Filters
total: 34
Search results for: LV NETWORK
-
An ANN-Based Method for On-Load Tap Changer Control in LV Networks with a Large Share of Photovoltaics—Comparative Analysis
PublicationThe paper proposes a new local method of controlling the on-load tap changer (OLTC) of a transformer to mitigate negative voltage phenomena in low-voltage (LV) networks with a high penetration of photovoltaic (PV) installations. The essence of the method is the use of the load compensation (LC) function with settings determined via artificial neural network (ANN) algorithms. The proposed method was compared with other selected...
-
Voltage and Current Unbalance Reduction in Power Networks with Distributed Generation and Electric Vehicles
PublicationThe current development of prosumer microsources and the expected spread of electric vehicles may cause the appearance of significant current and voltage unbalance in low-voltage (LV) networks. This unbalance, which is an unfavorable phenomenon, may occur when using single-phase photovoltaic (PV) microsources and single-phase home chargers for electric vehicles. This paper presents a proposal for the symmetrization of the LV network...
-
Power Electronics Building Blocks for implementing Smart MV/LV Distribution Transformers for Smart Grid
PublicationWith an observed increase in the involvement of active consumers in activities aimed at improving energy efficiency and increasing interest in producing energy from renewable sources, there is a need for the development of new technologies enabling the distribution network operators to offer new services and functionalities. Smart MV/LV distribution transformers are characterized by a compact three-stage design, including an...
-
A new approach to cross-bonding in medium voltage cable lines
PublicationThe medium voltage underground cable sheaths are usually bonded and earthed in every substation on the cable route. This results in additional power losses in the sheaths. The paper presents an idea of reducing power losses caused by sheaths cross-bonding. The idea of sheaths cross-connecting only in selected MV/LV substations is given instead of a typical solution, where sheaths cross-bonding requires installing additional joints...
-
Metody doboru miejsc zainstalowania zasobników energii w sieciach elektroenergetycznych niskiego napięcia
PublicationW związku z rosnącą liczbą źródeł odnawialnych przyłączanych do sieci niskiego napięcia (nn) jakość energii elektrycznej w tej sieci ulega pogorszeniu. Jedną z metod jej poprawiania jest instalowanie zasobników energii, tj. baterii akumulatorów, superkondensatorów czy kół zamachowych. Zasobniki energii są w stanie złagodzić dobową zmienność obciążenia, skompensować moc bierną i wyższe harmoniczne oraz zmniejszyć asymetrię obciążenia...
-
Uproszone modelowanie sieci dystrybucyjnej na potrzeby analiz przyłączeniowych
PublicationW artykule przedstawiono rozważania na temat sposobu modelowania sieci średniego (SN) i niskiego (nn) napięcia na potrzeby wykonywania analiz przyłączeniowych przez operatorów sieci dystrybucyjnej. Przeprowadzono dyskusję na temat możliwych do wykonania uproszczeń w modelowaniu sieci, które są do zaakceptowania z punktu widzenia uzyskiwanego wyniku końcowego. Głównym elementem wymuszającym uproszenia w modelowaniu jest środowisko...
-
Regulacja napięcia w sieci nN z rozproszonymi źródłami energii
PublicationPodłączanie rozproszonych źródeł energii do sieci energetycznych niskiego napięcia powoduje powstawanie problemów zmienności i niesymetrii napięcia, zwłaszcza w przypadku dużych odległości od transformatora zasilającego. W skrajnych przypadkach zachodzi konieczność redukcji mocy generowanej przez źródło podczas oddawaniu energii do sieci. Rozwiązaniem tego problemu jest zastosowanie energoelektronicznego regulatora napięcia składającego...
-
Porównanie działania transformatora symetryzującego (zygzak) z aktywnym energoelektronicznym symetryzatorem prądów fazowych linii niskiego napięcia
PublicationNa potrzeby planowania sieci niskiego napięcia operatorzy systemów dystrybucyjnych (OSD) zakładają symetryczne warunki obciążenia linii. Z roku na rok, rośnie liczba rozproszonych systemów fotowoltaicznych (PV) zainstalowanych w sieciach niskiego napięcia, których większość to małe jednofazowe systemy dachowe. Dodatkowo, do niesymetrii obciążenia przyczyniają się instalowane masowo pompy ciepła i ładowane jednofazowo samochody...
-
Comparative Analysis of Phytochemical Profiles and Selected Biological Activities of Various Morphological Parts of Ligustrum vulgare
PublicationLigustrum vulgare (LV), widely cultivated in Europe and often used in hedges, has been histori-cally recognized in folk medicine for its potential health benefits. This study focused on exploring the untargeted identification of secondary metabolites in ethanol extracts (70% v/v) from differ-ent morphological parts (young shoots, leaves, flowers and fruits) of LV at various stages of plant development, using ultra-high-performance...
-
Dc Leakage Current in Isolated Grid-Connected dc Nanogrid - Origins and Elimination Methods
PublicationThe LV dc system is a relatively new trend in the distribution sector, which seems to grow widely in the near future due to its promising advantages. In this context, LV dc protection and grounding are challenging issues. Although the galvanically isolated connection mode of dc nanogrid to the ac grid has high reliability, the leakage current can still be injected into the ac grid through the interwinding capacitors and the insulation...
-
Existence of Two Periodic Solutions to General Anisotropic Euler-Lagrange Equations
PublicationAbstract. This paper is concerned with the following Euler-Lagrange system d/dtLv(t,u(t), ̇u(t)) =Lx(t,u(t), ̇u(t)) for a.e.t∈[−T,T], u(−T) =u(T), Lv(−T,u(−T), ̇u(−T)) =Lv(T,u(T), ̇u(T)), where Lagrangian is given by L=F(t,x,v) +V(t,x) +〈f(t),x〉, growth conditions aredetermined by an anisotropic G-function and some geometric conditions at infinity.We consider two cases: with and without forcing termf. Using a general version...
-
Management of MV/LV Transformer Replacement Based on AMI Platform
PublicationThe paper presents the extended possibilities of managing the selection and replacement of MV/LV transformers using the measurement data from the Advanced Metering Infrastructure (AMI) system. The analysis was conducted on samples of over 1900 transformers that operate in two different types of MV grids: rural and urban. The analysis has shown that there is a great potential in the field of optimizing the rated power of the transformers.
-
Could graphene construct an effective conducting network in a high-power lithium ion battery?
Publication -
Determination of changes in viscosity of hydrogel depending on shear rate (1.1 to 55 s-1).
Open Research DataThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.
-
Determination of changes in viscosity of refined oil depending on the temperature (19-96 Celsius degrees).
Open Research DataThe rheological characteristics of the refined oil were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 18 spindle and a shear rate of 52.8 s-1 in from temperature 19-96 °C.
-
Determination of changes in viscosity of hydrogel depending on shear rate (1.7 to 34 s-1).
Open Research DataThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 34 s-1.
-
Determination of changes in viscosity of hydrogel depending on shear rate (6.6 to 330 s-1).
Open Research DataThe rheological characteristics of hydrogel were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 18 spindle and shear rates from 6.6 to 330 s-1.
-
Determination of changes in viscosity of high-fructose syrup stability of pectin hydrogels depending on the temperature (25-96 Celsius degrees).
Open Research DataThe rheological characteristics of the high-fructose syrup modified stability of pectin (added in a concentration 2% m/m) were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 25 spindle and a shear rate of 0,22 s-1 in the temperature range 25-96 ° C. The data allowed selection of optimal conditions for the...
-
Determination of changes in viscosity of poly(acrylic acid) PAA solutions depending on shear rate.
Open Research DataThe rheological characteristics of poly(acrylic acid) PAA solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 27 spindles and shear rates from 1,7 to 39 s-1 (Fig. 1). PAA solutions with were prepared in water. The data allowed to characterize the used PAA and assess their functional parameters as rheology modifying...
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.1 to 55 s-1).
Open Research DataThe rheological characteristic of pectin gel (with concetration 0,45% m/m, in three independent repetition of sample) was made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindle and shear rates from 1.1 to 55 s-1.The data allowed to characterize the used hydrogel preparations and assess their functional...
-
Praca regulatora generatora w warunkach sprzyjających powstawaniu lawiny napięcia - wybrane problemy
PublicationW referacie zwrócono uwagę na wybrane zagadnieniazwiązane z pracą wieloparametrowego regulatora generatoraw warunkach awarii napięciowej. Przedstawiono wynikianalizy wpływu tak często pomijanego elementu układuregulatora generatora, jakim jest stabilizator systemowy.Zwrócono uwagę na celowość automatyzacji procesu zaniżaniamocy czynnej, dla zwiększenia możliwości generacjimocy biernej. Ponadto wskazano błędy w strukturze torugłównego...
-
The effect of changes in the concentration of hydroxypropylcellulose on the rheological stability of pectin hydrogels.
Open Research DataThe rheological characteristics of the pectin hydrogel modified by hydroxypropylcellulose (added in a concetration range from 0.1 to 0.55% m/m) were made on the basis of the viscosity assessment using a Brookfield viscometer with an LV SC4 - 25 spindle and a shear rate of 0,22 s-1 in the temperature range 19-96 ° C.The data allowed selection of optimal...
-
Determination of changes in viscosity of pectin gel depending on shear rate (1.7 to 85 s-1).
Open Research DataThe rheological characteristic of pectin gel (with concetration 0,25% m/m, in two independent repetitions) wasmade on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 27 spindle and shear rates from 1.7 to 85 s-1, in temperature of 25 C degee .The data allowed to characterize the used hydrogel preparations and assess...
-
The Impact of Micro-Sources on Voltage Distortions in a Power Grid
PublicationThe increase in the number of photovoltaic (PV) systems integrated with low voltage (LV) grids has led to a great need to analyse the impact of these systems on the quality of electricity and the reliability of its supply. This paper presents and compares the energy quality requirements imposed by various countries on photovoltaic plants. Then, based on real object tests and simulation in DIgSILENT PowerFactory, the impact has...
-
Praca regulatora generatora w warunkach sprzyjających powstawaniu lawiny napięcia - wybrane problemy
PublicationW referacie zwrócono uwagę na wybrane zagadnienia związane z pracą wieloparamatrowego regulatora generatora w warunkach awarii napięciowej. Przedstawiono wyniki analizy wpływu, tak często pomijanego elementu układu regulatora generatora, jakim jest stabilizator systemowy. Zwrócono uwagę na celowość automatyzacji procesu zaniżania mocy czynnej, dla zwiększenia możliwości generacji mocy biernej. Ponadto, wskazano błędy w strukturze...
-
Determination of changes in viscosity of chitosan cosmetic preparations depending on shear rate.
Open Research DataThe rheological characteristics of chitosan were made on the basis of a viscosity measurement using a Brookfield viscometer, using LV SC4 - 25 spindles and shear rates from 0.3 to 32 s-1 (Fig. 1). Chitosan solutions at 1% concentrations in acetic acid were prepared. The samples were subjected to storage tests.
-
Determination of changes in viscosity of chitosan solutions depending on shear rate.
Open Research DataThe rheological characteristics of chitosan solutions were based on viscosity measurements using a Brookfield viscometer, using LV SC4 - 25 spindles and shear rates from 4 to 53 s-1 (Fig. 1). Chitosan solutions with different molecular weights (low, medium and high) were prepared in concentrations from 1.5 to 3.0% in 0.5M acetic acid. The data allowed...
-
Determination of viscosity changes of protein hydrolyzate solutions depending on shear rate
Open Research DataRheological characteristics of connective tissue protein solutions were made on the basis of viscosity measurement using a Brookfield viscometer using LV SC4 - 27 spindles and shear rate of 85 s-1 (Fig. 1). Solutions of protein hydrolysates with a concentration of 2% in 0.5M acetic acid were prepared.
-
Determination of viscosity changes in dietary supplement solutions depending on temperature.
Open Research DataThe rheological characteristics of dietary supplement solutions were made based on viscosity measurement using a Brookfield viscometer, using the LV SC4 - 18 spindle and a shear rate of 53 s-1 (Fig.1).
-
Power converter interface for urban DC traction substations - solutions and functionality.
PublicationThis paper focuses on extending an urban DC traction substation functionality by means of an additional power converter interface (PCI). In particular, by enabling bidirectional energy exchange between LV DC traction grid, AC grid and V2G chargers. Among other things, the presented material compares general attributes of the most promising DC/DC converters that can be used in a PCI, meet the requirements of galvanic isolation and...
-
Determination of denaturation temperature of connective tissue proteins by viscometric measurements.
Open Research DataViscometric denaturation temperature of connective tissue proteins was determined by measuring viscosity with a Brookfield viscometer, using a LV SC4 - 18, 25 or LV3 spindle and shear rates from 50 to 110 s-1 (Fig.1). Freeze-dried protein samples were dissolved in 0.5 M acetic acid at 4 °C and concentration of 20 mg/mL. The solution was stirred with...
-
Characterization of Highly Filled Glass Fiber/Carbon Fiber Polyurethane Composites with the Addition of Bio-Polyol Obtained through Biomass Liquefaction
PublicationThis work aims to investigate the process of obtaining highly filled glass and carbon fiber composites. Composites were manufactured using previously obtained cellulose derived polyol, polymeric methylene diphenyl diisocyanate (pMDI). As a catalyst, dibutyltin dilaurate 95% and Dabco® 33-LV were used. It was found that the addition of carbon and glass fibers into the polymer matrix causes an increase in the mechanical properties...
-
Quality assessment of low voltage surge arresters
PublicationUsers expect reliable operation of the surge arrester during overvoltages, which may originate from a switching process or a lightning discharge. The necessary conditions to guarantee these expectations are: appropriate construction of the surge arrester, its production being maintained in accordance with technical standards, and a positive results of the type test (as well routine and acceptance tests). The recipient, especially...
-
Determination of the active ingredient in pharmaceutical gel formulation by NIR spectroscopy
PublicationPharmaceuticals of their intended must be thoroughly controlled. The traditional analytical methods are very costly and time consuming. NIR spectroscopy allows to analyze pharmaceutical materials very quickly and with very low costs. First pharmaceutical applications of the NIR spectroscopy appeared with some incuriosity in the late 1960s. Application of NIR in the contemporary pharmaceutical industry is very large. The most common...