Filters
total: 282
Search results for: PULSE CURRENT
-
Current divider-based nanosecond high current pulse measuring systems
PublicationThis paper presents the analysis of the new approach to the measurement methodology of significant values (in order of hundreds of kA) and huge steepness (in order of MA/μs) current pulses based on current dividers along with a comparison of the various types transducers suitability in measuring systems with such extreme parameters. Such dividers are used to extend the measurement ranges of current transducers with limited current...
-
Bearing current path and pulse rate in PWM-inverter-fed induction
Publication -
Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
PublicationThe reported research aims at improving the quality of three-phase rectifier supply currents. An effective method consists of adding properly formed booster voltages to the fundamental supply voltages using a series active filter. In the proposed solution, the booster voltages are generated by three single-phase systems consisting of inverters, LC filters, and single-phase transformers. The application of LC couplings ensures low...
-
Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
PublicationThe paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18-pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism...
-
Pulse-Modulated Radio-Frequency Alternating-Current-Driven Atmospheric-Pressure Glow Discharge for Continuous-Flow Synthesis of Silver Nanoparticles and Evaluation of Their Cytotoxicity toward Human Melanoma Cells
Publication -
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
A robust 18-pulse diode rectifier with coupled reactors
PublicationThe article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Analysis of the Accuracy of Pulse Estimation Using Smart Watches
PublicationThe purpose of this paper is to perform an analysis of the accuracy of the pulse estimation by comparing readings from a smartwatch with readings from medical devices. The study required writing applications that allow continuous pulse measurement. As a result, two applications were created for the smartwatch. The first one is dedicated to Android Wear devices, while the other one is compatible with Tizen watches. The next step...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Current Source Inverter Fed Drive
PublicationThis book covers three-phase and multiphase (more than three-phase) motor drives including their control and practical problems faced in the field (e.g., adding LC filters in the output of a feeding converter), are considered. The new edition contains links to Matlab®/Simulink models and PowerPoint slides ideal for teaching and understanding the material contained within the book. Readers will also benefit from the inclusion of: A...
-
Behavior of residual current devices at frequencies up to 50 kHz
PublicationThe use of residual current devices (RCDs) is obligatory in many types of low-voltage circuits. They are devices that ensure protection against electric shock in the case of indirect contact and may ensure additional protection in the case of direct contact. For the latter purpose of protection, only RCDs of a rated residual operating current not exceeding 30 mA are suitable. Unfortunately, modem current-using equipment supplied...
-
Dual drive control under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The analysis includes the behaviour of the drive system, examining the dynamic system response to speed and angle changes, and encompassing data...
-
Images revealing the effect of local femtosecond laser ablation of conductive poly(lactic acid) 3D printed electrodes
Open Research DataThe dataset reveals the images of the femtosecond laser (FSL) ablation at the surface of commercially available carbon black-filled poly(lactic acid) 3D printed electrode. The process is used for the increase of the charge transfer of this electrode in electrochemical studies.
-
Error analysis of calculating average d-q current components using Regular Sampling and Park transformation in FOC drives
PublicationIn electric drives using voltage source inverters, motor currents contain ripple component resulting from pulse-width modulated (PWM) voltage. The frequency range of the ripples is much higher than the bandwidth of current control. Therefore the control is performed on the basis of a fundamental current component, i.e. average value with the averaging time being the PWM period. In majority of cases the average current is measured...
-
The concept of a new two-stage fuse for high power pulse forming
PublicationThis manuscript introduces the concept, physical operating principle and studies on a new and unique two stage forming fuse (TSFF) with interstage spark gap commutation and presents its application for forming high power pulses of extreme parameters. The paper classifies TSFF performance and compares it with conventional single-stage forming fuses. The conclusions are supported by analytical and experimental studies in laboratory...
-
Przekształtnik prądu jako sterownik w układach napędowych z silnikami indukcyjnymi
PublicationThe circuits used for power conversion applied in drives with electric machines are classified into two groups: voltage source inverters (VSI) and current source inverters (CSI). Application of the current source inverter results in better properties of drive than application of voltage source inverter because there is no output filter. The development of power electronics and especially the IGBTs, in which on/off-times are very...
-
Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
PublicationTwo different type of electrodes, boron-doped diamond electrode (BDD) and boron-doped carbon nanowalls (B:CNW) electrode, were used for the electrochemical determination of paracetamol using the cyclic voltammetry and the differential pulse voltammetry in phosphate buffered saline, pH = 7.0. The main advantage of these electrodes is their utilization without any additional modification of the electrode surface. The peak current...
-
Space vector modulation in multilevel inverters of the servo drives of the trajectory measurements telescopes
PublicationUsing the MatLab/Simulink mathematical model of a three-phase three-level voltage inverter, the influence of the space-vector modulation (SVM) algorithm on the pulsations of the current (torque) of an AC motor in the range of low rotation speeds is considered. It is shown that the SVM of the second kind does not provide a pulsations level comparable to the pulsations of a sinusoidal pulse-width modulation (SPWM), both in the static...
-
A Wind Energy Conversion System Based on a Generator with Modulated Magnetic Flux
PublicationIn this work, the concept of an energy conversion system for wind turbines based on the modified permanent magnet synchronous generator (PMSG) is presented. In the generator, a pair of three-phase windings is used, one of which is connected in a “star” and the second in a “delta” configuration. At the outputs of both windings, two six-pulse uncontrolled (diode) rectifiers are included. These rectifiers are mutually coupled by a...
-
Derivation of motor mean phase currents in PMSM drives operating with low switching-to-fundamental frequency ratio
PublicationPulse width modulation (PWM) of inverter output voltage causes the waveforms of motor phase cur-rents to consist of distinctive ripples. In order to provide suitable feedback for the motor current con-trollers, the mean value must be extracted from the currents’ waveforms in every PWM cycle. A com-mon solution to derive the mean phase currents is to sample their value at the midpoint of a symmetrical PWM cycle. Using an assumption...
-
Electrodeposited Biocoatings, Their Properties and Fabrication Technologies: A Review
PublicationCoatings deposited under an electric field are applied for the surface modification of biomaterials. This review is aimed to characterize the state-of-art in this area with an emphasis on the advantages and disadvantages of used methods, process determinants, and properties of coatings. Over 170 articles, published mainly during the last ten years, were chosen, and reviewed as the most representative. The most recent developments...
-
Melamine-modified boron-doped diamond towards enhanced detection of adenine, guanine and caffeine
PublicationThis work describes the electrochemical method of boron-doped diamond (BDD) modification by poly-melamine to obtain organic film. The detection of adenine, guanine and caffeine were carried out by differential pulse wave voltammetry. The poly-melamine modified B-NCD electrodes exhibit excellent activity towards the electrochemical oxidation of all examined analytes. The poly-melamine modified BDD electrodes in all measurements...
-
Electrochemical determination of neurotransmitter serotonin using boron/nitrogen co-doped diamond-graphene nanowall-structured particles
PublicationElectrode fouling is a major issue in biological detection due to the adhesion of the protein itself and polymerization of biomolecules on the electrode surface, impeding the electron transfer ability and decreasing the current response. To overcome this issue, the use of anti-fouling material, especially boron-doped diamond (BDD) electrode, is an alternative way. However, the electrocatalytic activity of BDD is inadequate compared...
-
Modeling the impact of rotor movement on non-linearity of motor currents waveforms in high-speed PMSM drives
PublicationMotor current measurement techniques as well as predictive control algorithms for electric drives rely on an assumption of linear motor currents changes resulting from constant inverter output voltages. Recent research has reported that this assumption does not hold in motors with short electrical time constant, and in drives whose rotor position advances substantially during a control period. This paper proposes a simulation model...
-
Influence of Surface Modification of Titanium and Its Alloys for Medical Implants on Their Corrosion Behavior
PublicationTitanium and its alloys are often used for long-term implants after their surface treatment. Such surface modification is usually performed to improve biological properties but seldom to increase corrosion resistance. This paper presents research results performed on such metallic materials modified by a variety of techniques: direct voltage anodic oxidation in the presence of fluorides, micro-arc oxidation (MAO), pulse laser treatment,...
-
High Frequency Harmonics Emission in Smart Grids
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Low Frequency Conducted Emissions of Grid Connected Static Converters
PublicationPulse-width modulated rectifiers are nowadays commonly used for AC to DC power conversion. PWM rectification technology is very effective and allows for bidirectional power flow with the possibility of power factor improvement and low-order harmonic emission limitation. Unfortunately, employed PWM boost topology results with generation of input current harmonic distortions in a frequency range tightly correlated to modulation frequency....
-
Transient modeling in common DC link of power converters
PublicationПредмет исследования. Представлена математическая модель силовых преобразователей электропривода, питающихся от общего звена постоянного тока, на примере тяговых электроприводов карьерного самосвала БЕЛАЗ-90 мощностью 280 кВт. Модель выполнена в пакете MATLAB/Simulink. Новизна предложенной модели заключается в применении новой топологии силовой схемы для исследования работы двух инверторов, под- ключенных к одному звену постоянного...
-
The Conceptual Research over Low-Switching Modulation Strategy for Matrix Converters with the Coupled Reactors
PublicationIn this paper, different Pulse Width Modulation (PWM) strategies for operating with a low-switching frequency, a topology that combines Conventional Matrix Converters (CMCs), and Coupled Reactors (CRs) are presented and discussed. The principles of the proposed strategies are first discussed by a conceptual analysis and later validated by simulation. The paper shows how the combination of CMCs and CRs could be of special interest...
-
Pulse-Width Modulation of Power Electronic DC–AC Converter
PublicationThe Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges in the industrial drive system, as well as their components, and control, current source inverter-based drives, PWM techniques for...
-
High Performance Control of AC Drives with Matlab/ Simulink
PublicationExplore this indispensable update to a popular graduate text on electric drive techniques and the latest converters used in industry. The Second Edition of High Performance Control of AC Drives with Matlab®/Simulink delivers an updated and thorough overview of topics central to the understanding of AC motor drive systems. The book includes new material on medium voltage drives, covering state-of-the-art technologies and challenges...
-
Thermomagnetic behavior of a semiconductor material heated by pulsed excitation based on the fourth-order MGT photothermal model
PublicationThis article proposes a photothermal model to reveal the thermo-magneto-mechanical properties of semiconductor materials, including coupled diffusion equations for thermal conductivity, elasticity, and excess carrier density. The proposed model is developed to account for the optical heating that occurs through the semiconductor medium. The Moore–Gibson–Thompson (MGT) equation of the fourth-order serves as the theoretical framework...
-
Boron-Enhanced Growth of Micron-Scale Carbon-Based Nanowalls: A Route toward High Rates of Electrochemical Biosensing
PublicationIn this study, we have demonstrated the fabrication of novel materials called boron-doped carbon nanowalls (B:CNWs), which are characterized by remarkable electrochemical properties such as high standard rate constant (k°), low peak-to-peak separation value (ΔE) for the oxidation and reduction processes of the [Fe(CN)6]3–/4– redox system, and low surface resistivity. The B:CNW samples were deposited by the microwave plasma-assisted...
-
Interactions between polyphenolic antioxidants quercetin and naringenin dictate the distinctive redox-related chemical and biological behaviour of their mixtures
PublicationFood synergy concept is suggested to explain observations that isolated antioxidants are less bioactive than real foods containing them. However, mechanisms behind this discrepancy were hardly studied. Here, we demonstrate the profound impact of interactions between two common food flavonoids (individual: aglycones quercetin—Q and naringenin—N− or their glycosides rutin—R and naringin—N+ vs. mixed: QN− and RN+) on their electrochemical...
-
Design of a Shape-Memory-Alloy-Based Carangiform Robotic Fishtail with Improved Forward Thrust
PublicationShape memory alloys (SMAs) have become the most common choice for the development of mini- and micro-type soft bio-inspired robots due to their high power-to-weight ratio, ability to be installed and operated in limited space, silent and vibration-free operation, biocompatibility, and corrosion resistance properties. Moreover, SMA spring-type actuators are used for developing different continuum robots, exhibiting high degrees...
-
Conductive printable electrodes tuned by boron-doped nanodiamond foil additives for nitroexplosive detection
PublicationAn efficient additive manufacturing-based composite material fabrication for electrochemical applications is reported. The composite is composed of commercially available graphene-doped polylactide acid (G-PLA) 3D printouts and surface- functionalized with nanocrystalline boron-doped diamond foil (NDF) additives. The NDFs were synthesized on a tantalum substrate and transferred to the 3D-printout surface at 200 °C. No other electrode...
-
Measurements of radiation emission of a portable power bank with a capacity of 10400 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell (Fig. 1). The test setup was configured to measure a portable power...
-
Simulation of signal acquisition from a rotary flowmeter
Open Research DataThe dataset contains results of simulation measuring the flow of homogeneous substances by rotational flow meter: a moment of impulse at the output of flow meter, time between successive pulses, number of pulses counted from standard generator and relative error of measurement.
-
Impedance Spectra of RC Model as a Result of Testing Pulse Excitation Measurement Method Dataset
PublicationThe dataset titled Impedance spectra of RC model as a result of testing pulse excitation measurement method contains the impedance spectrum of an exemplary test RC model obtained using pulse excitation. The dataset allows presentation of the accuracy of the impedance spectroscopy measuring instrument, which uses the pulse excitation method to shorten the time of the whole spectrum acquisition.
-
Measurements of radiation emission of a portable power bank with a capacity of 2600 mAh
Open Research DataThe dataset contains the emission measurement results that are part of comprehensive tests carried out for portable power banks with different capacities. The measurements were performed in the frequency range from 30 MHz to 3 GHz using a Gigahertz Transverse Electromagnetic (GTEM) cell. The test setup was configured to measure a portable power bank...
-
High Signal Resolution Pulse Oximetry as a Prognostic Indicator of Radiotherapy Toxicity: A Pilot Study
PublicationIntroduction: Radiotherapy plays a prominent role in the multidisciplinary treatment of cancers. Despite new irradiation techniques, radiation-induced cardiotoxicity remains a leading cause of morbidity and mortality. Therefore, prognostic indicators of radiotherapy toxicity are essential. This study aimed to investigate the influence of applied radiotherapy on the pulse wave recording and thereby on...
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
The accuracy of pulse rate estimation from the sequence of face images
PublicationThe goal of this paper is to analyze the accuracy of pulse rate estimation from the sequence of face images. Simulated and real signals were used to evaluate two pulse rate estimators; one for frequency domain and the second one for time domain using the autocorrelation function. The results show that the mean difference between the reference measurements and estimated pulse rate values are about 2bpm. In the analysis of short...
-
UWB Microstrip Antennas on a Cylindrical Surfaces
PublicationConformal antennas are becoming popular due to their many advantages and possibilities of applications they offer. The advantages of using antennas with a curved surface arise not only from the possibility of integrating them with the object on which they are mounted on but also from the increase, relatively to planar antennas, of their visible angular range. The circular antenna arrays, or arrays of radiators located on the surface...
-
PULSE and ECG measurement from the hand with single fingers - elbows resting on the armrests of the chair - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Man 29 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with elbows in the air - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...
-
PULSE and ECG measurement from the hand with standing - hands resting on the device - Woman 27 age
Open Research DataThe data set presents the measurements of the pulse and the ECG signal from the hand made with the use of a proprietary measuring system based on the AD8232 chip, a set of green diode and a phototransistor made on the STM32 microcontroller. Thanks to such a constructed device, it is possible to measure the ECG signal in a non-standard way - from the...