Wyniki wyszukiwania dla: KATALOG
-
New potent STS inhibitors based on fluorinated 4-(1-phenyl-1H-[1,2,3]triazol-4-yl)-phenyl sulfamates
PublikacjaA series of fluorinated analogs based on the frameworks of 4-(1- phenyl-1H-[1,2,3]triazol-4-yl)-phenyl sulfamates have been synthesized as steroid sulfatase (STS) inhibitors. The design of chemical structures of new potential STS inhibitors was supported by molecular docking techniques to identify potential interactions between inhibitors and amino acid residues located in the STS active site. The STS inhibitory potency was evaluated...
-
Fixed Pattern Noise Reduction and Linearity Improvement in Time-Mode CMOS Image Sensors
PublikacjaIn the paper, a digital clock stopping technique for gain and offset correction in time-mode analog-to-digital converters (ADCs) has been proposed. The technique is dedicated to imagers with massively parallel image acquisition working in the time mode where compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. Fixed pattern noise (FPN) reduction has been experimentally validated...
-
Electrochemical impedance spectroscopy measurements - conductivity vs. temperature and conductivity vs. oxygen partial pressure - BaCe0.6Zr0.2Y0.1Tb0.1O3-δ
Dane BadawczeThe dataset consists of two main catalogs consisting of measurement data: of the electrical conductivity of the BaCe0.6Zr0.2Y0.1Tb0.1O3-δ (BCZYTb) sample as a function of temperature and of the electrical conductivity as a function of oxygen partial pressure (pO2). Measurements as a function of temperature were carried out in dry and wet air (pH2O ~...
-
Infrastruktura dla Pomorskich Tras Rowerowych R-10 i R-9 o znaczeniu międzynarodowym. Opis założeń projektowych
PublikacjaProjekt koncepcji zagospodarowania rowerowych miejsc postojowych powstał w ramach przedsięwzięcia strategicznego "Pomorskie Trasy Rowerowe o znaczeniu międzynarodowym R-10 i Wiślana Trasa Rowerowa (R-9)", którego inicjatorem i koordynatorem był Departament Turystyki i Promocji Urzędu Marszałkowskiego Województwa Pomorskiego. Założeniem przedsięwzięcia było wybudowanie dwóch oznakowanych tras rowerowych z dedykowana...
-
A current-controlled FET
PublikacjaA novel semiconductor device, viz., Horizontally-Split-Drain Current-Controlled Field-Effect Transistor (HSDCCFET) with two control electrodes is proposed in this works. For the sake of brevity, the device can be called a CCFET. Operating principle of the proposed transistor is based on one of the galvanomagnetic phenomena, the Biot-Savart-Laplace law and a Gradual Channel Detachment Effect (GCDE). The transistor is dedicated...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Dane BadawczeThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Stanowisko laboratoryjne do badania transmisji DMA oparte na procesorze SHARC.
PublikacjaReferat przedstawia stanowisko w Laboratorium ''Integracja Sprzętu i Oprogramowania'', zapoznające studentów z cechami transmisji DMA w wersji zbliżonejdo tej z komputera IBM XT. Stanowisko oparto na zestawie uruchomieniowym''EZ-KIT Lite'' z procesorem sygnałowym ADSP-21061 z rodziny SHARC firmy Analog Devices. Zastosowane algorytmy i rozwiązania mają charakter ogólny i mogą być realizowane w zbliżonej formie również na...
-
Inseparability criteria based on matrices of moments
PublikacjaInseparability criteria for continuous and discrete bipartite quantum states based on moments of annihilationand creation operators are studied by developing the idea of Shchukin-Vogel criterion Phys. Rev. Lett. 95,230502 2005. If a state is separable, then the corresponding matrix of moments is separable too. Thus, wederive generalized criteria based on the separability properties of the matrix of moments. In particular, acriterion...
-
Dead-Time Effect Compensation Based on Additional Phase Current Measurements
PublikacjaThis paper proposes a new method of dead-time effect compensation. The proposed solution is based on additional phase current measurements realized by analog-to-digital converters. These measurements are carried out at the time instants specified by a pulsewidth-modulation (PWM) strategy. This makes it possible to estimate inverter currents at the commutation instants and, finally, to estimate the voltage error caused by dead time. This...
-
Quantum security and theory of decoherence
PublikacjaWe sketch a relation between two crucial, yet independent, fields in quantum information research, viz. quantum decoherence and quantum cryptography. We investigate here how the standard cryptographic assumption of shielded laboratory, stating that data generated by a secure quantum device remain private unless explicitly published, is disturbed by the einselection mechanism of quantum Darwinism explaining the measurement process...
-
Analiza temperatury ekwiwalentnej do projektowania nawierzchni asfaltowych w Polsce z wykorzystaniem metody AASHTO 2004
PublikacjaW artykule przedstawiono analizę temperatury ekwiwalentnej obliczanej w oparciu o kryterium spękań zmęczeniowych warstw asfaltowych z metody AASHTO 2004 oraz kryterium deformacji strukturalnych Instytutu Asfaltowego. Do obliczeń przyjęto konstrukcję nawierzchni KR5 oraz wykorzystano dane temperaturowe z 50 stacji meteorologicznych z okresu 30 lat od roku 1989 do roku 2019 włącznie udostępnione przez Instytut Meteorologii i Gospodarki...
-
Binding of new cationic porphyrin–tetrapeptide conjugates to nucleoprotein complexes
Publikacja -
Analogue CMOS ASICs in Image Processing Systems
PublikacjaIn this paper a survey of analog application specific integrated circuits (ASICs) for low-level image processing, called vision chips, is presented. Due to the specific requirements, the vision chips are designed using different architectures best suited to their functions. The main types of the vision chip architectures and their properties are presented and characterized on selected examples of prototype integrated circuits (ICs)...
-
A 1-nS 1-V Sub-1-µW Linear CMOS OTA with Rail-to-Rail Input for Hz-Band Sensory Interfaces
PublikacjaThe paper presents an operational transconductance amplifier (OTA) with low transconductance (0.62–6.28 nS) and low power consumption (28–270 nW) for the low-frequency analog front-ends in biomedical sensor interfaces. The proposed OTA implements an innovative, highly linear voltage-to-current converter based on the channel-length-modulation effect, which can be rail-to-rail driven. At 1-V supply and 1-Vpp asymmetrical input driving,...
-
A Power-Efficient Digital Technique for Gain and Offset Correction in Slope ADCs
PublikacjaIn this brief, a power-efficient digital technique for gain and offset correction in slope analog-to-digital converters (ADCs) has been proposed. The technique is especially useful for imaging arrays with massively parallel image acquisition where simultaneous compensation of dark signal non-uniformity (DSNU) as well as photo-response non-uniformity (PRNU) is critical. The presented approach is based on stopping the ADC clock by...
-
Chloroacridine derivatives as potential anticancer agents which may act as tricarboxylic acid cycle enzyme inhibitors
PublikacjaThe chloroacridines affect biological forms of melanoma in different ways. Amelanotic (Ab) melanoma (with inhibited melanogenesis and higher malignancy) was particularly sensitive to the action of the chloroacridines. The Ab melanoma cells died through apoptosis and through death without caspase activation. Diminished activity of TAC enzymes was noticed among Ab melanoma cells together with ATP/NAD depletion, especially in the...
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublikacjaA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
Ocena przydatności komercyjnych elektrod otulonych do spawania mokrego pod wodą z wykorzystaniem analizy skupień
PublikacjaNajbardziej uniwersalną i ekonomiczną metodą remontów konstrukcji eksploatowanych pod wodą jest spawanie mokre elektrodami otulonymi. Ze względu na bardzo dobrą operatywność i stabilność jarzenia się łuku w środowisku wodnym stosuje się elektrody o otulinie rutylowej. Na rynku dostępnych jest kilka gatunków elektrod dedykowanych do prac podwodnych, których cena jest znacznie wyższa niż elektrod komercyjnych. Celem pracy było statystyczne...
-
KLASYFIKACJA EMOCJI W MUZYCE FILMOWEJ Z WYKORZYSTANIEM TESTÓW SUBIEKTYWNYCH
PublikacjaCelem referatu było przedstawienie testów odsłuchowych, w których zadaniem osób ankietowanych było przypisanie danego fragmentu muzycznego do odpowiedniej klasy emocji. Kolejne kroki eksperymentu obejmowały wybór muzyki filmowej do testów (baza Epidemic Sound), przygotowanie założeń ankiety oraz modelu emocji wykorzystywanych w testach odsłuchowych, jak również konstrukcj ˛e ankiety. Ankieta została zrealizowana za pomoc ˛a formularzy...
-
Acoustic emission studies of the 7075 aluminium alloy pitting corrosion process
Dane BadawczeThe dataset contains the cyclic polarization studies and corresponding acoustic emission measurements, revealing the pitting corrosion process of the passive layer at the surface of the 7075 aluminum alloy in the borate buffer with different chloride ions concentrations, in the range between 0.05 and 25 mM.
-
ECG measurement in the bathtub - getting into the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Wpływ stosowania usług Inteligentnych Systemów Transportowych na poziom bezpieczeństwa ruchu drogowego
PublikacjaW artykule opisano założenia projektu pt. "Wpływ stosowania usług Inteligentnych Systemów Transportowych na poziom bezpieczeństwa ruchu drogowego". Projekt jest realizowany w ramach programu Rozwój Innowacji Drogowych (RID) zorganizowanego i finansowanego przez Narodowe Centrum Badań i Rozwoju i Generalną Dyrekcję Dróg Krajowych i Autostrad (umowa nr DZP/RID-I-41/7/NCBR/2016). Celem projektu jest opracowanie narzędzi , które umożliwią...
-
Determination of Vehicles Load Equivalency Factors for Polish Catalogue of Typical Flexible and Semi-rigid Pavement Structures
PublikacjaThe new Polish Catalog of Typical Flexible and Semi-rigid Pavement Structures was introduced to use in practice in 2014. Much of works were focused on actualization of vehicles load equivalency factors. For this purpose data delivered from weigh-inmotion were analyzed. Four methods of determination of load equivalency factors for pavement structure design were compared. The analysis showed that fourth power equation, AASHTO 1993...
-
Zasada szalonego patchworku – efektuacja jako inspiracja do kształtowania relacji i postaw biznesowych
PublikacjaJedna zzasad efektuacyjnego podejscia do przedsiebiorczosci jest zasada szalonego patchworku (crazy quilt), która dotyczy budowania relacji z otoczeniem biznesowym. Zgodnie z nia przedsiebiorca powinien korzystac zkontaktów zosobami zotoczenia, zbudowanych jeszcze przed załozeniem firmy, atakze aktywnie kształtowac nowe relacje wsrodowisku, wktórym firma działa. Silny networking iznajomosc wielu osób pozwalaja na czerpanie inspiracji...
-
Frequency and time domain characteristics of digital control of electric vehicle in-wheel drives
PublikacjaIn-wheel electric drives are promising as actuators in active safety systems of electric and hybrid vehicles. This new function requires dedicated control algorithms, making it essential to deliver models that reflect better the wheel-torque control dynamics of electric drives. The timing of digital control events, whose importance is stressed in current research, still lacks an analytical description allowing for modeling its...
-
Integration of Multi-Source Geospatial Data from GNSS Receivers, Terrestrial Laser Scanners, and Unmanned Aerial Vehicles
PublikacjaThe analysis based on geospatial data from different measurement systems now constitutes a complex numerical and practical enterprise. The dynamic development of modern technologies enables rapid and precise acquisition of such data. Nonetheless, the diversity of reference systems is today one of the main challenges for their correct interpretation. The combined use of the processed measurement results and archival data in paper...
-
Audio Content and Crowdsourcing: A Subjective Quality Evaluation of Radio Programs Streamed Online
PublikacjaRadio broadcasting has been present in our lives for over 100 years. The transmission of speech and music signals accompanies us from an early age. Broadcasts provide the latest information from home and abroad. They also shape musical tastes and allow many artists to share their creativity. Modern distribution involves transmission over a number of terrestrial systems. The most popular are analog FM (Frequency Modulation) and...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on one side- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl behind the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at buttocks, strengthening 2x smaller, drl at buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drl at the feet - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - one side of the bathtub is grounded, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, sitting motionless - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the knees, signal amplification x2 - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub at the buttocks, drills at the feet, grounding the bathtub - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, placed on the back - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on the measuring electrodes, drl outside the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on the outside of the bathtub on both sides, measuring electrodes on the front and back of the bathtub- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the water, measuring electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath mass on the other - the person is moving- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in water, front and back measuring electrodes - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes on the sides of the bathtub, bath simulation - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - sitting on measuring electrodes, drl in water - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the buttocks - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - conversation during measurement, electrodes on the sides of the bathtub, drl in water - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl in the bathtub, electrodes on the sides of the bathtub - men
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - electrodes at the feet, drl at the knees - women
Dane BadawczeThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...