Search results for: air monitoring
-
Jacek Namieśnik prof. dr hab. inż.
PeopleScientific discipline: chemistryRector in 2016-2019 He was born on 10 December, 1949 in Mogilno. He graduated in 1972 at the Faculty of Chemistry at Gdańsk University of Technology, obtaining a master's degree in chemical engineering. In 1972 he started working at Gdańsk University of Technology, where in 1978 he defended his doctoral thesis and in 1985 he completed his habilitation. He was appointed an associate professor in 1991...
-
Measurement of benzene concentration in urban air using passive sampling
PublicationAbstract The concentration of benzene in urban air in theTri-City area of Poland (Gdańsk-Sopot-Gdynia, andTczew) was assessed using diffusive passive samplers (Rad-iello). Samples were collected during a four-year monitoringcampaign (2007-2010) at selected monitoring stations man-aged by the Agency of Regional Air Quality Monitoring inthe Gdańsk Metropolitan Area (ARMAAG) Foundation.The performance of the passive samplers was investigatedin...
-
Electronic Noses for Indoor Air Quality Assessment
PublicationThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
Instrumental techniques used in the analysis of exhaled air
PublicationExhaled air composition changes depending on the health status of the patient, making it possible to use breath analysis for diagnosis and monitoring purposes. Despite the fact that it is not yet used in every day medical practice, it potential application could facilitate the diagnostics of various diseases such as metabolic disorders, respiratory tract and gastrointestinal diseases. Described in this paper are different application...
-
The Relationships Between BTEX, NOx, and O3 Concentrations in Urban Air in Gdansk and Gdynia, Poland
PublicationThis paper presents the results of atmospheric air quality research conducted in the areas of two shipyard cities: Gdansk and Gdynia (Poland), in the period between March and December 2011. The purpose of the research was focused on determination of benzene, toluene, ethylbenzene, and xylenes (BTEX) compounds in atmospheric air. Passive sampling technique, with Radiello® diffusive passive samplers, was used for BTEX sample collection...
-
Visual Traffic Noise Monitoring in Urban Areas
PublicationThe paper presents an advanced system for railway and road traffic noise monitoring in metropolitan areas. This system is a functional part of a more complex solution designed for environmental monitoring in cities utilizing analyses of sound, vision and air pollution, based on a ubiquitous computing approach. The system consists of many autonomous, universal measuring units and a multimedia server, which gathers, processes and...
-
Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers
PublicationPassive dosimetry — known for over a hundred years — is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of...
-
Data on bicycle traffic in Gdansk paired with weather and air quality data
Open Research DataThe file contains data on bicycle traffic registered by counting stations loacted in Gdańsk in the years 2013-2020. The data are paired with weather and air quality data from Gdansk collected for the same period. The data is described below:
-
Data on bicycle traffic in Lodz (Poland) paired with weather and air quality data
Open Research DataThe file contains data on bicycle traffic registered by counting stations loacted in Lodz in the years 2016-2019. The data are paired with weather and air quality data from Lodz collected for the same period. The data is described below:
-
Monitoring of n-butanol vapors biofiltration process using an electronic nose combined with calibration models
PublicationMalodours, by definition, are generally unpleasant, nuisance smells that are a mixture of volatile chemical compounds which can be perceptible even at low concentrations. Due to the more frequent occurrence of odour nuisance associated with the odour sensations, and thus the need to remove them from the air, deodorization techniques are commonly used. Biofiltration is one of the methods of reducing odorants in the air stream. In...
-
Interactive information and decision support system for urban and industrial air quality management based on multi-agent system
PublicationThis article presents conception of interactive information and decision support system for urban and industrial air quality management. The emphasis of the project is on real-time analysis and multi-media information, and the support of distributed and mobile clients through the Internet. The approach integrates meteorological data and forecasts, air quality and emission monitoring, dynamic 3D simulation modelling and forecasting,...
-
Biotrickling filtration of n-butanol vapors: process monitoring using electronic nose and artificial neural network
PublicationBiotrickling filtration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype combined with artificial neural network for biofiltration process monitoring in terms of reduction in n-butanol concentration and odour intensity of treated air. The study...
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Cost-Efficient Measurement Platform and Machine-Learning-Based Sensor Calibration for Precise NO2 Pollution Monitoring
PublicationAir quality significantly impacts human health, the environment, and the economy. Precise real-time monitoring of air pollution is crucial for managing associated risks and developing appropriate short- and long-term measures. Nitrogen dioxide (NO2) stands as a common pollutant, with elevated levels posing risks to the human respiratory tract, exacerbating respiratory infections and asthma, and potentially leading to chronic lung...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublicationAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Balanced Spider Monkey Optimization with Bi-LSTM for Sustainable Air Quality Prediction
PublicationA reliable air quality prediction model is required for pollution control, human health monitoring, and sustainability. The existing air quality prediction models lack efficiency due to overfitting in prediction model and local optima trap in feature selection. This study proposes the Balanced Spider Monkey Optimization (BSMO) technique for effective feature selection to overcome the local optima trap and overfitting problems....
-
Spatial aspects of urban air quality management: Estimating the impact of micro-scale urban form on pollution dispersion
PublicationUrban planning and design solutions affect urban ventilation conditions, thus mitigating the effects of atmospheric pollution. However, these findings are not being implemented in the planning practice to a sufficient extent, partly due to the lack of specific guidelines. Moreover, many urban air quality monitoring (AQM) sites have low represnentativeness and thus do not provide comprehensive data for effective urban air pollution control...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
A framework for Air Quality Management Zones - Useful GIS-based tool for urban planning: Case studies in Antwerp and Gdańsk
PublicationThere is a growing recognition of the importance of proper urban design in the improvement of air flow and pollution dispersion and in reducing human exposure to air pollution. However, a limited number of studies have been published so far focusing on the development of standard procedures which could be applied by urban planners to effectively evaluate urban conditions with respect to air quality. To fill this gap, a new approach...
-
Polybrominated diphenyl ether (PBDE) concentrations in dust from various indoor environments in Gdańsk, Poland: Prediction of concentrations in indoor air and assessment of exposure of adults
PublicationMonitoring of polybrominated diphenyl ethers (PBDEs) in indoor environments involves the determination of their concentrations in air, airborne particles, and settled dust. Each of these is a source of human exposure to PBDEs. In this study, we attempted to model PBDEs concentrations in various typical indoor environments on the basis of real PBDEs measurements in dust collected from them. The analytical procedure for determining...
-
The influence of meteorological conditions and anthropogenic activities on the seasonal fluctuations of BTEX in the urban air of the Hanseatic city of Gdansk, Poland
PublicationThe results of studies conducted in Gdansk in the period from January to December 2013 and focused on the determination of BTEX in the atmospheric air are presented. At the stage of the isolation and/or enrichment of analytes from the gaseous medium, a passive sampling technique—Radiello® diffusive passive samplers, was applied. The time-weighted average annual concentration of benzene, toluene, ethylbenzene, and total xylenes...
-
Measurement techniques for assessing the olfactory impact of municipal sewage treatment plants
PublicationThe study presents information about the measurement techniques used for the assessment of air quality in terms of the olfactory intensity resulting from the operation of municipal sewage treatment plants. Advantages and disadvantages of the measurement techniques used are presented. Sources of malodourous substance emission from sewage treatment plants were described, and the malodourous substances emitted were characterised....
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublicationThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublicationMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Perspektywy wykorzystania olfaktometrii i elektronicznego nosa w badaniach stanu środowiska
PublicationIn environmental state investigations the two approaches are dominate: field olfactometry and instrumental methods. In contradiction to classical chromatographic methods, both field olfactometry and electronic nose (e-nose) in based on the analysis of the aroma as a whole, without separating gaseous mixture (air) to individual aromatic compounds. With respect to simplicity of use and relatively short time of analysis, both systems...
-
Effects of n-butanol presence, inlet loading, empty bed residence time and starvation periods on the performance of a biotrickling filter removing cyclohexane vapors from air
PublicationThis paper presents the results of investigations on the removal of cyclohexane vapors from air using a peat-perlite packed biotrickling filter. Effects of basic process parameters i.e. IL (inlet loading) and EBRT (empty bed residence time) as well as introduction of n-butanol to the treated air stream and starvation periods on the process performance were evaluated. The results show that the introduction of hydrophilic n-butanol...
-
Will NILM Technology Replace Multi-Meter Telemetry Systems for Monitoring Electricity Consumption?
PublicationThe estimation of electric power utilization, its baseload, and its heating, light, ventilation, and air-conditioning (HVAC) power component, which represents a very large portion of electricity usage in commercial facilities, are important for energy consumption controls and planning. Non-intrusive load monitoring (NILM) is the analytical method used to monitor the energy and disaggregate total electrical usage into appliance-related...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublicationThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
PublicationThis article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane...
-
Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
PublicationMeasurement and monitoring of air quality in terms of odor nuisance is an important problem. From a practical point of view, it would be most valuable to directly link the odor intensity with the results of analytical air monitoring. Such a solution is offered by electronic noses, which thanks to the possibility of holistic analysis of the gas sample, allow estimation of the odor intensity of the gas mixture. The biggest problem...
-
Monitoring of Explosive Nitroaromatic Tetryl
Open Research DataSource data used for the publication entitled "sp2-rich Dendrite-like Carbon Nanowalls as Effective Electrode for Environmental Monitoring of Explosive Nitroaromatic Tetryl".1. SEM files2. TEM files3. XPS files4. Electrochemical measurements5. Raman files
-
AI-Driven Sustainability in Agriculture and Farming
PublicationIn this chapter, we discuss the role of artificial intelligence (AI) in promoting sustainable agriculture and farming. Three main themes run through the chapter. First, we review the state of the art of smart farming and explore the transformative impact of AI on modern agricultural practices, focusing on its contribution to sustainability. With this in mind, our analysis focuses on topics such as data collection and storage, AI...
-
Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
PublicationMonitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μ m (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors...
-
Urządzenie do wytwarzania gazowych mieszanin wzorcowych z wykorzystaniem procesu barbotażu oraz permeacji
PublicationReference gas mixtures are classified to reference materials and are mainly used for quality monitoring and identification of impurities in atmospheric air. They can be also used for calibration of measuring devices. Nowadays, there is a need to develop a new techniques for the preparation of reference gas mixtures [1, 2]. In this paper the design and the operating principles of instrument based on the use of barbotage and permeation...
-
Modelling Coarse Particulate Matter PM10 Concentration in the Tricity Area Using GIS
PublicationEnvironmental pollution is an issue of global concern, with Particulate Matter (PM) poisoning being a prime cause of lung cancer. This has led the European Commission to establish strict daily and annual PM concentration limits. The monitoring of air quality in major cities is the responsibility of European Member States. The Tricity, a 414.81 km 2 area in northern Poland, is monitored by a network of only 9 stations operated by...
-
Automatic Analysis of Trajectories of Moving Objects
PublicationOngoing monitoring is essential to providing security and safety of maritime and air operations. This paper presents the research in the area of automatic analysis of movement of unrestricted vehicles like ships and air-planes. The analysis is aimed at extraction of trajectory information, and the results can be used to identify anomalous behaviour in archived and real-time data. In this paper we focus on data acquired using the...
-
Nitrogen dioxide gas-sensing detection with GO modified CuO thin films
PublicationGas sensors have been continuously developed over the last few decades for several applications including air quality monitoring, automotive industry and recently for medical use. Gas sensors are usually based on metal oxides (MOXs), such as SnO2, TiO2, ZnO, WO3, CuO. Recently, new materials such as graphene oxide and heterostructures of graphene oxide and metal oxides are utilized for gassensing applications.
-
Systemy bezprzewodowej łączności i transmisji danych dla potrzeb bezpieczeństwa publicznego (studium stanu i rozwiązań)
PublicationW niniejszym rozdziale przedstawiono charakterystyki rozwiązań użytkowych zrealizowanych w Katedrze Systemów i Sieci Radiokomunikacyjnych Politechniki Gdańskiej. Autorzy scharakteryzowali opracowane przez zespół badawczy Katedry, systemy bezprzewodowego monitoringu zagrożeń bezpieczeństwa oraz zarządzania i sterowania infrastrukturami krytycznymi. W tym też kontekście omówiono następujące systemy i aplikacje użytkowe: − globalny...
-
APPLICATION OF ULTRAFAST GAS CHROMATOGRAPHY TO RECOGNIZE ODOR NUISANCE
PublicationPotentialities of ultrafast gas chromatography applied to periodical monitoring of odor nuisance originating from a municipal landfill have been examined. The results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during winter and summer season have been presented. The investigation was performed using ultrafast gas chromatography of Fast/Flash GC type HERACLES II by Alpha...
-
Głowice optoelektroniczne bezzałogowych środków latających
PublicationBezzałogowe środki latające nie wymagają długiego i kosztownego szkolenia załóg. Koszty ich wdrożenia są wielokrotnie niższe od załogowych środków latających. Bezzałogowe środki latające są następcami załogowych pojazdów latających rozpoznawczych i obserwacyjnych. Jednym z podstawowych elementów wyposażania bezzałogowego środka latającego jest głowica optoelektroniczna. Głowice wyposażone są w systemy rejestracji i śledzenia wskazanych...
-
Pore Water Pressure Development in Soft Soil due to Installation and Loading of Controlled Modulus Columns
PublicationExcess pore water pressure (EPWP) development and decay due to the installation and static loading tests of controlled modulus columns (CMC) in soft soil was measured with piezometers equipped with low air entry (LAE) filters and a piezocone (CPTU) equipped with a high air entry (HAE) filter. The HAE filter allows for detailed detection of EPWP in short time intervals during construction of CMC. The influence zone due to the installation...
-
Comparative field test for measurement of PM10 dust in atmospheric air using gravimetric (reference) method and b-absorption method (Eberline FH 62-1)
PublicationThe paper presents the results of a field test carried out in Gdansk region between 01-01-2010 and 31-12-2010 in order to demonstrate equivalence of the Eberline FH 62-1 sampler to the reference gravimetric method of suspended PM10 dust measurement. The differences in PM10 dust concentration provided by both methods have been discussed for different seasons of the year. A method of estimation of the correction factors/correction...
-
Passive sampling and/or extraction techniques in environmental analysis: a review
PublicationThe current state-of-the-art of passive sampling and/or extraction methods for long-term monitoring of pollutants in different environmental compartments is discussed in this review. Passive dosimeters that have been successfully used to monitor organic and inorganic contaminants in air, water, sediments, and soil are presented. The application of new approaches to the determination of pollutants at the sampling stage is discussed....
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublicationThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Kazimierz Darowicki prof. dr hab. inż.
PeopleStudia wyższe ukończyłem w czerwcu 1981 roku po zdaniu egzaminu dyplomowego i obronie pracy magisterskiej. Opiekunem pracy magisterskiej był dr hab. inż. Tadeusz Szauer. W roku 1991, 27 listopada uzyskałem stopień naukowy broniąc pracę doktorską zatytułowaną „Symulacyjna i korelacyjna analiza widm immitancyjnych inhibitowanej reakcji elektrodowej”. Promotorem pracy był prof. dr hab. inż. Józef Kubicki (Wydział Chemiczny...
-
Equivalence of on-line and reference methods for measurement of pm10 = Równoważność metod pomiarowych on-line i odniesienia stosowanych do oznaczania pm10
PublicationW badaniach nad równoważnością wyników otrzymanych za pomocą pomiaru ciągłego PM10 w stosunku do metody odniesienia stosuje się nienormatywny przewodnik unijny "Demonstration of Equivalence of Ambient Air Monitoring Methods. EC Working Group on Guidance for the Demonstration of Equivalence". W pracy omówiono sposób postępowania wg tego przewodnika. Na podstawie testu terenowego przeprowadzonego na terenie Gdańska w latach 2010-2011...
-
Selected concentration techniques for gas chromatographic analysis of environmental samples
PublicationThe paper describes the role and tasks of environmental analysis and monitoring. It emphasises the leading role played by gas chromatography, especially when coupled with suitable sample preparation. This is demonstrated by some literature evidence and mainly by the author's original work on the design of sample preparation apparatus and development of GC-based methods of determination of a wide variety of organic pollutants in...
-
Long-term comparative evaluation of an acoustic climate in selected schools before and after the acoustic treatment
PublicationThe results of long-term continuous noise measurements in two selected schools are presented in the paper. Noise characteristics were measured continuously there for approximately 16 months. Measurements started eight months prior to the acoustic treatment of the school corridors of both schools. An evaluation of the acoustic climates in both schools, before and after the acoustic treatment, was performed based on comparison of...
-
Considerations of Adaptive Digital Communications in Underwater Acoustic Channel
PublicationDown-link communication (DLC) and air transportable communication (ATAC) buoys as well as autonomous underwater vehicles (AUV) use acoustic links for gathering oceanographic data from underwater monitoring systems. The underwater channel propagation conditions are diverse in nature and require a special adaptive approach to the communication system design. The article presents a methodology for the communication systems design,...
-
RÓWNOWAŻNOŚĆ METOD POMIAROWYCH CIĄGŁYCH I ODNIESIENIA STOSOWANYCH DO OZNACZANIA PM2,5
PublicationW pracy przedstawiono wyniki testu terenowego przeprowadzonego na terenie województwa pomorskiego w okresie od 01-01-2013 do 31-12-2013 w celu wykazania równoważności wyników stężeń pyłu zawieszonego PM2,5 uzyskanych za pomocą analizatora automatycznego BAM 1020 w stosunku do wyników uzyskanych za pomocą wagowej metody odniesienia. Przedstawiono sposób określania równoważności wyników uzyskanych za pomocą analizatora i szacowania...