Publications
Filters
total: 423
Catalog Publications
Year 2021
-
Influence of plasmon resonance on the luminescence of titanium dioxide thin films doped with rare earth ions
PublicationIn this work the study of the optical properties of europium doped titanium dioxide thin films (TiO2:Eu) enhanced by gold plasmonic nanostructures are presented. Plasmonic platforms were manufactured by thermal annealing of thin film of Au, deposited on a Corning glass substrate. As a result of thermal treatment, gold spherical nanostructures with average dimensions of 50 nm were obtained. Luminescent TiO2:Eu film was deposited...
-
Plasmon-enhanced photoluminescence from TiO2 and TeO2 thin films doped by Eu3+ for optoelectronic applications
PublicationIn this work we study the luminescence properties of europium-doped titanium dioxide and tellurium oxide thin films enhanced by gold plasmonic nanostructures. We propose a new type of plasmon structure with an ultrathin dielectric film between plasmonic platform and luminescent material. Plasmonic platforms were manufactured through thermal annealing of the gold thin film. Thermal dewetting of gold film results in spherical gold...
Year 2020
-
Electrodes criticality: the impact of CRMs in the leachate electrochemical oxidation
Publication -
Preparation and Characterization of an Electrospun PLA-Cyclodextrins Composite for Simultaneous High-Efficiency PM and VOC Removal
Publication -
The Luminescence of 1,8-Diazafluoren-9-One/Titanium Dioxide Composite Thin Films for Optical Application
Publication
Year 2019
-
Electroadsorptive Removal of Gaseous Pollutants
Publication -
Optical absorption and anisotropy of phosphorene flakes
Publication -
Paving the Way for A Sustainable and Efficient SiO2/TiO2 Photocatalytic Composite
Publication
Year 2018
-
A Novel Method for the Combined Photocatalytic Activity Determination and Bandgap Estimation
Publication -
Compressive Strength and Leaching Behavior of Mortars with Biomass Ash
Publication -
Indoor Air Quality: A Bibliometric Study
Publication -
Preparation and characterization of TiO2/carbon nanowall composite on a transparent substrate
Publication -
The Influence of LED Lighting Sources on the Nature of Power Factor
Publication
Year 2017
-
A special issue on Biophotonics in Europe
Publication -
Appraisal of a hybrid air cleaning process
Publication -
Influence of Binders and Lightweight Aggregates on the Properties of Cementitious Mortars: From Traditional Requirements to Indoor Air Quality Improvement
Publication -
Non-Destructive Testing for the In Situ Assessment of the Ionic Flux in Cementitious Materials
Publication
Year 2016
-
Application of thin dielectric films in low coherence fiber-optic Fabry-Pérot sensing interferometers: comparative study
Publication -
Introductory investigations of dermatologic diode laser with wavelengths 975 nm: clinical therapy of Recklinghausen disease and of hemangiomas
Publication
Year 2015
-
ALD thin ZnO layer as an active medium in a fiber-optic Fabry–Perot interferometer
Publication -
Enhanced capacitance of composite TiO2 nanotube/boron-doped diamond electrodes studied by impedance spectroscopy
Publication
Year 2014
-
Local impedance imaging of boron-doped polycrystalline diamond thin films
Publication -
Ranking of ecotoxisity tests for underground water assessment using the Hasse diagram technique
PublicationThe present study deals with the novel application of the Hasse diagram technique (HDT) for the specific ranking of ecotoxicity tests capable of assessment of underground water quality. The area studied is a multi-municipal landfill in the northern Poland. The monitoring network of the landfill constitutes of 27 piezometers for underground water monitoring and two observation points at surface water courses. After sampling, chemical...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
Publication
Year 2013
-
Amperometric sensing of chemical oxygen demand at glassy carbon and silicon electrodes modified with boron-doped diamond
Publication -
Application of Infrared Thermography to Non-Contact Testing of Varistors
Publication -
Electrochemical oxidation of sulphamerazine at boron-doped diamond electrodes: Influence of boron concentration
Publication -
Klawiatura ekranowa dla osób posługujących się jedną kończyną górną
Publicationrtykuł prezentuje układ symboli na klawiaturze wirtualnej dedykowanej osobom niepełnosprawnym posługującym się jedną kończyną górną. Rozmieszczenie znaków zostało ustalone na podstawie przeprowadzonej analizy częstotliwości występowania poszczególnych liter w języku polskim. Uwzględniono również najczęściej występujące pary liter, a odpowiadające im klawisze ułożono blisko siebie. Zaproponowany kształt klawiatury jest wynikiem...
-
Role of nitrogen in optical and electrical band gaps of hydrogenated/hydrogen free carbon nitride film
PublicationWe report the optical and electrical band gap energy of amorphous hydrogenated carbon nitride (a-HCNx) and carbon nitride (a-CNx) as a function of nitrogen concentration (N/C). The optical band gap of a-HCNx and a-CNx films has been determined by means of Ellipsometry and UV-VIS. Both optical and electrical band gaps increase with elevated nitrogen concentration. Experimentally obtained electrical band gap is compared with the...
Year 2012
-
A microcontroller system for measurement of three independent components in impedance sensors using a single square pulse
PublicationOpracowano nową metodę pomiaru w dziedzinie czasu i wyznaczania trzech składowych elementów modelu czujnika impedancyjnego oraz zaimplementowano ją w inteligentnym czujniku impedancji sterowanym 8-bitowym mikrokontrolerem. Metoda bazuje na pobudzeniu dzielnika napięciowego składającego się z rezystora pełniącego funkcję konwertera prąd na napięcie i z czujnika impedancji pojedynczym impulsem prostokątnym o czasie trwania T bezpośrednio...
-
Application of BDD thin film electrode for electrochemical decomposition of heterogeneous aromatic compounds
PublicationThe aim of the presented study is to investigate the applicability of electrochemical oxidation of aromatic compounds containing heteroatoms, e.g. waste from production of pesticides or pharmaceutics, at a borondoped diamond (BDD) electrode. The BDD electrodes were synthesized by microwave plasma enhanced chemical vapour deposition (MW PE CVD). Investigation of the electrode surface by optical microscopy and scanning electron microscopy...
-
Determination of chemical oxygen demand (cod) at boron-doped diamond (bdd) sensor by means of amperometric technique
PublicationA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Effect of mid-frequency discharge assistance on dual-high power impulse magnetron sputtering
Publication -
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
Publication -
Electrochemical oxidation of ionic liquids at highly boron doped diamond electrodes
PublicationUtlenianie elektrochemiczne przy zastosowaniu elektrod diamentowych wysoko domieszkowanych borem (BDD) było badane pod względem przydatności do utylizacji roztworów zawierających ciecze jonowe (ILs). Dwustronne elektrody Si/BDD przygotowano metodą chemicznego osadzania z fazy lotnej wspomaganego plazmą (MW PE CVD). Badanie przy użyciu skaningowej mikroskopii elektronowej (SEM) potwierdziło, że wytworzone warstwy były ciągłe i miały...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublicationIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublicationNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
Improving AFM images with harmonic interference by spectral analysis
PublicationPrzedstawiono sposób usunięcia zakłóceń pojawiających się na obrazach uzyskiwanych z mikroskopu sił atomowych (AFM). Przybliżono kilka metod stosowanych do redukcji zakłóceń w obrazach. Następnie opisano zidentyfikowane zakłócenia harmoniczne oraz zaproponowany sposób ich znaczącej redukcji. W pracy zamieszczono szereg obrazów uzyskanych z mikroskopu AFM ilustrujących efekty powodowane zakłóceniami oraz skuteczność zaproponowanej...
-
Investigation of Noise-Induced Instabilities in Quantitative BiologicalSpectroscopy and Its Implications for Noninvasive Glucose Monitoring
PublicationPrzedstawiono sposób oceny błędów jakie pojawiają się przy estymacji poziomu glukozy we krwi za pomocą pomiarów widm Ramana. Zastosowano nieliniowy algorytm regresji według maszyny wektorów nośnych. Określono jak na wyznaczenie stężenia glukozy we krwi wpływają błędy pomiarów widmach Ramana oraz błędów pomiaru referencyjnego stężenia glukozy podczas etapu kalibracji modelu (etapu uczenia algorytmu maszyny wektorów nośnych). Określono...
-
Low Current Transformer Utilizing Co-Based Amorphous Alloys
PublicationMetal oxide surge arresters have been widely used for protection of power system networks against overvoltages due to atmospheric discharges or malfunction of devices connected to the network. During its operation a surge arrester structure is degradated, what can be observed as an increase of a surge arrester leakage current. Paper presents an implementation of a new, high-permeability, Co64Fe4Ni1Si15B14 amorphous alloy as a current...
-
Method and measurement system for DC characteristics measurement of power diodes in very wide current range
PublicationW artykule przedstawiono układ pomiarowy do pomiaru charakterystyk stałoprądowych diod. Pomiar przeprowadzany jest metodą impulsową w celu zapewnienia stałej temperatury badanego elementu w trakcie pomiaru. Do zapewnienia odpowiedniej liczby punktów pomiarowych wykorzystano układ zmodyfikowanej drabinki R2R z pojedynczymi kluczami sterującymi.
-
Mikro system zasilania bezprzewodowego
PublicationWzrastająca na rynku liczba układów mikrokontrolerów o bardzo niskiej konsumpcji energii elektrycznej umożliwia budowę układów zasilania bezprzewodowego, opartych o układy zbierające energię elektryczną z różnych źródeł występujących w naszym otoczeniu. Obecnie powstające układy wytwarzające energie elektryczną korzystają z jej konwersji m.in. z następujących źródeł: promieniowania słonecznego, energii drgań i wibracji, występujących...
-
Non-destructive inspection of anti-corrosion protective coatings using optical coherent tomography
PublicationW artykule przedstawiono zastosowanie optycznej tomografii koherentnej (OCT) do badania antykorozyjnych powłok ochronnych. Omówiono właściwości optycznej interferometrii niskokoherentnej jako zastosowanej metody pomiarowej, opisano budowę pomiarowego systemu OCT, zbudowanego w Katedrze Metrologii i Optoelektroniki WETI PG. Przy pomocy zrealizowanego systemu przebadano grupę powierzchni metalicznych pokrytych różnymi powłokami antykorozyjnymi....
-
Plasma diagnostics of low pressure high power impulse magnetron sputtering assisted by electron cyclotron wave resonance plasma
Publication -
Problems of varistor quality assessment during exploitation
PublicationVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Przenośny analizator impedancji z detektorem fazoczułym
PublicationW artykule przedstawiono prototyp analizatora impedancji, w którym zastosowano dwa mikrosystemy AD5933 do wydzielania składowych ortogonalnych sygnałów pomiarowych w zakresie częstotliwości od 0,01 Hz do 1 kHz i detektory fazoczułe dla częstotliwości z przedziału 1 kHz ÷ 100 kHz. Przyjęte rozwiązanie pozwoliło wyeliminować błędy pomiaru argumentu impedancji wprowadzane przez AD5933 w górnym zakresie częstotliwości. Uzyskany błąd...
-
Quality testing methods of foil-based capacitors
PublicationKondensatory foliowe są powszechnie stosowanymi elementami pasywnymi w ukłądach zasilania. Dotychczasowe metody oceny ich jakości są długotrwałe oraz zużywają energię. W pracy przedstawiono propozycje szeregu nowych, bardziej efektywnych metod, które mogą być z sukcesem stosowane podczas ich produkcji.
-
Remote Monitoring System for Impedance Spectroscopy using Wireless Sensor Network
PublicationThe architecture of a miniaturized impedanceanalyser with wireless communication module for remoteImpedance Spectroscopy (IS) of anticorrosion coatings ondifficult-to-reach objects (e.g. on the steel construction ofthe bridge) is described in this paper. Some practical aspectsof implementation of a Wireless Sensor Network (WSN) arealso discussed. A low scale, middle range, WSN networkcomposed of a Base Station (BS) with a Personal...
-
Self-testing of analog parts of mixed-signal electronic microsystems based on multiple sampling of time responses
PublicationW artykule przedstawiono nowe podejście samo-testowania toru analogowego zakończonego przetwornikiem A/C w mieszanych sygnałowo elektronicznych systemach wbudowanych sterowanych mikrokontrolerami. Bazuje ono na nowej metodzie diagnostycznej opartej na przekształceniu transformującym zbiór próbek odpowiedzi czasowej układu badanego na pobudzenie impulsem prostokątnym na rodzinę krzywych identyfikacyjnych umieszczonych w przestrzeni...
-
Spectroscopic and wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement has been presented. the sensor, designed and developed by authors, consists of spectroscopic set-up controlled by a microcontroller. measurement results are sent via wireless module. experiment has confirmed the ability of the sensor to determine the hematocrit with appropriate measurementaccuracy.