Filters
total: 1688
filtered: 1124
-
Catalog
- Publications 1124 available results
- Journals 11 available results
- People 43 available results
- Inventions 8 available results
- Projects 20 available results
- Laboratories 1 available results
- Research Teams 4 available results
- e-Learning Courses 25 available results
- Events 2 available results
- Open Research Data 450 available results
Chosen catalog filters
displaying 1000 best results Help
Search results for: ELEKTRODA MEMBRANOWA CA(+)-SELEKTYWNA
-
Paraxial parameters and aberration of seven-electrode axisymmetric cathodic lens
Publication -
Properties of Nasicon-based CO2 sensors with Bi8Nb2O17 reference electrode
PublicationPotentiometric CO2 sensors based on Nasicon (Na+ conductor, Na3Zr2Si2PO12) electrolyte, Bi8Nb2O17/Pt reference electrode and different sensing electrodes have been prepared. Besides the sensing electrode material, sensors differ from each other in the reference electrode preparation technique. The main aim of this study is to investigate sensor construction and electrode fabrication process influence on sensor properties. The optimal...
-
Influence of titanium layer on counter electrode on electrical parameters of DSSC
PublicationIn this paper the influence of the Ti layer thickness at counter-electrode on electrical parameters of DSSCs was examined. The transparent conductive oxide – less (TCO-less) counter electrodes (CE) with titanium layers and platinum as catalyst on Bk7 glass were prepared. Thin metallic films were deposited by means of magnetron sputtering (titanium) and Pulsed Laser Deposition (platinum). The counter electrode with Pt layer on Fluorine...
-
Properties of Nasicon-based CO2 sensor with Bi8Nb2O17 reference electrode
PublicationGas sensors are useful for the carbon dioxide concentration monitoring in many applications. The major challenge is to develop a potentiometric sensor working without the necessity of a reference gas and without a need of the reference electrode encapsulation. Important issue is a selection of reference electrode material, which should provide stable reference potential. For example as reference electrode material in sensor based...
-
comparison of circular and rectangular narrow esps with longitudinal wire electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
Amperometric gas sensors with elektrodes chemically deposited on Nafion membrane
PublicationW pracy przedstawiono opis metod otrzymywania elektrod pracujących w czujnikach amperometrycznych gazów z elektrolitem ciekłym. Zaprezentowano metody chemiczne takie jak: metoda impregnacji-redukcji i metoda Takenaka-Torikai. Przedstawiono przegląd konstrukcji czujnikowych gazowych z elektrodami tego typu.
-
Properties of electrode modified with poly(3,4-ethylenedioxytiophene) and Pt particles.
PublicationWłaściwości warstw polimerowych poli(3,4-etylenodioksytiofenu)z cząstkami platyny zbadano pod względem zastosowania do reakcji utlenienia związków organicznych. Stwierdzono, bez wnikania w mechanizmy i kinetykę reakcji, że właściwości fizyczne jak i chemiczne (zdolność do katalizowania reakcji utlenienia alkoholi) zależą od materiału podłoża: Pt, węgiel szklisty, tytan, złoto.
-
Dynamic electrochemical impedance spectroscopy of the first order electrode reaction
PublicationCiągłe transformaty STFT sinusoidalnego sygnału pobudzenia i odpowiedzi prądowej zostały wyznaczone dla reakcji elektrodowej pierwszego rzędu. Wyznaczono impedancję elektrody w łącznej dziedzinie czasu i częstotliwości. Wykonano pomiary dla reakcji redukcji Cd(II) na rtęciowej elektrodzie kroplowej w funkcji potencjału. Przedstawiono możliwość wyznaczenia chwilowych widm impedancyjnych. Opisano zależność rezystancji przeniesienia...
-
Właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości i metoda ich wyznaczania
PublicationW pracy przeanalizowano właściwości metrologiczne elektrod woltamperometrycznych w dziedzinie częstotliwości. Wykazano, że w przypadku małych stężeń oznaczanych jonów, elektrody te mogą być traktowane jak przetworniki pomiarowe I rzędu. Ich właściwości metrologiczne charakteryzowane są przez czułość i częstotliwość graniczną. Przeanalizowano zastosowanie metody chronoamperometrycznej do wyznaczania wartości częstotliwości granicznej...
-
Wpływ namagnesowania elektrod otulonych na złącza spawane pod wodą metodą mokrą
PublicationDokonano analizy wpływu namagnesowania elektrod otulonych na geometrię i właściwości złączy teowych ze spoinami pachwinowymi wykonanych ze stali S235JR w środowisku wodnym. Stwierdzono, że dla zastosowanych warunków i parametrów spawania namagensowanie elektrod wpływa na stabilność jarzenia się łuku, powstawanie niezgoności spawalniczych typu błędy kształtu, natomiast nie ma wpływu na budowę mikrostrukturalną i twardość złączy...
-
Hybrid biobattery based on arylated carbon nanotubes and laccase
PublicationJednościenne nanorurki węglowe modyfikowano resztami antracenu i antrachinonu Otrzymany materiał posłużył do modyfikacji elektrody węglowej w celu jej zastosowania do redukcji tlenu w bioogniwie paliwowym. Nanorurki z aromatycznymi grupami zwiększyły powierzchnię elektrody oraz przyczyniły się do zwiększenia bezpośredniego przeniesienia elektronów. Grupy arylowe mogą wnikać do hydrofobowej kieszeni enzymu, w której znajduje się...
-
Studies of the effects of antifungal cationic derivatives of amphotericin B on human erythrocytes.
PublicationBadano nową grupę kationowych pochodnych amfoterycyny B pod kątem zależności pomiędzy ich zdolnością do asocjacji i selektywną toksycznością. We wszystkich przypadkach stosowano amfoterycynę B jako związek odniesienia. Jako miarę efektu toksycznego in vitro badanych związków stosowano wypływ wewnątrzkomórkowego potasu oraz hemolizę. Miarą aktywności przeciwgrzybowej był MIC i utrata potasu wewnatrzkomórkowego. Do oceny stopnia...
-
Synthesis of new trifunctional ligands based on 1,4,7,10-tetraazacyclododecane.
Publication1,4,7,10-tetraazacyklododekan jest cykliczną tetraaminą. Selektywne wprowadzenie różnych podstawników jest dość trudnym zadaniem. W pracy przedstawiono syntezę pozwalającą na wprowadzenie trzech różnych podstawników z wysokimi wydajnościami. Substratem w reakcji był dichroniony cyklen, który następnie wykorzystano do selektywnej substytucji podstawnika chinolinowego i długiego łańcucha alifatycznego, zakończonego grupą hydroksylową.Następnie...
-
Ocena przydatności komercyjnych elektrod otulonych do spawania mokrego pod wodą z wykorzystaniem analizy skupień
PublicationNajbardziej uniwersalną i ekonomiczną metodą remontów konstrukcji eksploatowanych pod wodą jest spawanie mokre elektrodami otulonymi. Ze względu na bardzo dobrą operatywność i stabilność jarzenia się łuku w środowisku wodnym stosuje się elektrody o otulinie rutylowej. Na rynku dostępnych jest kilka gatunków elektrod dedykowanych do prac podwodnych, których cena jest znacznie wyższa niż elektrod komercyjnych. Celem pracy było statystyczne...
-
Wpływ warunków spawania mokrego elektrodą otuloną na zawartość wodoru dyfundującego w stopiwie
PublicationMokre spawanie pod wodą znajduje stosunkowo szerokie zastosowanie w praktyce. Poza zwiększoną prędkością stygnięcia złączy najpoważniejszym ograniczeniem spawalności stali w środowisku wodnym jest wysoka zawartość wodoru dyfundującego w stopiwie. W artykule przedstawiono wyniki badań rozpoznawczych wpływu warunków spawania mokrego elektrodą otuloną na ilość wodoru dyfundującego. Dzięki zastosowaniu planowania doświadczeń (plan...
-
Wpływ warunków spawania na zawartość wodoru dyfundującego przy spawaniu mokrym elektrodą otuloną
PublicationPrzeprowadzono badania wpływu wybranych warunków spawania MMA pod wodą metodą mokrą na zawartość wodoru dyfundującego w stopiwie. Dzięki zastosowaniu planowania badań ustalono, że największy wpływ na generowanie wodoru ma: zasolenie wody, natężenie prądu spawania, biegunowość prądu spawania oraz zanieczyszczenie elektrody.
-
Właściwości dynamiczne elektrody woltamperometrycznej w dziedzinie częstotliwości i koncepcja metody ich wyznaczenia
PublicationW artykule przeanalizowano zasadę pracy elektrody woltamperometrycznej. Z przeprowadznej analizy wynika, że elektroda woltamperometryczna w przypadku oznaczeń małych stężeń jest przetwornikiem I rzędu. Jej właściwości metrologiczne określa czułość, stała czasowa i częstotliwość graniczna. W artykule zaproponowano metodę pomiaru parametrów dynamicznych na podstawie pomiaru prądu granicznego reakcji elektrochemicznj przebiegajacej...
-
Imidazoacridinone antitumor agent, c-1311, as a selective mechanism-based inactivator of human recombinant cytochrome P450 1A2
PublicationPrzedmiotem badań była przeciwnowotworowa pochodna imidazoakrydonu, C-1311, która pod nazwą Symadex R, znajduje się aktualnie w II fazie badań klinicznych. Wcześniejsze wyniki pozwoliły stwierdzić, że związek ten jest selektywnym inhibitorem niektórych enzymów cytochromowych. Podjęto zatem próbę wyjaśnienia mechanizmu inhibicji izoenzymów cytochromu P450 przez C-1311. Wykazano, że utrata aktywności katalitycznej obu izoenzymów...
-
Theoretical description of fundamental-harmonic impedance of a two-step electrode reaction
Publication -
Ellipsometric study of oxide formation on Cu electrode in 0.1 M NaOH
Publication -
Collection efficiency in narrow electrostatic precipitators with a longitudinal or transverse wire electrode
Publication -
Collection Efficiency in Narrow Electrostatic Precipitators with a Longitudinal or Transverse Wire Electrode
PublicationRecently narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application in diesel engine exhaust systems. In this work, results of particle collection efficiency measurements in narrow electrostatic precipitators for negative and positive dc voltage polarity are presented. The ESP usedin this work was a parallelepiped equipped with wire discharge electrode and two collecting plate-electrodes....
-
Ellipsometry study of oxide formation on Cu electrode in 0.1 M NaOH
PublicationPrzedstawiono przykład zastosowania techniki elipsometrii monochromatycznej w celu określenia dynamiki wzrostu warstw tlenkowych i wodorotlenkowych na miedzi w środowisku 0.1M NaOH. Badania te stanowią część projektu skupiającego się na oznaczeniu fizycznych i elektrycznych własności tlenku miedzi (I) oraz tlenku miedzi (II) podczas procesu formowania się warstwy. Jednoczesne pomiary elipsometryczne i impedancyjne są nowatorskie...
-
Effect of electrode waterproof coating on quality of underwater wet welded joints
PublicationIn this paper, the effects of different hydrophobic coatings on the surface of covered electrodes on the quality of wet welded carbon steel joints were discussed. Commonly available hydrophobic substances used in industrial applications were selected for the research. The aim of using waterproof coatings was to check the possibility to decreasing the susceptibility of highstrength low-alloy S460N steel to cold cracking. During...
-
Special techniques and future perspectives: Simultaneous macro- and micro-electrode recordings
PublicationThere are many approaches to studying the inner workings of the brain and its highly interconnected circuits. One can look at the global activity in different brain structures using non-invasive technologies like positron emission tomography (PET) or functional magnetic resonance imaging (fMRI), which measure physiological changes, e.g. in the glucose uptake or blood flow. These can be very effectively used to localize active patches...
-
Fabrication and properties of electrode material composed of ordered titania nanotubes and pEDOT:PSS
PublicationWe report on the two-stage preparation method of electrode material composed of titania nanotubes and poly(3,4-ethylenedioxythiopene):poly(2-styrenesulphonate) conductive polymer (pEDOT:PSS). Initially, titania nanotube arrays were produced by the anodization process of Ti substrate. Next, the polymer was potentiostatically deposited onto the thermally annealed nanotube arrays from the electrolyte containing monomer and counter...
-
Electrochemical Activity of Electrode Material Consisting of Porous Copper and Silica Aerogel
PublicationElectrochemically obtained copper was combined with silica aerogel (SiO2ag). Obtained composite (SiO2@Cu/CuxOy) was tested as an electrode in contact with LiPF6 in EC/DMC electrolyte. The electrochemical measurements showed the presence of complex redox couple activities of SiO2@Cu/CuxOy. This experiment was employed to help in understanding the carbon role used as an electric contact for silica in Li-Ion batteries and clarify...
-
Three electrode configuration measurements of electrolyte-diffusion barrier-cathode interface
PublicationMeasurements of a system consisting of cathode/doped ceria diffusion barrier/doped zirconia electrolyte were made using two- and three-electrode configuration. Results obtained on a three-electrode measurement configuration were compared with and reflect the results obtained in two-electrode configuration. Three-electrode measurements allowed separating the impact of the symmetrical interface in the investigated system. They also...
-
Influence of electrode geometric arrangement on the operation of narrow circular electrostatic precipitator
PublicationIn this work the influence of electrode geometric arrangement on the operation of a circular electrostatic precipitator (ESP) was investigated using Particle Image Velocimetry (PIV) method. The ESP was a glass circular cylinder (29 mm in diameter, 300 mm long) equipped with a wire discharge electrode and circular-cylinder collecting electrode. The stainless-steel discharge wire electrode (0.23 mm in diameter, 100 mm long) was mounted...
-
Application of bismuth film electrode for determination of heavy metals by stripping voltammetry
PublicationWhen Wang's research group introduced a new type of a working electrode: bismuth film plated electrode (BiFE), it has started attracting increasing attention in the field of electrochemical stripping analysis. These electrodes are shown to be very attractive alternative to common mercury-based electrodes, which are predominantly used in analysis of trace heavy metals.For the determination of heavy metals (Zn, Cd, Pb, Cu) used square...
-
Digital harmonic analysis of cadmium ion reduction on a dropping mercury electrode
PublicationBadano redukcję jonów kadmu na rtęciowej elektrodzie kroplowej. Jako pobudzenie zastosowano sinusoidalny sygnał napięciowy nałożony na liniowo zmieniający się potencjał dc. Przeprowadzono analizę czasowo-częstotliwościową prądu polarograficznego dla reakcji redukcji jonu kadmu na rtęciowej elektrodzie kroplowej. Klasyczna transformacja Fouriera prowadzi do dekompozycji prądu polarograficznego na składowe harmoniczne. Harmoniczne...
-
Teoria perkolacji i jej zastosowania w problematyce elektrod dla tlenkowych ogniw paliwowych
PublicationZaprezentowano podstawy teorii perkolacji oraz jej przykładowe zastosowania do opisu właściwości materiałów kompozytowych
-
Koncepcja zwiększenia dokładności czujnika tlenu rozpuszczonego
PublicationW artykule przedstawiono modyfikację konstrukcji elektrochemicznego czujnika do pomiaru stężenia tlenu rozpuszczonego w wodzie. Modyfikacja opiera się na zastosowaniu dodatkowych elektrod w pobliżu elektrody pracującej czujnika. Takie rozwiązanie prowadzi do zmniejszenia gradientu potencjału pola elektrycznego na powierzchni elekrody pracującej i tym samym powoduje zmniejszenie prądu migracyjnego czujnika, która jest główną składową...
-
Usuwanie lotnych związków organicznych z fazy gazowej z zastosowaniem cieczy jonowych
PublicationUżycie cieczy jonowej do usuwania LZO jest limitowane przez rozpuszczalność usuwanych związków. Dane literaturowe sugerują, że ciecze jonowe jako faza membranowa mogą być z powodzeniem stosowane do selektywnej separacji węglowodorów aromatycznych z mieszanin węglowodorów aromatycznych i alifatycznych. Przedmiotem pracy było kompleksowe opisanie procesu separacji LZO z fazy gazowej z uwzględnieniem czynników wpływających na efektywność...
-
Lower rim substituted p-tert-Butylcalix[4]arenes: Part XI. New ester derivatives of calix[4]arene, their ionophoric properties and x-ray structure studies
PublicationPrzedstawiono syntezę 6-ciu nowych estrowych pochodnych kaliks[4]arenuw konformacji stożkowej. Pierwsze badania kompleksowania jonów metali przeprowadzone w membranach elektrod jonoselektywnych (ISE) potwierdziły kompleksowanie jonów sodu w sposób selektywny. Zaprezentowano strukturę rentgenowską monokryształów związku 6.
-
Electrochemical oscillations and bistability during anodic dissolution of vanadium elektrode in acidic media. part 1. Experiment
PublicationDynamiczne niestabilności, oscylacje prądowe i bistabilność obserwowane były podczas anodowego roztwarzania elektrody wanadowej w trakcie badań wykorzystujących techniki stało i zmienno prądowe. Analizowany był wpływ warunków eksperymentalnych jak: stężenia kwasu, temperatury itd. Badania pozwoliły stworzyć diagramy przedstawiające regiony występowania oscylacji i bistabilności.
-
Diagnozowanie systemów ochrony katodowej techniką spektroskopii impedancyjnej
PublicationZaprezentowano wyniki badań wykonywanych techniką elektrochemicznej spektroskopii impedancyjnej (EIS) na elementach instalacji ochrony katodowej podziemnego rurociągu stalowego. Przedstawiono widma impedancyjne układów rurociąg-elektrody odniesienia (stacjonarne i przenośne). Wykazano, że przy pomocy EIS można zbadać stan techniczny elektrod odniesienia, co pozwala określić wiarygodność wyników pomiarów potencjału chronionej konstrukcji....
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based on p-tert-Butyl-calix[4]arene Thioamides.
PublicationTetra podstawione tioamidowe pochodne para-tert-butylokaliks[4]arenu (1-5) zostały zastosowane jako jonofory w membranowych elektrodach jonoselektywnych (EJS) selektywne na kationy Pb(II). Wyznaczono współczynniki selektywności. Czwartorzędowe kaliks[4]aren-tioamidy (1,2) wykazują nadzwyczaj dobrą selektywność na kationy Pb(II) w porównaniu z kaliks[4]aren-amidami. Membrany z tymi ligandami wykazują dużą trwałość, a charakterystyki...
-
Elektros energetiniai irengimai ir instaliacija. Vadoelis aukstesniosiomsir profesinems mokykloms.
PublicationZawarto: domowe instalacje elektryczne; urządzenia oświetleniowe i grzejne;przemysłowe instalacje elektryczne niskiego napięcia; ochrona przeciwporażeniowa w urządzeniach niskiego napięcia; linie napowietrzne; linie kablowe;stacje elektroenergetyczne; elektrownie; przepięcia i ochrona odgromowa; ochrona przed pożarami i wybuchami; impedancje elementów toru przesyłu energii;obliczanie spadku napięcia oraz strat mocy i strat energii...
-
Wykorzystanie immobilizowanych membran ciekłych w separacji gazów
PublicationZastosowanie immobilizowanych membran ciekłych w separacji gazów jest w ostatniej dekadzie bardzo intensywnie badane, co jest spowodowane głównie szybkim rozwojem metod syntezy nowych rozpuszczalników. Mimo to dobór odpowiedniego nośnika i fazy membranowej nastręcza wielu problemów. Właściwym rozwiązaniem, które zapewni efektywną, selektywną separację zanieczyszczeń gazowych a jednocześnie umożliwi ciągłe prowadzenie procesu be...
-
Organic electroluminescent devices containing phosphorescent molecules in molecularly doped hole transporting layer.
PublicationW pracy opisano mechanizm świecenia diody dwuwarstwowej diody elektroluminescencyjnej (EL) o zewnętrznej kwantowej wydajności świecenia osiągającej 9% fot./elektron. Warstwę transportującą elektrony tworzyła pochodna osadiazolu (PBD) otrzymana metodąnaparowania próżniowego. Warstwę transportującą dziury uzyskano przez wylanie roztworu poliwęglanu(PC), dendrymeru aminowego m-MTDATAoraz fosforyzującego kompleksu irydu Ir(ppy)3 i...
-
Elektro-magnetyczna metoda badania procesu degradacji stali austenitycznych
PublicationBadano próbki ze stali A304 oraz A347 po eksploatacji oraz próbki poddane deformacji plastycznej. Przyjęto założenie, że degradacja prowadzi do wzrostu zawartości fazy ferrytycznej w tych stalach, co może być wykorzystane do oceny stopnia degradacji. Artykuł prezentuje wyniki wstępnych badań nad możliwością wykrycia relatywnie niewielkich koncentracji fazy ferrytycznej. Próbki w początkowym stadium procesu degradacji (wycięte z...
-
Influence of the analyzing window on electrode impedance measurement by the continuous frequency scanning method
Publication -
Eucalyptus derived heteroatom-doped hierarchical porous carbons as electrode materials in supercapacitors
Publication -
Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode
Publication -
Weldability of Underwater Wet-Welded HSLA Steel: Effects of Electrode Hydrophobic Coatings
PublicationThe paper presents the effects of waterproof coatings use to cover electrodes on the weldability of high-strength, low-alloy (HSLA) steel in water. With the aim of improving the weldability of S460N HSLA steel in water, modifications of welding filler material were chosen. The surfaces of electrodes were covered by different hydrophobic substances. The aim of the controlled thermal severity (CTS) test was to check the influence...
-
Tin Oxide Encapsulated into Pyrolyzed Chitosan as a Negative Electrode for Lithium Ion Batteries
PublicationTin oxide is one of the most promising electrode materials as a negative electrode for lithium-ion batteries due to its higher theoretical specific capacity than graphite. However, it suffers lack of stability due to volume changes and low electrical conductivity while cycling. To overcome these issues, a new composite consisting of SnO2 and carbonaceous matrix was fabricated. Naturally abundant and renewable chitosan was chosen...
-
Potentiometric Solid-Contact Ion-Selective Electrode for Determination of Thiocyanate in Human Saliva
PublicationA new solid-contact potentiometric ion-selective electrode for the determination of SCN− (SCN-ISE) has been described. Synthesized phosphonium derivative of calix[4]arene was used as a charged ionophore. The research included selection of the ion-selective membrane composition, determination of the ISEs metrological parameters and SCN-ISE application for thiocyanate determination in human saliva. Preparation of the ISEs included...
-
Non-Contact Monitoring of ECG in the Home Environment—Selecting Optimal Electrode Configuration
PublicationCapacitive electrocardiography (cECG) is most often used in wearable or embedded measurement systems. The latter is considered in the paper. An optimal electrocardiographic lead, as an individual feature, was determined based on model studies. It was defined as the possibly highest value of the R-wave amplitude measured on the back of the examined person. The lead configuration was also analyzed in terms of minimizing its susceptibility...
-
Właściwości złączy spawanych pod wodą metodą mokrą elektrodami otulonymi (111)
PublicationPrzedstawiono analizę wpływu ilości wprowadzonego ciepła (energii liniowej), rodzaju złącza oraz rodzaju spawania (mokre, lokalną komorą suchą) na twardość złączy spawanych pod wodą.