Filtry
wszystkich: 1391
-
Katalog
- Publikacje 781 wyników po odfiltrowaniu
- Czasopisma 35 wyników po odfiltrowaniu
- Konferencje 4 wyników po odfiltrowaniu
- Osoby 11 wyników po odfiltrowaniu
- Wynalazki 4 wyników po odfiltrowaniu
- Projekty 1 wyników po odfiltrowaniu
- Kursy Online 14 wyników po odfiltrowaniu
- Dane Badawcze 541 wyników po odfiltrowaniu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: BONE-IMPLANT INTERFACE
-
Bile salts in digestion and transport of lipids
PublikacjaBecause of their unusual chemical structure, bile salts (BS) play a fundamental role in intestinal lipid digestion and transport. BS have a planar arrangement of hydrophobic and hydrophilic moieties, which enables the BS molecules to form peculiar self-assembled structures in aqueous solutions. This molecular arrangement also has an influence on specific interactions of BS with lipid molecules and other compounds of ingested food...
-
SIMULATION OF PROCEED® SURGICAL MESH APPLIED TO VENTRAL HERNIA REPAIR
PublikacjaIn the present research, Proceed® implant is considered. The system is subjected to short-time dynamic pressure load, similar to post-operative cough naturally occurring in human abdomen. The model refers to a clinical case of 5cm of hernia operated by Proceed implant fixed by 15 joints every 3cm around the orifice. The simulations of the implanted mesh are performed by means of the Finite Element Method. The implant is modelled...
-
A new finite element with variable Young's modulus
PublikacjaThe Finite Element Method (FEM) is a numerical technique that is well-established in the field of engineering. However, in biological sciences, it is justtaking its first steps. Bone tissue is an example of biological material which isexposed to high loads in its natural environment. Practically every movementof the body results in changing stress levels in the bone. Nature copes with thisvery well but when human intervention is...
-
Method of Skeletal System Modelling
PublikacjaAn original method of skeletal system modelling is presented in detail. Using DICOM images obtained from CT and PET tests, shell models of nine bones were created (humerus, radius, ulna, scapula, clavicle, femur, tibia, fibula, pelvis). Two methods of bone behaviour are also proposed, the first method treating the bone as a solid structure and the second method treating the bone as a complex porous structure. The behaviour of model...
-
High-dose chemotherapy with autologous stem cell transplantation is an effective treatment of primary refractory Hodgkin's disease. Retrospective study of the Polish Lymphoma Research Group
Publikacja -
Radioimmunotherapy with 90Y-ibritumomab tiuxetan is a safe and efficient treatment for patients with B-cell lymphoma relapsed after auto-SCT: an analysis of the international RIT-Network
Publikacja -
Karolina Krośnicka dr hab. inż. arch.
OsobyKarolina A. Krośnicka, dr hab. inż. arch., jest profesorem uczelni w Katedrze Projektowania Urbanistycznego i Planowania Regionalnego na Wydziale Architektury Politechniki Gdańskiej. Przez wiele lat (1998-2016) była zatrudniona w Katedrze Transportu i Logistyki na Wydziale Nawigacyjnym Akademii Morskiej w Gdyni, gdzie zajmowała się głównie zagadnieniami związanymi z planowaniem portów morskich i terminali portowych. Obecnie jej...
-
Towards Understanding of Mechanics of Hernia Managed by Synthetic Mesh in Laparoscopic Operation: A Single Case Study
PublikacjaIn this paper a research towards understanding of mechanics of ventral hernia operated with the use of Physiomesh Open image in new window implant and SecureStrap Open image in new window staples is described. Experimental and numerical studies are conducted for that purpose. Experimental works cover uni-axial tension tests of the implant samples and of the implant-staples-tissue system. Also experiments on implant-staples-tissue...
-
Materiały stosowane do wytwarzania implantów kości
PublikacjaMateriały stosowane do wytwarzania implantów kostnych muszą być biokompatybilne, nietoksyczne, bioaktywne oraz wykazywać odpowiednie właściwości mechaniczne, takie jak wytrzymałość na ściskanie, na zginanie oraz sztywność i twardość. Gama stosowanych materiałów jest bardzo szeroka, obejmuje metale, polimery, ceramikę oraz ich kompozyty. Każdy z tych materiałów ma swoje mocne i słabe strony. Praca stanowi przegląd materiałów stosowanych...
-
Structural and Material Determinants Influencing the Behavior of Porous Ti and Its Alloys Made by Additive Manufacturing Techniques for Biomedical Applications
PublikacjaOne of the biggest challenges in tissue engineering is the manufacturing of porous structures that are customized in size and shape and that mimic natural bone structure. Additive manufacturing is known as a sufficient method to produce 3D porous structures used as bone substitutes in large segmental bone defects. The literature indicates that the mechanical and biological properties of scaffolds highly depend on geometrical features...
-
Degradable poly(ester-ether) urethanes of improved surface calcium deposition developed as novel biomaterials
PublikacjaBones, which are considered as hard tissues, work as scaffold for human body. They provide physical support for muscles and protect intestinal organs. Percentage of hard tissues in human body depends on age, weight, and gender. Human skeleton consists of 206 connected bones. Therefore, it is natural that the hard-tissue damage such as fractures, osteoporosis, and congenital lack of bone may appear. The innovative way of bone healing...
-
Modyfikacja cementu kostnego w celu uzyskania długotrwałej ochrony antybakteryjnej
PublikacjaNiniejsza rozprawa doktorska stanowi przewodnik po jednotematycznym cyklu publikacji, dotyczącym modyfikacji akrylowego cementu kostnego celem uzyskania długotrwałej i efektywnej ochrony antybakteryjnej. W ramach niego przeprowadzono badania eksperymentalne polegające na opracowaniu technologii wytwarzania modyfikowanego cementu kostnego oraz procedury medycznej jego stosowania. Cement kostny był modyfikowany przez zastosowanie...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublikacjaThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...
-
Underwater welded joint properties investigation
PublikacjaPrzeprowadzono badania mikro- i makroskopowe złączy spawanych typu implant wykonanych pod wodą metodą lokalnej komory suchej. Wyniki badań świadczą o tym, że w SWC badanych złączy tworzą się kruche struktury hartownicze, które są odpowiedzialne za zwiększoną skłonność stali o podwyższonej wytrzymałości do tworzenia pęknieć zimnych. Analiza rozkładów twardości złączy implant również potwierdza istnienie szkodliwego wpływu środowiska...
-
Nanotubular oxide layer formed on helix surfaces of dental screw implants - SEM examination
Dane BadawczeThe samples used for the research had the shape of a helix with a metric thread, with their geometry imitating a dental implant. The oxide layer was produced by a standard electrochemical method in an environment of 1M H3PO4 + 0.3 % HF for 20 min, at a constant voltage of 30 V. The oxidized samples were analyzed with a scanning electron microscope.
-
Polyurethane Composite Scaffolds Modified with the Mixture of Gelatin and Hydroxyapatite Characterized by Improved Calcium Deposition
PublikacjaThe skeleton is a crucial element of the motion system in the human body, whose main function is to support and protect the soft tissues. Furthermore, the elements of the skeleton act as a storage place for minerals and participate in the production of red blood cells. The bone tissue includes the craniomaxillofacial bones, ribs, and spine. There are abundant reports in the literature indicating that the amount of treatments related...
-
Variable Order Differential Models of Bone Remodelling * *This work was supported by FCT, through IDMEC, under LAETA, projects UID/EMS/50022/2013, BoneSys, joint Polish-Portuguese project Modelling and controlling cancer evolution using fractional calculus, PERSEIDS (PTDC/EMS-SIS/0642/2014) and IF/00653/2012
Publikacja -
Metal implants in ostheosynthesis - construction solutions, materials and applications
PublikacjaThe aim of the article is to present two case studies on intramedullary nails. The research included the evaluation of the type of fracture and the analysis of microstructure, chemical composition and hardness of the implant material.
-
Mechanical compatibility of implants used in hernia repair with abdominal wall
PublikacjaThe paper deals with a membrane model of a synthetic surgical mesh for treatment of abdominal hernia. The authors analyse the compatibility of two implant types with the human wall: Dualmesh Gore and Proceed. The finite element method is applied to simulate tjhe behavior of the proposed model. Due fact that recurrences are usually caused by connection failure, this study is focused on reaction forces in supports representing the...
-
SEM images of cross sections of porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes sintered at different temperatures
Dane BadawczeThis dataset contains cross sectional images of the porous Sr0.86Ti0.65Fe0.35O3 oxygen electrodes symmetric cells samples interface. Here are presented images of electrodes sintered at 950 °C, 1000 °C and 1050 °C. Images were obtained using a FEI Quanta FEG 250 Scanning Electron Microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum...
-
The degradation of metal implants
PublikacjaThe presence of metal implants in the human body causes some dangers, which result from introducing another object into organism. There may occur a biocorrosion, which causes different modifications of implant surface.
-
Efficiency of exciton splitting in organic photovoltaic cells within EQE spectrum
PublikacjaThe paper presents a procedure of estimating the efficiency of exciton splitting at ED/EA interface. The procedure consists in evaluation of splitting of excitons into electron-hole pairs on the basis of the external quantum efficiency spectra of planar cells and spectra of absorbance of active organic layers. The fitting parameters are the exciton splitting probabilities at ED/EA interface. The presented procedure was applied...
-
Assessment of the Relationship between the Shape of the Lateral Meniscus and the Risk of Extrusion Based on MRI Examination of the Knee Joint
PublikacjaBackground Meniscus extrusion is a serious and relatively frequent clinical problem. For this reason the role of different risk factors for this pathology is still the subject of debate. The goal of this study was to verify the results of previous theoretical work, based on the mathematical models, regarding a relationship between the cross-section shape of the meniscus and the risk of its extrusion. Materials and Methods Knee...
-
Polyurethanes Crosslinked with Poly(vinyl alcohol) as a Slowly-Degradable and Hydrophilic Materials of Potential Use in Regenerative Medicine
PublikacjaNovel, slowly-degradable and hydrophilic materials with proper mechanical properties and surface characteristics are in great demand within the biomedical field. In this paper, the design, synthesis, and characterization of polyurethanes (PUR) crosslinked with poly(vinyl alcohol) (PVA) as a new proposition for regenerative medicine is described. PVA-crosslinked PURs were synthesized by a two-step polymerization performed in a solvent...
-
Some Aspects of Shear Behavior of Soft Soil–Concrete Interfaces and Its Consequences in Pile Shaft Friction Modeling
PublikacjaThis paper examines the stiffness degradation and interface failure load on soft soil–concrete interface. The friction behavior and its variability is investigated. The direct shear tests under constant normal load were used to establish parameters to hyperbolic interface model which provided a good approximation of the data from instrumented piles. Four instrumented piles were used to obtain reference soil–concrete interface behavior....
-
Electrophoretically Deposited Chitosan/Eudragit E 100/AgNPs Composite Coatings on Titanium Substrate as a Silver Release System
PublikacjaDue to the possibility of bacterial infections occurring around peri-implant tissues, it is necessary to provide implant coatings that release antibacterial substances. The scientific goal of this paper was to produce by electrophoretic deposition (EPD) a smart, chitosan/Eudragit E 100/silver nanoparticles (chit/EE100/AgNPs) composite coating on the surface of titanium grade 2 using different deposition parameters, such as the...
-
Modeling of flow phenomena on the mould plastic interface associated withpolymer injection. Trends Production Technol.**2002 Bd 3 s. 122-137, 11 rys Proceedings of the International Colloquium on Production Science. Gdańsk, April 15th 2002. Ed. D. Spaht. Modelowanie zjawisk zachodzących podczas wtrysku w strefie tworzywo-forma.
PublikacjaPodczas wtrysku występują w warstwie tworzywa przy ściance formy zjawiska,które są źródłem wad. Opisano powyższe zjawiska oraz zaprezentowano model zachowania się tworzywa w strefie przyściennej z wykorzystaniem symulacji komputerowej procesu wtrysku. Symulację wykonano na komputerach CI TASK przyuzyciu programu FIDAP. Ponadto przedstawiono wyniki badań doświadczalnych w postaci fotografii i profilogramów powierzchni, które...
-
Effect of heat treatment on the diffusion intermixing and structure of the Cu thin film on Si (111) substrate: a molecular dynamics simulation study
PublikacjaThis work is devoted to the study of the diffusion process at the interface between copper films with a thickness of 2, 3, 4, 7 and 10 atomic monolayers and silicon substrate by molecular dynamics simulation method. For this purpose, the variation of the concentration of copper and silicon along the perpendicular direction to the interface was investigated. An analysis of the density profile along this direction made it possible...
-
Numerical Model of Femur Part
PublikacjaThe aim of the study is to create a new more accurate method of femur part modelling by using the finite element method. According to this new method, a femur part is treated as a complex structure composed of trabecular bone (internal part) and cortical bone (external part). The internal part is modelled as a scaffold, thus the external part is modelled as a coat (i.e. covering). Applying the programme ABAQUS, there were created...
-
Experimental study on the effect of selected sterilization methods on mechanical properties of polylactide FFF specimens
PublikacjaPurpose: Biodegradable polymers are widely used in personalized medical devices or scaffolds for tissue engineering. The manufacturing process should be finished with sterilization procedure. However, it is not clear how the different sterilization methods have an impact on the mechanical strength of the three-dimensional (3D)-printed parts, such as bone models or personalized mechanical devices. This paper aims to present the...
-
Titania Nanofiber Scaffolds with Enhanced Biointegration Activity—Preliminary In Vitro Studies
PublikacjaThe increasing need for novel bone replacement materials has been driving numerous studies on modifying their surface to stimulate osteogenic cells expansion and to accelerate bone tissue regeneration. The goal of the presented study was to optimize the production of titania-based bioactive materials with high porosity and defined nanostructure, which supports the cell viability and growth. We have chosen to our experiments TiO2...
-
Extended non-linear relations of elastic shells undergoing phase transitions
PublikacjaThe non-linear theory of elastic shells undergoing phase transitions was proposed by two first authors in J. Elast. 79, 67-86 (2004). In the present paper the theory is extended by taking into account also the elastic strain energy density of the curvilinear phase interface as well as the resultant forces and couples acting along the interface surface curve itself. All shell relations are found from the variational principle of...
-
Hip endhoprothesis development using rapid prototyping methods
PublikacjaIntegrated product development based on Rapid Prototyping methods, connected with computer aided 3D design and computer aided engineering enables fast and full new product verification and validation. A case study derived from clinical and technological practice using hip implant construction is also included.
-
Comparative 3D DEM simulations of sand–structure interfaces with similarly shaped clumps versus spheres with contact moments.
PublikacjaThree-dimensional simulations of a monotonic quasi-static interface behaviour between initially dense cohesionless sand and a rigid wall of different roughness during tests in a parallelly guided direct shear test under constant normal stress are presented. Numerical modelling was carried out by the discrete element method (DEM) using clumps in the form of convex non-symmetric irregularly shaped grains. The clumps had an aspect...
-
Forming of the gap in tendon sutures with the Kessler suture
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the gap formation process between the fronts of the connected tendons was observed. Tendons from fresh swine legs (commercially available) served as the biological material. The tendon juncture...
-
Skłonność złączy wykonanych pod wodą do tworzenia pęknięć zimnych
PublikacjaPrzedmiotem pracy jest analiza stanu wiedzy dotyczącej skłonności do tworzenia peknięć zimnych złączy wykonanych pod wodą. Omówiono wpływ warunków spawania na czynniki będące przyczyną pękania. Przedstawiono wyniki badań złączy ze stali o podwyższonej wytrzymałości metodą implant.
-
Nanotubular oxide layers and hydroxyapatite coatings on porous titanium alloy Ti13Nb13Zr
PublikacjaThe surface condition of an implant has a significant impact on response occurring at the implant-biosystem border. The knowledge of physical-chemical and biological processes allows for targeted modification of biomaterials to induce a specified response of a tissue. The present research was aimed at development of technology composing of obtaining the nanotube oxide layers on a porous titanium alloy Ti13Nb13Zr, followed by the...
-
Structural changes of bacterial cellulose due to incubation in conditions simulating human plasma in the presence of selected pathogens
PublikacjaBacterial nanocellulose (BNC) is a natural biomaterial with a wide range of medical applications. However, it cannot be used as a biological implant of the circulatory system without checking whether it is biodegradable under human plasma conditions. This work aimed to investigate the BNC biodegradation by selected pathogens under conditions simulating human plasma. The BNC was incubated in simulated biological fluids with or...
-
Design of radio communication systems for unmanned transport applications
PublikacjaIn the paper the principle of OFDMA-based radio communication systems design for unmanned transport applications is presented. The concept of system radio interface is analysed and its basic parameters proposal are considered. In the last part of the paper some air interface characteristics useful for optimization of throughput and system capacity are considered.
-
Robotics for human health and performance (PG_00054982) 04.2024
Kursy OnlineDuring this course students will be provided with the knowledge in areas of robotics and biomechanics necessary to design instrumentation for human health and performance, as well as about human-robot interface.
-
Smart Healthy Age-Friendly Environments (SHAFE) Bridging Innovation to Health Promotion and Health Service Provision
Publikacja -
Forming of the gap in tendon sutures with an anchor without a pin
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the gap formation process between the fronts of the connected tendons was observed. Tendons from fresh swine legs (commercially available) served as the biological material. The tendon juncture...
-
Forming of the gap in tendon sutures with an anchor with a pin
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the gap formation process between the fronts of the connected tendons was observed. Tendons from fresh swine legs (commercially available) served as the biological material. The tendon juncture...
-
Maximum forces in tendon connections for an anchor with a pin in the full sample experiment
Dane BadawczeThe main objective of the all study was to assess the load capacity of a new implant device for knotless tendon anastomosis. During this series of experiments the load capacity of the anchoring element with a pin (see figure 1) was examined. Tendons from fresh swine legs (commercially available) served as the biological material. All samples were subjected...
-
Effect of welding conditions on susceptibility to cold cracking of underwater welded joints
PublikacjaPrzedstawiono wybrane aspekty spawalności stali przy spawaniu pod wodą metodą lokalnej komory suchej. Zwrócono szczególną uwagę na skłonność do tworzenia peknięć zimnych w SWC. Przy pomocy planowania doświadczeń określono ilościowy wpływ parametrów spawania na naprężenia krytyczne z próby implant.
-
Medially positioned plate in first metatarsophalangeal joint arthrodesis
PublikacjaObjective The purpose of this study was to biomechanically compare the stability of first metatarsophalangeal (MTP1) joint arthrodesis with dorsally and medially positioned plates. Methods A physical model of the MTP1 joint consists of printed synthetic bones, a titanium locking plate and screws. In the experiments, samples with dorsally and medially positioned plates were subjected to loading of ground load character in a universal...
-
BJS-03 DO WE NEED FIXATION OF THE MESH IN LAPAROENDOSCOPIC TECHNIQUES FOR M3 INGUINAL DEFECTS? AN EXPERIMENTAL STUDY
PublikacjaThe authors conducted a research experiment to verify the hypothesis that it is possible to preserve the mesh in the operating field in large direct hernias (M3) without the need to use fixing materials. The results showed that mesh fixation is not the only alternative to preventing recurrence in complex defects and that the type of implant seems to be a key factor from the point of view of mechanics and biophysics.
-
Evaluation of the Cathodic Electrodeposition Effectiveness of the Hydroxyapatite Layer Used in Surface Modification of Ti6Al4V-Based Biomaterials
PublikacjaThe important issue associated with the design and the fabrication of the titanium and titanium alloy implants is the increase of their biointegration with bone tissue. In the presented paper, the research results concerning the conditions used in the cathodic deposition of hydroxyapatite on the surface Ti6Al4V substrates primarily modified by the production of TiO2 nanoporous coatings, TiO2 nanofibers, and titanate coatings, are...
-
Robotics for human health and performance 03.2022
Kursy OnlineThis course is to provide knowledge in area of biomechanics, necessary to design instrumentation for human health and performance, and automatics necessary to design simple instrumentation as well as about human-robot interface.
-
Self-Organized Nanotubular Oxide Layers on Ti and Ti Alloys
PublikacjaTo improve bioactivity of titanium and titanium, the implant surface modification by formation of self-organized TiO2 nanotube arrays with electrochemical techniques is presented. The influence of electrolyte composition and deposition parameters during anodization is characterized. The enhancement of phosphates deposition by titanium nanotubular structure is discussed. The calcium phosphate ceramics is shown to be uniformly deposited...