z budową, możliwościami i aplikacjami zintegrowanych sieci sensorowych.
-
Zintegrowane sieci sensorowe 2022/23
Kursy OnlineCel przedmiotu: Zapoznanie z budową, możliwościami i aplikacjami zintegrowanych sieci sensorowych.
-
Zintegrowane sieci sensorowe 2021/22
Kursy OnlineCel przedmiotu: Zapoznanie z budową, możliwościami i aplikacjami zintegrowanych sieci sensorowych.
-
Inteligentne systemy sensorowe [2023/24]
Kursy Online -
Zastosowanie przetworników jonoczułych typu isfet w bezprzewodowych sieciach sensorowych
PublikacjaW pracy przedstawiono zasadę działania pH-metrycznych czujników ISFET, ich istotne układy pracy oraz wady i zalety w analizie elektrochemicznej w środowiskach wodnych i niewodnych. Określono wymagania dla przetworników pracujących w warunkach polowych, poza laboratorium. Przedstawiono technologię bezprzewodowych sieci sensorowych. Zaproponowano układ węzła sensorowego ze skompensowanym termicznie różnicowym przetwornikiem ISFET...
-
SENSORS AND ACTUATORS A-PHYSICAL
Czasopisma -
Algoritmically improved microwave radar monitors breathing more acurrate than sensorized belt
PublikacjaThis paper describes a novel way to measure, process, analyze, and compare respiratory signals acquired by two types of devices: a wearable sensorized belt and a microwave radar-based sensor. Both devices provide breathing rate readouts. First, the background research is presented. Then, the underlying principles and working parameters of the microwave radar-based sensor, a contactless device for monitoring breathing, are described....