Search results for: INLET%20AIR%20FOGGING
-
Velocity Field Characteristics at the Inlet to a Pipe Culvert
PublicationA poorly designed culvert inlet structure causes scouring, which can lead to the collapse of the culvert and significant damage to the neighboring land. A set of laboratory tests was evaluated to examine velocity distribution at the culvert inlet. A three-dimensional acoustic Doppler velocimeterwas used to measure instantaneous flowvelocity upstream of the culvert. The analysis of mean velocities, turbulence strength, and Reynolds...
-
APPLICABILITY OF INLET AIR FOGGING TO MARINE GAS TURBINE
PublicationThe dependency of marine gas turbine on the ambient temperature leads to a decrease of the gas turbine power output in arid areas. Very often gas turbine power output demand is high and the power margins originally designed into the driver , has been exhausted. In such circumstances the inlet air fogging is an effective compensation of gas turbine power. In this paper an analysis of inlet air fogging applicability to marine gas...
-
INFLUENCE OF INLET GEOMETRY ON THE EFFICIENCY OF 1MW STEAM TURBINE
PublicationThe process of the design of the 1MW steam turbine includes designing the stator and rotor blades, the steam turbine inlet and exit, the casing and the rotor. A turbine that operates at rotation speeds other than 3000 rpm requires a gear box and generator with complex electronic software. This paper analyses the efficiency of eight turbine variants, including seven inlet geometries and three stages of stator as well as an eight...
-
Inlet air fogging of marine gas turbine in power output loss compensation
PublicationThe use of inlet air fogging installation to boost the power for gas turbine engines is widely applied in the power generation sector. The application of fogging to mechanical drive is rarely considered in the literature [1]. This paper will cover some considerations relating to its application to gas turbines in ship drive. There is an important evaporative cooling potential throughout the world when the dynamic data is evaluated,...
-
Thermal and Hydrodynamic Phenomena in the Stagnation Zone — Impact of the Inlet Turbulence Characteristics on the Numerical Analyses
PublicationOne of the methods of heat transfer enhancement is utilization of the turbulent impinging jets, which were recently applied, for example, in the heat exchangers. Their positive impact on the heat transfer performance was proven, but many questions related to the origin of this impact are still unanswered. In general, the wall-jet interaction and the near-wall turbulence are supposed to be its main reason, but their accurate numerical...
-
Volute scroll as an alternative to guide vanes at inlet to turbine.
PublicationW pracy przedstawiono alternatywny sposób zasilania turbin parowych poprzez zastosowanie podwójnej spirali zasilającej. Przedstawiono model jednowymiarowy obliczania przepływu przez spirale oraz zamieszczono wyniki obliczeń typu 3D. Pokazano jak zależy parametr nierównomierności rozkładu prędkości na wylocie od sposobu kształtowania przekroju spiral.
-
Identification of damages in the inlet air duct of a diesel engine based on exhaust gas temperature measurements
PublicationThe temperature of the exhaust gas of a diesel piston engine, measured in the characteristic control sections of its thermo-flow system, can be a valuable source of diagnostic information about the technical condition of the elements limiting the working spaces thus separated, including the turbocharging system, but also its fuel supply system and replacement of the medium. In standard marine engine measurement systems equipped...
-
Effects of n-butanol presence, inlet loading, empty bed residence time and starvation periods on the performance of a biotrickling filter removing cyclohexane vapors from air
PublicationThis paper presents the results of investigations on the removal of cyclohexane vapors from air using a peat-perlite packed biotrickling filter. Effects of basic process parameters i.e. IL (inlet loading) and EBRT (empty bed residence time) as well as introduction of n-butanol to the treated air stream and starvation periods on the process performance were evaluated. The results show that the introduction of hydrophilic n-butanol...
-
Prediction of Wastewater Quality at a Wastewater Treatment Plant Inlet Using a System Based on Machine Learning Methods
PublicationOne of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at...
-
Evaluation of the significance of the effect of the active cross-sectional area of the inlet air channel on the specific enthalpy of the exhaust gas of a diesel engine using statistics F of the Fisher-Snedecor distribution
PublicationThis paper presents the application of Fisher-Snedecor distribution F statistics to assess the significance of the influence of changes in the active cross-sectional area of the inlet air channel (Adol) flow in a diesel engine on the observed diagnostic parameter determined on the basis of measurements of the quick changing exhaust gas temperature in the outlet channel, which is the specific enthalpy of the exhaust gas stream within...
-
Twin volute admission as an alternative inlet configuration for a steam tu- rbine.**2002, 164 s. 155 rys. bibliogr. 14 poz. maszyn. Podwójna spirala zasilająca jako alternatywny wlot do turbiny parowej. Rozprawa doktorska /2002.06.05/. PG, Wydz. Mechaniczny. Promotor: prof. dr hab. inż. R. Puzyrewski.
Publication.
-
Research of hydraulic axial piston pump at low ambient temperatures
Open Research DataPresented data include the results of measurements of oil temperature at the inlet and outlet of the hydraulic pump (theoretical displacement is equal to 16 cm3/rev) , temperature of the heated pump and oil pressure at the inlet and outlet of the pump.
-
Modeling lubricant flow between thrust-bearing pads
PublicationInlet temperature is one of the main inputs in all models for the analysis of fluid film bearing performance. At the same time, inlettemperature distribution and also oil velocity distribution at the inlet are the result of flow phenomena in the gap between the bearingpads. These phenomena are complex and in many cases further affected by any special arrangements of forced oil supply to the gapbetween pads. The reason for such...
-
INTENSYFIKACJA WYMIANY CIEPŁA W WYMIENNIKU WĘŻOWNICOWYM Z WYKORZYSTANIEM PRZEGRÓD O RÓŻNEJ GEOMETRII
PublicationW pracy zaprezentowano możliwości wykorzystania pasywnej intensyfikacji wymiany ciepła w postaci przegród dla podniesienia efektywności energetycznej wymiennika wężownicowego. Badania zostały przeprowadzone z wykorzystaniem modułowego wymiennika z wężownicą w postaci grzałki elektrycznej. Medium odbierającym ciepło była woda o stałych parametrach cieplnoprzepływowych na wlocie do modułu. Pomiary przeprowadzono dla szerokiego zakresu...
-
Przepustowość przepustu niezatopionego
PublicationPodczas przepływu w warunkach niezatopionego wlotu i wylotu w przewodzie przepustu woda tworzyć będzie swobodne zwierciadło. Przepływ bezciśnieniowy w przewodzie przepustu może wystąpić również w warunkach zatopionego wlotu. W pracy porównano wyniki obliczeń przepustowości całego przepustu i samego przewodu o przekroju kołowym i kwadratowym. W warunkach spokojnego ruchu wody, przy braku spiętrzenia na wylocie, o przepustowości...
-
Natural ventilation performance of family building in cold climate during windy days
PublicationAdequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the fresh air inside a building. A prediction of performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long term cost savings. The paper presents results of performance (air change rate ACH) and effectiveness (CO2 concentration in the breathing...
-
Biotrickling filtration of n-butanol vapors: process monitoring using electronic nose and artificial neural network
PublicationBiotrickling filtration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype combined with artificial neural network for biofiltration process monitoring in terms of reduction in n-butanol concentration and odour intensity of treated air. The study...
-
Natural ventilation performance of family building in cold climate during windless time
PublicationIn this paper, the field measurements results are presented on the stack ventilation effect. The paper presents the results of performance (air change rate ACH) natural ventilation for building with inlet gap measured for the transitional season (between heating and summer season). The measurements were performed during a windless time. The house was located in northern Poland, in a cold climate region. The measurement system...
-
Investigation of H2:CH4 plasma composition by means of spatially resolved optical spectroscopy
PublicationThe system based on spatially resolved optical emission spectroscopy dedicated for in situ diagnostics of plasma assisted CVD processes is presented in this paper. Measurement system coupled with chemical vapour deposition chamber by dedicated fiber-optic paths enables investigation of spatial distribution of species densities (Hx, H+, CH, CH+) during chemical vapour deposition process. Experiments were performed for a various...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 85
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a concave manifold, condenser temperature 30, evaporator temperature 70 and preheater temperature 40
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 90 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 70
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a rectangular manifold, condenser temperature 30 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a trapezoidal manifold, condenser temperature 70 and evaporator temperature 60
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 95
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
Testing an evaporator operation with a bifurcation manifold, condenser temperature 20 and evaporator temperature 90
Open Research DataThe experiment was conducted to test the evaporator operation. The heat exchanger was equipped with minigeometry (set of 50 parallel minichannels or single minigap). The studies were conducted for various mass flow rate of the working fluid and for various temperatures at the inlet of the evaporator. Accurate information about the test rig, the parameters...
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 25-75wt.% NiO-Al2O3
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 25/75 wt.% NiO-Al2O3 catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
Modelowanie przepływu pary przez okołodźwiękowe wieńce turbinowe z użyciem sztucznych sieci neuronoych
PublicationNiniejszy artykuł stanowi opis modelu przepływu pary przez okołodźwiękowe stopnie turbinowe, stworzonego w oparciu o sztuczne sieci neuronowe (SSN). Przedstawiony model neuronowy pozwala na wyznaczenie rozkładu wybranych parametrów w analizowanym przekroju kanału przepływowego turbiny dla rozpatrywanego zakresu wartości ciśnienia wlotowego.
-
FTIR spectra of gas mixtures from the methanation chamber filled with 50-50wt.% NiO-GDC
Open Research DataThe dataset includes the FTIR spectra collection of the outlet gas mixtures (CO2, CO, CH4) from reactor chamber filled with 50/50 wt.% NiO-GDC (Gadolinia Doped Ceria 20mol.%Gd2O3) catalyst for perfoming methanation reaction. The inlet gas mixture was composed of 3:1 by vol. H2:CO. Spectra were collected using PerkinElmer FTIR every 1 min.
-
An experimental investigation on the effect of new continuous core-baffle geometry on the mixed convection heat transfer in shell and coil heat exchanger
PublicationIn the article, the authors presented the influence of continuous core-baffle geometry at mixed convection heat transfer in shell and coil heat exchanger. Experiments were carried out for a large power range, i.e. from 100W to 1200W and mass flow rates ranging from 0.01 kg/s to 0.025 kg/s. During the experiments, the mass flow rate of cooling water, the temperature of water at the inlet and outlet as well as the wall temperature...
-
Direct-Ultrasonic Assisted Microextraction Coupled with RTL-GC-FID/GC-MS as a Future Standard Procedure for Monitoring 26 potentially Allergenic Fragrances in Water Samples
PublicationThis research topic grew up as a result of awareness of constant anthropogenic and natural input to the environment constituents of personal care products (PCPs) residues. This group of emerging pollutants encompasses a wide range of chemicals, including potentially allergenic fragrance compounds. The aim of the present study was to investigate presence of 26 fragrance allergens in water samples. Simple and rapid methodology based...
-
A numerical analysis of the thermal effects in the jet impingement stagnation zone
PublicationMost of the flows occurring in the engineering systems are turbulent and their accurate numerical analysis is still challenging, especially when combined with the heat transfer. One of the methods of heat transfer enhancement is utilization of the turbulent impinging jets, which were recently applied also in the heat exchangers. Their positive impact on the heat transfer performance was proven, but many questions related to its...
-
Sequential treatment of landfill leachate by electrocoagulation/aeration, PMS/ZVI/UV and electro-Fenton: Performance, biodegradability and toxicity studies
PublicationThis study presents a systematic study on sequential treatment of highly resistant landfill leachate by electrocoagulation (EC)/aeration, sulfate radical advanced oxidation process (SR-AOP) and electro-Fenton (EF). In case of SR-AOP, peroxymonosulfate (PMS) catalyzed by zero valent iron (ZVI) and ultraviolet irradiation (UV) system was developed. Treatment process was optimized in respect to COD removal. Analysis of results revealed...
-
Improving operating efficiency of a gas turboset via cooperation with an absorption refrigerating machine
PublicationThe analysis of increase of ambient air temperature entering the compressor on reduction in power output from the turbine and increase fuel use was conduced. For medium size gas turbine operates in winter and summer conditions elementary power and economical values was calculated. Conditions of the determination of turbine inlet air cooling solution (using thermal storage for reduce equipment size) are presented
-
Thermal energy storage using stearic acid as PCM material
PublicationThis work presents an experimental study of thermal energy storage by use of PCM. The aim of the study was to establish the influence of different inlet temperature of heat transfer fluid (HTF) and different Reynolds number of HTF on intensity of charging process. The PCM used in this study was stearic acid and water was used as HTF. A copper helical coil mounted in cylindrical container served as a heat transfer surface.
-
Carbon balance of SOFC fueled by biogas mixture at 750 C
Open Research DataThe dataset contains the calculated carbon balance for the SOFC fueled by synthetic biogas mixture (60:40 CH4:CO2). The outlet concentration of the gases from SOFC were measured using novel FTIR-based unit.
-
Optimizing CO2 Purification in a Negative CO2 Emission Power Plant
PublicationIn the pursuit of mitigating CO2 emissions, this study investigates the optimisation of CO2 purification within a Negative CO2 Emission Power Plant using a spray ejector condenser (SEC) coupled with a separator. The approach involves direct-contact condensation of vapour, primarily composed of an inert gas (CO2), facilitated by a subcooled liquid spray. A comprehensive analysis is presented, employing a numerical model to simulate...
-
Rational method of grit chamber efficiency determination
PublicationAlthough grot chambers are designed with utmost care, they still remain difficuly to control. As concentration of grit is non-uniform, representative measurements of the sand concentration is a very complex issue. In the paper the results of measure,ents performed at WTP in Gdańsk and Gdynia were analyzed. The proposed method to determine grit chambers efficiency is based on comparison of suspension flow in the inlet and flux of...
-
Optimized Hydrodynamic Vortex Separator
PublicationThe invention discloses an optimized hydrodynamic vortex separator which comprises an outer cylinder (1), an inner cylinder (2), a sludge hopper (3), an inlet (4), an outlet (5) and a conical structure (7), wherein the outer cylinder (1) is the boundary of the outer wall of the separator; wherein the inner cylinder (2) is arranged in an inner cavity of the outer cylinder (1); the sludge hopper (3)is taken as the bottom of the...
-
Exergy analysis of a negative CO2 emission gas power plant based on water oxy-combustion of syngas from sewage sludge gasification and CCS
PublicationA power cycle with water-injected oxy-combustion (water cycle) is investigated by exergy analysis. It is fueled with syngas (aka. producer gas) from gasification of sewage sludge. The cycle is equipped with a spray-ejector condenser (SEC). CO2 is separated and compressed for transportation and storage. The net delivered electric power is 31% of the fuel exergy. The task efficiency is 39% when the flue gas bleed to gasification...
-
Variational Method of Finding Streamlines in Ring Cascades for Creeping Flows
PublicationThis paper presents a new, analytical method of finding streamlinesfor creeping flows inside a ring cascade which is composed of an infinite number of infinitely thin blades. An analytical solution has been obtained through minimisation of a dissipation functional by means of variational calculus method. The necessary condition for optimum of a functional gives the Stokes equation if some additional assumptions are introduced....
-
DETEKCJA FAL UDERZENIOWYCH W UKŁADACH ŁOPATKOWYCH CZĘŚCI NISKOPRĘŻNYCH TURBIN PAROWYCH
PublicationW artykule przedstawiono wyniki numerycznych symulacji okołodźwiękowego przepływu pary przez ostatnie stopnie części niskoprężnej turbiny o mocy 50 MW. Celem przeprowadzonych symulacji była detekcja oraz lokalizacja fali uderzeniowej, występującej dla przyjętej geometrii układu łopatkowego. Przeanalizowano również wpływ zmiany wartości ciśnienia na wlocie do rozpatrywanych stopni turbiny na maksymalną wartość...
-
Comparison of various flow maldistribution quantification methods in mini heat exchangers
PublicationThe aim of study is to compare various flow maldistribution quantification methods, using velocity, mass flow rate, pressure, and temperature. An experimentally validated numerical study has been prepared and a heat exchanger with 34 semi-circular channels with a diameter of 3.1 mm has been tested. The minichannels were heated from the bottom with a heat flux of 50, 60, 70, and 80 kW/m2. The cases for various inlet velocities of...
-
How much a geometrical model of a honeycomb seal can be simpli ed in the CFD calculation
PublicationThis paper presents the inuence of geometry simplication on the results obtained in the computational fluid dynamics simulation. The subject of simulation was part of the honeycomb seal located at the inlet to high pressure part of a steam turbine. There were three different geometrical models assumed in the calculations. First one was two-dimensional case and two others were three dimensional, one with the radius of curvature...
-
Parametric study of fluid flow and heat transfer over louvered fins of air heat pump evaporator
PublicationTwo-dimensional numerical investigations of the fluid flow and heat transfer have been carried out for the laminar flow of the louvered fin-plate heat exchanger, designed to work as an air-source heat pump evap- orator. The transferred heat and the pressure drop predicted by simulation have been compared with the corresponding experimental data taken from the literature. Two dimensional analyses of the louvered fins with varying...
-
Management of low-temperature heat source by ORC aided by additional heat source
PublicationThe presented work is aimed at utilisation of waste heat in the manner to produce electricity in ORC installation. Therefore the precondition of the study was to use the waste heat available in the form of a stream of hot water at 90°C. Such low enthalpy heat source is rather insufficient to produce a good quality vapour to feed the ORC turbine. That was the incentive to search for the ways of increasing the temperature of the...
-
Revalorisation of the Szewalski’s concept of the law of varying the last-stage blade retraction in a gas-steam turbine
PublicationThe article presents the implementations of the free vortex law to the blade of the last stage of a gas-steam turbine. First, a thermodynamic analysis was carried out, determining the parameters at the inlet, then the number of stages of the high and low-pressure part of the turbine was constructed, together with the kinematics and velocity vectors for subsequent stages of the axial turbine. The last step of article was to take...