Filters
total: 1590
filtered: 1076
displaying 1000 best results Help
Search results for: contact capacitive imaging
-
Evaluation of Respiration Rate Using Thermal Imaging in Mobile Conditions
PublicationRespiratory rate is very important vital sign that should be measured and documented in many medical situations. The remote measurement of respiration rate can be especially valuable for medical screening purposes (e.g. severe acute respiratory syndrome (SARS), pandemic influenza, etc.). In this chapter we present a review of many different studies focused on the measurements and estimation of respiration rate using thermal imaging...
-
Cross-sectional imaging of materials structure using PS-OCT
PublicationOptical low-coherence tomography is a measurement technique for non-contact and non-destructive investigation of materials inner structure. Nowadays, this method is highly applied in medical treatment especially in dermatology and ophthalmology. During our research we have developed an optical low-coherence tomography system with polarization state analysis for structure examination of a broad range of technical materials. In this...
-
Potentiometric Solid-Contact Multisensor System for Simultaneous Measurement of Several Ions
PublicationThe design and performance of potentiometric multisensor system made in solid-contact technology is described. Both, the measuring electrodes as well as the reference electrode are in a compact cell. The system allows for simultaneous measurement of various ions. The characteristics of the electrodes for Na+, K+ and Ca2+ ions were determined using the designed system and compared with ISEs of the same membrane composition in classical...
-
Measuring pulse rate with a webcam — A non-contact method for evaluating cardiac activity
PublicationIn this paper the simple and robust method of measuring the pulse rate is presented. Elaborated algorithm allows for efficient pulse rate registration directly from face image captured from webcam. The desired signal was obtained by proper channel selection and principal component analysis. A developed non-contact method of heart rate monitoring is shown in the paper. The proposed technique may have a great value in monitoring...
-
Morphology of damage inflicted on brittle polymer in lubricated contact under cyclic static load
PublicationIn this article morphology of damage inflicted on the polymethylmethacrylate (PMMA) plate in static point lubricated contact with a ball made of five different materials under cyclic normal load has been presented. It is argued that the counterface material and lubricating film play an important role in the damage process and the extent of damage inflicted in the PMMA plate.
-
Problems of 3d breast imaging
PublicationW poniższym artykule zaprezentowana zostanie idea stereoskopowego systemu pomiaru trójwymiarowej geometrii badanego obiektu. Taki sposób przetwarzania pomiarów umożliwi symulacje rozkłady temperatur na powierzchni ciała. Omówione zostaną problemy związane z konstrukcją takiego urządzenia.
-
Imaging forms in passive sonars
PublicationReferat jest kontynuacją tematyki organizacji zobrazowań we współczesnych systemach hydrolokacyjnych przedstawionej w referacie zaproszonym na ubiegłorocznym OSA dla systemów aktywnych. Tym razem dotyczy organizacji zobrazowań w systemach pasywnych. W praktyce, prócz prostych systemów nasłuchu i rejestracji dźwięków podwodnych, używanych przez badaczy fauny wodnej czy oceanografów, systemy pasywne są wykorzystywane w marynarkach...
-
Fluorescence imaging spectroscopy and microscopy
Publication -
Design Considerations of GaN Transistor Based Capacitive Wireless Power Transfer System
Publication -
MXene-based composites for capacitive deionization – The advantages, progress, and their role in desalination - A review
Publication -
Synthesis, Chemical Characterization and Multiscale Biological Evaluation of a dimericcRGD Peptide for Targeted Imaging of αVβ3 Integrin Activity
PublicationCyclic peptides containing the Arg-Gly-Asp (RGD) sequence have been shown to specifically bind the angiogenesis biomarker α V β3 integrin. We report the synthesis, chemical characterization, and biological evaluation of two novel dimeric cyclic RGD-based molecular probes for the targeted imaging of α V β3 activity (a radiolabeled version, 64Cu-NOTA-PEG4-cRGD2, for PET imaging, and a fluorescent version, FITC-PEG4-cRGD2, for in...
-
Microscopic Imaging to Visualize the Distribution of Dietary Nucleic Acids in Food Products of Various Origins
PublicationDietary nucleic acids (dietNAs) are being increasingly recognized as important food components with nutritional value. However, the precise dietary recommendations for dietNAs are limited, because established methods for determining the quantity and nutritional role of dietNAs are still lacking. One of the tools to narrow this gap could be microscopic imaging, as a convenient approach to visualize the abundance and distribution...
-
FURTHER REMARKS ON THE SURFACE VIS IMPRESSA CAUSED BY A FLUID-SOLID CONTACT
PublicationIt is well-known that, nano-mechanics should take into account not only physical phenomena occuring within the bulk but, first of all, the physical phenomena appropriate for a surface of two materials contact. The huge volume density of internal surfaces as well countours lines located within the nanomaterial results in our interest in, apart from classical form of mass, momentum and entropy transport, those modes of transportation...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Assessment of organic coating degradation via local impedance imaging
PublicationThe paper presents a new approach to organic coating condition evaluation at micrometer scale using localized impedance measurements. It is based on atomic force microscopy (AFM) in contact mode. Impedance is measured between conductive AFM tip and metal substrate covered with organic coating. A single-frequency voltage perturbation signal is applied between the electrodes and current response signal is registered. As the tip is...
-
Brain perfusion imaging with the use of parametric modelling basing on DSC-MRI data
PublicationW pracy do estymacji parametrów perfuzji mózgu: przepływu krwi mózgowej (cerebral blood flow, CBF), objętości krwi mózgowej (cerebral blood volume, CBV) oraz średniego czasu przejścia (mean transit time, MTT) wykorzystano pomiary DSC-MRI (Dynamic Susceptibility Contrast Magnetic Resonance Imaging). W modelowaniu danych MRI zastoswoano model trzykompartmentowy. Przedstawiono i porównano dwa podejścia do identyfikacji modelu różniące...
-
A new diagnostic IR-thermal imaging method for evaluation of cardiosurgery procedures
PublicationTwo methods for monitoring the state of the myocardium during cardiosurgical interventions based on thermal IR imaging are presented below. These methods, called static thermography and active dynamic thermography (ADT), use information about the distribution of temperature on the surface, and an external excitation source to induce thermal transient processes in a tested object. Recording the time series of thermograms allows...
-
An inverse algorithm for contact heat conduction problems with an interfacial heat source based on a first-order thermocouple model
PublicationInverse problems of contact heat conduction with an interfacial heat source are common in various fields of science, engineering and technology. In this study, an algorithm for their solution is developed based on an inverse parametric optimisation method with an impulse response function describing the heat partition and contact heat transfer. A first-order thermocouple model with a time constant parameter is embedded in the impulse...
-
Special Issue on Sliding Contact Bearings
Publication -
Measurements of droplet contact angle of nanofluids
PublicationPrzedstawiono wyniki pomiarów kąta zwilżania trzech nanocieczy: woda-Al2O3, woda-TiO2 oraz woda-Cu. Koncentracja nanocząstek wynosiła: 0.01%, 0.1% oraz 1%. Pomiary przeprowadzono dla podłoża szklanego, aluminiowego i ze stali nierdzewnej. Kąt zwilżania mierzono za pomocą goniometru, a także na podstawie zdjęć wykonanych za pomocą kamery cyfrowej.
-
Comparison of perforator location in dynamic and static thermographic imaging with Doppler ultrasound in breast reconstruction surgery
PublicationThis paper co mpares the effectiveness of the dTnorm and t90_10 parametrizations in dynamic thermography for imaging location of perforators in TRAM flaps in the intraoperative period. The results were compared with the location detected in a Doppler ultrasound examination. Cold and heat stimulation was used in dynamic thermography. Additionally, these results were compared with static...
-
Novel Vision Monitoring Method Based on Multi Light Points for Space-Time Analysis of Overhead Contact Line Displacements
PublicationThe article presents an innovative vision monitoring method of overhead contact line (OCL) displacement, which utilizes a set of LED light points installed along it. A light point is an, LED fed from a battery. Displacements of the LED points, recorded by a camera, are interpreted as a change of OCL shape in time and space. The vision system comprises a camera, properly situated with respect to the OCL, which is capable of capturing...
-
Driver’s Condition Detection System Using Multimodal Imaging and Machine Learning Algorithms
PublicationTo this day, driver fatigue remains one of the most significant causes of road accidents. In this paper, a novel way of detecting and monitoring a driver’s physical state has been proposed. The goal of the system was to make use of multimodal imaging from RGB and thermal cameras working simultaneously to monitor the driver’s current condition. A custom dataset was created consisting of thermal and RGB video samples. Acquired data...
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
PublicationLocal impedance imaging (LII) was used to visualise surficial deviations of AC impedances in polycrystalline boron-doped diamond (BDD). The BDD thin film electrodes were deposited onto the highly doped silicon substrates via microwave plasma-enhanced CVD. The studied boron dopant concentrations, controlled by the [B]/[C] ratio in plasma, ranged from 1 × 1016 to 2 × 1021 atoms cm−3. The BDD films displayed microcrystalline structure,...
-
Nanodiamond phantoms mimicking human liver: perspective to calibration of T1 relaxation time in magnetic resonance imaging
PublicationPhantoms of biological tissues are materials that mimic the properties of real tissues. This study shows the development of phantoms with nanodiamond particles for calibration of T1 relaxation time in magnetic resonance imaging. Magnetic resonance imaging (MRI) is a commonly used and non-invasive method of detecting pathological changes inside the human body. Nevertheless, before a new MRI device is approved for use, it is necessary...
-
Damage imaging algorithm for non-destructive inspection of CFRP/steel adhesive joints based on ultrasonic guided wave propagation
PublicationThe paper concerns assessing the quality of the adhesive connection between a steel plate and the reinforcing CFRP laminate. A three-stage algorithm for non-destructive damage imaging was developed. As the first step, an initial study involving dispersion curves of joint components was executed to determine the material parameters and the appropriate excitation frequency. During the second step, damage identification in three-layer...
-
Characterization and capacitive performance assessment of potato peels derived salt-induced porous carbons
Publication -
Hyperbolic heat conduction at a microscopic sliding contact with account of adhesion-deformational heat generation and wear
PublicationDifferent non-Fourier models were proposed to simulate temperatures in materials subjected to extremely fast thermal disturbances, when the speed of heat propagation should be concerned. The present study investigated temperature and heat balance at a microscopic sliding contact during a single frictional interaction based on the Cattaneo-Vernotte hyperbolic heat conduction equation. Two fundamental features of friction, namely,...
-
Method of reconstructing two-dimensional velocity fields on the basis of temperature field values measured with a thermal imaging camera
PublicationThis paper describes a novel numerical reconstruction procedure (NRP) of the velocity field during natural convective heat transfer from a two-sided, isothermal, heated vertical plate based only on the known temperature field obtained, e.g. with a thermal imaging camera. It has been demonstrated that with a knowledge of temperature distributions, the NRP enables the reconstruction of velocity fields by solving the Navier-Stokes...
-
Recent advances in gaseous imaging photomultipliers
Publication -
Applications of image registration in parametric imaging
PublicationArtykuł przedstawia możliwości poprawy jakości obrazów parametrycznych przez eliminacje artefaktów ruchowych w sekwencji obrazów. Zaprezentowano multimodalne wizualizacje obrazów oraz przedstawiono wyniki dopasowania różnych obrazów MRI do siebie.
-
Applications of image registration in parametric imaging
PublicationArtykuł przedstawia wyniki badań z zakresu wykorzystania metod nakładania obrazów w obrazowaniu parametrycznym. Podstawowe zastosowania obejmują korekcję artefaktów ruchowych oraz wizualizację obrazu multimodalnego.
-
The DICOM standard for medical thermal imaging
PublicationW pracy przedstawiono propozycję schematu danych dla potrzeb ujęcia jej w międzynarodowej normie DICOM. Schemat danych oraz oprogramowanie referencyjne przygotowane dla potrzeb aplikacji termografii w medycynie.
-
Thermal imaging and modelling of burned skin
PublicationW artykule przedstawiono wyniki eksperymentów in-vivo na zwierzętach w diagnostyce oparzeń z wykorzystaniem metod obrazowania termicznego w podczerwieni. Wyniki skorelowano z rezultatami otrzymanymi w symulacjach numerycznych tkanki skóry.
-
Distributed processing in medical, parametric imaging
PublicationArtykuł prezentuje metodę dystrybucji bazującej na JavaSpace do zastosowania w wyznaczaniu obrazów parametrycznych. Zaimplementowano metodologię Compute Server, którą użyto do aktywnej termografii i dynamicznych badań MRI mózgu.
-
IMAGING OF PROTON BRAGG PEAKS IN LiF
Publication -
Thermal Imaging in Wound Healing Diagnostics
PublicationOpisano wyniki projektu badawczego poświęconego opracowaniu metody obiektywnej diagnostyki ran pooperacyjnych w kardiochirurgii. Sprawdzono możliwość połączenia oceny obrazów RGB z obrazami termograficznymi oraz nową w medycynie metodą aktywnej termografii dynamicznej ADT. W projekcie zastosowano chłodzenie obszaru zainteresowania wykorzystując kriostat na dwutlenku węgla. W okresie powrotu do stanu równowagi termodynamicznej rejestrowane...
-
Thermal Imaging in Wound Healing Diagnostics
PublicationResults of a project searching for objective, quantitative evaluation of postoperative wound healing in cardiosurgery are presented. We propose simple thermal models of the healing processes after cardiosurgery interventions as objective descriptors allowing classification of patients for extraction and following recovery at home or for prolonged treatment in a hospital. Classification of healing as the normal process or as a process...
-
Reply to Comment on ‘Nanodiamond incorporated human liver mimicking phantoms: prospective calibration medium of magnetic resonance imaging’
PublicationDependence of the spin–lattice (T1) relaxation times on the nanodiamond concentration in human liver phantoms is discussed. Factors affecting stability and and reproducibility of these phantoms are presented. The need for comparative measurements on multiple MRI scanners for better understanding of potential variations in the obtained imaging data is emphasised.
-
Public Perception of Digital Contact Tracing App and Implications for Technology Acceptance and Use Models
PublicationGovernments are increasingly adopting digital contact tracing applications (DCT) as a key component of their response to the COVID-19 pandemic. However, governments are struggling to achieve widespread adoption of DCT necessary for obtaining the expected individual and public benefits associated with its use. Consequently, studies on DCT have focused on the barriers to DCT adoption in different contexts and possible ways of overcoming...
-
In vivo imaging of the human eye using a two-photon excited fluorescence scanning laser ophthalmoscope
PublicationBACKGROUND. Noninvasive assessment of metabolic processes that sustain regeneration of human retinal visual pigments (visual cycle) is essential to improve ophthalmic diagnostics and to accelerate development of new treatments to counter retinal diseases. Fluorescent vitamin A derivatives, which are the chemical intermediates of these processes, are highly sensitive to UV light; thus, safe analyses of these processes in humans...
-
Interpolation methods in GPR tomographic imaging of linear and volume anomalies for cultural heritage diagnostics
PublicationThis paper presents results of a ground penetrating radar (GPR) survey conducted in St. Joseph’s Church in Gdańsk, Poland. The aim of the study was to produce tomographic imaging of a renovated floor as well as the objects buried under the floor to detect linear and volume inclusions. The assumed track spacing was meaningfully greater than the single signal spacing in each track, which induced the need for interpolation methods...
-
Solid-Contact pH Sensor without CO2Interference with a Superhydrophobic PEDOT-C14as Solid Contact: The Ultimate “Water Layer” Test
Publication -
Comparative 3D DEM simulations of sand–structure interfaces with similarly shaped clumps versus spheres with contact moments.
PublicationThree-dimensional simulations of a monotonic quasi-static interface behaviour between initially dense cohesionless sand and a rigid wall of different roughness during tests in a parallelly guided direct shear test under constant normal stress are presented. Numerical modelling was carried out by the discrete element method (DEM) using clumps in the form of convex non-symmetric irregularly shaped grains. The clumps had an aspect...
-
CONTACT – communication protocol for family practitioners and specialists
Publication -
The influence of contact geometry on friction and wear characteristics
Publication -
Fouling in direct contact membrane distillation process
Publication -
Non contact multiband method for emissivity measurment.
PublicationW pracy omówiona została metoda bezkontaktowego wielopasmowgo pomiaru emisyjności. W oparciu o opracowany algorytm zbadany został wpływ poszczególnych elementów systemu i czynników zakłócających na dokładność wyznaczania emisyjności. Wyniki modelowania umożliwiają także ocenę dokładności całego systemu pomiarowego.
-
Electrical mapping of AISI 304 stainless steel subjected to intergranular corrosion performed by means of AFM-LIS in the contact mode
PublicationThe paper presents results of the AFM-based approach to local impedance spectroscopy (LIS) measurements performed in a 20 20 lm grid within an austenite grain–grain boundary region for sensitized AISI 304 stainless steel (SS). Maps of electrical parameters obtained on the basis of localized impedance spectra were demonstrated, presenting their changes and correlation with the sample topography. Performed research revealed significant...
-
The use of thermal imaging camera to estimate velocity profiles based on temperature distribution in a free convection boundary layer
PublicationThis work describes an attempt to assess whether the temperature field from a thermal imaging camera can be converted into a velocity field with an accuracy sufficient for qualitative conducting or describing the phenomenon, i.e. when the Navier-Stokes, Fourier-Kirchhoff and continuity equations are mutually coupled. The consequence of this link between temperature fields and velocity is the possibility to formulate the hypothesis...