Filters
total: 11631
-
Catalog
- Publications 8849 available results
- Journals 249 available results
- Conferences 119 available results
- Publishing Houses 1 available results
- People 189 available results
- Projects 19 available results
- Laboratories 1 available results
- Research Teams 1 available results
- Research Equipment 2 available results
- e-Learning Courses 268 available results
- Events 12 available results
- Open Research Data 1921 available results
displaying 1000 best results Help
Search results for: AIR QUALITY MONITORING, NITROGEN DIOXIDE, LOW-COST SENSORS, SENSOR CALIBRATION, ARTIFICIAL INTELLIGENCE
-
On Memory-Based Precise Calibration of Cost-Efficient NO2 Sensor Using Artificial Intelligence and Global Response Correction
PublicationNitrogen dioxide (NO2) is a prevalent air pollutant, particularly abundant in densely populated urban regions. Given its harmful impact on health and the environment, precise real-time monitoring of NO2 concentration is crucial, particularly for devising and executing risk mitigation strategies. However, achieving precise measurements of NO2 is challenging due to the need for expensive and cumbersome equipment. This has spurred...
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublicationDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...
-
Field Calibration of Low-Cost Particulate Matter Sensors Using Artificial Neural Networks and Affine Response Correction
PublicationDue to detrimental effects of atmospheric particulate matter (PM), its accurate monitoring is of paramount importance, especially in densely populated urban areas. However, precise measurement of PM levels requires expensive and sophisticated equipment. Although low-cost alternatives are gaining popularity, their reliability is questionable, attributed to sensitivity to environmental conditions, inherent instability, and manufacturing...
-
Statistical Data Pre-Processing and Time Series Incorporation for High-Efficacy Calibration of Low-Cost NO2 Sensor Using Machine Learning
PublicationAir pollution stands as a significant modern-day challenge impacting life quality, the environment, and the economy. It comprises various pollutants like gases, particulate matter, biological molecules, and more, stemming from sources such as vehicle emissions, industrial operations, agriculture, and natural events. Nitrogen dioxide (NO2), among these harmful gases, is notably prevalent in densely populated urban regions. Given...
-
Efficient Calibration of Cost-Efficient Particulate Matter Sensors Using Machine Learning and Time-Series Alignment
PublicationAtmospheric particulate matter (PM) poses a significant threat to human health, infiltrating the lungs and brain and leading to severe issues such as heart and lung diseases, cancer, and premature death. The main sources of PM pollution are vehicular and industrial emissions, construction and agricultural activities, and natural phenomena such as wildfires. Research underscores the absence of a safe threshold for particulate exposure,...
-
Sensors and System for Vehicle Navigation
PublicationIn recent years, vehicle navigation, in particular autonomous navigation, has been at the center of several major developments, both in civilian and defense applications. New technologies, such as multisensory data fusion, big data processing, or deep learning, are changing the quality of areas of applications, improving the sensors and systems used. Recently, the influence of artificial intelligence on sensor data processing and...
-
Features extraction from the electrocatalytic gas sensor responses
PublicationOne of the types of gas sensors used for detection and identification of toxic-air pollutant is an electrocatalytic gas sensor. The electrocatalytic sensors are working in cyclic voltammetry mode, enable detection of various gases. Their response are in the form of I-V curves which contain information about the type and the concentration of measured volatile compound. However,...
-
Electrocatalytic Gas Sensor with Reference Layer
PublicationThis paper presents studies of gas sensors prepared in ceramic technology with Nasicon as a solid electrolyte. Sensors work in the voltammetric mode thus based on the excitation of a sensor with a periodic potential signal while current response is recorded. The main aim is to investigate a Bi8Nb2O17 reference layer influence on sensor properties. Sensors I-V characteristics in different concentration of nitrogen dioxide have been...
-
Sensors and Sensor’s Fusion in Autonomous Vehicles
PublicationAutonomous vehicle navigation has been at the center of several major developments, both in civilian and defense applications. New technologies such as multisensory data fusion, big data processing, and deep learning are changing the quality of areas of applications, improving the sensors and systems used. New ideas such as 3D radar, 3D sonar, LiDAR, and others are based on autonomous vehicle revolutionary development. The Special...
-
Identification of volatile compounds based on the electrocatalytic gas sensor responses
PublicationMeasured response in case of electrocatalytic gas sensors is in form of a voltamperometric characteristic. Current-voltage (I-V) response shape depends on the gas type and its concentration. Such response contains significantly more information comparing with typical electrochemical sensors, but is quite difficult to analyze. When I-V curve contains current peaks, position of such peaks can be used...
-
Chemiresistive gas sensors based on carbon nanotubes - fabrication and application
PublicationMany types of sensors have been invented to identify and quantify chemical contamination in the gas phase. Sensors based on carbon nanotubes are particularly attractive because of their wide range of applicaions and potential use in electronic nose that can be controlled using algorithms of Artificial Intelligence. Sensor functions, fabrication and selected applications are reviewed and discussed with focus on chemiresistors. Drawbacks...
-
Electrocatalytic gas sensor with reference layer
PublicationIn recent years electrochemical gas sensors based on solid state electrolytes have been intensively developed. They are easy to obtain, use and relative durable. Nasicon is one of the most promising materials, which have been used in construction of gas sensors. Most of these devices work in potentiometric or amperometric mode. However, some works are dedicated to sensors working in electrocatalytic mode. Principle of operation...
-
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublicationA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
Efficiency of linear and non-linear classifiers for gas identification from electrocatalytic gas sensor
PublicationElectrocatalytic gas sensors belong to the family of electrochemical solid state sensors. Their responses are acquired in the form of I-V plots as a result of application of cyclic voltammetry technique. In order to obtain information about the type of measured gas the multivariate data analysis and pattern classification techniques can be employed. However, there is a lack of information in literature about application of such...
-
Extraction and evaluation of gas-flow-dependent features from dynamic measurements of gas sensors array
PublicationGas analyzers based on gas sensors are the devices which enable recognition of various kinds of volatile compounds. They have continuously been developed and investigated for over three decades, however there are still limitations which slow down the implementation of those devices in many applications. For example, the main drawbacks are the lack of selectivity, sensitivity...
-
EVALUATION OF THE NO2CONCENTRATION PREDICTION POSSIBILITYBASED ON STATIC AND DYNAMIC RESPONSES OF TGS SENSORSAT CHANGING HUMIDITY LEVELS
PublicationThe commercially available metal-oxide TGS sensors are widely used in many applications due to thefact that they are inexpensive and considered to be reliable. However, they are partially selective and theirresponses are influenced by various factors,e.g. temperature or humidity level. Therefore, it is importanttodesign a proper analysis system of the sensor responses. In this paper, the results of examinations of eightcommercial...
-
Electronic nose algorithm design using classical system identification for odour intensity detection
PublicationThe two elements considered crucial for constructing an efficient environmental odour intensity monitoring systems are sensors and algorithms typically addressed to as electronic nose sensor (e-nose). Due to operational complexity of biochemical sensors developed in human bodies algorithms based on computational methods of artificial intelligence are typically considered superior to classical model based approaches in development...
-
An electronic nose for quantitative determination of gas concentrations
PublicationThe practical application of human nose for fragrance recognition is severely limited by the fact that our sense of smell is subjective and gets tired easily. Consequen tly, there is considerable need for an instrument that can be a substitution of the human sense of smell. Electronic nose devices from the mid 1980s are used in growing number of applications. They comprise an array of several electrochemical gas sensors...
-
Accurate Lightweight Calibration Methods for Mobile Low-Cost Particulate Matter Sensors
PublicationMonitoring air pollution is a critical step towards improving public health, particularly when it comes to identifying the primary air pollutants that can have an impact on human health. Among these pollutants, particulate matter (PM) with a diameter of up to 2.5 μ m (or PM2.5) is of particular concern, making it important to continuously and accurately monitor pollution related to PM. The emergence of mobile low-cost PM sensors...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublicationIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
Evaluation of the Commercial Electrochemical Gas Sensors for the Monitoring of CO in Ambient Air
PublicationAir pollution is a growing concern of civilized world, which has a significant impact on human health and the environment. Recent studies highlight that the exposure to polluted air can increase the incidence of diseases and deteriorate the quality of life. Hence, it is necessary to develop tools for real-time air quality monitoring. For air pollution monitoring a wide range of stationary gas and particulate analysers can be used....
-
SENSORS
Journals -
Investigation of sensing mechanism of Nasicon electrocatalytic sensors in nitrogen dioxide and ammonia
PublicationIn this paper a sensing mechanism of Nasicon electrocatalytic sensor in nitrogen dioxide and ammonia is investigated. Both gases are environmentally hazardous and contain nitrogen atom in the molecule. However, it seems that their sensing mechanism in electrocatalytic sensor could be totally different. Namely, the maximum sensitivity for each gas was obtained at different temperatures. Also, different auxiliary layers are formed...
-
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Open Research DataThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...
-
Low cost electrochemical sensor module for measurement of gas concentration
PublicationThis paper describes a low cost electrochemical sensor module for gas concentration measurement. A module is universal and can be used for many types of electrochemical gas sensors. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 is used. The proposed equipment will be used as a component of electronic nose system employed for classifying and distinguishing...
-
The sensors-based artificial intelligence Train Control and Monitoring System (TCMS) for managing the railway transport fleet
PublicationRailways deliver a safe and sustainable form of transport and are typically pointed as one the safest form of transportation. Nevertheless, train accidents still happen, and when they happen, the consequences concern serious fatalities and injuries. Since every case is unique, the most frequent causes of train accidents are mechanical derailments, failures, as well as human errors and ignorance. In order to mitigate the risks posed...
-
Sztuczny sensor smaku a zmysł smaku
PublicationOmówiono klasy smaku i działanie zmysłu smaku, który odgrywa ogromną rolę w ocenie jakości żywności metodami organoleptycznymi. Metody te nie są w pełni obiektywne, stąd poszukuje się sztucznego sensora smaku. Przedstawiono szereg rozwiązań prowadzących do opracowania sensora smaku na większą skalę. Omówiono wybrane potencjometryczne i woltamperometryczne sensory smaku, a także ich handlowe modele.
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublicationThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Optimised Allocation of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised placement of the hard quality sensors in Drinking Water Distribution Systems for robust quality monitoring is formulated. Two numerical algorithms to solve the problem are derived. The optimality is meant as achieving a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm. The robust estimation algorithm recently developed...
-
Current air quality analytics and monitoring: A review
PublicationThis review summarizes the different tools and concepts that are commonly applied in air quality monitoring. The monitoring of atmosphere is extremely important as the air quality is an important problem for large communities. Main requirements for analytical devices used for monitoring include a long period of autonomic operation and portability. These instruments, however, are often characterized by poor analytical performance....
-
Calibration of acoustic vector sensor based on MEMS microphones for DOA estimation
PublicationA procedure of calibration of a custom 3D acoustic vector sensor (AVS) for the purpose of direction of arrival (DoA) estimation, is presented and validated in the paper. AVS devices working on a p-p principle may be constructed from standard pressure sensors and a signal processing system. However, in order to ensure accurate DoA estimation, each sensor needs to be calibrated. The proposed algorithm divides the calibration process...
-
On Rapid Design Optimization and Calibration of Microwave Sensors Based on Equivalent Complementary Resonators for High Sensitivity and Low Fabrication Tolerance
PublicationThis paper presents the design, optimization, and calibration of multivariable resonators for mi-crowave dielectric sensors. An optimization technique for circular complementary split ring reso-nator (CC-SRR) and square complementary split ring resonator (SC-SRR) is presented to achieve the required transmission response in a precise manner. The optimized resonators are manufac-tured using a standard photolithographic technique...
-
Electrocatalytic nitrogen dioxide sensor.
PublicationOpisano konstrukcję i właściwości elektrokatalitycznego czujnika gazów na bazie domieszkowanego samarem tlenku ceru. Pomiary przeprowadzono w mieszaninie syntetycznego powietrza i dwutlenku azotu. Kształt odpowiedzi prądowo - napięciowej zależy od stężenia NO2.
-
A Surrogate-Assisted Measurement Correction Method for Accurate and Low-Cost Monitoring of Particulate Matter Pollutants
PublicationAir pollution involves multiple health and economic challenges. Its accurate and low-cost monitoring is important for developing services dedicated to reduce the exposure of living beings to the pollution. Particulate matter (PM) measurement sensors belong to the key components that support operation of these systems. In this work, a modular, mobile Internet of Things sensor for PM measurements has been proposed. Due to a limited...
-
Optimised Robust Placement of Hard Quality Sensors for Robust Monitoring of Quality in Drinking Water Distribution Systems
PublicationA problem of optimised robust placement of the hard quality sensors in Drinking Water Distribution Systems under several water demand scenarios for robust quality monitoring is formulated. Numerical algorithms to solve the problem are derived. The optimality is meant as achieving at the same time a desired trade off between the sensor capital and maintenance costs and resulting robust estimation accuracy of the monitoring algorithm...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
A calibration model for gas sensor array in varying environmental conditions
PublicationAbstract: Gas-analyzing systems based on gas sensors, commonly referred to as electronic noses, are the systems which enable the recognition of volatile compounds in their working environment and provide the on-line results of analysis. The most commonly used type of sensors in such systems is semiconductor gas sensors. They are considered to be the most reliable in the long-term applications (more than 1 year), however,...
-
LOW COST MEASUREMENT MODULE FOR MATRIX OF AMPEROMETRIC GAS SENSOR
PublicationThis paper describes an amperometric sensor module for gas concentration measurement. A module can be used for many types of electrochemical gas sensors without major hardware changes. Device is based on AVR ATmega8 microcontroller. As signal processing circuit a specialized integrated circuit LMP9l000 configurable via I2C interface is used. The concept of a measuring system composed of several modules dedicated for a gas sensors...
-
Measurement Automation Monitoring
Journals -
Identification of defected sensors in an array of amperometric gas sensors
PublicationPurpose Amperometric gas sensors are commonly used in air quality monitoring in long-term measurements. Baseline shift of sensor responses and power failure may occur over time, which is an obstacle for reliable operation of the entire system. The purpose of this study is to check the possibility of using PCA method to detect defected samples, identify faulty sensor and correct the responses of the sensor identified as faulty. Design/methodology/approach In...
-
Ireneusz Czarnowski Prof.
PeopleIRENEUSZ CZARNOWSKI is a graduate of the Faculty of Electrical Engineering at Gdynia Maritime University. He gained a doctoral degree in the field of computer science at Poznan University of Technology and a postdoctoral degree in the field of computer science at Wroclaw University of Science and Technology. Since 1998 is associated with Gdynia Maritime University, currently is a professor of computer science in the Department...
-
Artificial Intelligence
e-Learning Courses -
Artificial intelligence
e-Learning Courses -
An optimised placement of the hard quality sensors for a robust monitoring of the chlorine concentration in drinking water distribution systems
PublicationThe problem of an optimised placement of the hard quality sensors in drinking water distribution systemsunder several water demand scenarios for a robust monitoring of the chlorine concentration is formulatedin this paper. The optimality is understood as achieving a desired trade off between the sensors and theirmaintenance costs and the accuracy of estimation of the chlorine concentration. The contribution of thiswork is a comprehensive...
-
Air Pollution: Monitoring
PublicationThe entry presents an overview of the issues in the field of air pollution monitoring. At the beginning, the general objectives of air monitoring, ambient air quality standards for so-called criteria pollutants, and their sources are discussed. In the next part, both analytical methods and instruments for monitoring of ambient air and stack gases are briefly presented. Additionally, other approaches used in air pollution monitoring,...
-
Artificial Intelligence Aided Architectural Design
PublicationTools and methods used by architects always had an impact on the way building were designed. With the change in design methods and new approaches towards creation process, they became more than ever before crucial elements of the creation process. The automation of architects work has started with computational functions that were introduced to traditional computer-aided design tools. Nowadays architects tend to use specified tools...
-
Application of artificial intelligence into/for control of flexible manufacturing cell
PublicationThe application of artificial intelligence in technological processes control is usually limited. One problem is how to respond to changes in the environment of manufacturing system. A way to overcome the above shortcoming is to use fuzzy logic for representation of the inexact information. In this paper fundamentals of artificial intelligence and fuzzy logic are introduced from a theoretical point of view. Still more the fuzzy...
-
Olgun Aydin dr
PeopleOlgun Aydin finished his PhD by publishing a thesis about Deep Neural Networks. He works as a Principal Machine Learning Engineer in Nike, and works as Assistant Professor in Gdansk University of Technology in Poland. Dr. Aydin is part of editorial board of "Journal of Artificial Intelligence and Data Science" Dr. Aydin served as Vice-Chairman of Why R? Foundation and is member of Polish Artificial Intelligence Society. Olgun is...
-
PRINCIPLES OF ARTIFICIAL INTELLIGENCE APPLICATION IN CONTROL OF THE ENTERPRISE
PublicationThe implementation of the tasks of evaluating historical financial information, the control or audit of business activities are based primarily on professional judgments about the object of study of a professional accountant or auditor. Their findings are drawn on the basis of the study of documents, the use of audit evidence, risk assessment, etc. There is always a probability (and rather high) that professional judgment will...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublicationThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...