displaying 1000 best results Help
Search results for: FIBER-OPTIC SENSORS
-
High-performance graphene-based biosensor using a metasurface of asymmetric silicon disks
PublicationIn recent years, optical biosensors widely applicable for medical applications, have received much attention. In this paper, we propose a high-performance polarization-insensitive optical biosensor based on a graphene-dielectric metasurface. The metasurface consists of an asymmetric dielectric disk array that supports a high Q-factor Fano resonance. The provided sharp Fano resonance results in an enhanced light-matter interaction...
-
Electrochemical detection of 4,4',5,5'-tetranitro-1H,1'H-2,2'-biimidazole on boron-doped diamond/graphene nanowall electrodes
PublicationWe present a promising approach to the electroanalytical detection of a specific nitroaromatic explosive in landfill leachates (LLs) that originated from a municipal solid waste plant. The paper is focused but not limited to the sensing of 4,4',5,5'-tetranitro-1H,1'H-2,2'-biimidazole (TNBI) using differential pulse voltammetry and cyclic voltammetry. Highly electroactive nanocarbon was applied to determine low concentrations of...
-
Qualitative and Quantitative Analysis of Selected Tonic Waters by Potentiometric Taste Sensor With All-Solid-State Electrodes
PublicationTaste sensor with five all-solid-state electrodes (ASSE) III (third version) was used for qualitative and quantitative analysis of selected tonic waters (J.Gasco, Kinley, Jurajski, Jurajski with citrus flavor, Carrefour, Schweppes Indian Tonic, and Schweppes Bitter Lemon). The results obtained by this taste sensor analyzed with principal component analysis, agglomerative hierarchical clustering methods show that this sensor can...
-
Novel Complementary Resonator for Dielectric Characterization of Substrates Based on Permittivity and Thickness
PublicationThis paper presents a novel complementary resonator featuring high sensitivity, low fabrication cost, and improved performance. The proposed structure consists of a complementary concentric square and circular ring resonator (CCSCRR) with multiple splits to enhance the inductance of the resonator. The proposed CCSCRR is coupled to a microstrip transmission line with an impedance of fifty ohms to create a high-sensitivity sensor....
-
Radar Signal Parameters Estimation Using Phase Accelerogram in the Time-Frequency Domain
PublicationRadar signal parameter estimation, in the context of the reconstruction of the received signal in a passive radar utilizing other radars as a source of illumination, is one of the fundamental steps in the signal processing chain in such a device. The task is also a crucial one in electronic reconnaissance systems, e.g. ELINT (Electronic Intelligence) systems. In order to obtain accurate results it is important to measure, estimate...
-
Using LSTM networks to predict engine condition on large scale data processing framework
PublicationAs the Internet of Things technology is developing rapidly, companies have an ability to observe the health of engine components and constructed systems through collecting signals from sensors. According to output of IoT sensors, companies can build systems to predict the conditions of components. Practically the components are required to be maintained or replaced before the end of life in performing their assigned task. Predicting...
-
Construction and investigation of SO2 amperometric sensor with a solid polymer electrolyte membrane
Publicationn this paper a sensor for detection of the sulphur dioxide based on three electrode cell configuration with a liquid electrolyte, a mercury sulphate reference electrode and a solid polymer electrolyte working electrode is presented. Working elec- trode was obtained by using Takenaka-Torikai chemical deposi- tion method by precipitation of Au particles into the pores of the Nafion membrane. Sensors characteristics measurements were...
-
Numerical modelling and experimental verification of compressible squeeze film pressure
PublicationThe validity of using the Reynolds equation for compressible squeeze film pressure was tested with computational fluid dynamics (CFD). A squeeze film air bearing was instrumented with pressure sensors and non-contacting displacement probes to provide transient measurements of film thickness and pressure. The film thickness measurements also provided input parameters to the numerical prediction. However, numerical results showed...
-
Analysis of magnetic field of Helmholtz's coils
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
Iron(III)-selective materials based on a catechol-bearing amide for optical sensing
PublicationThe synthesis and ion-binding properties of a new amide L derived from 3,4-dihydroxybenzoic acid are described. Due to the presence of a catechol unit, the compound interacts selectively with iron(III) in organic solvent (dimethyl sulfoxide, DMSO) to produce a color change from pale yellow to green. The incorporation of the ligand L into polymeric matrices or its encapsulation into surfactant-based spheres enables analyte detection...
-
Investigation on water infiltration and water content changes in a large-scale experimental test dike
PublicationThe paper presents result of series of experiments made within the DREDGDIKES project, performed on a test dike built from composite soil. The composite is produced by mixing fly ash (by-product of energetics) with dredged material (sand) taken from the mouth of The Vistula river. The test dike, located near Gdansk in Poland, was subjected to hydraulic load in several flooding time scenarios and the unsaturated unsteady flow was...
-
Methodology for assessing end-user requirements in the Ella4Life project: elders’ perspectives about self-monitoring
PublicationThe purpose of this paper is to explore elders’ perspectives about self-monitoring and using specially developed sensor technology for measuring health indicators. The qualitative research method is focus-groups with guidelines that were designed for understanding elder’s requirements about monitoring health indicators. We present them two devices: the first sensor is a device for monitoring of cardiac action potential fixed into...
-
Acute myocardial infarction - Male, 71 - Tissue image [330073006946921]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017642361]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017643841]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017643781]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017645971]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017646231]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017649311]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017649041]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Acute myocardial infarction - Male, 71 - Tissue image [12030630017646771]
Open Research DataThis is the histopathological image of HEART, MEDIASTINUM, AND PLEURA tissue sample obtained in Medical University Gdańsk and deposited in ZMDL-GUMED. The sample image was taken using: Pannoramic 250 3DHistech slide scanner (20x magnification) and saved to DICOM format.
-
Au nanoparticles identifiction with the use of AFM Volta potential mapping
Open Research DataThe specific physical, chemical and electrochemical electrical properties of gold nanoparticles have led to their extensive use as high-performance chemical and biochemical sensors. The described properties relate to surface plasmon resonance, fluorescence quenching or enhancement, high electrical conductivity and light scattering. The described nanoparticles...
-
Short-term measurement of physiological parameters - child (2)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Piotr Płotka dr hab. inż.
PeoplePiotr Płotka received the M.Sc. and D.Eng. degrees in electronic engineering from the Gdansk University of Technology, Poland, in 1976 and 1985. In 2008 he received D.Sc. (Dr.Hab.) degree, also in electronic engineering, from the Institute of Electron Technology at Warsaw, Poland. From 1977 he was with Academy of Technology and Agriculture at Bydgoszcz, Poland and from 1981 with the Gdansk University of Technology. In cooperation...
-
GPU based implementation of Temperature-Vegetation Dryness Index for AVHRR3 Satellite Data
PublicationPaper presents an implementation of TVDI (Temperature-Vegetation-Dryness Index) algorithm on GPU (Graphics Processing Unit). Calculation of this index is based on LST (Land Surface Temperature) and NDVI (Normalized Difference Vegetation Index). Discussed results are based on multi-spectral imagery retrieved from AVHRR3 sensors for area of Poland. All phases of TVDI implementation on GPU are modified in respect to CUDA platform....
-
Analysis of pressure ratio in the intake in dependence on high-voltage behaviours
PublicationPower control in spark ignition engines by regulating the intake air is performed. The control unit needs information about the air pressure conditions which then enters the combustion chamber. The information about the intake air pressure is an important quantity for optimal control of combustion mixtures. The paper describes some types of sensors that are used to measure the air intake temperature. Air pressure in the intake...
-
Disturbances of magnetic field in surrounding of mobile, metalic plate
PublicationThe uniform magnetic field of the Earth in the surrounding of a mobile, metalic object undergoes deformation by eddy currents. The influence of the moving conducting object on total magnetic field of the Earth depends on the object's shape, position and speed of the changes relative to the magnetic field's vector of the Earth as well as the electric conductivity and the relative magnetic permeability of the material. The disturbances...
-
Azo group(s) in selected macrocyclic compounds
PublicationAzobenzene derivatives due to their photo- and electroactive properties are an important group of compounds finding applications in diverse fields. Due to the possibility of controlling the trans–cis isomerization, azo-bearing structures are ideal building blocks for development of e.g. nanomaterials, smart polymers, molecular containers, photoswitches, and sensors. Important role play also macrocyclic compounds well known for...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
An adaptive approach to non-destructive evaluation (NDE) of cast irons containing precipitated graphite particles with the help of magnetoacoustic emission
PublicationPhysical properties of cast irons strongly depend on both their microstructure and the presence of casting defects. The paper analyses the possibility of application of magnetoacoustic emission (MAE) for nondestructive detection of flawed cast iron components. The investigated samples containing dross, chunky graphite and lamellar graphite were compared with the reference, flawless, spheroidal cast iron sample. The optimisation...
-
Studies on applicability of new solid-phase microextraction fibers for the selective extraction and determination of short - chain monocarboksylic acids
PublicationShort-chain monocarobxylic acids, sometimes referred to as volatile fatty acids (VFA), are a group of low molecular weight alkyl monocarboxylic acids that are widely distributed within the environment. These molecules contain any from 2 to 8 carbon atoms and originate from the anaerobic biodegradation of organic matter such as carbohydrates, proteins, and fats. These compounds are commonly found in the effluents from animal farming,...
-
COMPOSITE MATERIAL SELECTION FOR A PATIENT TRANSFER ASSIST DEVICE
PublicationLaminates - layered composites containing at least two elements (matrix and reinforcement) widely used in industry have also found their usage in medicine. Their main feature is the ability to modify the material in order to obtain the required properties. Depending on the needs, we can modify reinforcement, type of resin or the method of bonding substrates. Commonly used fibers are: carbon fiber, glass and aramid fibers; resins...
-
Two- and three-dimensional elastic networks with rigid junctions: modeling within the theory of micropolar shells and solids
PublicationFor two- and three-dimensional elastic structures made of families of flexible elastic fibers undergoing finite deformations, we propose homogenized models within the micropolar elasticity. Here we restrict ourselves to networks with rigid connections between fibers. In other words, we assume that the fibers keep their orthogonality during deformation. Starting from a fiber as the basic structured element modeled by the Cosserat...
-
Zastosowanie elektronicznych zmysłów w analizie żywności. Zastosowanie elektronicznego języka w analizie żywności.
PublicationW dzisiejszych czasach konsumenci zwracają dużą uwagę na takie cechy żywności jak: zapach, smak i wygląd. Ze względu na to naukowcy od wielu lat podejmują próby naśladowania ludzkich narządów zmysłów za pomocą urządzeń określanych jako elektroniczne zmysły. Zaliczamy do nich elektroniczny nos i język oraz komputerowy system rozróżnienia barw i kształtów. Elektroniczny język znany również jako sztuczny język lub czujnik smaku,...
-
Nucleation and growth of CVD diamond on fused silica optical fibres with titanium dioxide interlayer
PublicationNucleation and growth processes of thin diamond films on fused silica optical fibres have been investigated. Fibres were coated with diamond film using microwave plasma enhanced chemical vapour deposition (µPE CVD) system. Since the growth of diamond on the fused silica glass requires high seeding density, two types of glass pre-treatment were applied: titanium dioxide (TiO2) interlayer deposition and sonication in nanodiamond...
-
Thermal dewetting as a method of surface modification of the gold thin films for surface plasmon resonance based sensor applications
PublicationHere, we report a quick and simple approach with low, optimized production costs to obtain surface plasmon resonance (SPR) based sensors fabricated through a time- and resource-effective method based on thermal dewetting of thin Au films. From the applicative point of view, the method of detection presented here should be easier to implement, since light transmission measurements seem to be much less challenging than light refractive...
-
Distributed Architectures for Intensive Urban Computing: A Case Study on Smart Lighting for Sustainable Cities
PublicationNew information and communication technologies have contributed to the development of the smart city concept. On a physical level, this paradigm is characterised by deploying a substantial number of different devices that can sense their surroundings and generate a large amount of data. The most typical case is image and video acquisition sensors. Recently, these types of sensors are found in abundance in urban spaces and are responsible...
-
Engineering boron and nitrogen codoped carbon nanoarchitectures to tailor molecularly imprinted polymers for PFOS determination
PublicationPer- and polyfluoroalkyl substances (PFAS) have gained significant attention as emerging contaminants due to their persistence, abundance, and adverse health effects. Consequently, the urgent need for ubiquitous and effective sensors capable of detecting and quantifying PFAS in complex environmental samples has become a priority. In this study, we present the development of an ultrasensitive molecularly imprinted polymer (MIP)...
-
Long-term measurement of physiological parameters - a teenager (60 minutes) - the 2nd serie
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (105 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (105 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (100 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (100 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (100 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (70 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (70 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - a teenager (60 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - an adult (60 minutes)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (60 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - child (120 min)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Long-term (120 minutes) measurement of physiological parameters was performed on the healthy...
-
Long-term measurement of physiological parameters - patient 1 (serie 5)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 3 (serie 11)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 2 (serie 20)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...
-
Long-term measurement of physiological parameters - patient 1 (serie 11)
Open Research DataThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.A long-term (5 hours) measurement of physiological parameters was performed on the healthy volunteers...