Filtry
wszystkich: 1960
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: VOLTAGE DOUBLER
-
Common-Mode Voltage and Bearing Currents in PWM Inverters: Causes, Effects and Prevention
PublikacjaIn modern induction motor drives an increase of transistors' switching frequency and a decrease of switching times are the sources of some serious problems. The high dv/dt and the common mode voltage generated by the inverter PWM control results in the appearances of bearing currents, shaft voltages, motor terminal overvoltages, the decrease of motor efficiency, and electromagnetic interference. The aspects of common mode (CM)...
-
Problems of Selecting Protection for Shunt Reactors Working in Extra-High Voltage Grids
PublikacjaThis paper presents difficulties encountered when designing protection devices for shunt reactors connected directly to extra-high voltage grids. Using the example of the 400 kV Ełk Bis substation, it has been demonstrated that protection of a shunt reactor based on equipment using measurements of electrical signals from voltage and current transformers has its limitations and, in some cases, may be insufficient.
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublikacjaThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublikacjaThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Numbers, Please: Power- and Voltage-Related Indices in Control of a Turbine-Generator Set
PublikacjaThis paper discusses the proper selection and interpretation of aggregated control performance indices values mirroring the quality of electrical energy generation by a turbine-generator set cooperating with a power system. Typically, a set of basic/classical and individual indices is used in energy engineering to ensure the mirroring feature and is related to voltage, frequency and active or reactive power deviations from their...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Case studies of resonance phenomena in high voltage overhead power lines with shunt reactors
PublikacjaMisguided design of the towers of power transmission lines can lead to serious problems such as voltage asymmetry, overvoltages, electric arc extinction difficulties or resonance – in case of double circuit line with shunt reactors. The paper points out those threats on example of 400 kV double circuit overhead transmission line with shunt reactors.
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
Publikacja -
Errors in the analysis of series resonant inverter/converter assuming sinusoidal waveforms of voltage and current
PublikacjaIn this paper the theory and simulation results of the series resonant inverter / converter are presented. In this work the authors carried out a detailed comparative analysis of results obtained using the method of AC analysis in the steady state for the first harmonic with the results of computer simulation. The AC analysis under certain conditions can lead to errors disqualifying this method. In particular, these errors appear...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publikacja—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Impact of power electronic Var compensators installed in certain grid points on the voltage failure
PublikacjaThe article presents the test results of the various types of static compensators FACTS models in the power system. The basic case, which was analyzed, it was behavior of compensators which are installed in select points of the system during voltage failure. The article presents selected results of studies conducted as part of a work [2].
-
Design of hight voltage busbar: trade off between electrical field and stray inductance
PublikacjaArtykuł dotyczy optymalizacji konstrukcji i technologii szyny doprowadzenia zasilania do pojedynczej gałęzi falownika średniego napięcia. Dla szeregowego układu złożonego z trzech modułów elektroizolowanych (6 par tranzystorów i diod) rozważono warianty geometrii szyny zasilania przy uwzględnieniu wypadkowej indukcyjności obwodu komutacyjnego. Wyznaczono główne składniki indukcyjności rozproszenia oraz wykazano jej wpływ na przepięcia...
-
Random components influence on the values characterising periodic disturbances in low voltage supply lines.
PublikacjaAnalizowano wpływ składowych losowych na wielkości charakteryzujących zaburzenia okresowe w napięciu zasilania na przykładzie współczynnika zawartości harmonicznych (THD). Zaprezentowano sposób wyznaczania niepewności pomiaru współczynnika THD, uwzględniający występowanie korelacji pomiędzy składową podstawową i kolejnymi harmonicznymi napięcia sieci a także między poszczególnymi harmonicznymi. Przedstawiono analizę wyników z pomiarów...
-
Sensorless control system of induction machine supplied by voltage source inverter with output filter
PublikacjaThe paper focuses on sensorless control of the induction machines supplied by inverter with the output filters. “The novel” idea of the speed observer which is based on the backstepping approach is shown. The standard structure of the exponential observer is extended by the integrators and additional Z vector. The simulation and experimental results validate the proposed solution.
-
Research of chitosan coatings deposited by electrophoretic deposition method at various voltage and time parameters
PublikacjaThe aim of this research is to estimate the electrophoretic deposition main parameters, such as voltage and time duration, that will provide optimal characteristics of the surface layer. Chitosan coatings were synthesized on biomedical Ti13Zr13Nb alloys at 20 V and 30 V and with deposit times of 2min, 5 min, 10 min, and 15 min. Evaluation of the coating was performed by using Scanning Electron Microscope (SEM), Energy-Dispersive...
-
Study of Nanohydroxyapatite Coatings Prepared by the Electrophoretic Deposition Method at Various Voltage and Time Parameters
PublikacjaThe aim of the work is to compare the properties of nanohydroxyapatite coatings obtained using the electrophoretic deposition method (EDP) at 10 V, 20 V, and 30 V, and with deposit times of 2 and 5 min. The primary sedimentation was used to minimize the risk of the formation of particle agglomerates on the sample surface. Evaluation of the coating was performed by using a Scanning Electron Microscope (SEM), Energy-Dispersive Spectroscopy...
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublikacjaThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Analysis of inductive power transfer systems for variable air gap and voltage supply frequency
PublikacjaThe paper describes an IPT system, by which electrical energy may be transmitted through a large air gap between coils without electrical connection. It presents theoretical and simulation analysis of IPT, which allows for supplying a receiver in the conditions of slow, in relation to the dynamics of power supply, changes in dimension of the air gap. The influence of frequency characteristics of the system on the possible selection...
-
Artificial Neural Network (ANN)-Based Voltage Stability Prediction of Test Microgrid Grid
Publikacja -
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublikacjaA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Voltage and Reactive Power Load Flow Optimization in the Power System Using Fuzzy Logic
PublikacjaThe paper presents issues related to voltage control in the power system. An original method of reactive power flow optimization is considered, which leads to improved voltages in the power system and reduced active power losses. The optimization method is based on a procedure that employs fuzzy logic and is supported by a gradient search algorithm. The method has been implemented in PLANS software and verified.
-
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables
PublikacjaThis work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC...
-
Hybridized Space-Vector Pulsewidth Modulation for Multiphase Two-Level Voltage Source Inverter
PublikacjaIn space vector pulsewidth modulation (SVPWM) algorithms for multiphase two-level voltage source inverters (VSI), the components of active vectors in all orthogonal spaces have to be calculated within the processor and stored in its memory. These necessitate intensive computational efforts of the processor and large memory space. This article presents a hybridized SVPWM for multiphase two-level VSI. In this algorithm, elements...
-
Electrical safety in low-voltage DC microgrids with B-type residual current devices
PublikacjaResidual current devices (RCDs) are most popular devices used in low-voltage installations for protection against electric shock and fire. In cases of high risk of electric shock the application of RCDs is mandatory. Currently, the spread of local direct current (DC) microgrids is widely considered. This creates new challenges for protective systems, in particular those based on RCDs. The main purpose of the research is to test...
-
Compensation of Voltage Drops in Trolleybus Supply System Using Battery-Based Buffer Station
PublikacjaThis paper analyzes the results of a trial operation of a battery-based buffer station supporting a selected section of trolleybus power supply systems in Pilsen, Czech Republic. The buffer station aims to prevent the catenary from excessive voltage drops in a part of the route that is most remote from the traction substation. Compensation of voltage drops is carried out by continuously measuring the catenary voltage and injecting...
-
New Alternative Passive Networks to Improve the Range Output Voltage Regulation of the PWM Inverters
PublikacjaThis paper presents different topologies of buck-boost converters with passive input networks that have alternative topologies; this is known in the literature as a Z-source inverter. Alternative passive networks were named by the authors as T-inverters; these improve output voltage regulation of the PWM inverters. T-inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage...
-
Design of Intelligent Low-Voltage Load Switch for Remote Control System in Smart Grid
PublikacjaCurrent low-voltage load switches do not support remote disconnect/connect and real-time monitoring of a disconnect/connect state. Addressing to these issues, this paper presents a low-voltage load switch for a smart remote control system, which uses a one-chip microcontroller board and a DC step motor drive mechanism and provides the feedback on the switch status also. Arrears disconnect and full-pay connect control is implemented...
-
Hydro Power Plant in the Process of Voltage Control in the Electric Power System and the System Restoration
PublikacjaThe article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage control during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublikacjaIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
Unidirectional DC/DC Converter with Voltage Inverter for Fast Charging of Electric Vehicle Batteries
PublikacjaThe paper proposes the adaptation of the industrial plant’s power network to supply electric vehicle (EV) fast-charging converters (above 300 kW) using renewable energy sources (RESs). A 600 V DC microgrid was used to supply energy from RESs for the needs of variable speed motor drives and charging of EV batteries. It has been shown that it is possible to support the supply of drive voltage frequency converters (VFCs) and charging...
-
Double-Headed Cationic Lipopeptides: An Emerging Class of Antimicrobials
Publikacja -
Myeloid-derived suppressor cells: a double-edged sword?
Publikacja -
Reactions of parylenes with double bonds: An ab initio study
Publikacja -
Simulation of the profile wear of the tool in double wheel lapping
PublikacjaPrzedstawiono założenia modelowe do wyznaczenia zużycia profilowego narzędzia w docieraniu dwutarczowym. Rozkłady istotnych czynników kinematycznych (prędkości docierania i przyspieszenia stycznego) wpływających na zużycie docieraka zaprezentowane zostały dla różnych typów zakreślanych trajektorii.
-
Numerical simulation of water drainage in double-porosity soils
PublikacjaArtykuł dotyczy modelowania przepływu wody w warunkach nienasyconych w gruntach o podwójnej porowatości, które są złożone z dwóch materiałów porowatych o bardzo różnych parametrach. przepływ w takich ośrodkach często charakteryzuje się powstawaniem lokalnych gradientów ciśnienia między obszarami dobrze isłaboprzepuszczalnymi.Przedstawiono matematyczny model przepływu wody w gruncie w strefie nienasyconej. Przepływ odbywa się w...
-
Simulation of the profile wear of the tool in double wheel lapping
PublikacjaW pracy przedstawiono model zużycia narzędzia w docieraniu dwutarczowym. Wyprowadzono równania opisujące kontakt przedmiotu z narzędziem. Przedstawiono wyniki analiz symulacyjnych dla różnych parametrów kinematycznych - dla układu współbieżnego i przeciwbieżnego.
-
Experimental tests of steel double-type balcony connections
PublikacjaThe paper presents analysis and results of experimental tests of full scale prefabricated balcony sets with dimensions (width × length × height): 2.0 m × 2.78 m × 0.186 m (in slope to 0.17 m). The sets consists of reinforced concrete slabs (balcony and ceiling) connected with each other by double-type balcony connections. The paper analyses the impact of variable parameters on the load carry capacity of elements. Additionally...
-
Double Bias of Mistakes: Essence, Consequences, and Measurement Method
PublikacjaThere is no learning without mistakes. However, there is a clash between‘positive attitudes and beliefs’regarding learning processes and the ‘negative attitudes and beliefs’towardthese being accompanied bymistakes. Thisclash exposesa cognitive bias towardmistakesthat might block personal and organizational learning. This study presents an advanced measurement method to assess thebias of mistakes. The essence of it is the...
-
Synthesis and properties of the double perovskites La2NiVO6, La2CoVO6, and La2CoTiO6
Publikacja -
Double-ridged horn antenna with sinusoidal ridge profile
PublikacjaPrzedstawiono wyniki symulacji numerycznej oraz pomiarów parametrów anteny tubowej z podwójnym grzbietem. Badania numeryczne dotyczyły zarówno samego układu zasilania falowodu grzbietowego jak i całej anteny z uwzględnieniem sinusoidalnego profilu impedancji grzbietu. Wyniki obliczeń dopasowania oraz charakterystyk promieniowania, wykonanych przy użyciu symulatora QW-3D, porównano z wynikami pomiarów, stwierdzając dobrą zgodność...
-
Structure and electric properties of double magnesium zirconium orthophosphate
PublikacjaPublikacja przedstawia wyniki pomiarów elektrycznych i strukturalnych ortofosforanu magnezowo-cyrkonowego.
-
Wear of the tool in double-disc lapping of silicon wafers
PublikacjaPrzedstawiono założenia modelowe do określania zużycia narzędzia w docieraniu krzemowych płytek półprzewodnikowych. Obliczenia zostały wykonane dla różnych parametrów kinematycznych, wpływających na zużycie narzędzia w określonych jego obszarach.
-
Double ZIF-L structures with exceptional CO2 capacity
PublikacjaCarbon dioxide emission is an emerging problem nowadays and new methods are designed for its control. In this article, a report on the formation of zeolitic imidazole framework with an apparent double leaf-like morphology DZIF-L is given. The special structure of the materials prevents from aggregation of the particles providing remarkable CO2 capacity. At 0.1 MPa the CO2 uptake was 2.99 ± 0.06 mmol/g. The capacity of synthesized...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Dane BadawczeThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Use of a Virtual Instrument for Measurements of Direct Voltages in the Presence of Interferences
Publikacja -
Low frequency nois of supecapacitor
Dane BadawczeDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Effects of solution composition and electrophoretic deposition voltage on various properties of nanohydroxyapatite coatings on the Ti13Zr13Nb alloy
PublikacjaThe purpose of the research was to establish the influence of the solution composition and the electrophoretic deposition voltage on the coating homogeneity and thickness, nanohardness, adhesion, corrosion resistance and wettability. The Ti13Zr13Nb alloy was coated by the electrophoretic technique with hydroxyapatite in a solution containing 0.1, 0.2 or 0.5 g nanoHAp in 100 mL of suspension and at voltage 15, 30 or 50 V. The scanning...
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublikacjaLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublikacjaThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.