Filters
total: 4239
filtered: 3096
-
Catalog
- Publications 3096 available results
- Journals 4 available results
- Conferences 5 available results
- People 32 available results
- Inventions 1 available results
- Projects 2 available results
- Laboratories 1 available results
- Research Equipment 8 available results
- e-Learning Courses 131 available results
- Events 9 available results
- Offers 1 available results
- Open Research Data 949 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: STATIC LOAD TEST
-
Static load test on concrete pile – instrumentation and results interpretation
PublicationFor some time (since 8-10 years in Poland) a special static load tests on instrumented piles are carried out. Such studies are usually of a scientific nature and provide detailed quantitative data on the load transfer into the ground and characteristics of particular soil layers interaction with a pile shaft and pile base. Deep knowledge about the pile-subsoil interaction can be applied for a various design purposes, e.g. numerical...
-
Static Load Test on Instrumented Pile – Field Data and Numerical Simulations
PublicationFor some time (since 8-10 years in Poland) a special static load tests on instrumented piles are carried out. Such studies are usually of a scientific nature and provide detailed quantitative data on the load transfer into the ground and characteristics of particular soil layers interaction with a pile shaft and pile base. Deep knowledge about the pile-subsoil interaction can be applied for a various design purposes, e.g. numerical...
-
Identification of residual force in static load tests on instrumented screw displacement piles
PublicationOccurrence of the so-called residual force of an unknown value significantly disturbs interpretation of static load tests performed on piles equipped with additional measuring instruments. Screw displacement piles are the piling technology in which the residual force phenomenon is very common. Its formation mechanism is closely related to the installation method of this type of piles, which initiates generation of negative pile...
-
Bearing capacity of piles based on static load tests and calculation principles provided by EN 1997-1
PublicationW artykule scharakteryzowano i przeanalizowano ogólne zalecenia Eurokodu 7 dotyczące wyznaczania nośności pali na podstawie próbnych obciążeń statycznych. Porównano je z zaleceniami dotychczasowej polskiej normy PN-83/B-02482. Przedstawiono kilka przykładów interpretacji rzeczywistych wyników próbnych obciążeń pali według zaleceń wyżej wymienionych dwóch norm wraz z analizą porównawczą.
-
Screw displacement pile shaft deformations measured by vibrating wire and fiber optic systems during a static load test
PublicationThis paper describes a full scale static load test performed on a 400 mm diameter screw displacement pile equipped with four different strain measuring systems. Three types of vibrating wire strain gauges (VWSG) were used: global - retrievable, local attached to steel pipe and local concrete embedded. The fourth system was distributed fiber optic sensors based on Rayleigh back scattering (DFOS) - three in the pile cross section....
-
Load capacity of steel-aluminium brackets under static and cyclic laboratory tests
PublicationThe aim of the research is the laboratory investigation of steel-aluminium brackets employed to fasten lightweight curtain walls to building facilities. Static pressure, suction forces, and cyclic loads parallel to end plates (horizontal – to simulate wind influence) were applied in the study. The steel-aluminium brackets were tested on a reinforced concrete substrate made of C30/37 concrete class to simulate the real working conditions....
-
Load Test of Railway Viaduct Built Using Crosswise Launching Technology
Publication -
Morphology of damage inflicted on brittle polymer in lubricated contact under cyclic static load
PublicationIn this article morphology of damage inflicted on the polymethylmethacrylate (PMMA) plate in static point lubricated contact with a ball made of five different materials under cyclic normal load has been presented. It is argued that the counterface material and lubricating film play an important role in the damage process and the extent of damage inflicted in the PMMA plate.
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublicationLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
Corrugated Sheeting as a Member of a Shear Panel Under Repeated Load—Experimental Test
PublicationIn stressed-skin design, the cladding stiffening effect on structures is taken into account. However, the “traditional” design is more usual, wherein this effect is neglected. Even if the diaphragm actions are not regarded, in particular cases such as big sheds (and others), the parasitic (unwanted) stressed-skin action may occur with the result of leakage or even failure. The structures of this kind have already been built. Thus,...
-
Behaviour of asphalt concrete in cyclic and static compression creep test with and without lateral confinement
PublicationArtykuł przedstawia wpływ metodyki badań na określanie parametrów betonu asfaltowego. Wykazano, że badania pełzania bez skrępowania bocznego w większym stopniu uwypuklają wpływ asfaltu na parametry badanego betonu asfaltowego natomiast w badaniach ze skrępowaniem bocznym, zarówno rola asfaltu jak i szkieletu mineralnego jest uwzględniana przy ocenie parametrów betonu asfaltowego. Ponadto wykazano, że lepszymi miarami do oceny betonu...
-
Test-supported numerical analysis for evaluation of the load capacity of thin-walled corrugated profiles
Publication -
Load test of new European record holder in span length among extradosed type bridges
PublicationThe article presents acceptance load tests of a newly built extradosed MS-3 bridge located along the national road DK-16 near Ostróda (Poland). The structure features significant dimension in European reference scale. It is a new record holder in span length regarding this distinct bridge category. Its length ranges 206 m. Static and dynamic load tests were performed here. The program was extended by entire structural laser scanning...
-
Mechanical properties of Precontraint 1202S coated fabric under biaxial tensile test with different load ratios
PublicationThe paper describes a method of laboratory tests necessary for identifying the mechanical properties of polyester coated fabrics named Precontraint 1202S with PVDF surface treatment. Two sets of initial material parameters for dense net model and orthotropic model are specified. Material parameters for Precontraint 1202S coated fabric are specified on the basis of the biaxial tensile tests for different load ratios. In order to...
-
GB-SAR in the Diagnosis of Critical City Infrastructure—A Case Study of a Load Test on the Long Tram Extradosed Bridge
Publication -
Report no: WOiO /II/46/2015 - Construction node verification test, estimation of breaking load (shear force) and destruction form
PublicationA new generation of tanks for LNG transportation has been designed. Mass reduction forced our customer to use three different materials: austenitic steel, aluminium alloy and LNG compressed wood between them. The expertise concerns structural node between tank foundation and suspension. Expertise contains: description of object of test, test principals, results and conclusions
-
Prediction of pile shaft capacity in tension based on some direct CPT methods – Vistula Marshland test site
PublicationThis paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with a diameter of 0.4 m and the length...
-
Load testing of a suspended footbridge in Radom (Poland)
PublicationThe footbridge in Radom is a suspended bridge of an interesting architectural form. The structure was de-signed for 4 kN/m2 of crowd loading. Dynamic calculations were not included in the design. The structure’s acceptance tests took place on the 14th of October 2016. The behaviour of the footbridge in static testing met the expectations. Unfortunately, as a result of dynamic tests, dangerous behaviour of the footbridge was revealed....
-
Load-settlement characteristics of piles working in a group
PublicationLoad-settlement characteristic (Q-s) of an axially loaded pile can be empirically determined from a static pile load test or on the basis of calculations using, e.g. transfer functions or numerical methods (FEM). The transfer functions method usually rely on empirical data, i.e. the function parameters are determined on the basis of numerous pile test results. Thus this method takes into account pile installation technology and...
-
Load Tests of the Movable Footbridge Over the Port Canal in Ustka
PublicationThe paper presents the acceptance tests carried out on the open footbridge over the port canal in the Port of Ustka. The steel footbridge construction is created by a single pylon to which a movable truss span is suspended with a theoretical span of 52.3 m. The studies about load test of the object included static and dynamic extortion and measurements. In static tests the ballast was of pallets with concrete blocks. Dynamic studies...
-
Prediction of Pile Shaft Capacity in Tension Based on Some Direct CPT Methods—Vistula Marshland Test Site
PublicationThis paper presents different CPT methodologies for the prediction of the pile shaft resistance in tension on the example of three reference screw piles of the Jazowa test site in Poland. The shaft capacity was estimated based on the cone resistance, sleeve friction and CPT excess pore water pressure. Three piles with diameter 0.4 m and the length varied from 8 m to 14.6 m were subjected to static load tests in tension. Their...
-
OPTICAL STRAIN MEASUREMENT OF CONCRETE VERSUS MANUAL EXTENSOMETER MEASUREMENT BASED ON THE TEST RC DEEP BEAM IN A COMPLEX STATE OF STRESS
PublicationThe purpose of this study is to compare the strain measurement techniques of concrete in R-C element subjected to the monotonic load up to the failure. In the analysis manual extensometer methods of measurements and the optical system ARAMIS for non-contact three-dimensional measurements of deformation was used. The test sample was a cantilever deep beam loaded throughout the depth which was a part of the reinforced concrete deep...
-
Vibro piles performance prediction using result of CPT
PublicationVibro piles belong to the group of full displacement piles with an expanded base, characterised by a very high load capacity, especially in non-cohesive soils. The problem is to adopt a reliable method for the determination of full load–settlement (Q–s) curve. A frequent difficulty is the determination of the load capacity limit based on the static load test because the course of the load–settlement curve is of a linear nature....
-
Design of a test bench for determining the general characteristics of an internal combustion engine using a hydraulic power take-off system
PublicationThe paper presents a design of an engine test bench, which is used to determine the general characteristics of a truck engine using a power take-off (PTO). PTO drives a hydraulic system that generates a load on the engine at various points in its operation in the power range specified by the hydraulic system. The design allows for stationary and mobile tests with the test bench mounted on the truck, without any modification of...
-
Stability and load bearing capacity of a braced truss under upward wind loading
PublicationThe paper is focused on the numerical and experimental investigation of stability of a steel truss under upward wind loading. The structure was stiffened by elastic braces situated at the top and bottom chord. Usually the lateral (translational) brace stiffness is considered. However, the rotational stiffness of braces caused by interaction between torsional stiffness of the truss top chord and bending stiffness of the roof elements...
-
Stability and load bearing capacity of a braced truss under upward wind loading
PublicationThe paper is focused on the numerical and experimental investigation of stability of a steel truss under upward wind loading. The structure was stiffened by elastic braces situated at the top and bottom chord. Usually the lateral (translational) brace stiffness is considered. However, the rotational stiffness of braces caused by interaction between torsional stiffness of the truss top chord and bending stiffness of the roof elements...
-
Numerical modelling and analysis of steel specimens subjected to marine immersed corrosion and tensile load
PublicationThe present study develops numerical models to analyse the behaviour of steel specimens subjected to marine immersed corrosion degradation and tensile load. The finite element method with the use of the explicit dynamic solver LS-DYNA, satisfying the quasi-static conditions, is employed. Two numerical models are developed, where in the first one, the scans of surfaces gathered from corroded plate specimens are implemented directly...
-
Analiza numeryczna i badania doświadczalne wpływu usytuowania stężeń na nośność wyboczeniową modelu kratownicy
PublicationIn the present research the results of experimental test and numerical analyses of a model of a typical truss are presented. The truss linear buckling analysis and non linear static analyses with respect to material and geometrical nonlinearity are conducted. For different stiffnesses and location of braces, the critical load and limit load for the truss are calculated and the threshold bracing stiffness is found. The results of...
-
Stability of an Innovative Cold-Formed GEB Section
PublicationThis paper is focused on the numerical analysis and experimental test of stability of the cold-formed profile with an innovative GEB cross-section. For the shell model of the axially compressed member, the linear buckling analysis and the nonlinear static analysis were carried out. In the numerical research, the buckling load and the limit load for variable section heights were obtained. Some of the results were compared with the...
-
FEM modelling of screw displacement pile interaction with subsoil
PublicationPredicting the-settlement characteristics of piles is an important element in the designing of pile foundations. The most reliable method in evaluating pile-soil interaction is the static load test, preferably performed with instrumentation for measuring shaft and pile base resistances. This, however, is a mostly post-implementation test. In the design phase, prediction methods are needed, in which numerical simulations play an...
-
Direct design of Controlled Modulus Columns (CMC) based on in-situ testing
PublicationIn this paper, the serviceability limit state and bearing capacity of tension screw displacement piles were analyzed using the results of static pile load tests, carried out on the test plot near the Elbląg city, and field, and laboratory tests. The paper presents the methodology of determining the pile load-settlement curve using different types of t-z transfer functions. The new method of constructing the pile load-settlement...
-
Shaft friction from the DMT and direct shear interface tests
PublicationThe article presents preliminary attempt to create tri-linear transfer curves for describing pile behaviour under axial loading. Transfer curves would use the parameter measured in dilatometer test, particularly a constrained modulus MDMT. The proposed method is based on concrete rough and smooth interface tests performed in a direct shear apparatus. Based on the obtained mobilization curves, relationships were created between...
-
Mechanizm współpracy z gruntem pali prefabrykowanych wbijanych w świetle próbnych obciążeń pali oprzyrządowanych
PublicationOpis badań i wyniki próbnych obciążeń statycznych dwóch pali prefabrykowanych wbijanych oprzyrządowanych w aparaturę do pomiaru rozkładu siły osiowej wzdłuż trzonu pala. Analiza wpływu czasu i procesu wbijania na charakterystykę osiadania pali prefabrykowanych wbijanych. Identyfikacja siły rezydualnej w palu prefabrykowanym wbijanym i jej wpływ na interpretację pomiarów ekstensometrycznych w próbnym obciążeniu pala. Wnioski na...
-
Bearing capacity of monotonically installed tapered piles in medium dense Fontainebleau sand
PublicationA series of installation of tapered piles in medium-dense Fontainebleau sand were performed in the geotechnical centrifuge at Gustave Eiffel University. The models of piles with three different shapes - straight profile (S), and with taper angle of 0.70 degrees (T1), and 1.4 degrees (T2) were used. The piles were instrumented with fiber optic wires on the shaft and load cell at the base. After monotonic installation, the models were...
-
Sustainable development requires risky decisions - problematic 300 ton overweight transport passing a bridge
PublicationOversize load passages over bridges are one of the research issues related to sustainable development that engineering and scientific teams around the world have to deal with . The article presents the scope of activities that enabled the passage of an oversized vehicle with a total weight of over 300 tons over a reinforced concrete slab. The bridge load capacity is 30 tons. In order to assess the capacity of the bridge, detailed...
-
New concept of drilling auger for displacement pile installation
PublicationIn 2020, a new version of the screw displacement auger for pile installation in soil was developed and patented in Poland. It was named DPDT (Displacement Pile Drilling Tool). The general aim of its development was to reduce the soil resistances to the auger during screwing into the ground while maintaning a good load-bearing capacity for the screw displacement piles. The “DPDT-Auger” prototype was tested as a scaled-down model...
-
Mechanical response of human thoracic spine ligaments under quasi-static loading: An experimental study
PublicationPurpose This study aimed to investigate the geometrical and mechanical properties of human thoracic spine ligaments subjected to uniaxial quasi-static tensile test. Methods Four human thoracic spines, obtained through a body donation program, were utilized for the study. The anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), capsular ligament (CL), ligamenta flava (LF), and the interspinous ligament and...
-
Influence of Installation Effects on Pile Bearing Capacity in Cohesive Soils – Large Deformation Analysis Via Finite Element Method
PublicationIn this paper, the whole process of pile construction and performance during loading is modelled via large deformation finite element methods such as Coupled Eulerian Lagrangian (CEL) and Updated Lagrangian (UL). Numerical study consists of installation process, consolidation phase and following pile static load test (SLT). The Poznań site is chosen as the reference location for the numerical analysis, where series of pile SLTs...
-
Instrumented end notched flexure - Crack propagation and process zonemonitoring Part II: Data reduction and experimental
PublicationA mode II instrumented end notched flexure three point bending (ENF) adhesion test is described. The adhesive joint consists of two aluminium alloy (AW7075-T6) plates bonded with a structural epoxy adhesive (Hysol EA 9395™). Strain gauges are attached to the outer surface (backface) of the substrates in the lengthwise direction to measure local surface strain during crack propagation. Simultaneously, load/displacement measurements...
-
RESEARCH ON HYDRODYNAMIC PEEK JOURNAL BEARINGS LUBRICATED WITH WATER AND OIL
PublicationThe main purpose of the research was to determine the possibilities and experimentally test the benefits of replacing conventional oil lubrication with ecological water lubrication. Tests were carried out on a test rig for hydrodynamic radial bearings under conditions representative of the expected applications for the bearing in water turbines. Bearings made from the polymer material PEEK (polyether ether ketone) were tested under static...
-
Badanie modułu odkształcenia podłoża gruntowego w nasypie kontrolowanym za pomocą płyty statycznej i lekkiej płyty dynamicznej
PublicationW praktyce inżynierskiej, zarówno projektowej, jak i wykonawczej, niewątpliwie przydatne są korelacje między parametrami geotechnicznymi. Artykuł przedstawia polowe badania porównawcze lekką płytą dynamiczną (LFWD) oraz płytą statyczną (VSS), wraz określeniem zależności korelacyjnych pomiędzy modułem odkształcenia podłoża wyznaczonym za pomocą lekkiej płyty dynamicznej EVd oraz pierwotnym i wtórnym modułem odkształcenia EV1, EV2....
-
Numerical analysis of pile installation effects in cohesive soils
PublicationIn this thesis the empirical equation for radial effective stress calculation after displacement pile installation and following consolidation phase has been proposed. The equation is based on the numerical studies performed with Updated Lagrangian, Arbitrary Lagrangian-Eulerian and Coupled Eulerian-Lagrangian formulations as well as the calibration procedure with database containing world-wide 30 pile static loading tests in cohesive...
-
Badania charakterystyki obciążeń oddziałujących na modułowe urządzenie dylatacyjne w pasie ruchu ciężkiego autostrady A8
PublicationPrzedstawiono badania urządzenia dylatacyjnego typu nożycowego. Dokonano statycznych i dynamicznych pomiarów odkształceń oraz przemieszczeń konstrukcji nożyc na najbardziej obciążonym pasie autostrady A8. Określono wpływ oddziaływania dynamicznego oraz sporządzono histogramy obciążeń i współczynników przewyższenia dynamicznego na podstawie pomiarów ciągłych w okresie nasilonego ruchu. Wskazano przyczyny degradacji urządzenia. Odniesiono...
-
Quasi-Static Response
PublicationConcern for the quasi-static response of ship and offshore structures, as required for safety and serviceability assessments. Attention shall be given to uncertainty quantification of quasi-static load and response analysis approaches, and their limitations, including exact and approximate methods for derivation of different acceptance criteria.
-
Pile Model Tests Using Strain Gauge Technology
PublicationOrdinary pile bearing capacity tests are usually carried out to determine the relationship between load and displacement of pile head. The measurement system required in such tests consists of force transducer and three or four displacement gauges. The whole system is installed at the pile head above the ground level. This approach, however, does not give us complete information about the pile-soil interaction. We can only determine...
-
Opracowanie procedury i badania wytrzymałościowe połączeń spawanych pomiędzy rurą kwadratowa a elementami giętymi na zimno ze stali S355 oraz testowanie połączeń o grubości 4, 6, 8mm typu S355
PublicationCelem pracy było: - opracowanie procedury badania wytrzymałości połączeń spawanych rozciąganych w kierunku prostopadłym i w kierunku równoległym (ścinanych) do osi spoiny. Spoiny te łączyły elementy rur kwadratowych o różnej grubości z elementami w kształcie ceownika giętymi na zimno. - wykonanie próbek do badań wytrzymałościowych wyciętych z elementów spawanych dostarczonych przez Zakład Produkcyjny firmy Borga obciążonych prostopadle...
-
ENERGY ANALYSIS OF PROPULSION SHAFT FATIGUE PROCESS IN ROTATING MECHANICAL SYSTEM PART I TESTING SIGNIFICANCE OF INFLUENCE OF SHAFT MATERIAL FATIGUE EXCITATION PARAMETERS
PublicationThe article discusses the problem of mathematical modelling of energy conversion processes in a rotating mechanical system for the purpose of identifying fatigue states of propulsion shafts in this system. A simplified physical model of the analysed system, constructed in an appropriate scale, has made the basis for the experimental research. The research programme took into consideration mechanical fatigue excitation of the model...
-
Displacement measurements during load testing of railway arch bridge
PublicationThe paper discusses issues concerning load tests carried out on a twin-track, arch railway bridge over the Martwa Wisla river in Gdansk. Currently, it is the bridge with the longest span in its class in Poland. The load-bearing structure consists of three no-hinge arches and an orthotropic deck suspended from them. The studies of the structure assumed the performing of static and dynamic tests. The paper presents the method for...
-
Investigation of buckling resistance of columns using non-linear static and dynamic analysis
PublicationThe aim of this paper is to investigate the stability process in an axially compressed column using a static and dynamic finite element analysis by taking both the geometric and material non-linearity into account. The perfect column and column with geometric imperfections were analysed. The linear buckling analyses were used to obtain the lowest buckling load and shapes of buckled forms that were taken into account as initial...
-
Analysis of the influence of geometrical imperfections on the equivalent load stabilizing roof truss with lateral bracing system
PublicationThe paper is focused on the numerical analysis of the stability and load bearing capacity of a flat steel truss. The structure was supported by elastic lateral braces. The translational and rotational brace stiffness was taken into account. The linear buckling analysis were performed for the beam and shell model of the truss. The nonlinear static analysis were conducted for the structure initial geometric imperfections. As a result...