Filters
total: 2183
-
Catalog
- Publications 1530 available results
- Journals 30 available results
- Conferences 11 available results
- Publishing Houses 1 available results
- People 111 available results
- Inventions 1 available results
- Projects 12 available results
- Research Teams 2 available results
- Research Equipment 2 available results
- e-Learning Courses 35 available results
- Events 1 available results
- Open Research Data 447 available results
displaying 1000 best results Help
Search results for: sensory%20gazow
-
Monitoring of odour nuisance on the adjacent areas to the landfill using fast GC and sensory analysis
PublicationThe paper shows the results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during August and September period have been presented. The studies was conducted by the use of Fast GC HERACLES II from AlphaMOS company and sensory analysis. About 86% of the atmospheric air samples ollected were classified correctly using PCA and LDA. Based on a classification of the atmospheric...
-
Development of novel optoelectronic sensory structures utilising colour centres in nanodiamonds and their interactions with analytes
PublicationThe goal of this dissertation was to develop and assess surface modifications of fluorescent nanodiamonds (NDs) for optical sensing. Three modification routes were tested, each aimed at a different application. Modification with poly-L-lysine (pLys) was verified for optical sensing of pH via an interrelationship between electrically negative (NV¯) and neutral (NV0) nitrogen-vacancy centres. Immobilisation of Ochratoxin A (OTA),...
-
Optical Diffraction Strain Sensor Prepared by Interference Lithography
Publication -
<title>LabWindows: tool and environment for sensor design</title>
Publication -
New Manufacturing Method Of Sensor Oriented Optical Fibers
Publication -
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
Pattern matching localization in ZigBee wireless sensor networks.
PublicationLokalizacja typu Pattern matching w sieciach sensorów bezprzewodowych ZigBee.Prezentacja metod implementacji algorytmów lokalizacji. Praktyczne zastosowanie i testowanie lokalizacji sieci ZigBee.
-
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
Influence of Humidity on Parameters of Amperometric Sensor with Nafion Membrane
PublicationPrzedstawiono wyniki badań wpływu umiarkowanych i wysokich wilgotności powietrza na sygnał, czułość i czas odpowiedzi prototypowego czujnika ditlenku siarki ze złotą elektrodą pracującą, próżniowo napyloną na powierzchnię membrany nafionowej. Zaprezentowano także wyniki badań impedancyjnych w zakresie potencjałów, w którym mechanizm utleniania ditlenku siarki jest kontrolowany aktywacyjnie i dyfuzyjnie. Parametry odpowiadające...
-
Wave propagation in a sensor/actuator diffusion bond model
Publication -
Analytical characteristics of a new amperometric sulfur dioxide sensor
PublicationZaprojektowano i skonstruowano wyposażony w układ trójelektrodowy amperometryczny czujnik ditlenku siarki. Elektroda pracująca czujnika była napylona bezpośrednio na powierzchnię membrany. Zbadano charakterystyki czujnika z membranami z mikroporowatego Teflonu oraz Nafionu. Porównano parametry statyczne i dynamiczne tych czujników wypełnionych roztworami elektrolitów wewnętrznych, zawierających dodatek dimetylosulfotlenku.
-
an intelligent image processing sensor - the algorithm and the hardware implementation
PublicationW artykule przedstawiono algorytm przeznaczony do rozpoznawania obiektów ruchomych w obrazie do celu analizy ruchu pojazdów. Algorytm został zrealizowany w układzie FPGA.Ang.: This paper describes the idea and theimplementation of the robust algorithm dedicated toextraction of moving vehicles from real-time cameraimages for the evaluation of traffic parameters, suchas the number of vehicles, their direction of movementand their...
-
Localization in wireless sensor networks based on zigbee platform
PublicationW artykule porównano dwie różne metody lokalizacji w sieciach sensorów bezprzewodowych. Jedną z metod jest implementacja sprzętowa algorytmu w układzie nadawczo odbiorczym CC2431. Drugą metodą jest implementacja programowa. Wyniki testów przeprowadzonych na otwartym terenie oraz w pomieszczeniach zamkniętych zostały przedstawione i porównane w pracy.
-
Electrical properties of polymer humidity sensor based on polyethyleneimine.
PublicationW pracy przedstawiono wyniki badań amperometrycznych właściwości czujników wilgotności na bazie PEI. Pokazano, że przepływ prądu jest wynikiem reakcji elektrodowej na anodzie.
-
Targed tracking with adaptive fusionof multiple sensor measurements.
PublicationW pracy przedstawiono metodę adaptacyjnej selekcji pomiarów z wielu radarów wykorzystywanych w procesie integracji pomiarów dla śledzenia obserwowanego obiektu. W przypadku dużego zróżnicowania dokładności pomiarów pochodzących z różnych radarów, rezultaty integracji pomiarów nie różnią się znacząco od wyników śledzenia opartego na pomiarach z najbardziej dokładnego źródła.
-
White-light interferometric temperature sensor for biomedical diagnostic.
PublicationW artykule opisano opracowany model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry-Perot wykorzystującego interferencję światła białego przeznaczonego do zastosowań biomedycznych. Analizowano czujnik wykonany ze światłowodu wielomodowego o skokowym profilu współczynnika załamania oraz ze światłowodu monomodowego. Zasadniczym celem był dobór parametrów mający na celu uzyskania maksymalnej widzialności...
-
Trajectories detection in a distributed multi-sensor tracking system
PublicationW pracy rozważono problem śledzenia obiektów poruszających się za pomocą rozproszonego systemu wieloczujnikowego. Głównym zadaniem systemu śledzenia jest detekcja i estymacja trajektorii obiektów poruszających się w obserwowanej przestrzeni. Trajektoria obiektu to ciąg estymat kinematycznego stanu obiektu, jego pozycji, prędkości, itp. Klasyczne systemy śledzenia oparte są na filtrze Kalmana korzystającym z danych z pojedynczego...
-
Influence of operation temperature instability on gas sensor performance
PublicationGas sensors based on the semiconducting metal-oxides, such as SnO2, have been found to be very useful for detecting a wide range of gases. The reversible interactions of the gas with the surface of the sensing layer made of semiconducting metal-oxides are responsible for changes of sensor resistance which is usually used as a measure of sensor response. Semiconductor gas sensors are commercially available and applied in numerous...
-
The passive operating mode of the linear optical gesture sensor
PublicationThe study evaluates the influence of natural light conditions on the effectiveness of the linear optical gesture sensor, working in the presence of ambient light only (passive mode). The orientations of the device in reference to the light source were modified in order to verify the sensitivity of the sensor. A criterion for the differentiation between two states - "possible gesture" and "no gesture" - was proposed. Additionally,...
-
Planar Microwave Bragg Reflector Resonant Dielectric Sensor
PublicationIn this paper, a periodic structure is used to design a microwave Bragg reflector with the help of hexagonal lattice, which provides a 5 GHz wide stopband between the low-pass band with cut-off frequency 2.6 GHz and the bandpass response with start and stop frequency 7.8 GHz and 10.5 GHz, respectively. A defect in lattice allows passing a narrowband signal at 6 GHz which is found, from the dispersion relation, to be in the region...
-
Localization of sound sources with dual acoustic vector sensor
PublicationThe aim of the work is to estimate the position of sound sources. The proposed method uses a setup of two acoustic vector sensors (AVS). The intersection of azimuth rays from each AVS should indicate the position of a source. In practice, the result of position estimation using this method is an area rather than a point. This is a result of inaccuracy of the individual sensors, but more importantly, of the influence of a source...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
Determination of the Vehicles Speed Using Acoustic Vector Sensor
PublicationThe method for determining the speed of vehicles using acoustic vector sensor and sound intensity measurement technique was presented in the paper. First, the theoretical basis of the proposed method was explained. Next, the details of the developed algorithm of sound intensity processing both in time domain and in frequency domain were described. Optimization process of the method was also presented. Finally, the proposed measurement...
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationIn this paper performance of an electrocatalytic sensor in presence of chlorine is investigated. Presented studies concern sensor prepared in ceramic technology based on NASICON as a solid electrolyte with two round shaped platinum electrodes. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Semi complex navigation with an active optical gesture sensor
PublicationThis paper presents the methods of diversified touchless interactions between a user and a mobile platform utilizing the optical gesture sensor. The sensor uses 8 photodiodes to measure the reflected light in the active mode (using embedded LEDs) or it measures shadows caused by fingers in the passive mode. Several algorithms were implemented: automatic mode switching, adaptive illumination level compensation, resolution improvements...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Distributed Trust Management Model for Wireless Sensor Networks
Publication -
Potentiometric Oxygen Sensor with Solid State Reference Electrode
PublicationThe concentration or the partial pressure of oxygen in an environment can be determined using different measuring principles. For high temperature measurements of oxygen, ceramic-based sensors are the most practical. They are simple in construction, exploration and maintenance. A typical oxygen potentiometric sensor consists of an oxygen ion conducting solid electrolyte and two electrodes deposited...
-
The secure transmission protocol of sensor Ad Hoc network
PublicationThe paper presents a secure protocol of radio Ad Hoc sensor network. This network operates based on TDMA multiple access method. Transmission rate on the radio channel is 57.6 kbps. The paper presents the construction of frames, types of packets and procedures for the authentication, assignment of time slots available to the node, releasing assigned slots and slots assignment conflict detection.
-
Investigation of electrocatalytic gas sensor properties in presence of chlorine
PublicationProperties of sensor based on Nasicon with two round shaped platinum electrodes are investigated. Influence of different chlorine concentrations on the sensor response is presented. Measurements in different temperatures have been performed in order to determine optimal sensor working temperature.
-
Detection of Water on Road Surface with Acoustic Vector Sensor
PublicationThis paper presents a new approach to detecting the presence of water on a road surface, employing an acoustic vector sensor. The proposed method is based on sound intensity analysis in the frequency domain. Acoustic events, representing road vehicles, are detected in the sound intensity signals. The direction of the incoming sound is calculated for the individual spectral components of the intensity signal, and the components...
-
Optimal placement of IMU sensor for the detection of children activity
PublicationIn this paper an investigation to determine the optimal placement of IMU sensors for the purpose of children characteristic activity detection is presented. The article compares four different placement of two IMU sensors on human body. Ten healthy volunteers participated within the study. Data were collected firstly from two wireless 9-axial IMU sensors placed at the left and right wrists, then sensors were placed at lower back...
-
Photonic sensor to detect rapid changes in CRP levels
PublicationOne of the most important biomarkers used to determine inflammation is C-reactive protein (CRP). Its level, when it is within the range that does not define inflammation, informs about the risk of cardiovascular events. If the norm is exceeded and inflammation is detected in the body, CRP level can increase 1000 times within a few hours. The type of infection can also be determined based on the level of elevated CRP. All this makes...
-
Temperature Fiber-Optic Sensor with ZnO ALD Coating
PublicationThis study presents a microsphere-based fiber-optic sensor with a ZnO Atomic Layer Deposition (ALD) coating thickness of 100 nm for temperature measurements. Metrological properties of the sensor were investigated over the temperature range of 100 °C to 300 °C, with a 10 °C step. An interferometric signal is used to control whether the microstructure is whole. Spectrum shift of a reflected signal is used to ascertain changes in...
-
Wireless data transmission for fiber optical sensor system
PublicationW artykule opisano możliwość wykorzystania bezprzewodowego systemu transmisji danych do transmisji sygnałów z czujników światłowodowych.
-
A model of the response of the MGS-6 gravity sensor to tilting
PublicationThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
Luminescent Polymer Optical Fibre Sensor for Temperature Measurement
Publication -
Active glasses as the luminescent sources of radiation for sensor applications
Publication -
Bezprzewodowe zasilanie sensorów medycznych
PublicationW artykule przedstawiono problematykę bezprzewodowego zasilania miniaturowych sensorów medycznych. Przedyskutowano specyfikę bezprzewodowej transmisji mocy elektrycznej do sensorów, zwracając uwagę na potrzebę stosowania tej formy zasilania oraz na ograniczenia wynikające z limitów gęstości mocy dopuszczalnej dla żywych organizmów, w szczególności dla człowieka. Zaproponowano nowe podejście do bezprzewodowego przesyłu mocy wykorzystujące...
-
On Invariants of Fluid Mechanics Tensors
PublicationThis paper presents physical interpretations of the first and second invariants of tensors of fluid mechanics. Some examples of elementary applications and meanings are also given.
-
Bezprzewodowe zasilanie sensorów medycznych
PublicationW artykule przedstawiono problematykę bezprzewodowego zasilania miniaturowych sensorów medycznych. Przedyskutowano specyfikę bezprzewodowej transmisji mocy elektrycznej do sensorów, zwracając uwagę na potrzebę stosowania tej formy zasilania oraz na ograniczenia wynikające z limitów gęstości mocy dopuszczalnej dla żywych organizmów, w szczególności dla człowieka. Zaproponowano nowe podejście do bezprzewodowej transmisji mocy wykorzystujące...
-
High resolution optical time-domain reflectometry using sub-picosecond laser sources
PublicationPrzedstawiono działanie sensorów światłowodowych wykorzystujących reflektometrię optyczną w dziedzinie czasu. Omówiono ograniczenia możliwości pomiarowych tej klasy sensorów wynikające z zastosowania w nich reflektometrów światłowodowych zaprojektowanych do zastosowań w telekomunikacji. Zaprezentowano sensory wykorzystujące specjalizowane reflektometry o dużej rozdzielczości. Przedstawiono koncepcję sensora wykorzystującego dwa...
-
Horizontally-split-drain MAGFET - a highly sensitive magnetic field sensor
PublicationWe propose a novel magnetic field sensitive semiconductor device, viz., Horizontally-Split-Drain Magnetic-Field Sensitive Field-Effect Transistor (HSDMAGFET) which can be used to measure or detect steady or variable magnetic fields. Operating principle of the transistor is based on one of the galvanomagnetic phenomena and a Gradual Channel Detachment Effect (GCDE) and is very similar to that of Popovic and Baltes's SDMAGFET. The...
-
Hidden Tensor Structures
PublicationAny single system whose space of states is given by a separable Hilbert space is automatically equipped with infinitely many hidden tensor-like structures. This includes all quantum mechanical systems as well as classical field theories and classical signal analysis. Accordingly, systems as simple as a single one-dimensional harmonic oscillator, an infinite potential well, or a classical finite-amplitude signal of finite duration...
-
Sinusoidal Control of a Brushless DC Motor with Misalignment of Hall Sensors
Publication -
A Family Of Multicore 0ptical Fibre Based Sensors And Instrumentation Systems
Publication -
Multichannel taste sensors with lipid, lipid like – polymer membranes
Publication -
Tuning the sumanene receptor structure towards the development of potentiometric sensors
Publication