Filters
total: 3489
filtered: 2837
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: SUPERCRITICAL POWER PLANT
-
Influence of landfill leachate on municipal wastewater treatment - model plant(WWTP-MP)
PublicationAbstract In the current study, wastewater treatment model plant (WWTP-MP) was used to investigate the possibilities of landfill leachate co-treatment together with municipal wastewater. The WWT-MP, designed as an A2O multiphase system, was fed with the raw municipal wastewater (from the WWTP Gdańsk "Wschód'', Qav.=82x103 m3/d) with increasing, from 1 to 5 % (vol.), quantity of landfill leachate (collected from Gdańsk landfill ''Szadółki")....
-
Optimization of thermal backfill configurations for desired high-voltage power cables ampacity
PublicationThe ampacity of high-voltage power cables depends, among others, on their core cross-sectional area as well as thermal resistivity of the thermal backfill surrounding the cables. The cross-sectional area of the power cables’ core is selected according to the expected power to be transferred via the cable system. Usually, the higher the power transfer required, the higher the cross-sectional area of the core. However, the cost of...
-
Models of Brushless Synchronous Generator for Studying Autonomous Electrical Power System
PublicationThis is a PhD dissertation. The work presented in this monograph was carried out at the Department of Power Electronics and Electrical Machines, Faculty of Electrical and Control Engineering at the Gdansk University of Technology. Developed during the research models of brushless synchronous generator ware verified using FEM based simulations and measurements conducted on the prototype generator. The main focus of the research...
-
Antimicrobial resistance of fecal indicators in muncipal wastewater treatment plant
PublicationAntimicrobial resistance of fecal coliforms (n = 153) and enterococci (n = 199) isolates was investigated in municipal wastewater treatment plant (WWTP) based on activated sludge system. The number of fecal indicators (in influent and effluent as well as in the aeration chamber and in return activated sludge mixture) was determined using selective media. Susceptibility of selected strains was tested against 19 (aminoglycosides,...
-
On energy, exergy, and environmental aspects of a combined gas-steam cycle for heat and power generation undergoing a process of retrofitting by steam injection
PublicationThe paper presents a study of retrofitting of a combined heat and power (CHP) plant aimed to increase the electric to heating power ratio. The modification would involve diverting part of the steam to the gas turbine, instead of letting it go to the steam turbine, using injection technique into a combustion chamber. Therefore, two potential retrofitting approaches are analyzed: steam injection gas turbine (STIGT) and combined steam...
-
Risk of power cables insulation failure due to the thermal effect of solar radiation
PublicationLow-voltage, as well as high-voltage power cable lines, are usually buried in the ground. The ampacity of the power cables in the ground mainly depends on the thermal resistivity of the soil, which may vary in a wide range. A common practice in power cable systems performance is to supply them from a pole of an overhead line. If so, a section of the line is located in free air and can be directly exposed to solar radiation. In...
-
Situational Awareness Network for the Electric Power System: the Architecture and Testing Metrics
PublicationThe contemporary electric power system is highly dependent on Information and Communication Technologies which results in its exposure to new types of threats, such as Advanced Persistent Threats (APT) or Distributed-Denial-of-Service (DDoS) attacks. The most exposed components are Industrial Control Systems in substations and Distributed Control Systems in power plants. Therefore, it is necessary to ensure the cyber security of...
-
An Optimal Power Point Tracking Algorithm in a Solar PV Generation System
PublicationThe non-linearity in I-V characteristics of a PV panel requires to be operated at knee point to extract maximum power. In order to operate the panel at optimal point, maximum power point tracking (MPPT) algorithm is employed in the control structure. The main objective of MPP tracking is to keep the operation at knee point of I-V characteristics under varying condition of temperature and solar insolation. Under non uniform solar...
-
Impact of configuration of earth continuity conductor on induced sheath voltages in power cables
PublicationIn high voltage power cable systems a problem of induced sheath voltages exist. Due to these voltages electric shock and damage of non-metallic outer sheath of the cables may occur. Exposure to voltage of the outer sheath may be very high in case of earth fault with high value of earth current. In order to reduce induced sheath voltages an earth continuity conductor (conductors) along power cables is applied. Configuration of this...
-
Induced Sheath Voltages In 110 Kv Power Cables – Case Study
PublicationThe paper considers shock hazard due to induced sheath voltages in 110 kV power cables. Various configurations of the metallic sheaths bonding and earthing (single-point bonding, both-ends bonding, cross-bonding) are analysed. Taking into account shock hazard and ability of the system to power transfer an optimal configuration is proposed.
-
Management Information Base module for electrical power system configuration and use
PublicationInternet standards describe a virtual information store, termed the Management Information Base (MIB), which is made available through Simple Network Management Protocol (SNMP). No standard MIB exists to date for monitoring power lines in facilities over IP network. This paper defines a subset of the MIB for power system monitoring.
-
Low Power Baseband Processor for M2M Reconfigurable Radio Test Platform
PublicationSoftware Defined Radio (SDR) is becoming more andmore frequently used technique for wireless communication. Itfacilitates as fast prototyping and is a versatile method fordeveloping new communication systems. SDR can be realizedbased on high computational capacity platform, where powerconsumption is no a primary concern like i.e. DVB or BTStransmitters. Another trend are low power systems, whereavailable power in reduced and more...
-
Compact and Integrated High-Power Pulse Generation and Forming System
PublicationThis paper presents comprehensive analytical, numerical and experimental research of the compact and integrated high-power pulse generation and forming system based on the flux compression generator and the electro-explosive forming fuse. The paper includes the analysis of the presented solution, starting from the individual components studies, i.e., the separate flux compression generator tests in field conditions and the forming...
-
Event-Triggered Communication in Cooperative, Adaptive Model Predictive Control of a Nuclear Power Plant’s Turbo–Generator Set
PublicationThis paper discusses the issue of optimizing the communication between the components of a cooperating control system formed by a pair of MPC controllers of a nuclear power plant turbine set using online recursive least squares identification. It is proposed to use event-triggered communication, i.e., sending information only at selected time instants, as opposed to the standard approach where communication is triggered by time...
-
Anaerobic bacteria in wastewater treatment plant
Publication -
Variable speed small hydropower plant
Publication -
Oxylipins in Plant Protection/Disease Management
Publication -
Testing Situation Awareness Network for the Electrical Power Infrastructure
PublicationThe contemporary electrical power infrastructure is exposed to new types of threats. The cause of such threats is related to the large number of new vulnerabilities and architectural weaknesses introduced by the extensive use of Information and Communication Technologies (ICT) in such complex critical systems. The power grid interconnection with the Internet exposes the grid to new types of attacks, such as Advanced Persistent...
-
APPLICATION OF INFRARED THERMOGRAPHY TO NON-CONTACT TESTING OF AD/DC POWER SUPPLY
PublicationTesting of AC/DC power supplies using the thermography was carried out in order to assess their assembly and operation correctness before launching them on the market. The investigation was carried out for 17 AC/DC power supplies which passed the standard tests (measurements of their basic parameters and characteristics). The investigation consisted of two steps. In the first step the dispersion of temperature on power supply boards...
-
Model of aeration system at biological wastewater treatment plant for control design purposes
PublicationThe wastewater treatment plant (WWTP) is a dynamic, very complex system, in which the most important control parameter is the dissolved oxygen (DO) con-centration. The air is supplied to biological WWTP by the aeration system. Aera-tion is an important and expensive activity in WWTP. The aeration of sewage ful-fils a twofold role. Firstly, oxygen is provided as the main component for biolog-ical processes. Secondly, it supports...
-
SELECTED COMBINED POWER SYSTEMS CONSISTED OF SELFIGNITION ENGINE AND STEAM TURBINE
PublicationThis paper presents optimization of selected combined diesel engine-steam turbine systems. Two systems: the system combined with waste heat one-pressure boiler only and its version containing additionally low-pressure boiler proper feeding degasifier and the system of two-pressure cycle, were taken into considerations. Their surplus values of power output and efficiency associated with utilization of waste heat contained in piston...
-
Power converter interface for urban DC traction substations - solutions and functionality.
PublicationThis paper focuses on extending an urban DC traction substation functionality by means of an additional power converter interface (PCI). In particular, by enabling bidirectional energy exchange between LV DC traction grid, AC grid and V2G chargers. Among other things, the presented material compares general attributes of the most promising DC/DC converters that can be used in a PCI, meet the requirements of galvanic isolation and...
-
Low energy electron mass stopping power in H2
PublicationWe present experimental mass stopping powers of electrons in gaseous H2 obtained with a newly developed electron time-of-flight spectrometer, for the incident electron energy range of 10eV to 25eV. In our procedure the average energy loss is derived from our conversion of measured electron time-of-flight spectra into equivalent electron energy loss spectra so as to obtain the values of mass stopping power for electron scattering...
-
Advancing Solar Energy: Machine Learning Approaches for Predicting Photovoltaic Power Output
PublicationThis research is primarily concentrated on predicting the output of photovoitaic power, an essential field in the study of renewable energy. The paper comprehensively reviews various forecasting methodologies, transitioning from conventional physical and statistical methods to advanced machine learning (ML) techniques. A significant shift has been observed from traditional point forecasting to machine learning-based forecasting...
-
Task Scheduling – Review of Algorithms and Analysis of Potential Use in a Biological Wastewater Treatment Plant
PublicationThe idea of task scheduling is to increase the efficiency of a system by minimising wasted time, evenly loading machines, or maximising the throughput of machines. Moreover, the use of appropriate scheduling algorithms often leads to a reduction in the energy costs of the process. Task scheduling problems are found in a variety of industrial areas, and their scale changes significantly depending on the problem. This review shows...
-
APPLICATION OF THE KOSECKI’S METHOD IN DESIGNING OF OFFSHORE WIND POWER PLANTS FOUNDATION
PublicationThe concept of offshore wind power plants has been well developed in many European countries. There is no such thing as design of offshore wind power plants according to national tradition. The main problem is the lack of standards and guidelines. Ones being applied are Scandinavian or American methods which are not fully adapted to the conditions of the Baltic Sea. The article focuses on the monopile design, as it is currently the...
-
Code development of a DSP-FPGA based control platform for power electronics applications
PublicationThis paper focuses on the implementation of power electronics algorithms in control platforms based on DSP-FPGA. Today’s power electronics technology demands high power computation with high speed interfacing at the same time. The most popular configuration is a DSP for the former and a FPGA for the latter. The main goal of this work was to develop a generic control system for power electronics application, but it is explained...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Integrated plant-wide modelling for evaluation of the energy balance and greenhouse gas footprint in large wastewater treatment plants
PublicationModern wastewater treatment plants (WWTPs) should maintain a balance between three combined sustainability criteria, including effluent quality, energy performance and greenhouse gas (GHG) emissions. All of these criteria were considered in the integrated plant-wide model developed in this study. The proposed model incorporates new features, including: (i) the addition of associated facilities to the overall energy balance and...
-
Evaluation of VSC Impact on Power System Using Adequate P-Q Capability Curve
PublicationRenewable energy sources, which are becoming increasingly popular, often use a voltage source converter (VSC) for connection to the power system. Assessing the effects of connecting such a source to the power system is essential to ensure the proper operation of the power system and the connected source. For this purpose, it is necessary to know the range of active and reactive power generation by the converter. The authors indicate...
-
Prediction of Wastewater Quality at a Wastewater Treatment Plant Inlet Using a System Based on Machine Learning Methods
PublicationOne of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at...
-
Analysis of Ferroresonance Mitigation Effectiveness in Auxiliary Power Systems of High-Voltage Substations
PublicationFerroresonance in power networks is a dangerous phenomenon, which may result in overcurrents and overvoltages, causing damage to power equipment and the faulty operation of protection systems. For this reason, the possibility of the occurrence of ferroresonance has to be identified, and adequate methods need to be incorporated to eliminate or reduce its effects. The aim of this paper is to evaluate the effectiveness of ferroresonance...
-
Evolution of the HVDC Link Connecting Offshore Wind Farms to Onshore Power Systems
PublicationThis paper presents an overview of the DC link development and evolution dedicated to HVDC structure for connecting offshore wind power plants to onshore power systems. The growing demand for the green energy has forced investors in power industry to look for resources further out at sea. Hence, the development of power electronics and industrial engineering has enabled offshore wind farms to be situated further from the shore...
-
Pressure losses and power balance in the unloaded satellite pump
PublicationThis paper presents the results of laboratory research the pressure drop in the internal channels of unloaded satellite pump pumping tap water. Also shows the characteristics of the increase of pressure in the working chamber of the pump. It has been shown that after reaching cavitation, increase pump speed will increase in torque. This is the moment of inertia caused by the increase of the operating mechanism and the liquid contained...
-
PRESSURE LOSSES AND POWER BALANCE IN THE UNLOADED SATELLITE PUMP
PublicationThis paper presents the results of laboratory research the pressure drop in the internal channels of unloaded satellite pump pumping tap water. Also shows the characteristics of the increase of pressure in the working chamber of the pump. It has been shown that after reaching cavitation, increase pump speed will increase in torque. This is the moment of inertia caused by the increase of the operating mechanism and the liquid contained...
-
Security Requirements and Controls for Incident Information Sharing in the Polish Power System
PublicationAmong the strategies of protecting information assets of the power system, sharing of information about current cybersecurity incidents between energy operators appears to be a prerequisite. Exchange of information leads to the effective detection of attacks and exploited vulnerabilities as well as the identification of countermeasures. This paper presents the results of continuation of our works on developing a secure and efficient...
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublicationThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
The Effects of Host Plant Genotype and Environmental Conditions on Fungal Community Composition and Phosphorus Solubilization in Willow Short Rotation Coppice
Publication -
Performance and Power-Aware Modeling of MPI Applications for Cluster Computing
PublicationThe paper presents modeling of performance and power consumption when running parallel applications on modern cluster-based systems. The model includes basic so-called blocks representing either computations or communication. The latter includes both point-to-point and collective communication. Real measurements were performed using MPI applications and routines run on three different clusters with both Infiniband and Gigabit Ethernet...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Influence of Shunt Compensation with SVC Devices on Resonance Risk in Power Systems
PublicationMany analyses are required to locate a new reactive power source in a power system. The choice of a location is a very complex matter which requires various aspects to be considered. Selecting a location also entails the necessity to assess it from the point of view of the selected compensator’s structure as well as the system’s performance in various states with the new device on. The paper presents the issues of assessing compensator...
-
System of protection against electric shock for circuits with power electronics converters
PublicationModern low voltage circuits are very often equipped with power electronics converters, therefore in these circuits non-sinusoidal earth currents (touch currents) may occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based...
-
Transient modeling in common DC link of power converters
PublicationПредмет исследования. Представлена математическая модель силовых преобразователей электропривода, питающихся от общего звена постоянного тока, на примере тяговых электроприводов карьерного самосвала БЕЛАЗ-90 мощностью 280 кВт. Модель выполнена в пакете MATLAB/Simulink. Новизна предложенной модели заключается в применении новой топологии силовой схемы для исследования работы двух инверторов, под- ключенных к одному звену постоянного...
-
Implementation of power transformer controlled switching algorithm
PublicationThe article presents two new algorithms of controlled switching the power transformer. The main aim of the paper is to obtain formulas that determine the moments of closing of the circuit breaker poles. The study contains projects of control systems for both algorithms. Mathematical formulas for the time instants of the breaker poles closing were developed on the basis of electric circuit theory and magnetic circuit theory. The...
-
Nonlinear model of a synchronous generator for analysis of more electric aircraft power systems
PublicationA nonlinear model for studying a variable-speed synchronous generator (SG) in more electric aircraft (MEA) power system has been developed. The saturation effects of the SG magnetic circuit have been considered. The model has been implemented in the Synopys/Saber simulation environment. The modelling language MAST has been used to elaborate the SG model. The model exhibit a network with the same number of external terminals/ports...
-
Scrutiny of power grids by penetrating PV energy in wind farms: a case study of the wind corridor of Jhampir, Pakistan
PublicationThis study examines the problems caused by intermittent renewable energy sources, especially wind farms, and suggests a different solar energy penetration strategy to improve their loading capacity. The study uses real-time data from a wind farm in Jhampir, Pakistan, to analyse and assess various aspects of grid stations connected to wind farms. Electrical Transient Analyzer Program is used to validate the results by linking...
-
Scrutiny of power grids by penetrating PV energy in wind farms: a case study of the wind corridor of Jhampir, Pakistan
PublicationThis study examines the problems caused by intermittent renewable energy sources, especially wind farms, and suggests a different solar energy penetration strategy to improve their loading capacity. The study uses real-time data from a wind farm in Jhampir, Pakistan, to analyse and assess various aspects of grid stations connected to wind farms. Electrical Transient Analyzer Program is used to validate the results by linking these...
-
The concept of a new two-stage fuse for high power pulse forming
PublicationThis manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...
-
Photovoltaic Maximum Power Point Technique based on Incremental Conductance (INCON) control algorithm
PublicationMaximum output power status can significantly improve the deployment rate of solar energy system. In order to get the maximum power output, issue of tracking maximum power point (MPP), reduced harmonics around MPP and improve efficiency of the solar power energy system, this paper presents the improved maximum power point tracking (MPPT) control...
-
High power, medium voltage, modular active power filtering system
Publication