Filters
total: 908
filtered: 720
-
Catalog
Chosen catalog filters
Search results for: FABRY–PEROT SENSOR
-
Fluctuation-enhanced scent sensing using a single gas sensor
PublicationScent or aroma sensing during aromatherapy can be carried out by applying only a single resistance gas sensor (TGS - Taguchi Gas Sensors). This paper considers the efficiency of detection of essential oils by DC resistance and its fluctuations observed in TGS sensors. A detailed study has been conducted for scents emitted by five popular essential oils using three sensor types (TGS 2600, TGS 2602, TGS 823). The research was focused...
-
Enhancing Performance of Switched Parasitic Antenna for Localization in Wireless Sensor Networks
PublicationThis paper presents an Electronically Steerable Parasitic Array Radiator (ESPAR) antenna with enhanced performance of estimating the incoming signal direction. Designed antenna is dedicated for 2.4 GHz ISM applications with emphasis on Wireless Sensor Networks (WSN). The limitations of the existing design approach are illustrated, as well as perspectives and challenges of the proposed solution in relation to the localization in...
-
Planar Microwave Bragg Reflector Resonant Dielectric Sensor
PublicationIn this paper, a periodic structure is used to design a microwave Bragg reflector with the help of hexagonal lattice, which provides a 5 GHz wide stopband between the low-pass band with cut-off frequency 2.6 GHz and the bandpass response with start and stop frequency 7.8 GHz and 10.5 GHz, respectively. A defect in lattice allows passing a narrowband signal at 6 GHz which is found, from the dispersion relation, to be in the region...
-
Enhanced Eye-Tracking Data: a Dual Sensor System for Smart Glasses Applications
PublicationA technique for the acquisition of an increased number of pupil positions, using a combined sensor consisting of a low-rate camera and a high-rate optical sensor, is presented in this paper. The additional data are provided by the optical movement-detection sensor mounted in close proximity to the eyeball. This proposed solution enables a significant increase in the number of registered fixation points and saccades and can be used...
-
A Compact and Lightweight Microwave Tilt Sensor Based on an SRR-Loaded Microstrip Line
PublicationIn this paper, the symmetry property of split ring resonators (SRRs) is exploited to develop a tilt sensor. The sensor is composed of an SRR-loaded microstrip line operating at microwave frequencies. It is shown that the depth of notch in the reflection characteristic of the microstrip is a function of the tilt angle of the SRR. Thus, it can be used for sensing inclination. The sensor benefits from very compact size and light weight....
-
Estimation of the amplitude of the signal for the active optical gesture sensor with sparse detectors
PublicationIn this paper we deal with the problem of precise gesture recognition for the active optical proximity sensor with sparse 8 photodiodes. We particularly focus on developing the method of estimating the real, usually not observable, maximum signal value representing maximum intensity of light reflected from an obstacle present in the front of the sensor. Different configurations of the fingers were used as an obstacle. The Monte Carlo...
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublicationIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
Determination of chlorine concentration using single temperature modulated semiconductor gas sensor
PublicationA periodic temperature modulation using sinusoidal heater voltage was applied to a commercial SnO2 semiconductor gas sensor. Resulting resistance response of the sensor was analyzed using a feature extraction method based on Fast Fourier Transformation (FFT). The amplitudes of the higher harmonics of the FFT from the dynamic nonlinear responses of measured gas were further utilized as an input for Artificial Neural...
-
Determination of the Vehicles Speed Using Acoustic Vector Sensor
PublicationThe method for determining the speed of vehicles using acoustic vector sensor and sound intensity measurement technique was presented in the paper. First, the theoretical basis of the proposed method was explained. Next, the details of the developed algorithm of sound intensity processing both in time domain and in frequency domain were described. Optimization process of the method was also presented. Finally, the proposed measurement...
-
Eventual Convergence of the Reputation-Based Algorithm in IoT Sensor Networks
PublicationUncertainty in dense heterogeneous IoT sensor networks can be decreased by applying reputation-inspired algorithms, such as the EWMA (Exponentially Weighted Moving Average) algorithm, which is widely used in social networks. Despite its popularity, the eventual convergence of this algorithm for the purpose of IoT networks has not been widely studied, and results of simulations are often taken in lieu of the more rigorous proof....
-
Investigation of Taste Substances by five Channel Lipid-Polymer Membrane Sensor.
PublicationBadano substancje o różnych stężeniach należące do czterech klas smaku za pomocą pięcio-kanałowego sensora opartego o elektrody jonoselektywne z różnymi membranami polimerowo-lipidowymi. Stwierdzono, że sensor jest czuły na zmiany stężeń chlorowodorku chininy, kawsu cytrynowego i chlorku sodu, przeciwnie jak w przypadku sacharozy. Na podstawie tych wyników można przypuszczać, że sensor może być zastosowany do roztworów składających...
-
Suppression of distortions in signals received from Doppler sensor for vehicle speed measurement
PublicationDoppler sensors are commonly used for movement detection and speed measurement. However, electromagnetic interference and imperfections in sensor construction result in degradation of the signal to noise ratio. As a result, detection of signals reflected from moving objects becomes problematic. The paper proposes an algorithm for reduction of distortions and noise in the signal received from a simple, dual-channel type of a Doppler...
-
A Microwave Sensor with Operating Band Selection to Detect Rotation and Proximity in the Rapid Prototyping Industry
PublicationThis paper presents a novel sensor for detecting and measuring angular rotation and proximity, intended for rapid prototyping machines. The sensor is based on a complementary split-ring resonator (CSRR) driven by a conductor-backed coplanar waveguide. The sensor has a planar topology, which makes it simple and cost-effective to produce and accurate in measuring both physical quantities. The sensor has two components, a rotor, and...
-
Localization in wireless sensor networks using switched parasitic antennas
PublicationA switched parasitic monopole antenna for 2.4 GHz ISM applications is design and investigated in this paper. One of the most promising applications for such switched-beam antennas is localization in wireless sensor networks (WSN). It is demonstrated that the use of this antenna improves accuracy of localization algorithms and allows for reduction of the number of reference nodes in localization system.
-
Sandwich Biobattery with Enzymatic Cathode and Zinc Anode Integrated with Sensor
PublicationCarbon paper covered with side-naphthylated multi walled carbon nanotubes was used as the conducting support for the construction of a biocathode in a hybrid biofuel cell. Laccase Carrena unicolor enzyme was employed as the catalyst for the 4e reduction of oxygen and a zinc disc covered with hopeite was used as the anode. Derivatized carbon nanotubes increase the working surface of the electrode and provide direct contact with...
-
Microscale diamond protection for a ZnO coated fiber optic sensor
PublicationFiber optic sensors are widely used in environmental, biological and chemical sensing. Due to the demanding environmental conditions in which they can be used, there is a risk of damaging the sensor measurement head placed in the measuring field. Sensors using nanolayers deposited upon the fiber structure are particularly vulnerable to damage. A thin film placed on the surface of the fiber end-face can be prone to mechanical damage...
-
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
Pose classification in the gesture recognition using the linear optical sensor
PublicationGesture sensors for mobile devices, which have a capability of distinguishing hand poses, require efficient and accurate classifiers in order to recognize gestures based on the sequences of primitives. Two methods of poses recognition for the optical linear sensor were proposed and validated. The Gaussian distribution fitting and Artificial Neural Network based methods represent two kinds of classification approaches. Three types...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
A novel concept for tissue-metal detection and differentiation using an inductive proximity sensor
PublicationIn this paper a novel application of inductive proximity sensors for detection of living tissue by means of measurements of the coil impedance changes at different frequencies is described. The mathematical analyses utilizing Bessel function estimation include detected object size and its distance from a sensor. The main aim of this study is to prove the possibility of distinguishing between metal objects and living tissues. The...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
Noise spectral density computation based on finite element model of piezoceramic sensor
PublicationThe high sensitivity with wide bandwidth is required for sensor applications in non-destructive testing (NDT). The sensitivity of piezoceramic sensors demands to minimize their noise especially thermal noise, polarisation noise and low frequency 1/f noise,which are the main sources of voltage or current fluctuation in this sort of sensors. For simplicity, only the piezoceramic part of sensor was under study. the theoretical and...
-
Sensor Position Estimation Method for IoT Using Mobile Reference Node
PublicationThe paper proposes an innovative method of locating objects for the Internet of Things (IoT). The proposed method allows the position of a fixed measuring sensor (MS) to be estimated using one mobile base station with a known position moving around the MS. The mathematical analysis of the method, and three algorithms — Newton’s (NA), gradient descent (GD) and genetic (GA) — for solving the system of non-linear positional equations...
-
Determination of vertical displacements by using the hydrostatic levelling systems with the variable location of the reference sensor,
PublicationAbstract: In this paper, the author proposed a new method for determination of vertical displacements with the use of hydrostatic levelling systems. The traditional method of hydrostatic levelling uses a rule in which a position of reference sensor is stable. This assumption was not adapted in the proposed method. Regarding the issue mentioned above, the reference sensor is treated in the same way as the others sensors that measure...
-
Gesture Recognition With the Linear Optical Sensor and Recurrent Neural Networks
PublicationIn this paper, the optical linear sensor, a representative of low-resolution sensors, was investigated in the multiclass recognition of near-field hand gestures. The recurrent neural network (RNN) with a gated recurrent unit (GRU) memory cell was utilized as a gestures classifier. A set of 27 gestures was collected from a group of volunteers. The 27 000 sequences obtained were divided into training, validation, and test subsets....
-
Photonic sensor to detect rapid changes in CRP levels
PublicationOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...
-
Detection of Water on Road Surface with Acoustic Vector Sensor
PublicationThis paper presents a new approach to detecting the presence of water on a road surface, employing an acoustic vector sensor. The proposed method is based on sound intensity analysis in the frequency domain. Acoustic events, representing road vehicles, are detected in the sound intensity signals. The direction of the incoming sound is calculated for the individual spectral components of the intensity signal, and the components...
-
Support for Employees with ASD in the Workplace Using a Bluetooth Skin Resistance Sensor–A Preliminary Study
PublicationThe application of a Bluetooth skin resistance sensor in assisting people with Autism Spectrum Disorders (ASD), in their day-to-day work, is presented in this paper. The design and construction of the device are discussed. The authors have considered the best placement of the sensor, on the body, to gain the most accurate readings of user stress levels, under various conditions. Trial tests were performed on a group of sixteen...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublicationA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
an intelligent image processing sensor - the algorithm and the hardware implementation
PublicationW artykule przedstawiono algorytm przeznaczony do rozpoznawania obiektów ruchomych w obrazie do celu analizy ruchu pojazdów. Algorytm został zrealizowany w układzie FPGA.Ang.: This paper describes the idea and theimplementation of the robust algorithm dedicated toextraction of moving vehicles from real-time cameraimages for the evaluation of traffic parameters, suchas the number of vehicles, their direction of movementand their...
-
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Data fusion of sparse, heterogeneous, and mobile sensor devices using adaptive distance attention
PublicationIn environmental science, where information from sensor devices are sparse, data fusion for mapping purposes is often based on geostatistical approaches. We propose a methodology called adaptive distance attention that enables us to fuse sparse, heterogeneous, and mobile sensor devices and predict values at locations with no previous measurement. The approach allows for automatically weighting the measurements according to a priori...
-
Influence of sensor design and optical properties of tissue on the photoplethysmographic signal
PublicationPhotopletysmography and an associated technique called pulse oximetry are still explored due to the expectations that they give a lot of information about the state of the patient and, also, due to the fact that they are non invasive. Knowledge about the impact of various parameters on the measured signal leads to a faster and a more reliable way of analyzing measurement results and finding the dependencies between the involved...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublicationMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Application of Multiplicative Drift Correction and Component Correction methods on simulated gas sensor array responses
PublicationSensor response drift is one of the most challenging problems in gas-analyzing systems. Such systems, commonly called electronic noses, are expected to be reliable and reproducible in the long term. Due to the drift phenomena, electronic noses usability is limited to the relatively short period of time, and frequent recalibrations of device are required. Because it is very hard to fabricate sensors without drift, this phenomenon...
-
Design and Experimental Validation of a Metamaterial-Based Sensor for Microwave Imaging in Breast, Lung, and Brain Cancer Detection
PublicationThis study proposes an innovative geometry of a microstrip sensor for high-resolution microwave imaging (MWI). The main intended application of the sensor is early detection of breast, lung, and brain cancer. The proposed design consists of a microstrip patch antenna fed by a coplanar waveguide with a metamaterial layer-based lens implemented on the back side, and an artificial magnetic conductor (AMC) realized on as a separate...
-
Determination of toxic gases based on the responses of a single electrocatalytic sensor and pattern recognition techniques
PublicationA response from an electrocatalytic gas sensor contains fingerprint information about the type of gas and its concentration. As a result, a single gas sensor can be used for the determination of different gases. However, information about the type of gas and its concentration is hidden in the unique shape of the current–voltage response and it is quite difficult to explore. One of the ways to get precise information about the measured...
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublicationThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Scene Segmentation Basing on Color and Depth Images for Kinect Sensor
PublicationIn this paper we propose a method for segmenting single images from Kinect sensor by considering both color and depth information. The algorithm is based on a series of edge detection procedures designed for particular features of the scene objects. RGB and HSV color planes are separately analyzed in the first step with Canny edge detector, resulting in overall color edges mask. In depth images both clear boundaries and smooth...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublicationThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Multiple sound sources localization in free field using acoustic vector sensor
PublicationMethod and preliminary results of multiple sound sources localization in free field using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...
-
Multiple sound sources localization in real time using acoustic vector sensor
PublicationMethod and preliminary results of multiple sound sources localization in real time using the acoustic vector sensor were presented in this study. Direction of arrival (DOA) for considered source was determined based on sound intensity method supported by Fourier analysis. Obtained spectrum components for considered signal allowed to determine the DOA value for the particular frequency independently. The accuracy of the developed...