Filters
total: 3322
filtered: 2477
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: VOLTAGE CONTROL, REACTIVE POWER CONTROL, LARGE CUSTOMER
-
Automation of ship and control
PublicationSummaryThe article presents the problem of automation of ship and control. This paper will discuss the basic tasks of the track ship control, collision avoidance and automatic dynamic positioning. The following subjects will be presented: the general structure of the ship's control, methods and control algorithms for the above mentioned tasks..StreszczenieArtykuł przedstawia zagadnienia automatyzacji i sterowania statkiem. W pracy...
-
Supervisory Control System for Adaptive Phase and Work Cycle Management of Sequencing Wastewater Treatment Plant
PublicationThe paper presents the design of the integrated control system applied to Sequencing Batch Reactor (SBR) in a biological Wastewater Treatment Plant (WWTP) in Swarzewo, which operates under activated sludge technology. Based on the real data records, ASM2d biological processes model and aeration system model, hierarchical control system for dissolved oxygen tracking and cycle management is designed. Internal Model Controller (IMC)...
-
Damage Control in Warships
PublicationAs a result of dynamic quantitative and qualitative developments in the maritime industry its participants face harder and harder challenges pertaining to safety of ships and navigation. Practice has shown that even very well organised fleets are harassed by emergencies and accidents that can be neither predicted nor absolutely avoided. In order to counter the occuring emergencies and accidents, and to minimize their effects damage...
-
The multiscalar control of induction motor with the sliding mode controllers
PublicationThe control structure of induction motor is proposed in this paper. The structure of multiscalar control with conventional PI - controllers is well known in literature. The sliding mode multiscalar control (SMMC) conception is presented in this paper. The induction motor is fed by voltage source inverter. Comparison between two multiscalar control method is showed.
-
Simple stable discrete-time generalised predictive control with anticipated filtration of control error
PublicationPraca dotyczy uogólnionego sterowania predykcyjnego w czasie dyskretnym z antypacyjną filtracją błędu sterowania. Pokazano, iż przy spełnieniu pewnych warunków rozwiązanie problemu syntezy optymlanego regulatora predykcyjnego zawsze istnieje oraz prowadzi do stabilnego zamkniętego układu sterowania o określonych własnościach dynamicznych. W pracy rozważano także problem syntezy regulatora predykcyjnego dla modeli sterowania obiektów...
-
Decentralized control of a different rated parallel UPS systems
PublicationThe paper presents the single phase uninterruptible power supply (UPS) system with galvanic separated DC-AC-DC-AC converters operating in parallel. The CAN physical layer based system of communication between converters has been developed and applied, which allow to utilize a decentralized master-slave control providing high availability factor of the whole UPS system. The control system of particular converters has been developed...
-
Event-Triggered Communication in Cooperative, Adaptive Model Predictive Control of a Nuclear Power Plant’s Turbo–Generator Set
PublicationThis paper discusses the issue of optimizing the communication between the components of a cooperating control system formed by a pair of MPC controllers of a nuclear power plant turbine set using online recursive least squares identification. It is proposed to use event-triggered communication, i.e., sending information only at selected time instants, as opposed to the standard approach where communication is triggered by time...
-
Modern control strategy of bidirectional DAB converter with consideration of control nonlinearity
PublicationThis paper focuses on the control strategy for modern universal bidirectional Dual Active Bridge (DAB) converters for microgrid systems. An analysis of the converter equations was carried out, and typical problems related to the influence of dead time on the system operation were discussed. A closed control loop was developed, then tested by simulation and on a laboratory stand.
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublicationA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Design of synchronous generator two inputs regulator based on hinf control theory.
PublicationThe power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...
-
Integrated Control in High-Speed Networks Using Constrained Model Predictive Control
PublicationThis paper studies congestion control in high-speed communication networks using Model Predictive Control (MPC). Network traffic is assumed to consist of best-effort and priority traffic sources. An integrated controller consisting of two control parts is designed. The controller calculates the capacity for priority sources and the input rate of best-effort sources. MPC is desirable as it can take into account the constraints on...
-
Control of a vapour microturbine set in cogeneration applications
PublicationSystems with microturbines are implemented for local generation of heat and electricity. This paper presents the analysis of control concepts for a vapour microturbine set with a generator with permanent magnets, intended to work in small heat and power plants. Control system variants differed by the selection of controlled signals and set parameters. Possible ways of control were discussed and compared with experimentally determined...
-
Control system for contactless electrical energy transfer with varying air gap
PublicationInductive power transfer (IPT) is a system by which electrical energy may be transmitted without electrical connection through a large air gap between coils. Systems usually considered in the literature are the ones with a constant air gap. The paper describes the analysis of IPT, which allows for supplying an electrical load in the conditions of slow, in relation to the dynamics of power supply, changes in the dimensions of the...
-
Control of voltage source inverter without dead-time effects.
PublicationW artykule zaproponowano metodę dokładnego generowania wektora napięcia o małej amplitudzie w falowniku napięcia. Zaprezentowano metodę modulacji szerokości impulsów, w której wyeliminowano koniecznosć wprowadzania czasów martwych oraz kompensacji ich wpływu na napięcie wyjsciowe przekształtnika
-
Specificity of automatic control of micro-turbines (steam or gas -driven and expanders) in dispersed generation system of heat and electric power
PublicationThis paper presents specific problems of automatic control of steam micro-turbines and expanders intended for the dispersed, combined generating of heat and electric power. The investigations concern ensurance of certainty of energy supply and its required quality.
-
An optimized dissolved oxygen concentration control in SBR with the use of adaptive and predictive control schemes
PublicationThis paper addresses the problem of optimizing control of the aeration process in a water resource recovery facility (WRRF) using sequencing batch reactor (SBR), one that affects the efficiency of wastewater treatment by stimulating metabolic reactions of microorganisms through dissolved oxygen (DO) level control, and accounts for the predominant part of operating costs. Two independent approaches to DO control algorithm design...
-
MPPT and GMPPT Implementation for Buck-Boost Mode Control of quasi-Z-Source Inverter
PublicationThe focus is on the maximum power point tracking implementation for the buck-boost voltage mode control of a single-phase multilevel inverter based on a three-level neutral point clamped quasi-Z-source topology. To utilize shoot-through states only when boost function is needed and avoid it in the buck mode, two different control approaches are required. This work proposes merged control system which provides switching between...
-
Modelling and Control of a Brushless Multiphase Doubly-Fed Induction Generator in a Stand-Alone Wind Generation System
PublicationThe development of the novel multiphase brushless doubly-fed generator system and voltage controller for stand-alone mode configuration is proposed in this paper. The generator system is based on the new machine construction with multiphase control winding and traditional three-phase power winding. The dynamic model of multiphase brushless doubly-fed generator is presented, and the control strategy for voltage amplitude and frequency...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Robust identification of quadrocopter model for control purposes
PublicationThe paper addresses a problem of quadrotor unmanned aerial vehicle (so-called X4-flyer or quadrocopter) utility model identification for control design purposes. To that goal the quadrotor model is assumed to be composed of two abstracted subsystems, namely a rigid body (plant) and four motors equipped with blades (actuators). The model of the former is acquired based on a well-established dynamic equations of motion while the...
-
Neural Modelling of Steam Turbine Control Stage
PublicationThe paper describes possibility of steam turbine control stage neural model creation. It is of great importance because wider application of green energy causes severe conditions for control of energy generation systems operation Results of chosen steam turbine of 200 MW power measurements are applied as an example showing way of neural model creation. They serve as training and testing data of such neural model. Relatively simple...
-
Hybrid Approach to Networked Control System
PublicationEffcient control of Networked Control System (NCS) is a challenge, as the control methods need to deal with non-deterministic variable delays and data loss. This paper presents a novel hybrid approach to NCS where Model Predictive Control (MPC) is applied as a main controller and implicit switching MPC is used for data transmission control in event-driven shared communication medium, leading to complex control system with active...
-
Supervised model predictive control of wastewater treatment plant
PublicationAn optimizing control of a wastewater treatment plant (WWTP), allowing for cost savings over long time period and fulfilling effluent discharge limits at the same time, requires application of advanced control techniques. Model Predictive Control (MPC) is a very suitable control technology for a synthesis of such a truly multivariable controller that can handle constraints and accommodate model-based knowledge combined with hard...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Broken rotor symptoms in the sensorless control of induction machine
PublicationThe purpose of this paper is to investigate the need for a universal method for sensorless controlled induction motor drive diagnosis. The increasing number of sensorless control systems in industrial applications require a universal method for the drive diagnosis, which provides reliable diagnostic reasoning independent of control system structure and state variables measurement or estimation method.Simulations and experimental...
-
The control software of the portable raman spectrometer
PublicationThe paper contains a description of the control software of a portable Raman spectrometer which was built in the Department of Optoelectronics and Electronic Systems Faculty of Electronics, Telecommunications and Informatics Gdansk University of Technology. The software has modular structure, which includes the laser control module and the spectrum acquisition module (laser power selection, working mode and data acquisition time)...
-
THE INFLUENCE OF PHASE SHIFTERS ON THE VOLTAGE STABILITY OF CONNECTED POWER SYSTEMS
PublicationThe paper presents the results of simulation tests of connected power systems in which phase shifters were installed on cross-border links. The analysis was carried out in terms of assessing the impact of shifters on node voltage stability. Individual systems were characterized by different balance of active power: deficit or excess. The evaluation of voltage stability was based on the dU/dQ and dU/dP criteria.
-
Advanced Ship Control Methods
PublicationThe chapter presents two main streams of research in vessel control at sea: dynamic positioning (DP) of the vessel and decision support in case of collision at sea. The control structure and basic requirements for the DP system are defined. Selected issues of automatic control of a dynamically positioned vessel are discussed. A review of advanced methods of controlling a DP ship is carried out, taking into account the tasks of...
-
Genetic Hybrid Predictive Controller for Optimized Dissolved-Oxygen Tracking at Lower Control Level
PublicationA hierarchical two-level controller for dissolvedoxygenreference trajectory tracking in activated sludge processeshas been recently developed and successfully validated on a realwastewater treatment plant. The upper level control unit generatestrajectories of the desired airflows to be delivered by theaeration system to the aerobic zones of the biological reactor. Anonlinear model predictive control algorithm is applied to designthis...
-
Multiregional PI control strategy for dissolved oxygen and aeration system control at biological wastewater treatment plant
PublicationThe dissolved oxygen is a key parameter for biological processes at wastewater treatment plant. The dissolved oxygen tracking problem is one of the most complex and fundamental issue of biological processes. The paper proposes a new multiregional control strategy for dissolved oxygen tracking problem. The aeration system is included in overall control structure. The control mechanism within the operating point area is based on...
-
Recurrent Neural Network Based Adaptive Variable-Order Fractional PID Controller for Small Modular Reactor Thermal Power Control
PublicationThis paper presents the synthesis of an adaptive PID type controller in which the variable-order fractional operators are used. Due to the implementation difficulties of fractional order operators, both with a fixed and variable order, on digital control platforms caused by the requirement of infinite memory resources, the fractional operators that are part of the discussed controller were approximated by recurrent neural networks...
-
Design of synchronous generator voltage regulator based on H control theory
PublicationSystemy dużej mocy są z reguły systemami o dużej nieliniowości. Wynika to z dynamiki takiego obiektu jak również jego konfiguracji itd. Istnieje wiele metod umożliwiających sterowanie czy testowanie zaprojektowanych generatorów. W artykule analizowana jest metoda projektowania regulatora napięcia w oparciu o H. Wyniki symulacji są zadowalające, ponieważ tak zaprojektowany regulator lepiej tłumi kołysania elektromechaniczne niż...
-
Feedback control of water quality
PublicationSformułowano problem sterowania jakością wody w sieciach wodociągowych i następnie zaproponowano podejście do projektowania sterowania stężeniem chloru w takich sieciach, bazujący na estymacji parametrów oraz sterowaniu adaptacyjnym. Podejście wykorzystuje założenie, że w sieci wodociągowej istnieją punkty wstrzykiwania chloru. Zależność typu wejście-wyjście pomiędzy stężeniem chloru w węźle dozowania i monitorowania jest modelowana...
-
Predictive control system of the shunt active power filter
Publication -
New control system of the shunt active power filter
Publication -
The assessment of exploitation process of power for access control system
Publication -
Optimal linear control theory in power system application
PublicationPrzedstawiono syntezę stabilizatora systemowego przy wykorzystaniu metodyki Hinf. Zaprojektowany regulator umożliwia uzyskanie lepszych rezultatów w porównaniu z regulatorem odniesienia w szerokim zakresie zmian punktu pracy.
-
VIBRATION SURVEILLANCE DURING MILLING OF FLEXIBLE DETAILS WITH A USE OF THE ACTIVE OPTIMAL CONTROL
PublicationThe main goal of modern machining operations is to achieve increasingly better performance. High Speed Machining and/or High Performance Cutting, despite a lot of advantages, have also some drawbacks, for example, a possibility of losing stability and development of self-excited chatter vibration. This paper presents an approach of vibration surveillance during high speed milling with a use of active optimal control. Non-stationary...
-
Sensorless Control of Polyphase Induction Machines
PublicationThe basics of transformations of polyphase systems into orthogonal systems are explained. Vector models of induction machines in orthogonal planes are analysed and multiscalar models for rotor flux and main flux together with stator current are presented. A speed observer based on an extended model of the induction machine for selected variables is applied in the control system for the induction machine. On the basis of the model...
-
Graphical presentation of the power of energy losses and power developed in the elements hydrostatic drive and control system. Part II. Rotational hydraulic motor speed parallel throtling control and volumetric control systems
PublicationPrzedstawiono interpretację graficzną mocy strat energetycznych występujących w elementach układów napędu i sterowania hydrostatycznego, a także mocy rozwijanych przez te elementy. Dokonano analizy układu indywidualnego ze sterowaniem dławieniowym równoległym prędkości silnika hydraulicznego obrotowego, układu indywidualnego ze sterowaniem objętościowym, pompą o zmiennej wydajności, prędkości silnika hydrailicznego obrotowego,...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Flock behavior and control
PublicationIn this paper we present the results of the Flock Behaviour and Control workshop cluster during “Shapes of Logic Conference 2015”. During the event, students got familiar with the techniques of both visual and sound real-time data processing. The second topic presented for students was behaviourbased approach of design process, mainly based on the mathematical rules set up by Craig Raynolds on the swarm behaviour. The aim of the...
-
Control strategy for the multilevel cascaded H-bridge converter
PublicationThe paper presents the control strategy for Cascaded H-bridge (CHB) converter . The converter output voltage using Space-Vector Pulse Width Modulation (SV-PWM) strategy is controlled. The DC-link voltages are controlled by appropriate choice of H-Bridges and appropriate choice of active and passive vectors.
-
Designing control strategies of aeration system in biological WWTP
PublicationThe paper presents the complete design processes of a novel aeration control systems in the SBR (Sequencing Batch Reactor) wastewater treatment plant (WWTP). Due to large energy expense and high influence on biological processes, the aeration system plays a key role in WWTP operation. The paper considers the aeration system for a biological WWTP located in the northeast of Poland. This system consists of blowers, the main collector...
-
The adaptive backstepping control of PMSM supplied by current source inverter for the field weakening region
PublicationThe sensorless control system of permanent magnet synchronous motor PMSM supplied by current source inverter for field weakening operation is presented in this paper. The adaptive backstepping control system and the backstepping speed observer are presented. The control system is based on multi-scalar variables. The control variables are: dc-link voltage and the output current vector pulsation. The control system was named voltage...
-
Nonlinear fuzzy control of the dissolved oxygen in activated sludge processes
PublicationWastewater treatment plant is generally a complex, multivariable, time varying and nonlinear large scale industrial system. Moreover, interactions between the components are very strong. The dissolved oxygen tracking problem is one of the most complex and fundamental issues of biological processes. Air for the aerated tanks is supplied by aeration system (blowers, pipes, diffusers). It is a complex dynamic system. The new control...
-
Conjugated control of triple active bridge converter with common HFT
PublicationPaper presents synthetic analyses of single input, dual output DC/AC/DC converter with common high frequency transformer. Rise the problem of cross-coupling power flows between secondary terminals, under asymmetrical control operating condition. It also proposes a new approach to converter control, based on conjugated phase shift modulation and defines its limitations. Finally, the developed control technique was verified by simulation...
-
Call Control Evaluation in ASON/GMPLS Architecture
PublicationThe Automatically Switched Optical Network (ASON) utilizing Generalized Multi–Protocol Label Switching (GMPLS) protocols named as ASON/GMPLS is one of the propositions of Next Generation Network. The basic assumption of ASON control plane is a separation of call control from connection control. The control plane is divided into call control and connection control components. Presented work regards the problem of call control evaluation...
-
A new approach to designing control of dissolved oxygen and aeration system in sequencing batch reactor by applied backstepping control algorithm
PublicationThe Wastewater Treatment Plant (WWTP) is a very complex system, due to its nonlinearity, time-variance, and multiple time scales in its dynamics among others. The most important control parameter in a WWTP is the Dissolved Oxygen (DO) concentration. The tracking problem of the DO concentration is one of the most fundamental issues in biological wastewater treatment. Proper DO concentration control is necessary to achieve adequate...
-
The realization of ASON/GMPLS control plane
PublicationASON (Automatic Switched Optical Network) is a concept of optical network recommended in G.8080/Y.1304 by ITU-T. Control Plane of this network could be based on GMPLS (Generalized Multi-Protocol Label Switching) protocols like RSVP-TE, OSPF-TE, LMP. This solution is named ASON/GMPLS. In this chapter we present the control plane problems and proposes ASON/GMPLS network realization that are tested on testbed consists of three and...