displaying 1000 best results Help
Search results for: MULTIFREQUENCY VOLTAGE PERTURBATION
-
Structure and the space vector modulation for a medium-voltage power-electronic-transformer based on two seven-level cascade H-bridge inverters
PublicationThis study presents the structure and the space vector pulse-width modulation (SVPWM) for power electronic transformer (PET) based on two seven-level cascade H-bridge (CHB) inverters. The DC links of CHB inverters are coupled with nine dual-active bridge (DAB) converters with medium-frequency transformers. The DC-link voltages are equalised with two methods – through the control of DAB voltages...
-
Estimation of Parameters Associated With Individual Sources of Voltage Fluctuations
Publication -
Adaptive neural voltage controller with tunable activation gain
PublicationW artykule przedstawiono model adaptacyjnego neuronowego regulatora napięcia dla turbogeneratora z nastrojonym współczynnikiem wzmocnienia funkcji przynależności. Ten model jest kombinacją klasycznego neuronowego modelu i neuronowego modelu z współczynnikiem wzmocnienia funkcji przynależności zależnym od warunków pracy obiektu.Przedstawiono, także wyniki symulacji mające na celu badania efektywności proponowanego regulatora dla...
-
Results of electrical voltage measurements in reactors - part 1
Open Research DataResults of electric voltage measurements in six reactors using various plantings. These are the results of the project: Integrated approach 3M (Macrophytes-Microbiome-Modelling) to elucidate mechanisms of bioenergy production and micropollutants transformation in Floating Treatment Wetlands combined with Microbial Fuel Cells.
-
Increasing the Utilization of dc-link Voltage of a Five-Leg VSI Based on Rotor Angle Control of Dual Induction Motors
PublicationThis paper introduces an increased utilization of the dc-link voltage of a five-leg voltage source inverter (VSI) based on the rotor flux angle control technique for dual induction motors, IM. The main purpose is to utilize additional abilities provided by a multi-motor drive system in limited operating conditions. Generally, a multi-motor drive system is widely used in electric vehicles (EVs), traction systems and in several industrial...
-
Low-Voltage Low-Power Filters with Independent ω0 and Q Tuning for Electronic Cochlea Applications
PublicationAn acoustic second-order low-pass filter is proposed for filter banks emulating the operation of a human cochlea. By using a special filter structure and an innovative quality (Q)-factor tuning technique, an independent change of the cutoff frequency (ω0) and the Q-factor with unchanged gain at low frequencies is achieved in this filter. The techniques applied result in a simple filter design with low Q-factor sensitivity to component...
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
A new concept of PWM duty cycle computation using the Barycentric Coordinates in a Three-Dimensional voltage vectors arrangement
PublicationThe paper presents a novel approach to the Pulse Width Modulation (PWM) duty cycle computing for complex or irregular voltage vector arrangements in the two (2D) and three–dimensional (3D) Cartesian coordinate systems. The given vectors arrangement can be built using at least three vectors or collections with variable number of involved vectors (i.e. virtual vectors). Graphically, these vectors form a convex figure, in particular,...
-
Electro-thermal buckling of elastically supported double-layered piezoelectric nanoplates affected by an external electric voltage
PublicationPurpose Thermal buckling of double-layered piezoelectric nanoplates has been analyzed by applying an external electric voltage on the nanoplates. The paper aims to discuss this issue. Design/methodology/approach Double-layered nanoplates are connected to each other by considering linear van der Waals forces. Nanoplates are placed on a polymer matrix. A comprehensive thermal stress function is used for investigating thermal buckling....
-
Analysis of Induced Voltages and Power Losses in High Voltage Power Cables for Selected Methods of Cables Sheaths Bonding
PublicationPower is increasingly supplied to city centres with 110 kV cable lines. This is a convenient way to supply power, and practically the only one possible in areas of dense urban development. A high-voltage cable contains a coaxial metallic sheath, in which in normal operation and in fault conditions (during short-circuits) significant line-to-earth voltages can be induced, which threatens electric shock and/or damage to the cable’s...
-
Over-Voltage Studies in Inverter Fed Induction Motor Drives
PublicationW pracy przedstawiono metodę identyfikacji pojemności pasożytniczych uzwojeń silników asynchronicznych uwzględniającą ich rozłożony charakter. Przedstawiony szerokopasmowy model obwodowy uzwojeń silnika asynchronicznego pozwala na modelowanie zjawisk przepięciowych w silnikach asynchronicznych, w szczególności zasilanych poprzez przekształtniki energoelektroniczne. Zaproponowana metoda analizy umożliwia również określanie składowych...
-
Control of voltage source inverter without dead-time effects.
PublicationW artykule zaproponowano metodę dokładnego generowania wektora napięcia o małej amplitudzie w falowniku napięcia. Zaprezentowano metodę modulacji szerokości impulsów, w której wyeliminowano koniecznosć wprowadzania czasów martwych oraz kompensacji ich wpływu na napięcie wyjsciowe przekształtnika
-
Gas sensing by thermoelectric voltage fluctuations in SnO2 nanoparticle films
PublicationPrzedstawiono eksperymentalne wyniki wykrywania gazów za pomocą badania fluktuacji napięcia termoelektrycznego w warstwie SnO2 przygotowanej z jednorodnych ziaren o średnicy 20 nm. Obserwowano fluktuacje napięcia bez zewnętrznej polaryzacji warstwy SnO2. Intensywność obserwowanych fluktuacji przekraczała 1000-krotnie intensywność szumów termicznych. Obserwowane zjawisko może byc wykorzystane do zwiększenia czułości wykrywania...
-
Output filter for voltage source inverter supplying induction motor
PublicationW artykule przedstawiono problemy związane z występowaniem składowej zerowej w falowniku napięcia. Jako rozwiązanie zastosowano filtr bierny składowej zerowej dodatkowo pełniący funkcję filtru sinusoidalnego. Filtr nie wprowadza zauważalnych przesunięć prądów i napięć na wejściu i wyjściu układu. Przedstawiono metodę doboru elementów filtru w prostokatnym układzie współrzędnych oraz wyniki badań symulacyjnych i eksperymentalnych....
-
Thermally affected parameters of the current-voltage characteristics of silicon photocell
PublicationW pracy wykazano: zależność wzrostu prądu zwarcia wskutek absorpcji dodatkowych fotonów ze wzrostem temperatury, spadek napięcia wbudowanego złącza p-n wraz ze wzrostem temperatury, wpływ temperatury na zmianę napięcia otwartego obwodu. Dodatkowo wyznaczone odpowiednie współczynniki temperaturowe porównano z wartościami wynikającymi z rozważań teoretycznych. Badano parametry elektryczne następujących elementów wykonanych z amorficznego...
-
Voltage dips reducyion with a hybrid contactless short circuit limiter.
PublicationW artykule przedstawiono działanie bezstykowego ogranicznika prądów zwarciowych w oparciu o symulację komputerową. Szczególną uwagę zwrócono na możliwość poprawy jakości dostarczanej energii, poprzez ograniczenia trwania zapadów napięcia w sieci elektroenergetycznej, dzięki zastosowaniu wyłącznika hybrydowego. Modelowanie matematyczne wykonano w programie MATLAB i PSPICE.
-
Effective perturbation signal and measurement of corrosion rate. Response to the commentary of Diard and co-workers concerning the paper in Corros. Sci. 37, 913 (1995)
Publication -
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
The scanning electron microscopy (SEM) studies of low voltage copper cables
Open Research DataThe dataset contains the scanning electron microscopy (SEM) images of the low voltage copper cables, which were studied in the article discussing the regulatory requirements for checking the electrical resistance of such cables. The cables were cut and studies in cross-section. The full results were published in:
-
Statistics of AFM current-voltage curves
Open Research DataMapping surface electrical conductivity offers enormous cognitive possibilities regarding the structure and properties of modern materials. The technique invented for this purpose (Conductive AFM) by Murrel's team and colleagues allows independent monitoring of the local conductivity of materials in correlation with the topographic profile. The mentioned...
-
Safety issues referred to induced sheath voltages in high-voltage power cables – case study
PublicationLoad currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
High power, medium voltage, modular active power filtering system
Publication -
Performance improvement method for the voltage-fed qZSI with continuous input current
Publication -
Modelling of Voltage Transformer Performance in Power System Harmonic Frequency Range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Modelling of voltage transformer performance in power system harmonic frequency range
PublicationZniekształcenia harmoniczne napięć i prądów występujące we współczesnych systemach energetycznych powodują liczne problemy pomiarowe. W referacie przedstawiono analizę właściwości przekładników napięciowych stosowanych w sieciach SN i WN w zakresie częstotliwości mierzonych zniekształceń harmonicznych. Opracowany szerokopasmowy model obwodowy został zweryfikowany symulacyjnie i eksperymentalnie. Wyniki przeprowadzonych badań potwierdzają...
-
Recreation of Voltage Fluctuation Using Basic Parameters Measured in the Power Grid
Publication -
Current-Voltage Characteristics of the Composites Based on Epoxy Resin and Carbon Nanotubes
Publication -
Control of a wind power generator in case of voltage sags in power network
PublicationW artykule poruszono problem związany ze sposobem sterowania generatorem elektrowni wiatrowej w przypadku wystąpienia po stronie sieci zapadów napięcia.Jako generator wykorzystano maszynę dwustronnie zasilaną której stojan podłączono bezpośrednio do sieci natomiast wirnik zasilano poprzez kaskadę przekształtników. Wystąpienie spadku lub zapadu napięcia sieci w przypadku pracy tego typu generatora może doprowadzić do uszkodzenia...
-
Critical evaluation of resonaut gc voltage link inventures for electrical drives.
PublicationPrzedstawiono wyniki modelowania i symulacji falowników z centralnym obwodem rezonansowym dla zastosowań w napędzie elektrycznym. Porównano struktury ukladów z rezonansowym równoległym obwodem pośredniczącym o ograniczonej wartości szczytowej i uasi-rezonansowych. Dla potrzeb projektowania tych układów, wobec przeciwstawnych funkcji celu dokonano ich wielokrytycznej oceny.
-
A versatile analog CMOS cell: voltage - buffer /current - conveyor/ multiplier
PublicationW pracy przedstawiono koncepcję uniwersalnej komórki analogowej przeznaczonej dla programowalnych układów analogowych (FPAA). Komórka może pełnić funkcję bufora napięciowego, konwjora prądowego lub mnożnika analogowego. Układ przesymulowano w technologii CMOS 2 ćm.
-
Effect of contactless hybrid current limiter on voltage dips in power system
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Design of synchronous generator voltage regulator based on H control theory
PublicationSystemy dużej mocy są z reguły systemami o dużej nieliniowości. Wynika to z dynamiki takiego obiektu jak również jego konfiguracji itd. Istnieje wiele metod umożliwiających sterowanie czy testowanie zaprojektowanych generatorów. W artykule analizowana jest metoda projektowania regulatora napięcia w oparciu o H. Wyniki symulacji są zadowalające, ponieważ tak zaprojektowany regulator lepiej tłumi kołysania elektromechaniczne niż...
-
Dynamic current-voltage characteristics of dielectrics with extremely low heat conductivity
PublicationZaprezentowano teoretyczny opis metody dynamicznych charakterystyk prądowo-napięciowych w przypadku znacznego gradientu temperatury w ciałach stałych o przewodności jonowej. Otrzymano rozwiązania równania transportu oraz równania charakterystyk, odnoszące się do ruchu cienkiej warstwy nośników ostałej grubości oraz warstwy rozszerzającej się. Podano także przybliżone wyrażenia opisujące czas przelotu nośników. Wyniki zweryfikowano...
-
Effect of contactless hybrid current limiter on voltage dips in power system.
PublicationW referacie przedstawiono działanie hybrydowego niskonapięciowego ogranicznika prądu zwarciowego, składającego się z ultraszybkiego bezpiecznika, tranzystora mocy i warystora. W szczególności omówiono możliwości polepszenia jakości dostarczanej do odbiorców energii elektrycznej. Zastosowanie hybrydowego ogranicznika prądu znacznie ogranicza czasy trwania zapadów napięcia w systemie elektroenergetycznym. Obliczenia wykonano przy...
-
Self-Tuning Dead-Time Compensation Method for Voltage-Source Inverters
PublicationPrzedstawiono nową, kompleksową metodę kompensacji zniekształceń napięcia wyjściowego falownika z modulacją szerokości impulsów. Proponowana metoda umożliwia automatyczne dopasowanie parametrów charakterystyki kompensacyjnej do aktualnej konfiguracji falownika i obciążenia, np. po zmianie przewodu łączącego falownik z obciążeniem. Adaptacja do nowych warunków polega na dostrajaniu wartości parametrów zależności opisującej napięcie...
-
Selected Technical Requirements for Photovoltaic Plant Interconnection with a Medium Voltage Grid
PublicationThe article discusses some selected technical requirements, which according to these authors should be recognised and met by photovoltaic power plants connected to national distribution grids in the context of their likely development. This development today is limited, since Polish legislation has not implemented the relevant EU Directive [8]. The study points out the purposefulness of incorporating the necessary requirements...
-
Energy losses reduction in the medium voltage cable line – case study
PublicationThe paper presents an analysis of energy losses in a power cable system, which is composed of two 30 kV cable lines. This cable system is located at the seaside holiday area, so the load profile during a year is specific. Energy losses related to reactive power transmission, as well as to currents induced in the sheaths of the cables, are subject to analysis. Measurements were made in the system in order to prepare a computer model...
-
The photocurrent quantum efficiency dependence on the applied voltage in organic solar cells
PublicationWe demonstrate that our recently reported model (Szmytkowski 2007 J. Phys. D: Appl. Phys. 40 3352) of the photocurrent quantum efficiency in organic semiconductors explains the external quantum efficiency dependence on the electric field in organic solar cells. This effect can be explained by taking into account that the photogeneration of charge carriers occurs via the electron-hole pair dissociation and the space charge effects...
-
The effect of cable duct diameter on the ampacity of high-voltage power cables
PublicationThe ampacity of power cables depends, among others, on the conditions of heat dissipation from the cable to the environment. Cables are usually laid directly in the ground, but in some sections, they may be placed in ducts, which adversely affects the ampacity of the cable line. The paper presents heat transfer phenomena for cables installed in pipe-type ducts filled with air. The effect of cable duct diameter on this ampacity...
-
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublicationThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
The Finite Elements Method application to assesment the impact of turbulence generated by wind turbines on their lacation inclose proximity of overhead high voltage power transmissionlines
PublicationThe paper presents selected aspects of construction of wind turbines location concerning aerodynamic impact on power lines. Reaserch is based on the source data concerning the aerodynamic impact of a wind farm consisting of 8 turbines and 400 kV power line, an analysis of the possibility of wind farm locating in the immediate vicinity of the line was carried out. There are serious problems with locating higher capacity wind farms...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...